Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW VELOCITY - DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Achromatic Emission Velocity Measurements in Luminous Flows

A new velocity measurement instrument for luminous flows was developed by Science Research Laboratory for NASA. The SIEVE (Segmented Image Emission VElocimeter) instrument uses broadband light emitted by the flow for the velocity measurement. This differs from other velocimetry techniques in that it does not depend on laser illumination and/or light scattering from particles in the flow. The SIEVE is a passive, non-intrusive diagnostic. By moving and adjusting the imaging optics, the SIEVE can provide three-dimensional mapping of a flow field and determine turbulence scale size. A SIEVE instrument was demonstrated on an illuminated rotating disk to evaluate instrument response and noise and on an oxy-acetylene torch to measure flame velocities. The luminous flow in rocket combustors and plumes is an ideal subject for the SIEVE velocity measurement technique.

Schneider, S. J.↗

Correlation of macro and micro cardiovascular function during weightlessness and simulated weightlessness

The investigation of cardiovascular function necessarily involves a consideration of the exchange of substances at the capillary. If cardiovascular function is compromised or in any way altered during exposure to zero gravity in space, then it stands to reason that microvascular function is also modified. We have shown that an increase in cardiac output similar to that reported during simulated weightlessness is associated with a doubling of the number of post-capillary venules and a reduction in the number of arterioles by 35%. If the weightlessness of space travel produces similar changes in cardiopulmonary volume and cardiac output, a reasonable expectation is that astronauts will undergo venous neovascularization. We have developed an animal model in which to correlate microvascular and systemic cardiovascular function. The microcirculatory preparation consists of a lightweight, thermo-neutral chamber implanted around intact skeletal muscle on the back of a rat. Using this technique, the performed microvasculature of the cutaneous maximus muscle may be observed in the conscious, unanesthetized animal. Microcirculatory variables which may be obtained include venular and arteriolar numbers, lengths and diameters, single vessel flow velocities, vasomotion, capillary hematocrit anastomoses and orders of branching. Systemic hemodynamic monitoring of cardiac output by electromagnetic flowmetry, and arterial and venous pressures allows correlation of macro- and microcirculatory changes at the same time, in the same animal. Observed and calculated hemodynamic variables also include pulse pressure, heart rate, stroke volume, total peripheral resistance, aortic compliance, minute work, peak aortic flow velocity and systolic time interval. In this manner, an integrated assessment of total cardiovascular function may be obtained in the same animal without the complicating influence of anesthetics.

NASA Discipline Number 00-00↗

Effect of Low Frequency Repetitive Transcranial Magnetic Stimulation (rTMS) Combined with Hyperbaric Oxygen (HBO) on Awakening of Coma Patients with Traumatic Brain Injury

Coma caused by craniocerebral injury is a common condition of neurosurgical acute injury. There is no specific method to promote awakening in a clinic. Early comprehensive treatment may be helpful to patients. The common methods are hyperbaric oxygen (HBO) and low-frequency repetitive transcranial magnetic stimulation (rTMS). However, the application effect and mechanism of rTMS combined with HBO on coma patients with traumatic brain injury need to be further studied. The brain stem auditory evoked potential (BAEP) is examined by the Kennedy coma recovery scale (CRS-R), the recovery of brain function and the state of consciousness are evaluated, and the therapeutic effect is evaluated by the Glasgow Coma Scale (GCS). Cerebrospinal fluid NE level, MCA blood flow velocity, and left brainstem and right brainstem auditory evoked potential are used to evaluate brain rehabilitation. RTMS combined with HBO could shorten the wake-up time, improve the wake-up rate, improve the GCS score and CRS-R score, shorten the brain wave latency time of the left and right brainstem, increase the NE level of cerebrospinal fluid, and decrease the blood flow velocity of MCA. RTMS combines with HBO can improve the nerve excitability of brain cells, reduce the disturbance of consciousness, promote the functional recovery of brain injury, and has a certain role in promoting the awakening of patients with traumatic brain injury coma.

Liu, Mei↗

Nonintrusive fast response oxygen monitoring system for high temperature flows

A new technique has been developed for nonintrusive in situ measurement of oxygen concentration, gas temperature, and flow velocity of the test media in hypersonic wind tunnels. It is based on absorption of near-infrared radiation from inexpensive GaAlAs laser diodes used in optoelectronics industry. It is designed for simultaneous measurements along multiple lines of sight accessed by fiber optics. Molecular oxygen concentration is measured from the magnitude of absorption signals; rotational gas temperature is measured from the intensity ratio of two oxygen absorption lines; and the flow velocity is measured from the Doppler shift of the absorption line positions. This report describes the results of an extensive series of tests of the prototype instrument in laboratory flames emphasizing assessment of the instruments capabilities for quantitative measurement of O2 concentration (mole fraction) and gas temperature.

Oh, Daniel B.↗

Corrosion of Stainless and Carbon Steel in Aqueous Piperazine for CO2 Capture

Current obstacles that prevent commercial implementation of amine-scrubbing CO2 capture are the high costs. Reducing capital costs by appropriate selection of construction materials, which requires knowledge of material corrosion performance for the process, will improve the economic feasibility of this technology. Corrosion was evaluated in three pilot plant campaigns using aqueous piperazine with the Advanced Stripper (PZAS). 316L stainless steel (SS) experienced higher corrosion than 304 SS and 2205 duplex SS, and the corrosion rate showed strong dependence on the temperature. 304 and 2205 performed well at all locations and should be good construction materials for PZAS. Degraded PZ exacerbated 316L corrosion, and removal of PZ degradation products using a carbon adsorption bed significantly reduced corrosion. Carbon steel (CS) corrosion showed a weak temperature effect because the corrosion was more dependent on the protective siderite film. The protectiveness of the films was related to fluid velocity. Ni-based alloys corroded in PZ, and the rate increased with temperature. Corrosion of C1010 CS and SS (304, 316L, 430) was measured at absorber and water wash conditions on the bench-scale. Corrosion rate decreases with increasing PZ. 8 With more than 0.003 m PZ in solution, CS has acceptable corrosion performance. Corrosion of CS increases with increasing partial pressure of CO2, suggesting loading is another dominant parameter for carbon steel corrosion. Temperature has a less significant effect than PZ concentration and loading. CS corrosion increases with increasing flow velocity at both absorber and water wash conditions. SS had little corrosion at this lower temperature. Performance of siderite (FeCO3) protective films on CS was studied at representative stripper conditions on the bench-scale. Siderite films can deposit on the surface of CS in CO2-loaded PZ solution at temperatures >100 °C and protect CS from corrosion. The protection may fail in degraded PZ. Ethylenediamine (EDA) is one of the major contributors for the loss of film protectiveness or can be the surrogate for the effect of PZ degradation on siderite film protection. A link between protectiveness and the apparent density of siderite films was discovered. The apparent density of siderite films decreases with increasing flow velocity and decreasing CO2 loading, resulting in higher corrosion of CS.

Liu, Ching-Ting↗

Combustion Limits and Efficiency of Turbojet Engines

Combustion must be maintained in the turbojet-engine combustor over a wide range of operating conditions resulting from variations in required engine thrust, flight altitude, and flight speed. Furthermore, combustion must be efficient in order to provide the maximum aircraft range. Thus, two major performance criteria of the turbojet-engine combustor are (1) operatable range, or combustion limits, and (2) combustion efficiency. Several fundamental requirements for efficient, high-speed combustion are evident from the discussions presented in chapters III to V. The fuel-air ratio and pressure in the burning zone must lie within specific limits of flammability (fig. 111-16(b)) in order to have the mixture ignite and burn satisfactorily. Increases in mixture temperature will favor the flammability characteristics (ch. III). A second requirement in maintaining a stable flame -is that low local flow velocities exist in the combustion zone (ch. VI). Finally, even with these requirements satisfied, a flame needs a certain minimum space in which to release a desired amount of heat, the necessary space increasing with a decrease in pressure (ref. 1). It is apparent, then, that combustor design and operation must provide for (1) proper control of vapor fuel-air ratios in the combustion zone at or near stoichiometric, (2) mixture pressures above the minimum flammability pressures, (3) low flow velocities in the combustion zone, and (4) adequate space for the flame.

Barnett, H. C.↗

Early time evolution of negative ion clouds and electron density depletions produced during electron attachment chemical release experiments

Two-dimensional electrostatic particle-in-cell simulations are used to study the early time evolution of electron depletions and negative ion clouds produced during electron attachment chemical releases in the ionosphere. The simulation model considers the evolution in the plane perpendicular to the magnetic field and a three-species plasma that contains electrons, positive ions, and also heavy negative ions that result as a by-product of the electron attachment reaction. The early time evolution (less than the negative ion cyclotron period) of the system shows that a negative charge surplus initially develops outside of the depletion boundary as the heavy negative ions move across the boundary. The electrons are initially restricted from moving into the depletion due to the magnetic field. An inhomogenous electric field develops across the boundary layer due to this charge separation. A highly sheared electron flow velocity develops in the depletion boundary due to E x B and Delta-N x B drifts that result from electron density gradients and this inhomogenous electric field. Structure eventually develops in the depletion boundary layer due to low-frequency electrostatic waves that have growth times shorter than the negative ion cyclotron period. It is proposed that these waves are most likely produced by the electron-ion hybrid instability that results from sufficiently large shears in the electron flow velocity.

Scales, W. A.↗

Molecular velocimetry using stimulated Raman spectroscopy

Molecular flow velocity of N2 was measured in a supersonic wind tunnel using inverse Raman spectroscopy. This technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counter-propagating (backward scattering). A retrometer system is employed to yield a vibration-free optical configuration which has the additional advantage of obtaining both the forward and backward scattered spectra simultaneously. The linebreadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the concept was performed in a supersonic wind tunnel and included: (1) measurements over the Mach number range 2.50 to 4.63; (2) static pressure measurements (at Mach 2.50) corresponding to a Reynolds number per foot range of 1 to 5 x 10 to the 6th power; and (3) measurements behind the shock wave of a flat plate model.

Exton, R. J.↗

Kinetic closures for unmagnetized and magnetized plasmas

Parallel and perpendicular closures with cyclotron resonance effects retained for the five-moment (density, temperature, and flow velocity) fluid equations are derived by solving the kinetic equation with the Bhatnagar–Gross–Krook operator in Fourier space. For parallel propagation, the parallel closures are reduced to those of Ji et al. [Phys. Plasmas 20, 082121 (2013)]. The closures when combined to the fluid equations reproduce the fully kinetic dispersion relation that can be directly derived from the kinetic equation. The closures for the five-moment fluid system can be utilized to derive closures for the extended fluid system, which is demonstrated by deriving closures for the ten-moment system consisting of density, flow velocity, temperature, and viscosity tensor equations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

Seismic Study of the Dynamics of the Solar Subsurface from SoHO Observations

In collaboration with Dr. Baudin, we have developed and refined the new observational methodology for local helioseismology known as time-distance analysis. Global helioseismology study the solar oscillations as a superposition of resonant modes, whose properties (mode frequencies) reflect the global structure of the sun (sound speed stratification, rotation rate, etc). In contrast, local helioseismology look at the solar oscillations as wave packets whose propagation will be affected by perturbations of the media sampled. These local perturbations (sound speed or velocity flows) will modify the propagation time, that in turn can be used as a diagnostic tool for a given region. From a data reduction perspective, the processing of solar dopplergrams that result in time-distance maps, i.e. propagation times as a function of distance between bounces at the surface, is radically different from the methodology used for global mode analysis. We have, in a first step, further develop the programs needed to carry out such analysis. We have then applied them to NMI data set, and explore the trade-off between various averaging and filtering approaches - steps required to improve the signal-to-noise ratio of correlation maps - and the resulting stability and precision of the fitted propagation times. While excessive averaging (whether over space, propagation distance, or time) will reduce the diagnostic potential of the method, insufficient averaging lead to unstable fits, or uncertainties so large as to hide the information we seek. In a second phase, we have developed the analysis methodology required to infer local properties from perturbation in time propagation. Namely, we have developed time-distance inversion techniques, with an emphasis on inferences of velocity flows from time anomalies. Note also that during the period covered by this grant, all the investigators on this proposal (i.e., Drs. Baudin, Eff-Darwich, Korzennik, and Noyes) took part in the organization of the SOHO 6 /GONG 99 Workshop: Structure and Dynamics of the Interior of the Sun and Sunlike Stars, held on June 1-4 1999 at the Boston Park Plaza Hotel in Boston, Massachusetts, USA. it was very well attended by more than 160 participants from 26 countries from all over the world. The proceedings were published in two volumes as ESA SP-418, with Sessions I-III in Volume 1, and Sessions IV-VI in Volume 2 (1,000 pages in total). The complete contents are also included in digital form on a CD-ROM included with Volume 1. This CD-ROM also contains additional multi-media material that complements some of the contributions.

Korzennik, Sylvain G.↗

FSVPy: A python-based package for fluorescent streak velocimetry (FSV)

Predictive constitutive equations that connect easy-to-measure transport properties (e.g., viscosity and conductivity) with system performance variables (e.g., power consumption and efficiency) are needed to design advanced thermal and electrical systems. In this work, we explore the use of fluorescent particle-streak analysis to directly measure the local velocity field of a pressure-driven flow, introducing a new Python package (FSVPy) to perform the analysis. Fluorescent streak velocimetry combines high-speed imaging with highly fluorescent particles to produce images that contain fluorescent streaks, whose length and intensity can be related to the local flow velocity. By capturing images throughout the sample volume, the three-dimensional velocity field can be quantified and reconstructed. We demonstrate this technique by characterizing the channel flow profiles of several non-Newtonian fluids: micellar Cetylpyridinium Chloride solution, Carbopol 940, and Polyethylene Glycol. We then explore more complex flows, where significant acceleration is created due to microscale features encountered within the flow. We demonstrate the ability of FSVPy to process streaks of various shapes and use the variable intensity along the streak to extract position-specific velocity measurements from individual images. Thus, we demonstrate that FSVPy is a flexible tool that can be used to extract local velocimetry measurements from a wide variety of fluids and flow conditions.

Mechanics↗

Doppler instrumentation for measuring blood velocity and flow

Doppler ultrasonic blood flowmeters are reviewed in detail. The importance of measurement accuracy for transcutaneous flowmeters and their clinical application is stressed. Doppler imaging was combined with conventional pulse echo imaging, and diagnostic information was extracted from flow signals. The range and extent of applications of Doppler instruments was also presented.

Gill, R. W.↗

Transonic flow past a symmetrical airfoil at high angle of attack

The results of an experimental investigation of shock-induced stall and leading-edge stall on a 64A010 airfoil section are presented. Advanced nonintrusive techniques - laser velocimetry, holographic interferometry, and buried-wire anemometry - were used in characterizing the inviscid and viscous flow regions. The measurements include Mach contours of the inviscid flow regions, and mean velocity, flow direction and Reynolds shear stress profiles in the separated regions. The experimental observations of this study are relevant to efforts to improve surface pressure prediction methods for airfoils at or near stall.

Johnson, D. A.↗

Evolution of the earth's distant magnetotail - ISEE 3 electron plasma results

ISEE 3 data form the basis for a study of the evolution of the electron plasma in the magnetotail lobe and plasma sheet regions as a function of radial distance from the earth. The data were plasma electron and magnetometer measurements taken when the ISEE 3 was tailward of the earth during three different orbits. About 91,000 electron spectra were obtained in terms of the magnetosheath, lobe, plasma sheet and radial downstream distances. The lobe density peaked at 60 earth radii, while the sheet density tapered very slowly downstream. At large downstream distances (about 180 radii), the plasma bulk flow velocity increased significantly, surpassing the solar wind velocity. The bimodal electron flow angle near the earth became a single tailward flow at 180 radii.

Zwickl, R. D.↗

Program For Analysis Of Axial-Flow Compressors

CSPAN (Compressor SPanline ANalysis) computer program assists in design of axial-flow compressors. Enables design engineer to study relationships among number of stages, flow-path radii, gas velocities, flow angles, and resultant variation of compressor efficiency. Rapidly provides conceptual designs for preliminary design studies of air-breathing engines. Written in FORTRAN 77.

Glassman, Arthur J.↗