Simultaneous evaluation of acoustic nonlinearity parameter and attenuation coefficients using the finite amplitude method

A novel method to determine acoustic parameters involved in measuring the nonlinearity parameter of fluids or solids is proposed. The approach is based on the measurement of fundamental and second harmonic pressures with a calibrated receiver, and on a nonlinear least squares data-fitting to multi-Gaussian beam (MGB) equations which explicitly define the attenuation and diffraction effects in the quasilinear regime. Results obtained in water validate the proposed method. The choice of suitable source pressure is discussed with regard to the quasilinear approximation involved. The attenuation coefficients are also acquired in nonlinear regime and their relations are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of tritium with plastic scintillator surface improvement with plasma treatment

Tritium is usually measured by using a liquid scintillation counter. However, liquid scintillator used for measurement will become radioactive waste fluid. To solve this issue, we have developed a method of measuring tritium samples with plasma-treated plastic scintillator (PS)sheets (Plasma method). The radioactive sample is held between 2 PS sheets and the whole is enclosed in a a low-potassium glass vial. With the Plasma method of 2-min plasma treatment, we have obtained measurement efficiency of 48 ± 2 % for 2 min measurement of tritium except for tritiated water. The plasma treatment makes the PS surface rough and hydrophilic which contributes to improve the contact between tritium and PS. On the other hand, it needed almost 6 hours to obtain constant measurement efficiency. The reason was that the dry-up handling in the vial needed longer time to vaporize H{sub 2}O molecules than in the air. We tried putting silica gel beads into vials to remove H{sub 2}O molecules from PS sheet surface quickly. The silica gel beads worked well and we got constant measurement efficiency within 1-3 hours. Also, we tried using other kinds of PS treated with plasma to obtain higher measurement efficiencies of tritium samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microfluidic devices, systems, and methods for quantifying particles using centrifugal force

Embodiments of the present invention are directed toward microfluidic systems, apparatus, and methods for measuring a quantity of cells in a fluid. Examples include a differential white blood cell measurement using a centrifugal microfluidic system. A method may include introducing a fluid sample containing a quantity of cells into a microfluidic channel defined in part by a substrate. The quantity of cells may be transported toward a detection region defined in part by the substrate, wherein the detection region contains a density media, and wherein the density media has a density lower than a density of the cells and higher than a density of the fluid sample. The substrate may be spun such that at least a portion of the quantity of cells are transported through the density media. Signals may be detected from label moieties affixed to the cells.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Laser induced fluorescence measurements of ion velocity and temperature of drift turbulence driven sheared plasma flow in a linear helicon plasma device

Using laser induced fluorescence (LIF), radial profiles of azimuthal ion fluid velocity and ion temperature are measured in the controlled shear de-correlation experiment (CSDX) linear helicon plasma device. Ion velocities and temperatures are derived from the measured Doppler broadened velocity distribution functions of argon ions. The LIF system employs a portable, high power (>300 mW), narrowband ({approx}1 MHz) tunable diode laser-based system operating at 668.614 nm. Previous studies in CSDX have shown the existence of a radially sheared azimuthal flow as measured with time delay estimation methods and Mach probes. Here, we report the first LIF measurements of sheared plasma fluid flow in CSDX. Above a critical magnetic field, the ion fluid flow profile evolves from radially uniform to peaked on axis with a distinct reversed flow region at the boundary, indicating the development of a sheared azimuthal flow. Simultaneously, the ion temperature also evolves from a radially uniform profile to a profile with a gradient. Measurements in turbulent and coherent drift wave mode dominated plasmas are compared.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computational Fluid Dynamics Analysis of the Molten Salt Tritium Transport Experiment Test Section

Tritium, a radionuclide produced through neutron capture by lithium and other elements (beryllium and fluoride) in molten salts, presents unique challenges to radionuclide release. This is true for both fusion energy breeder blankets and molten salt fission reactors. The fundamental understanding of tritium transport is crucial to the safe design and operation of these reactors. The Molten Salt Tritium Transport Experiment (MSTTE), currently under construction at Idaho National Laboratory, aims to investigate tritium transport phenomena using a forced-convection fluoride salt loop. This loop is designed to study various transport mechanisms, such as permeation through metals and gas-liquid interactions, and is intended to support future research on tritium extraction units. A critical aspect of the MSTTE loop design is ensuring a fully developed velocity profile before the fluid reaches the permeation test section where measurements are made. This study employs computational fluid dynamics to model the salt flow behavior within the MSTTE permeation test section. A realizable k-ε turbulent model with enhanced wall treatment is used to simulate the single-phase, vertical upward flow of molten salt FLiNaK under isothermal conditions. The simulation results indicated flow distortion and underdeveloped profiles at all planned flow rates within the test section due to the 85-deg sharp bend. To address this issue, a reduced diameter with a reducer and expander and a flow conditioner are investigated to achieve fully developed flow. The analysis showed that the flow conditioner successfully corrected the flow profile, achieving fully developed behavior at a flow rate of 50 liters per minute (LPM). In conclusion, this research enhances our understanding of flow dynamics in molten salt systems and contributes to optimizing tritium transport control technologies.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Measurement of the onset of nucleate boiling in liquid xenon

We report the first precision measurement of the superheat temperature required for bubble nucleation in liquid xenon of Δ T wall,ONB = (16.9±0.5) K and Δ T wall,ONB = (19.2 +0.4 -1.1 ) K at pressures of P = (0.98±0.02) bar and P = (1.32 +0.05 -0.01 ) bar, respectively. Both are measured at a subcooled bulk fluid temperature of ~ 162 K. A dedicated liquid xenon setup is used to measure the temperature at which bubble nucleation first appears on the flat surface of a resistor. The associated average heat flux at the surface of the resistor is determined using fluid dynamics simulations. Future experiments can use these experimental results to determine the likelihood of boiling in liquid xenon and to design effective thermal sinks that prevent bubble nucleation.

47 OTHER INSTRUMENTATION↗

Prediction of a measurable sign change in the Casimir force using a magnetic fluid

Here, we demonstrate quantum levitation controlled by Casimir forces acting between a polystyrene surface and a Teflon-coated metallic substrate immersed in a mixture of toluene and magnetite particles. This system experiences repulsion-attraction transitions in the Casimir interaction for distances where the effect is measurable. This Casimir trapping can be controlled by clever choices of metallic and ferrofluid materials, which are directly linked to the emergence of the trapping effect. Thermal and quantum contributions are investigated in detail, showing how the optical and magnetic properties of the ferrofluid and other materials affect the magnitude of the trapping and its distance range of observability.

Ma, Long [University of South Florida, Tampa, FL (↗

Mapping of exhaust gas recirculation and combustion-residual backflow in the intake ports of a heavy-duty diesel engine using a multiplexed multi-species absorption spectroscopy sensor [Mapping of EGR and combustion residual backflow in the intake ports of a heavy duty diesel engine using a multiplexed multi-species absorption spectroscopy sensor]

Here, the combustion-residual backflow into the intake ports of a commercial diesel engine (Cummins ISX series) was spatiotemporally mapped using a multiplexed multi-species absorption spectroscopy sensor system; the resulting cycle- and cylinder-resolved measurements are applicable for assessing cylinder charge uniformity, control strategies, and computational fluid dynamics tools. On-engine measurements were made using four compact (3/8 in Outside Diameter) stainless steel probes which enabled simultaneous multi-point measurements, required minimal engine hardware modification, and featured a novel tip design for measurement of gas flows parallel to the probe axis. Three sensor probes were used to perform simultaneous backflow measurements in intake runners corresponding to three of the six engine cylinders, and a fourth probe was installed in the intake manifold plenum for tracking dynamics introduced by an external exhaust gas recirculation mixer. Near-crank-angle resolved measurements (5 kHz, that is, 1.2 crank angle resolution at 1000 RPM) were performed during steady-state engine operation at various levels of external exhaust gas recirculation to measure the gas properties and penetration distance of the backflow into the intake runners on a cylinder- and cycle-basis. Validation of computational fluid dynamics model results is also presented to demonstrate the utility of such measurements in advancing engine research.

33 ADVANCED PROPULSION SYSTEMS↗

Mass measurement systems and related methods for measuring mass of solids within a liquid

A measurement system includes a vessel for containing a fluid and at least one solid material and a probe assembly for disposing partially into the fluid within the vessel. The probe assembly includes a hollow tube having an open lower longitudinal end and at least one pressure sensor within the hollow tube, the at least one pressure sensor configured to measure pressures of the fluid within the hollow tube at at least two different elevations. A method of measuring a mass of suspended solids within a fluid, the method includes receiving pressure measurements representing two different elevations of the fluid within a hollow tube and substantially free of the suspended solids and based at least partially on the received pressure measurements, determining a mass of the suspended solids.

Galbreth, Gregory G.↗

Use of a multichannel collimator for structural investigation of low-Z dense liquids in a diamond anvil cell: Validation on fluid H{sub 2} up to 5 GPa

We report the first application of a multichannel collimator (MCC) to perform quantitative structure factor measurements of dense low-Z fluids in a diamond anvil cell (DAC) using synchrotron x-ray diffraction. The MCC design, initially developed for the Paris-Edinburgh large volume press geometry, has been modified for use with diamond anvil cells. A good selectivity of the diffracted signal of the dense fluid sample is obtained due to a large rejection of the Compton diffusion from the diamond anvils. The signal to background ratio is significantly improved. We modify previously developed analytical techniques for quantitative measurement of the structure factor of fluids in DACs [J. H. Eggert, G. Weck, P. Loubeyre, and M. Mezouar, Phys. Rev. B 65, 174105 (2002)] to account for the contribution of the MCC. We present experimental results on liquids argon and hydrogen at 296 K to validate our method and test its limits, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deflection Shape Reconstructions of a Rotating Five-blade Helicopter Rotor from TLDV Measurements

Helicopters are aircraft machines which are subjected to high level of vibrations, mainly due to spinning rotors. These are made of two or more blades attached by hinges to a central hub, which can make the dynamic behaviour difficult to study. However, they share some common dynamic properties with the ones expected in bladed discs, thereby the analytical modelling of rotors can be performed using some assumptions as the ones adopted for the bladed discs. This paper presents results of a vibrations study performed on a scaled helicopter rotor model which was rotating at a fix rotational speed and excited by an air jet. A simplified analytical model of that rotor was also produced to help the identifications of the vibration patterns measured using a single point tracking-SLDV measurement method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and characterization of liquid argon and methane microjets for high-rep-rate laser-plasma experiments

A cryogenic microjet system has been used here for delivering micron-scale continuous liquid hydrogen targets for laser-plasma experiments. This technique has been extended to higher-Z, higher boiling-point gases, including argon and methane. High-resolution shadowgraphy has been used to characterize the jet’s morphology and pointing stability. A split and delay illumination source has also been developed for direct measurement of jet speeds without relying on assumptions of fluid flow conditions. Under typical conditions, the argon jets freeze solid due to evaporative cooling, but the methane jets remain liquid and break up to a droplet stream. A piezo driver is used to ensure the droplets are of uniform size. This jet has enabled the investigation of methane in planetary core conditions with high-rep-rate laser heating and x-ray laser probing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using high-fidelity computational fluid dynamics to help design a wind turbine wake measurement experiment

Here, we describe the process of using large-eddy simulations of wind turbine wake flow to help design a wake measurement campaign. The main goal of the experiment is to measure wakes and wake deflection that result from intentional yaw misalignment under a variety of atmospheric conditions at the Scaled Wind Farm Technology facility operated by Sandia National Laboratories in Lubbock, Texas. Prior simulation studies have shown that wake deflection may be used for wind-plant control that maximizes plant power output. In this study, simulations are performed to characterize wake deflection and general behavior before the experiment is performed to ensure better upfront planning. Beyond characterizing the expected wake behavior, we also use the large-eddy simulation to test a virtual version of the lidar we plan to use to measure the wake and better understand our lidar scan strategy options. This work is an excellent example of a 'simulation-in-the-loop' measurement campaign.

17 WIND ENERGY↗

Hypersonic Fluid–Structure Interaction on a Cone–Slice–Ramp Geometry

In this study, fluid–structure interactions were measured between a representative control surface and the hypersonic flow deflected by it. The control surface is simplified as a spanwise finite ramp placed on a longitudinal slice of a cone. The front surface of the ramp contains a thin panel designed to respond to the unsteady fluid loading arising from the shock-wave/boundary-layer interactions. Experiments were conducted at Mach 5 and Mach 8 with ramps of different angles. High-speed schlieren captured the unsteady flow dynamics and accelerometers behind the thin panel measured its structural response. Panel vibrations were dominated by natural modes that were excited by the broadband aerodynamic fluctuations arising in the flowfield. However, increased structural response was observed in two distinct flow regimes: 1) attached or small separation interactions, where the transitional regime induced the strongest panel fluctuations. This was in agreement with the observation of increased convective undulations or bulges in the separation shock generated by the passage of turbulent spots, and 2) large separated interactions, where shear layer flapping in the laminar regime produced strong panel response at the flapping frequency. In addition, panel heating during the experiment caused a downward shift in its natural mode frequencies.

33 ADVANCED PROPULSION SYSTEMS↗

Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies

This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need for new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.

42 ENGINEERING↗

Insights into mixing of non-isothermal multi-polymer melts for complex plastics recycling

Catalytic recycling or upcycling of plastics is often limited not by catalyst performance, but by transport, arising from highly viscous, non-Newtonian polymer melts. In this work, we develop a reactor-scale framework that integrates rheological measurements, constitutive modeling, computational fluid dynamics (CFD), and experiments to quantify mixing, heat transfer, and dispersion in surrogate hydrocarbon melts representing mixed plastics systems. Temperature- and shear rate-dependent viscosity of low-density polyethylene (LDPE) and high-density polyethylene (HDPE) is measured to create two surrogate polymers (PLD and PHD) that capture the dominant shear-thinning flow behavior while neglecting strong elastic effects, enabling tractable simulation of non-isothermal, polymer-melt mixing using a Carreau-Arrhenius generalized Newtonian framework. Three-dimensional CFD simulations are employed to evaluate impeller performance in PLD using mixing time, cavern volume, thermal uniformity, and interfacial area for regimes in which viscoelastic effects are not dominant. We show that magnetic stir bars commonly used in lab-scale studies produce large thermal gradients (~60 °C) and poor mixing, even under idealized power delivery and polymer flow conditions. In contrast, close-clearance anchor impellers achieve near-isothermal operation, reduce mixing times by up to 5×, and provide >90% active circulation volume. We further demonstrate that, at low pseudo-Deborah number (De*), motor power requirements can be predicted directly from shear rate-dependent rheology using the Carreau-Arrhenius framework, enabling rational selection of operating conditions. Extension to surrogate immiscible multi-polymer systems based on PLD and PHD shows that interfacial area is highly sensitive to operating conditions and impeller design, with coaxial anchor-turbine configurations enhancing dispersion by up to 4 × .

Close-clearance impellers↗