Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Ultrastable reference frequency distribution utilizing a fiber optic link

The Frequency Standards Laboratory at the Jet Propulsion Laboratory (JPL) is responsible for the generation and distribution of ultra-stable reference frequency in NASA's Deep Space Network (DSN). Certain assemblies and components of the Radio Science and VLBI systems are located in the cones of tracking antennas hundreds of meters from the Frequency and Timing Subsystem's frequency standards. The very stringent requirements of these users challenge the performance of state-of-the-art frequency sources as well as the associated signal distribution system. The reference frequency distribution system described is designed around a low temperature coefficient of delay (TCD) optical fiber. On-site measurements of the fiber optic link alone indicate 100 MHz phase noise performance on the order of -120 dBc at 1 Hz from the carrier and Allan deviation on the order of parts in 10(exp 16) at 1000 seconds averaging time. The measured phase noise and stability of the link indicate that the performance characteristics of the hydrogen maser frequency standards are not degraded by the distribution system. Thus, optical fibers and electro-optic devices as distribution media appear to be a viable alternative to the classical coaxial cable distribution systems.

Calhoun, Malcolm↗

Long term frequency stability analysis of the GPS NAVSTAR 6 Cesium clock

Time domain measurements, taken between the NAVSTAR 6 Spacecraft Vehicle (SV) and the Vandenberg Global Positioning System (GPS) Monitor Site, by a pseudo random noise receiver, were collected over an extended period of time and analyzed to estimate the long term frequency stability of the NAVSTAR 6 onboard frequency standard, referenced to the Vandenberg MS frequency standard. The technique employed separates the clock offset from the composite signal by first applying corrections for equipment delays, ionospheric delay, tropospheric delay, Earth rotation and the relativistic effect. The data are edited and smoothed using the predicted SV ephemeris to calculate the geometric delay. Then all available passes from each of the four GPS monitor stations, are collected at 1-week intervals and used to calculate the NAVSTAR orbital elements. The procedure is then completed by subtracting the corrections and the geometric delay, using the final orbital elements, from the composite signal, thus leaving the clock offset and random error.

Mccaskill, T. B.↗

Coherence limits for very-long-baseline interferometry

The quality of the frequency standards used in very-long-baseline interferometry (VBLI) limits the coherent integration time and the accuracy of geodetic experiments except in special cases when clock instabilities can be made to cancel out by using differential interferometry. Formulas are derived for estimating the coherence of these interferometers from the Allan variances of the frequency standards. Experiments using extremely high-quality frequency standards, such as hydrogen masers, may be limited by the phase noise that results from atmospheric and ionospheric fluctuations.

Rogers, A. E. E.↗

Radiofrequency synthesiser with an intrinsic instability of 5 × 10{sup −15} at the averaging time of 1 s based on a femtosecond erbium-doped fibre laser

A radio-optical synthesiser intended for operation in a radio-frequency master oscillator with an optical He – Ne/CH{sub 4} frequency standard (λ = 3.39 μm) is developed on the basis of a femtosecond erbium-doped fibre laser. The synthesiser generates equidistant harmonics in the frequency range of 1 – 10 GHz with stability determined by the optical frequency standard. A stable supercontinuum spectrum is formed in the range around 1.06 μm, which provides stable 24-hour operation of the synthesiser and is important for practical applications in off-laboratory conditions. A direct comparison of the output frequencies of two synthesisers shows that the up-grade of the fibre laser and detection system of femtosecond pulses results in the synthesiser intrinsic instability of 5 × 10{sup −15} at the averaging time of 1 s. Such a value is by an order of magnitude less than that obtained in our earlier works. (laser frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spaceborne clock system: Some alternatives for a proposed NASA experiment

A spaceborne clock experiment is proposed with the objectives of improving international time and frequency comparisons, studying precise one-way Doppler tracking and one-way ranging techniques, performing relativistic studies, and developing new atomic frequency standards technology. Various alternatives are considered for accomplishing these goals, including the use of existing satellite and earth-based time dissemination systems as well as the development of a new frequency standard for this specific application. One conclusion is that several attractive alternatives already exist for meeting the goal of improved time and frequency dissemination. However, to achieve all the other 4 goals at the NASA-stated levels of accuracy, a spaceborne atomic frequency standard may be required. An analysis of achievements to date with quartz oscillators, rubidium standards, cesium beam standards, hydrogen masers, and several other possibilities leads to the conclusion that cesium and rubidium standards offer the best choices for the experiment as proposed by NASA. The greatest obstacle to a spaceborne atomic standard appears to be its electrical power requirements.

Beehler, R. E.↗

GPS Block 2R Time Standard Assembly (TSA) architecture

The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

Baker, Anthony P.↗

Operating and environmental characteristics of Sigma Tau hydrogen masers used in the Very Long Baseline Array (VLBA)

Presented here are the results obtained from performance evaluation of a pair of Sigma Tau Standards Corporation Model VLBA-112 active hydrogen maser frequency standards. These masers were manufactured for the National Radio Astronomy Observatory (NRAO) for use on the Very Long Baseline Array (VLBA) project and were furnished to the Jet Propulsion Laboratory (JPL) for the purpose of these tests. Tests on the two masers were performed in the JPL Frequency Standards Laboratory (FSL) and included the characterization of output frequency stability versus environmental factors such as temperature, humidity, magnetic field, and barometric pressure. The performance tests also included the determination of phase noise and Allan variance using both FSL and Sigma Tau masers as references. All tests were conducted under controlled laboratory conditions, with only the desired environmental and operational parameters varied to determine sensitivity to external environment.

Tucker, T. K.↗

Recent progress in the NASA-Goddard Space Flight Center atomic hydrogen standards program

At NASA Goddard Space Flight Center and through associated contractors, a broad spectrum of work is being carried out to develop improved hydrogen maser frequency standards for field use, improved experimental hydrogen maser frequency standards, and improved frequency and time distribution and measurement systems for hydrogen maser use. Recent progress in the following areas is reported: results on the Nr masers built by the Applied Physics Laboratory of Johns Hopkins University, the development of a low cost hydrogen maser at Goddard Space Flight Center, and work on a low noise phase comparison system and digitally phase locked crystal oscillator called the distribution and measurement system.

Reinhardt, V. S.↗

Precision frequency synthesizing sources with excellent time/frequency performances

Precision frequency synthesizing sources are needed in the time / frequency measuring system, atomic frequency standards, telemetry, communication, and radar systems. This kind of frequency synthesizing source possesses high frequency accuracy and excellent long term and short term frequency stability. Several precision frequency synthesizing sources developed by Beijing Institute of Radio Metrology and Measurement (BIRMM) which have been successfully applied to the time / frequency measuring system, atomic frequency standards system, and radar system are described. In addition, the working principle, implementation approach, and the main technical specifications of the frequency synthesizing sources are also given.

Zhou, Liren↗

Frequency and time standards based on stored ions

The method of ion storage provides a basis for excellent time and frequency standards. This is due to the ability to confine ions for long periods of time without the usual perturbations associated with confinement (e.g., wall shifts). In addition, Doppler effects can be greatly suppressed. The use of stored ions for microwave frequency standards and the future possibilities for an optical frequency standard based on stored ions are addressed.

Bollinger, J. J.↗

Limitations on long-term stability and accuracy in atomic clocks

The limits to accuracy and long term stability in present atomic clocks are examined. Recent proposals for new frequency standards are discussed along with the advantages and disadvantages of frequency standards based on such ideas as laser transitions, single atoms, and atom cooling. The applicability of some of these new techniques to existing standards is examined.

Wineland, D. J.↗

229Th the Bridge Between Nuclear and Atomic Interactions

The precise measurement of time has been a goal of physicists for centuries. With every new increase in our ability to measure time we have discovered new phenomena. The most advanced clocks available to us currently are atomic clocks that use electronic transitions to track the passage of time. In this proposal, I put forward the framework for the first nuclear clock estimated to be 1000 to 10000 times more precise than the current atomic clocks. This research will explore in detail the atomic nuclear interactions and help perfect and refine current atomic-nuclear interaction models. The realization of a {sup 229}Th nuclear clock will allow tests of cosmology by measuring the change of the fine structure constant as a function of time. The results of these experiments could dramatically alter our view of the universe, its past and future evolution. Precision clocks - with fundamental physics applications - require a long-lived quantum transition (two-level system) that is immune to external perturbations. Nuclear transitions would be better suited than atomic transitions for these applications except that nuclear transitions are typically much higher in energy and therefore cannot be accessed with table-top lasers. There is, however, one promising nuclear transition: the doublet between the ground and first excited states of the {sup 229}Th nucleus discovered by Helmer and Reich. This doublet has an energy splitting of 7.6 {+-} 0.5 eV, a spin difference of 1 h-bar, and an excited state half-life that could be as long as hours. A precision clock based on the {sup 229}Th nuclear doublet has been proposed by Peik et al. Their design is similar to the ion clock research being conducted at NIST in Boulder, CO. However, the NIST researchers use atomic transitions for their frequency standards. In the {sup 229}Th nuclear doublet transition is the frequency standard while atomic transitions are used to cool the ions and for probing the state of the {sup 229}Th nucleus. Recently, Campbell et al. have trapped and cooled {sup 232}Th{sup 3+} at Georgia Institute of Technology. This is a large step forward in the realization of a nuclear clock. The Georgia Tech group is already a collaborator on this project and we are in discussions with the NIST Boulder group about collaboration. In order to determine the suitability of the {sup 229}Th nuclear doublet for a precision clock, the half-life of the excited-state needs to be measured. Current estimates of the half-life vary from 10 {micro}s to 1000 hours. The longer the half-life, the narrower the natural linewidth of the state and the more desirable the transition is for potential applications. In this proposal, I outline the necessary research to be conducted to determine the half-life and exact wavelength of the nuclear doublet transition in {sup 229}Th. This research will lead to a deeper understanding of atomic-nuclear interactions important for our knowledge of high energy density science. It will provide a spectroscopy measurement of the lowest known nuclear transition ever and open the doorway for the development of a nuclear clock with unprecedented precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UTC Dissemination to the Real-Time User

The current definition of Coordinated Universal Time (UTC) dates from 1972. The duration of a UTC second is defined in terms of the frequency of a hyperfine transition in the ground state of cesium. This standard frequency is realized in a number of different laboratories using ensembles of commercial cesium clocks and a few primary frequency standards. The data from all of these devices are transmitted periodically to the Bureau International des Poids et Mesures (BIPM) in Sevres, France, where they are combined in a statistical procedure to produce International Atomic Time (TAI). The time of this scale is adjusted as needed ('coordinated') by adding or dropping integer seconds so as to keep it within plus or minus 0.9 s of UT1, a time scale based on the observation of the transit times of stars and corrected for the predicted seasonal variations in these observations. When the leap seconds are included into TAI, the result is called UTC. The difference between TAI and UTC is therefore an exact integer number of seconds. This difference is currently 29 s and will become 30 s at 0 UTC on 1 January 1996.

Levine, Judah↗

Hydrogen Maser Clock (HMC) Experiment

The Hydrogen Maser Clock (HMC) project was originally conceived to fly on a reflight of the European Space Agency (ESA) free flying platform, the European Recoverable Carrier (EURECA) that had been launched into space and recovered by NASA's Space Transportation System (STS). A Phase B study for operation of HMC as one of the twelve EURECA payload components was begun in July 1991, and completed a year later. Phase C/D of HMC began in August 1992 and continued into early 1995. At that time ESA decided not to refly EURECA, leaving HMC without access to space. Approximately 80% of the flight support electronics are presently operating the HMC's physics package in a vacuum tank at the Smithsonian Astrophysical Observatory, and are now considered to be well-tested flight electronics. The package will continue to be operated until the end of 1997 or until a flight opportunity becomes avaiable. Appendices: letters and trip report; proceedings of the symposium on frequency standards and metrology; milli-celsius-stability thermal control for an orbiting frequency standard.

Vessot, Robert F. C.↗

A potential new test for unseen matter in the outer solar system

The recent development of trapped-ion frequency standards, which offer high stability over long time periods, provides us with a potential new method for detecting unseen matter in the outer solar system. A distribution of matter or a planetary body could produce a measurable gravitational redshift of the radio signal received from a spacecraft equipped with an ultrastable frequency standard. Trapped-ion standards have a potential frequency stability of 1 part in 10(exp 16) or better over long time periods (greater than 10(exp 6) s). We consider the potential improvements this method could yield over conventional dynamical tests for unseen matter in the outer solar system possible now or anticipated in the near future.

Krisher, Timothy P.↗

NASA atomic hydrogen standards program: An update

Comparisons are made between the NP series and the NX series of hydrogen masers. A field operable hydrogen maser (NR series) is also described. Atomic hydrogen primary frequency standards are in development stages. Standards are being developed for a hydrogen beam frequency standard and for a concertina hydrogen maser.

Reinhardt, V. S.↗

Atomic Clock Based On Linear Ion Trap

Highly stable atomic clock based on excitation and measurement of hyperfine transition in 199Hg+ ions confined in linear quadrupole trap by radio-frequency and static electric fields. Configuration increases stability of clock by enabling use of enough ions to obtain adequate signal while reducing non-thermal component of motion of ions in trapping field, reducing second-order Doppler shift of hyperfine transition. Features described in NPO-17758 "Linear Ion Trap for Atomic Clock." Frequency standard based on hyperfine transition described in NPO-17456, "Trapped-Mercury-Ion Frequency Standard."

Prestage, John D.↗

The Rubidium-Crystal Oscillator Hybrid Development Program

The rubidium-crystal oscillator hybrid (RbXO) will make precise time available to systems that lack the power required by atomic frequency standards. The RbXO consists of two subassemblies in separate enclosures. One contains a small rubidium frequency standard (RFS) without its internal oven-controlled crystal oscillator (OCXO), plus interface circuits. The second contains a low-power OCXO, and additional interface circuits. The OCXO is on continuously. Periodically, e.g., once a week, the user system applies power to the RFS. After the few necessary for the warmup of the RFS, the interface circuits adjust the frequency of the OCXO to the RFS reference, then shut off the RFS. The OCXO enclosure is separable from the RFS enclosure so that manpacks will be able to operate with minimum size, weight, and power consumption, while having the accuracy of the RFS for the duration of a mission. A prototype RbXO's RFS has operated successfully for 4200 on-off cycles. Parallel efforts on a Phase 2 RbXO development are in progress. Two sources for the RbXO are scheduled to be available during 1986.

Vig, J. R.↗