Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements

Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

Wang, H. T.↗

Historical Cost Curves for Hydrogen Masers and Cesium Beam Frequency and Timing Standards

Historical cost curves were developed for hydrogen masers and cesium beam standards used for frequency and timing calibration in the Deep Space Network. These curves may be used to calculate the cost of future hydrogen masers or cesium beam standards in either future or current dollars. The cesium beam standards are decreasing in cost by about 2.3% per year since 1966, and hydrogen masers are decreasing by about 0.8% per year since 1978 relative to the National Aeronautics and Space Administration inflation index.

Remer, D. S.↗

Opto-Electronic Oscillator Stabilized By A Hyperfine Atomic Transition

Opto-electronic oscillator (OEO) is a closed-loop system with part of the loop is implemented by an optical beam, and the rest by RF circuitry. The technological advantage of this approach over traditional all-RF loops in the gigahertz range comes from the that frequency filtering can be done far more efficiently in the optical range with compact, low power, and have superior stability. In this work, we report our preliminary results on using the phenomenon of coherent population trapping in (87) Rb vapor as an optical filter. Such a filter allows us to stabilize the OEO at the hyperfine splitting frequency of rubidium, thus implementing a novel type of frequency standard.

OEO (OPTO-ELECTRONIC OSCILLATORS)↗

Design concept for the microwave interrogation structure in PARCS

In this paper we will describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the Primary Atomic Reference Clock in Space (PARCS) experiment.

frequency standard phase shift microwave cavity↗

Data acquisition and editing for the celestial mechanics experiment

A radio tracking subsystem is reported in which the critical elements are the frequency standard and its distribution subsystem, as they ultimately limit the accuracy of both range and Doppler measurements. A rubidium vapor standard serves as the primary reference. After frequency multiplication to S-band and additional amplification, the carrier is transmitted to the spacecraft where a phase-locked receiver-transmitter system filters the signal, introduces a slight frequency shift, and retransmits it to the ground. Doppler is measured by comparing the received frequency with that being transmitted.

Martin, W. L.↗

Flexible bulb large storage box hydrogen maser

The principal limitation on the accuracy of the hydrogen maser as a primary frequency standard has been the irreproducibility of the frequency shift caused by collisions of the radiating atoms with the walls of the vessel containing them. The flexible bulb-large storage box hydrogen maser allows correction for this wall shift within a single device, sidestepping the reproducibility problem, and reducing the frequency error from the wall shift to the level imposed by the device's stability. The principles of the device are discussed including the flexible bulb technique and the complications caused by a multiple region storage bulb. The stability of the device is discussed including a comparison with an ordinary hydrogen maser. Data is presented from a working flexible bulb-large storage box hydrogen maser demonstrating the feasibility of the device and showing some of its operating characteristics. The flexibility of the device is demonstrated by showing how the device's added degrees of freedom allow measurement of parameters unmeasurable in an ordinary hydrogen maser.

Reinhardt, V.↗

Experimental optical fiber communications link

An optical fiber communications link 1.5 kilometers in length was installed between the Interim Frequency Standard Test Facility and the Timing and Frequency Systems Research Laboratory at JPL. It is being used to develop optical fiber technology for use in the DSN and particularly for precise time and frequency distribution.

Lutes, G. F.↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

The trapped ytterbium ion frequency standard under development at JPL is designed to supply ultra-stable reference signals to be used in spacecraft tests of general relativity and other science experiments. Only diode lasers meet the requirements of low power comsumption and small size for use aboard spacecraft, but diode lasers are not currently available at 369.4 nm wavelength. It is therefore necessary to employ frequency doubling methods to reach this frequency with diode lasers. Here we present the characteristics of the resonant cavity doubling system we have designed and preliminary UV conversion results.

ultra-stable↗

Relationships Between the Performance of Time/Frequency Standards and Navigation/Communication Systems

The relationship between system performance and clock or oscillator performance is discussed. Tradeoffs discussed include: short term stability versus bandwidth requirements; frequency accuracy versus signal acquisition time; flicker of frequency and drift versus resynchronization time; frequency precision versus communications traffic volume; spectral purity versus bit error rate, and frequency standard stability versus frequency selection and adjustability. The benefits and tradeoffs of using precise frequency and time signals are various levels of precision and accuracy are emphasized.

Hellwig, H.↗

Design of the stift time and frequency transfer microwave ground terminal

The Satellite Time and Frequency Transfer System is intended to provide, simultaneously, global time comparisons at the subnanosecond level and frequency comparisons to better than 1 part in 10 to the 14th power. It utilizes an orbiting hydrogen maser clock and frequency standard that communicates, via microwave links, time and frequency information to Earth terminals operated by hydrogen masers controlling local clocks. A two-way microwave link, to and from the space vehicle provides Doppler information used to cancel the Doppler shifts in a one-way link from the spaceborne oscillator. Pseudo-random noise (PRN) modulation in the two-way link also provides range information to cancel the range delay in the PRN time transfer between space and Earth. The pseudo-random noise modulation system for time difference measurement and its incorporation in the Doppler cancellation system for frequency comparison is explained. The particular PRN code sequence selected and an analysis of the system is discussed.

Penfield, H.↗

Linear Ion Trap For Atomic Clock

Linear, radio-frequency ion trap increases frequency stability of atomic frequency standard device. Confines ions with less radio-frequency motion than does point ion trap.

Prestage, John D.↗

Allan deviation computations of a linear frequency synthesizer system using frequency domain techniques

Allan Deviation computations of linear frequency synthesizer systems have been reported previously using real-time simulations. Even though it takes less time compared with the actual measurement, it is still very time consuming to compute the Allan Deviation for long sample times with the desired confidence level. Also noises, such as flicker phase noise and flicker frequency noise, can not be simulated precisely. The use of frequency domain techniques can overcome these drawbacks. In this paper the system error model of a fictitious linear frequency synthesizer is developed and its performance using a Cesium (Cs) atomic frequency standard (AFS) as a reference is evaluated using frequency domain techniques. For a linear timing system, the power spectral density at the system output can be computed with known system transfer functions and known power spectral densities from the input noise sources. The resulting power spectral density can then be used to compute the Allan Variance at the system output. Sensitivities of the Allan Variance at the system output to each of its independent input noises are obtained, and they are valuable for design trade-off and trouble-shooting.

Wu, Andy↗

Two-frequency sub-Doppler spectroscopy of the caesium D{sub 1} line in various configurations of counterpropagating laser beams

Sub-Doppler resonances in caesium vapours are studied in a laser field produced by counterpropagating two-frequency light beams with mutually orthogonal linear polarisations. The beams are in resonance with optical transitions in the D{sub 1} line, the frequency difference of the field spectral components being equal to the hyperfine ground-state splitting in the Cs atom (∼9.2 GHz). It has already been shown that in this configuration, the hypercontrast effect can be observed for sub-Doppler resonances, which makes this configuration promising for the employment in new-generation miniature optical frequency standards. In the present work, two different two-frequency configurations are compared with each other and with the single-frequency configuration widely used in practice for observing saturated absorption resonances. The parameters of nonlinear resonances are measured at various temperatures of caesium vapours and at different optical field intensities. The results of the investigations performed make it possible to find an optimal two-frequency scheme for exciting nonlinear resonances and to estimate a potential of the scheme for its applications in quantum metrology. (laser spectroscopy of atoms)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 100-kHz frequency divider, distribution amplifier

A frequency divider, distribution amplifier module having low phase noise and low phase drift with temperature and high isolation between outputs was developed for use in the hydrogen maser frequency standard, where it divides 1 MHz from the previous frequency divider down to 100 kHz and provides four transistor-transistor logic (TTL) outputs.

Lutes, G.↗

Highly Stable Microwave Resonator

Superconducting walls on sapphire-filled cavity make low-loss device. Improved microwave resonant cavity consists of sapphire cylinder coated with thin film of superconducting lead. Operated well below superconducting transition temperature at 1.5K, cavity demonstrated superior frequency stability and quality factor. Cavity frequency highly stable and therefore suitable for use in standard frequency generators and filters.

Strayer, Donald M.↗

Designing for Flight Through Periods of Instability

For completeness, it is imperative that Flight Control System (FCS) designers use both complementary time and frequency domain techniques to address periods of instability. Use of standard frequency domain synthesis techniques alone may not always yield an FCS design with sufficient gain and phase stability robustness margins while simultaneously satisfying performance requirements.

Designing for Flight↗