Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

A test on reactive force fields for the study of silica dimerization reactions

We studied silica dimerization reactions in the gas and aqueous phase by density functional theory (DFT) and reactive force fields based on two parameterizations of ReaxFF. For each method (both ReaxFF force fields and DFT), we performed constrained geometry optimizations, which were subsequently evaluated in single point energy calculations using the other two methods. Standard fitting procedures typically compare the force field energies and geometries with those from quantum mechanical data after a geometry optimization. The initial configurations for the force field optimization are usually the minimum energy structures of the ab initio database. Hence, the ab initio method dictates which structures are being examined and force field parameters are being adjusted in order to minimize the differences with the ab initio data. As a result, this approach will not exclude the possibility that the force field predicts stable geometries or low transition states which are realistically very high in energy and, therefore, never considered by the ab initio method. Our analysis reveals the existence of such unphysical geometries even at unreactive conditions where the distance between the reactants is large. To test the effect of these discrepancies, we launched molecular dynamics simulations using DFT and ReaxFF and observed spurious reactions for both ReaxFF force fields. Our results suggest that the standard procedures for parameter fitting need to be improved by a mutual comparative method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thiokol/Wasatch installation evaluation of the redesigned field joint protection system (concepts 1 and 3)

The procedures, performance, and results obtained from the Thiokol Corporation/Wasatch Redesigned Field Joint Protection System (FJPS) Installation Evaluation are documented. The purpose of the evaluation was to demonstrate and develop the procedures required to install two different concepts (referred to as Concepts 1 and 3) of the redesigned FJPS. The processing capability of each configuration was then evaluated and compared. The FJPS is installed on redesigned solid rocket motors (RSRM) to protect the field joints from rain intrusion and to maintain the joint temperature sensor measurement between 85 and 122 F while the boosters are on the launch pad. The FJPS is being redesigned to reduce installation timelines at KSC and to simplify or eliminate installation processing problems related to the present design of an EPDM moisture seal/extruded cork combination. Several installation techniques were evaluated, and a preferred method of application was developed for each concept. The installations were performed with the test article in the vertical (flight) position. Comparative timelines between the two concepts were also developed. An additional evaluation of the Concept 3 configuration was performed with the test article in the horizontal position, to simulate an overhead installation on a technical evaluation motor (TEM).

Cook, M.↗

Stochastic stellar cluster initial mass functions: Models and impact on integrated cluster parameter determination

Stellar clusters are regularly used to study the evolution of their host galaxy. Except for a few nearby galaxies, these studies rely on the interpretation of integrated cluster properties, especially integrated photometry observed using multiple filters (i.e., the spectral energy distribution, SED). To allow interpretation of such observations, we present a large set of GALEV cluster models using the realistic approach of adopting stochastically sampled stellar initial mass functions. We provide models for a wide range of cluster masses (10{sup 3}-2 × 10{sup 5} M {sub ☉}), metallicities (–2.3 ≤ [Fe/H] ≤ +0.18 dex), foreground extinction, and 184 regularly used filters. We analyze various sets of stochastic cluster SEDs by fitting them with non-stochastic models, which is the procedure commonly used in this field. We identify caveats and quantify the fitting uncertainties associated with this standard procedure. We show that this can yield highly unreliable fitting results, especially for low-mass clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Contour advection with surgery: A technique for investigating finescale structure in tracer transport

We present a trajectory technique, contour advection with surgery (CAS), for tracing the evolution of material contours in a specified (including observed) evolving flow. CAS uses the algorithms developed by Dritschel for contour dynamics/surgery to trace the evolution of specified contours. The contours are represented by a series of particles, which are advected by a specified, gridded, wind distribution. The resolution of the contours is preserved by continually adjusting the number of particles, and finescale features are produced that are not present in the input data (and cannot easily be generated using standard trajectory techniques). The reliability, and dependence on the spatial and temporal resolution of the wind field, of the CAS procedure is examined by comparisons with high-resolution numerical data (from contour dynamics calculations and from a general circulation model), and with routine stratospheric analyses. These comparisons show that the large-scale motions dominate the deformation field and that CAS can accurately reproduce small scales from low-resolution wind fields. The CAS technique therefore enables examination of atmospheric tracer transport at previously unattainable resolution.

Waugh, Darryn W.↗

Efficient solution of unsteady transonic flows about airfoils

An implicit finite difference procedure was developed for the efficient solution of unsteady transonic flow fields. Sample computations illustrate applications of procedures to aerodynamic problems. Solutions are presented that illustrate three types of shock wave motion that can result from airfoil control surface oscillations. The significant effect of wind tunnel wall conditions on these shock wave motions is demonstrated. Solutions are also presented for a simple aeroelastic problem in which the flow field equations and the structural motion equations are integrated simultaneously in time. Both stable and unstable aeroelastic interactions are considered. The procedure is adapted to compute unsteady aerodynamic force coefficients by the indicial method.

Ballhaus, W. F.↗

MEAN AGE GRADIENT AND ASYMMETRY IN THE STAR FORMATION HISTORY OF THE SMALL MAGELLANIC CLOUD

We derive the star formation history (SFH) in four regions of the Small Magellanic Cloud (SMC) using the deepest VI color-magnitude diagrams (CMDs) ever obtained for this galaxy. The images were obtained with the Advanced Camera for Surveys on board the Hubble Space Telescope (HST) and are located at projected distances of 0.°5-2° from the SMC center, probing the main body and the wing of the galaxy. We derived the SFHs of the four fields using two independent procedures to fit synthetic CMDs to the data. We compare the SFHs derived here with our earlier results for the SMC bar to create a deep pencil-beam survey of the global history of the central SMC. We find in all the six fields observed with HST a slow star formation (SF) pace from 13 to 5-7 Gyr ago, followed by a ≈2-3 times higher activity. This is remarkable because dynamical models do not predict a strong influence of either the Large Magellanic Cloud (LMC) or the Milky Way at that time. The level of the intermediate-age SF rate enhancement systematically increases toward the center, resulting in a gradient in the mean age of the population, with the bar fields being systematically younger than the outer ones. SF over the most recent 500 Myr is strongly concentrated in the bar, the only exception being the area of the SMC wing. The strong current activity of the latter is likely driven by interaction with the LMC. At a given age, there is no significant difference in metallicity between the inner and outer fields, implying that metals are well mixed throughout the SMC. The age-metallicity relations we infer from our best-fitting models are monotonically increasing with time, with no evidence of dips. This may argue against the major merger scenario proposed by Tsujimoto and Bekki in 2009, although a minor merger cannot be ruled out.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures

Purpose: The unintended radiation dose to organs at risk (OAR) can be contributed from imaging guidance procedures as well as from leakage and scatter of therapeutic beams. This study compares the imaging dose with the unintended out-of-field therapeutic dose to patient sensitive organs. Methods: The Monte Carlo EGSnrc user codes, BEAMnrc and DOSXYZnrc, were used to simulate kV X-ray sources from imaging devices as well as the therapeutic IMRT/VMAT beams and to calculate doses to target and OARs on patient treatment planning CT images. The accuracy of the Monte Carlo simulations was benchmarked against measurements in phantoms. The dose-volume histogram was utilized in analyzing the patient organ doses. Results: The dose resulting from Standard Head kV-CBCT scans to bone and soft tissues ranges from 0.7 to 1.1 cGy and from 0.03 to 0.3 cGy, respectively. The dose resulting from Thorax scans on the chest to bone and soft tissues ranges from 1.1 to 1.8 cGy and from 0.3 to 0.6 cGy, respectively. The dose resulting from Pelvis scans on the abdomen to bone and soft tissues range from 3.2 to 4.2 cGy and from 1.2 to 2.2 cGy, respectively. The out-of-field doses to OAR are sensitive to the distance between the treated target and the OAR. For a typical Head-and-Neck IMRT/VMAT treatment the out-of-field doses to eyes are 1–3% of the target dose, or 2–6 cGy per fraction. Conclusion: The imaging doses to OAR are predictable based on the imaging protocols used when OARs are within the imaged volume and can be estimated and accounted for by using tabulated values. The unintended out-of-field doses are proportional to the target dose, strongly depend on the distance between the treated target and OAR, and are generally higher comparing to the imaging dose. This work was partially supported by Varian research grant VUMC40590.

60 APPLIED LIFE SCIENCES↗

Calibrating the simple biosphere model for Amazonian tropical forest using field and remote sensing data. I - Average calibration with field data

Using meteorological and hydrological measurements taken in and above the central-Amazon-basin tropical forest, calibration of the Sellers et al. (1986) simple biosphere (SiB) model are described. The SiB model is a one-dimensional soil-vegetation-atmosphere model designed for use within GCMs models, representing the vegetation cover by analogy with processes operating within a single representative plant. The experimental systems and the procedures used to obtain field data are described, together with the specification of the physiological parameterization required to provide an average description of data. It was found that some of the existing literature on stomatal behavior for tropical species is inconsistent with the observed behavior of the complete canopy in Amazonia, and that the rainfall interception store of the canopy is considerably smaller than originally specified in the SiB model.

Sellers, Piers J.↗

Numerical boundary condition procedures and multigrid methods; Proceedings of the Symposium, NASA Ames Research Center, Moffett Field, CA, October 19-22, 1981

Papers presented in this volume provide an overview of recent work on numerical boundary condition procedures and multigrid methods. The topics discussed include implicit boundary conditions for the solution of the parabolized Navier-Stokes equations for supersonic flows; far field boundary conditions for compressible flows; and influence of boundary approximations and conditions on finite-difference solutions. Papers are also presented on fully implicit shock tracking and on the stability of two-dimensional hyperbolic initial boundary value problems for explicit and implicit schemes.

Source record↗

A new look at Fresnel field computation using the Jacobi-Bessel series

Computational procedures that would be useful in finding the Fresnel field from a knowledge of the Jacobi-Bessel expansion of the far field are considered. The range of validity of the Fresnel approximation is carefully examined by comparing it with the exact closed form solution for the uniform circular aperture. Also investigated numerically, and in great detail, is the range of validity (over theta) of the Fresnel small angle (FSA) approximation. For moderate sized apertures as small as 10 wavelengths, it is found that the FSA approximation is very accurate to angles as wide as four or more sidelobes (as seen in the far zone). A very efficient computational method is shown to exist for the radiation integral in the form of a single series expansion that is analytically continuous and convergent for a wide range of observation points in three-dimensional space.

Galindo-Israel, V.↗

General Matrix Inversion Technique for the Calibration of Electric Field Sensor Arrays on Aircraft Platforms

A matrix calibration procedure has been developed that uniquely relates the electric fields measured at the aircraft with the external vector electric field and net aircraft charge. The calibration method can be generalized to any reasonable combination of electric field measurements and aircraft. A calibration matrix is determined for each aircraft that represents the individual instrument responses to the external electric field. The aircraft geometry and configuration of field mills (FMs) uniquely define the matrix. The matrix can then be inverted to determine the external electric field and net aircraft charge from the FM outputs. A distinct advantage of the method is that if one or more FMs need to be eliminated or deemphasized [e.g., due to a malfunction), it is a simple matter to reinvert the matrix without the malfunctioning FMs. To demonstrate the calibration technique, data are presented from several aircraft programs (ER-2, DC-8, Altus, and Citation).

Mach, D. M.↗

Refinement of Protocols for Measuring the Apparent Optical Properties of Seawater

Ocean color satellite missions, like the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) or the Moderate Resolution Imaging Spectroradiometer (MODIS) projects, are tasked with acquiring a global ocean color data set, validating and monitoring the accuracy and quality of the data, processing the radiometric data into geophysical units using a set of atmospheric and bio-optical algorithms, and distributing the final products to the scientific community. The long-standing requirement of the SeaWiFS Project, for example, is to produce spectral water-leaving radiances, LW(lambda), to within 5% absolute (lambda denotes wavelength) and chlorophyll a concentrations to within 35% (Hooker and Esaias 1993), and most ocean color sensors have the same or similar requirements. Although a diverse set of activities are required to ensure the accuracy requirements are met (Hooker and McClain 2000), the perspective here is with field observations. The accurate determination of upper ocean apparent optical properties (AOPs) is essential for the vicarious calibration of ocean color data and the validation of the derived data products, because the sea-truth measurements are used to evaluate the satellite observations (Hooker and McClain 2000). The uncertainties with in situ AOP measurements have various sources: a) the sampling procedures used in the field, including the environmental conditions encountered; b) the absolute characterization of the radiometers in the laboratory; c) the conversion of the light signals to geophysical units in a processing scheme, and d) the stability of the radiometers in the harsh environment they are subjected to during transport and use. Assuming ideal environmental conditions, so this aspect can be neglected, the SeaWiFS ground-truth uncertainty budget can only be satisfied if each uncertainty is on the order of 1-2%, or what is generally referred to as 1% radiometry. In recent years, progress has been made in estimating the magnitude of some of these uncertainties and in defining procedures for minimizing them. For the SeaWiFS Project, the first step was to convene a workshop to draft the SeaWiFS Ocean Optics Protocols (hereafter referred to as the Protocols). The Protocols initially adhered to the Joint Global Ocean Flux Study (JGOFS) sampling procedures (JGOFS 1991) and defined the standards for optical measurements to be used in SeaWiFS calibration and validation activities (Mueller and Austin 1992). Over time, the Protocols were revised (Mueller and Austin 1995), and then recurringly updated on essentially an annual basis (Mueller 2000, 2002, and 2003) as part of the Sensor Inter-comparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) project. 98

Hooker, Stanford B.↗

Prediction of the acoustic field in a three-dimensional rectangular duct using the boundary element method

A boundary element formulation, along with detailed solution procedure for determining the acoustic field inside a three-dimensional, rectangular duct is presented in this paper. The results of classical and boundary element solutions are compared for a typical rectangular duct by restricting the input frequency in such a way that only plane wave propagation is possible. The effect of changing the type and number of discrete boundary elements on the computed sound pressure levels inside the duct is also presented.

Pates, Carl S., III↗

A three-layer magnetic shielding for the MAIUS-1 mission on a sounding rocket

Bose-Einstein-Condensates (BECs) can be used as a very sensitive tool for experiments on fundamental questions in physics like testing the equivalence principle using matter wave interferometry. Since the sensitivity of these experiments in ground-based environments is limited by the available free fall time, the QUANTUS project started to perform BEC interferometry experiments in micro-gravity. After successful campaigns in the drop tower, the next step is a space-borne experiment. The MAIUS-mission will be an atom-optical experiment that will show the feasibility of experiments with ultra-cold quantum gases in microgravity in a sounding rocket. The experiment will create a BEC of 10{sup 5} {sup 87}Rb-atoms in less than 5 s and will demonstrate application of basic atom interferometer techniques over a flight time of 6 min. The hardware is specifically designed to match the requirements of a sounding rocket mission. Special attention is thereby spent on the appropriate magnetic shielding from varying magnetic fields during the rocket flight, since the experiment procedures are very sensitive to external magnetic fields. A three-layer magnetic shielding provides a high shielding effectiveness factor of at least 1000 for an undisturbed operation of the experiment. The design of this magnetic shielding, the magnetic properties, simulations, and tests of its suitability for a sounding rocket flight are presented in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

USING CORONAL CELLS TO INFER THE MAGNETIC FIELD STRUCTURE AND CHIRALITY OF FILAMENT CHANNELS

Coronal cells are visible at temperatures of {approx}1.2 MK in Fe XII coronal images obtained from the Solar Dynamics Observatory and Solar Terrestrial Relations Observatory spacecraft. We show that near a filament channel, the plumelike tails of these cells bend horizontally in opposite directions on the two sides of the channel like fibrils in the chromosphere. Because the cells are rooted in magnetic flux concentrations of majority polarity, these observations can be used with photospheric magnetograms to infer the direction of the horizontal field in filament channels and the chirality of the associated magnetic field. This method is similar to the procedure for inferring the direction of the magnetic field and the chirality of the fibril pattern in filament channels from H{alpha} observations. However, the coronal cell observations are easier to use and provide clear inferences of the horizontal field direction for heights up to {approx}50 Mm into the corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Electric Field Conjugation in the Presence of Model Uncertainty

The Wide-Field Infrared Survey Telescope (WFIRST) is a 2.4-meter-diameter space telescope NASA program. The payload will include a coronagraph instrument (CGI). The CGI designs under development use deformable mirrors (DM) to create a point spread function (PSF) with a dark region around the obscured star object. Electric field conjugation (EFC) is an iterative nonlinear optimization procedure that uses measurements of the electric field at the image to determine the DM displacements to modify the PSF to create the region of high contrast in the image. EFC requires a numerical model of the coronagraph to calculate the Jacobian of the system, which is used, along with regularization, to solve for the DM displacements for each iteration of the nonlinear optimization. Ideally, the coronagraph is aligned and calibrated, and the calibration data are used in the numerical model for calculating the Jacobian. However, calibration and alignment measurements always contain uncertainty resulting in calibration error. Therefore, the Jacobian calculated from the numerical model is not an exact representation of the physical coronagraph, and the resulting DM solution for an EFC iteration does not have the exact impact on the electric field of the coronagraph as predicted by the EFC. The result is slow convergence, and, as will be shown, drives the use of more restrictive regularization. Using Monte Carlo trials, we investigate the effect of calibration error on EFC convergence and regulatization. Comparison to results from the High Contrast Imaging Testbed Hybrid Lyot Coronagraph are also presented.

Marx, David↗

Implementing computer-based procedures: thinking outside the paper margins - 236

In the past year there has been increased interest from the nuclear industry in adopting the use of electronic work packages and computer-based procedures (CBPs) in the field. The goal is to incorporate the use of technology in order to meet the Nuclear Promise requirements of reducing costs, and improving efficiency and decreasing human error rates in plant operations. Researchers, together with the nuclear industry, have been investigating the benefits of an electronic work package system and specifically CBPs would have over current paper-based procedure practices. There are several classifications of CBPs ranging from a straight copy of the paper-based procedure in PDF format to a more intelligent dynamic CBP. A CBP system offers a vast variety of potential improvements, such as context driven job aids, integrated human performance tools (e.g., place-keeping and correct component verification), and dynamic step presentation. However, the implementation of a CBP system does not automatically improve the quality of procedures. Utilities should review, standardize format and update current procedure content before transitioning to a computerized process. Implementation of a CBP system can be a time to break out of traditional procedure writing processes and create new processes and procedures that take advantage of the capabilities a CBP system. This paper summarizes INL research findings related to challenges with implementing a CBP system and provides suggestions to take into consideration. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗