Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Ventilation Control of Volatile Organic Compounds in New U.S. Homes: Results of a Controlled Field Study in Nine Residential Units

In order to optimize strategies to remove airborne contaminants in residences, it is necessary to determine how contaminant concentrations respond to changes in the air exchange rate. The impact of air exchange rate on the indoor concentrations of 39 target volatile organic compounds (VOCs) was assessed by measuring air exchange rates and VOC concentrations at three ventilation settings in nine residences. Active sampling methods were used for VOC concentration measurements, and passive perfluorocarbon tracer gas emitters with active sampling were used to determine the overall air exchange rate corresponding to the VOC measurements at each ventilation setting. The concentration levels and emission rates of the target VOCs varied by as much as two orders of magnitude across sites. Aldehyde and terpene compounds were typically the chemical classes with highest concentrations, followed by alkanes, aromatics, and siloxanes. For each home, VOC concentrations tended to decrease as the air exchange rate was increased, however, measurement uncertainty was significant. The indoor concentration was inversely proportional to air exchange rate for most compounds. For a subset of compounds including formaldehyde, however, the indoor concentration exhibited a non-linear dependence on the timescale for air exchange

42 ENGINEERING↗

Integrated Precipitation and Hydrology Experiment (IPHEx)/Orographic Precipitation Processes Study Field Campaign Report

Three Microwave Radiometers (two 3-channel and one 2-channel) were deployed in the Southern Appalachian Mountains in western North Carolina as part of the Integrated Precipitation and Hydrology Experiment (IPHEx), which was the first National Aeronautics and Space Administration (NASA) Global Precipitation Mission (GPM) Ground Validation (GV) field campaign after the launch of the GPM Core Satellite (Barros et al. 2014). The radiometers were used along with other instrumentation to estimate the liquid water content of low-level clouds and fog. Specifically, data from the radiometers were collected to help, with other instrumentation, to characterize fog formation, evolution, and dissipation in the region (by monitoring the liquid water path in the column) and observe the effect of that fog on the precipitation regime. Data were collected at three locations in the Southern Appalachians, specifically western North Carolina: a valley in the inner mountain region, a valley in the open mountain pass region, and a ridge in the inner region. This project contributes to the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility mission by providing in situ observations designed to improve the understanding of clouds and precipitation processes in complex terrain. The end goal is to use this improved understanding of physical processes to improve remote-sensing algorithms and representations of orographic precipitation microphysics in climate and earth system models.

58 GEOSCIENCES↗

Costs to Automate Demand Response - Taxonomy and Results from Field Studies and Programs

During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems, and applies a standard naming convention and classification or taxonomy for system elements. Median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude great or less than the median. This wide range is a result of variations in system age, size of load reduction, sophistication, and type of equipment included in cost analysis. The costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total cost to install, operate, and maintain these systems. However, recent research suggests that they could be developed at costs similar to those of existing hot-summer DR automation systems. This report considers installation and configuration costs and does include the costs of owning and operating DR automation systems. Future analysis of the latter costs should include the costs to the building or facility manager costs as well as utility or third party program manager cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Field Study of Wall Furnace Venting and Coincident Exhaust Fan Usage in 16 Northern California Apartments

To inform efforts to improve combustion appliance testing in residential energy efficiency programs, we studied the frequency of coincident fan use and depressurization-induced downdrafting and spillage from atmospherically vented (i.e., natural draft) wall furnaces in airtight apartments. Indoor environmental conditions, heating appliance operation, use of exhaust fans, and cooking with stovetop or oven were monitored for approximately three weeks each in 16 apartment units in two buildings in Northern California. Apartments also were assessed using standard combustion appliance safety test methods and enhanced protocols. Monitoring occurred in February and March of 2016, with heating demand corresponding to 7.3 ± 0.5 heating degree-days at a 65ºF reference temperature. Most of the furnaces spilled combustion products when the apartments were depressurized in the “worst-case” challenge condition of all exhaust fans operating at their highest settings and all windows closed. Many also spilled under less challenging conditions (e.g., with kitchen exhaust fan on low and bathroom fan operating). On average, bathroom exhaust fans were operated 3.9% of monitored minutes (13.5% max), and cooking (burner or kitchen fan operation) occurred 4.6% of minutes (max 13.3%). Event lengths averaged 17 minutes (max 540) and 34 minutes (max 324), respectively. Their coincident operation averaged 0.34% of minutes (max 2.0%), with average event length of 13 minutes (max 92 minutes). This suggests that the operation of apartment units at or near the currently used worst-case challenge condition is quite rare. Wall furnace burners operated an average of 2.8% of minutes (max of 8.9%), with average burner cycle length of 14 minutes (max 162). Coincident bath fan use, cooking and wall furnace operation was very rare, occurring only a handful of times across all apartments. The highest rate was 0.075% of monitored minutes in one apartment, and the longest event length was 12 minutes. Exhaust fan operation in this study may have been more frequent than typical as participants were asked to use an exhaust fan whenever cooking or bathing. Consistent with the low levels of coincident operation, unambiguous spillage occurred in only 4 apartments and the longest event was 5 minutes. The frequency of partial spillage is unknown, owing to a lack of a clear signal from monitored parameters. Downdrafting during exhaust fan use occurred in all 13 of the apartments with relevant data, and 9 of these units had 10 or more events. Exhaust fans also sometimes led to weakened draft, even if downdrafting did not occur. Each unambiguous spillage event identified in the study was immediately preceded by downdrafting. The observed occurrence of downdrafting and spillage may have been impacted in those apartments with the most severe drafting problems (i.e., appliances spilled combustion pollutants under ‘natural’ test conditions), because occupants in these units were instructed to open windows whenever using the kitchen exhaust fan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Code Field Study

This document presents a methodology for assessing baseline energy efficiency in new single-family residential buildings and quantifying related savings potential. The approach was developed by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) Building Energy Codes Program with the objective of assisting states as they assess energy efficiency in residential buildings and implementation of their building energy codes, as well as to target areas for improvement through energy codes and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set to represent baseline construction practices across U.S. states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Montana Residential Energy Code Field Study

A research project in the state of Montana identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in May 2018; data collection began in June 2018 and continued through September 2018. Analysis of the data has led to a better understanding of the energy features present in homes and identified nearly $192,000 in potential annual savings to Montana homeowners that could result from increased compliance with the Montana Residential Energy Code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oregon Residential Energy Code Field Study

A research project in the state of Oregon identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in November 2019; data collection began in November 2019 and continued through February 2020. Analysis of the data has led to a better understanding of the energy features present in homes and identified over $600,000 in potential annual savings to Oregon homeowners that could result from increased compliance with the 2017 Oregon Residential Specialty Code (2017 ORSC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virginia Residential Energy Code Field Study: Baseline Report

A research project in the Commonwealth of Virginia identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in August 2017 and continued through May 2018. Analysis of the data has led to a better understanding of the energy features present in homes and indicates over $2.9 million in potential annual savings to Virginia homeowners that could result from increased code compliance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the drivers of Isoprene SOA: laboratory studies, field observations and modeling (Final Technical Report)

This report describes the research results and products stemming from the funding award DE-SC0018221. The main goals of this project were to develop a quantitative understanding of the factors driving secondary organic aerosol (SOA) formation from biogenic volatile organic compounds, namely isoprene and monoterpenes, using a combination of laboratory measurements, field data analysis, and modeling. Specifically, we aimed to: 1) develop an observationally constrained volatility distribution of trace gases produced from the oxidation of biogenic hydrocarbons that can explain the formation of SOA from in situ observations made during DOE ASR/ARM field campaigns such as HI-SCALE and BAECC 2) use new and existing (e.g. DOE ASR funded SOAFFEE experiments) laboratory chamber experiments to develop detailed parameterizations of isoprene-derived epxoy diol (IEPOX) reactive uptake, including product branching, product volatility, and solubility constants, as well as SOA formation generally from the formation of highly oxygenated organic molecules (HOM) formed from isoprene and monoterpene photo-oxidation that can be directly incorporated into models. 3) collaborate with PNNL modeling teams to incorporate new parameterizations into detailed box models, such as MOSAIC, and regional or Earth System models such as WRF.

54 ENVIRONMENTAL SCIENCES↗

SoRcer Test Utqiagvik Deployment for Ionograms (STUDI) Field Campaign Report

The U.S. Air Force Research Laboratory (AFRL) has developed a passive broadband radio frequency (RF) receiver, called a Sounder Receiver (SoRcer), as an ionospheric diagnostic instrument. These systems can produce ionospheric specifications to characterize the local ionosphere. The specifications from the SoRcers can then be used to inform data assimilation models; monitor diurnal, seasonal, or other cyclical changes; and detect irregularities or abnormalities in the ionosphere, such as traveling ionospheric disturbances (TIDs), sporadic E, and spread F.

54 ENVIRONMENTAL SCIENCES↗

Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump

Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗