Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Characterization of the Potential Hazards Associated with Potential RCRA Treatment Noncompliances

The purpose of this document is to provide a hazard evaluation of the noncompliances and whether any new actions are required to mitigate potential risk to the worker or the public. In short, we have reviewed the noncompliances and have concluded that the possibility of exothermic reactions leading to radioactive release is not credible, and in one case, inconceivable, stemming from the fact that the majority fraction of the waste is compatible with organic absorbents and neutralizers. It is not expected that the noncompliances would generate or produce uncontrolled flammable fumes, gases, extreme heat, pressure, fire, explosions, or violent reactions.

54 ENVIRONMENTAL SCIENCES↗

Invasive Plant Management Plan for the Oak Ridge Reservation

Invasive non-native plant species have become one of the greatest ecological threats across the country and around the world. Actively managing incursions of invasive plants is crucial to maintaining ecosystems, protecting natural resources, and ensuring proper function of facilities and their support infrastructures, power lines and other utility rights-of-way (ROWs), communications structures, roadways, and waterways. Invasive plants can threaten cultural resources, public and private properties, forests, wetlands, and other natural areas through increased risks of fire and storm damage, as well as decrease native plant diversity, particularly disrupting vital habitats of threatened and endangered species, both plant and animal. In 2000, the Federal Plant Protection Act came into effect. Under this Act, federal agencies are required to develop and coordinate an undesirable plants management program for control of invasive plants on federal lands under each agency’s respective jurisdiction. The agency must adequately fund the undesirable plants management program using an Integrated Pest Management Plan. Additionally, each agency is required to implement cooperative agreements with local and state agencies, as well as other federal agencies, to manage undesirable plants on federal lands under the agency’s jurisdiction. The US Department of Energy (DOE) takes its responsibility for addressing invasive and undesirable plant issues very seriously. Many DOE sites have programs to control invasive pest plant species. DOE has taken a proactive stance toward invasive plant control, and the Invasive Plant Management Plan— created to meet regulatory requirements of federal laws, executive orders, presidential memos, contracts, and agreements on DOE’s Oak Ridge Reservation (ORR)—has been in effect since 2004. This document represents the second revision of this plan.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of grassland fire dynamics on particulate emission factors

Understanding particulate emission factors in grassland fires is critical for improving air quality assessments and refining emissions inventories. This study explores the dynamic and heterogeneous nature of fire processes and their influence on particulate emissions. Traditional emission factor inventories often rely on static values, overlooking the spatially and temporally variable dynamics of fire behavior. Through field experiments conducted at Konza Prairie Biological Station measuring emissions with uncrewed aerial vehicles, and computational modeling using HIGRAD/FIRETEC, this research highlights the dependency of emission production on localized fire dynamics, including ignition patterns, fuel properties, and atmospheric conditions. The results demonstrate a need for fire dynamic considerations to accurately capture emissions variability.

09 BIOMASS FUELS↗

High energy arcing fault fires in switchgear equipment : a literature review.

In power generating plants, switchgear provide a means to isolate and de-energize specific electrical components and buses in order to clear downstream faults, perform routine maintenance, and replace necessary electrical equipment. These protective devices may be categorized by the insulating medium, such as air or oil, and are typically specified by voltage classes, i.e. low, medium, and high voltage. Given their high energy content, catastrophic failure of switchgear by means of a high energy arcing fault (HEAF) may occur. An incident such as this may lead to an explosion and fire within the switchgear, directly impact adjacent components, and possibly render dependent electrical equipment inoperable. Historically, HEAF events have been poorly documented and discussed in little detail. Recent incidents involving switchgear components at nuclear power plants, however, were scrupulously investigated. The phenomena itself is only understood on a very elementary level from preliminary experiments and theories; though many have argued that these early experiments were inaccurate due to primitive instrumentation or poorly justified methodologies and thus require re-evaluation. Within the past two decades, however, there has been a resurgence of research that analyzes previous work and modern technology. Developing a greater understanding of the HEAF phenomena, in particular the affects on switchgear equipment and other associated switching components, would allow power generating industries to minimize and possibly prevent future occurrences, thereby reducing costs associated with repair and downtime. This report presents the findings of a literature review focused on arc fault studies for electrical switching equipment. The specific objective of this review was to assess the availability of the types of information needed to support development of improved treatment methods in fire Probabilistic Risk Assessment (PRA) for nuclear power plant applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cyber Friendly Fire

Cyber friendly fire (FF) is a new concept that has been brought to the attention of Department of Defense (DoD) stakeholders through two workshops that were planned and conducted by the Air Force Research Laboratory (AFRL) and research conducted for AFRL by the Pacific Northwest National Laboratory. With this previous work in mind, we offer a definition of cyber FF as intentional offensive or defensive cyber/electronic actions intended to protect cyber systems against enemy forces or to attack enemy cyber systems, which unintentionally harms the mission effectiveness of friendly or neutral forces. Just as with combat friendly fire, a fundamental need in avoiding cyber FF is to maintain situation awareness (SA). We suggest that cyber SA concerns knowledge of a system's topology (connectedness and relationships of the nodes in a system), and critical knowledge elements such as the characteristics and vulnerabilities of the components that comprise the system (and that populate the nodes), the nature of the activities or work performed, and the available defensive (and offensive) countermeasures that may be applied to thwart network attacks. A training implication is to raise awareness and understanding of these critical knowledge units; an approach to decision aids and/or visualizations is to focus on supporting these critical knowledge units. To study cyber FF, we developed an unclassified security test range comprising a combination of virtual and physical devices that present a closed network for testing, simulation, and evaluation. This network offers services found on a production network without the associated costs of a real production network. Containing enough detail to appear realistic, this virtual and physical environment can be customized to represent different configurations. For our purposes, the test range was configured to appear as an Internet-connected Managed Service Provider (MSP) offering specialized web applications to the general public. The network is essentially divided into a production component that hosts the web and network services, and a user component that hosts thirty employee workstations and other end devices. The organization's network is separated from the Internet by a Cisco ASA network security device that both firewalls and detects intrusions. Business sensitive information is stored in various servers. This includes data comprising thousands of internal documents, such as finance and technical designs, email messages for the organization's employees including the CEO, CFO, and CIO, the organization's source code, and Personally Identifiable client data. Release of any of this information to unauthorized parties would have a significant, detrimental impact on the organization's reputation, which would harm earnings. The valuable information stored in these servers pose obvious points of interest for an adversary. We constructed several scenarios around this environment to support studies in cyber SA and cyber FF that may be run in the test range. We describe mitigation strategies to combat cyber FF including both training concepts and suggestions for decision aids and visualization approaches. Finally, we discuss possible future research directions.

99 GENERAL AND MISCELLANEOUS↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Security Informatics Research Challenges for Mitigating Cyber Friendly Fire

This paper addresses cognitive implications and research needs surrounding the problem of cyber friendly re (FF). We dene cyber FF as intentional o*ensive or defensive cyber/electronic actions intended to protect cyber systems against enemy forces or to attack enemy cyber systems, which unintentionally harms the mission e*ectiveness of friendly or neutral forces. We describe examples of cyber FF and discuss how it ts within a general conceptual framework for cyber security failures. Because it involves human failure, cyber FF may be considered to belong to a sub-class of cyber security failures characterized as unintentional insider threats. Cyber FF is closely related to combat friendly re in that maintaining situation awareness (SA) is paramount to avoiding unintended consequences. Cyber SA concerns knowledge of a system's topology (connectedness and relationships of the nodes in a system), and critical knowledge elements such as the characteristics and vulnerabilities of the components that comprise the system and its nodes, the nature of the activities or work performed, and the available defensive and o*ensive countermeasures that may be applied to thwart network attacks. We describe a test bed designed to support empirical research on factors a*ecting cyber FF. Finally, we discuss mitigation strategies to combat cyber FF, including both training concepts and suggestions for decision aids and visualization approaches.

cyber friendly fire↗

Flue Gas Desulfurization Wastewater Composition and Implications for Regulatory and Treatment Train Design

The U.S. Environmental Protection Agency is currently revising its regulations on trace element discharges from flue gas desulfurization (FGD) wastewater.<br>In this work, we expand a predictive model of trace element behavior at coal-fired power plants (CFPPs) to estimate the trace element concentration of FGD wastewater at the plant level. We demonstrate that variation in trace element concentrations in FGD wastewater can span several orders of magnitude and is a function of both coal rank and installed air pollution control devices. This conclusion suggests that the benefits and costs of FGD wastewater treatment for the median plant will poorly describe the actual benefits and costs over the full range of existing CFPPs.

Mauter, Meagan↗

Risk and resilience in an uncertain world

We report that because the future is uncertain and to some extent unknowable, it is imperative that ecologists become involved in the discussion and planning of future infrastructure and protection from the effects of altered disturbance regimes. Research can test and demonstrate the benefits of protecting or proactively managing important features and places, and processes that enhance provisioning of ecosystem services such as flood control and fire mitigation. In conclusion, it is time to demonstrate how ecological science, when applied to human–environmental systems, can reduce risks and enhance resilience in a complex, changing world.

54 ENVIRONMENTAL SCIENCES↗

Effects of Part-to-Part Flow Variations on Overall Effectiveness and Life of Rotating Turbine Blades

Abstract As firing temperatures in gas turbine engines continue to increase to achieve high efficiencies, components in the main gas path must be protected with cooling flows to ensure lifing targets are met. Manufacturing variations, however, influence the performance and life characteristics of components with the same nominal design. This study presents blade flow and overall cooling effectiveness measurements for nine true-scale, aero engine turbine blades with realistic manufacturing variations. Flow measurements were made through each blade at a fixed pressure ratio to determine flow variability between holes and between blades. Infrared thermography was used to capture spatially-resolved temperature measurements reported as overall effectiveness on the same nine blades under high-speed rotating conditions at the Steady Thermal Aero Research Turbine Laboratory. Thermal performance was correlated with blade flow performance indicating substantial blade-to-blade variations resulting from manufacturing differences. Measurements also indicated wide variations in cooling jet trajectories as well as overall cooling effectiveness. Finally, the observed blade-to-blade variations in effectiveness were scaled to engine conditions with lifing estimates showing some blades would be expected to last only half as long as others due to manufacturing variability.

Engineering↗

A Novel Low-Temperature Fiffusion Aluminide Coating for Ultrasupercritical Coal-Fried Boiler Applications

An ultrasupercritical (USC) boiler with higher steam temperature and pressure is expected to increase the efficiency of the coal-fired power plant and also decrease emissions of air pollutants. Ferritic/martensitic alloys have been developed with good creep strength for the key components in coal-fired USC plants. However, they typically suffer excessive steam-side oxidation, which contributes to one of main degradation mechanisms along with the fire-side corrosion in coal-fired boilers. As the steam temperature further increases in USC boilers, oxidation of the tube internals becomes an increasing concern, and protective coatings such as aluminide-based diffusion coatings need to be considered. However, conventional aluminizing processes via pack cementation or chemical vapor deposition are typically carried out at elevated temperatures (1000-1150 C). Thermochemical treatment of ferritic/martensitic alloys at such high temperatures could severely degrade their mechanical properties, particularly the alloy's creep resistance. The research focus of this project was to develop an aluminide coating with good oxidation resistance at temperatures {le} 700 C so that the coating processing would not detrimentally alter the creep performance of the ferritic/martensitic alloys. Nevertheless, when the aluminizing temperature is lowered, brittle Al-rich intermetallic phases, such as Fe{sub 2}Al{sub 5} and FeAl{sub 3}, tend to form in the coating, which may reduce the resistance to fatigue cracking. Al-containing binary masteralloys were selected based on thermodynamic calculations to reduce the Al activity in the pack cementation process and thus to prevent the formation of brittle Al-rich intermetallic phases. Thermodynamic computations were carried out using commercial software HSC 5.0 for a series of packs containing various Cr-Al binary masteralloys. The calculation results indicate that the equilibrium partial pressures of Al halides at 700 C were a function of Al content in the Cr-Al alloys. Cr-25Al and Cr-15Al were chosen as the masteralloys in the pack cementation process. In contrast to pure Al masteralloy which led to the formation of Fe{sub 2}Al{sub 5} coatings at 650 C, a coating consisting of a thin Fe{sub 2}Al{sub 5} outer layer and an FeAl inner layer was formed at 700 C with the Cr-25Al masteralloy. By switching to the Cr-15Al masteralloy, thin FeAl coatings ({approx}12 {micro}m) containing < 50 at.% Al were achieved at 700 C. The effect of the amount of masteralloys on coating growth was also studied by employing packs containing 2NH{sub 4}Cl-x(Cr-15Al)-(98-x)Al{sub 2}O{sub 3}, where x = 10, 20, 30, 40, 50, 60, and 70 wt.%. It was noticed that when the Cr-15Al masteralloy was increased from 10 to 40 wt.% in the pack, both coating thickness and surface Al content increased, suggesting that gas phase kinetics played an important role in Al deposition. However, with further increase of the masteralloy, solid state diffusion became the rate-limiting factor. The long-term oxidation performance of the aluminide coatings synthesized at 700 C with Cr-25Al and Cr-15Al masteralloys was evaluated in the water vapor environment at 650-700 C. The low-temperature pack coatings demonstrated excellent oxidation resistance at 650 C in humid air after {approx}1.2 yr testing. Longer lifetimes can be expected for these thin coatings due to minimal interdiffusion at this testing temperature. Exposure at 700 C was conducted to accelerate coating failure via increased interdiffusion of Al with the substrate alloy. The coatings also exhibited good oxidation protection up to 6,000-8,000 h at 700 C, with longer testing needed for coating failure to occur. Furthermore, the oxidation results indicate that in addition to the Al reservoir (as determined by the Al content and coating thickness), the initial coating surface quality had a significant impact on the oxidation behavior. In addition, the effect of various pack aluminide coatings on the creep resistance of coated T91 was investigated. Three representative types of coatings with different thicknesses, Al concentrations and phase constituents were included in the creep test. The creep experiments were performed at 650 C in air at uniaxial stress levels of 100-120 MPa. The thick aluminide coating made at 1050 C showed a considerable reduction ({approx} 42%) in the creep rupture life of the coated alloy, due to the decrease of the load-bearing section. In contrast, the low-temperature thin coatings developed in this project did not significantly reduce the creep resistance of the coated T91 alloy, particularly the thin FeAl coating synthesized at 700 C using the Cr-15Al masteralloy.

36 MATERIALS SCIENCE↗

Ultra-High Temperature Thermal Barrier Coating Development and Validation

The most effective method to improve industrial gas turbine power is to increase firing temperature. To maintain component durability at these higher temperatures, thermal barrier coatings (TBC’s) are playing an increasing role in protecting turbine hardware. TBC’s have been successfully used on Solar Turbines’ combustor liners and turbine airfoils, but there is a need for TBC’s that can operate at higher temperatures. Based on recent, favorable rig testing experience, Solar recognized that yttrium aluminum garnet (YAG) TBC’s made by the Solution Precursor Plasma Spray Process (SPPS) has great potential for higher turbine temperatures. This testing verified the thermal cycle durability of the SPPS YAG TBC’s, as well as demonstrated that the temperature drop through the SPPS YAG TBC was twice that measured across a companion APS YSZ TBC. The SPPS YAG TBC with the potential for a 200°C improvement in temperature capability represents a materials breakthrough. The SPPS process also produces a number of unique microstructural features that confer superior properties. SPPC TBC’s have ultra-fine splats that increase toughness and erosion resistance, and the process can be tailored to produce through-thickness cracks for strain-tolerance and control porosity for lower thermal conductivity and increase coating abradability. This proposal would include further development of SPPS YAG density-graded coatings, optimization of the application process, and validation of higher temperature capability and durability through rig and engine testing of coated combustion liners and turbine outer air seals. The technology would be advanced from a TRL 3 to a proposed TRL 6 by overcoming processing concerns on efficiency, application distance and optimization of a graded coating without impacting coating durability by demonstrating the coating performance on components in rig and development gas turbine engine testing.

36 MATERIALS SCIENCE↗

Battery management systems with thermally integrated fire suppression

A thermal management system is integral to a battery pack and/or individual cells. It relies on passive liquid-vapor phase change heat removal to provide enhanced thermal protection via rapid expulsion of inert high pressure refrigerant during abnormal abuse events and can be integrated with a cooling system that operates during normal operation. When a thermal runaway event occurs and sensed by either active or passive sensors, the high pressure refrigerant is preferentially ejected through strategically placed passages within the pack to rapidly quench the battery.

25 ENERGY STORAGE↗

Analysis and Experiment of Management Sciences Inc.'s Arc Fault Protection Connectors

The photovoltaics industry is in dire need of a cheap, robust, reliable arc fault detector that is sensitive enough to detect arc faults before they can develop into a fire while robust enough to noise to limit unwanted tripping. Management Sciences has developed an arc fault detector that is housed in a standard PV connector, which will disconnect the PV array when it detects the surge current from an arc fault. Sandia National Labs, an industry leader in the detection, characterization, and mitigation of arc faults in PV arrays, will work with Management Sciences to characterize, demonstrate, and develop their arc fault detection/connector technology.

14 SOLAR ENERGY↗

Field Evaluation of Novel Approach for Obtaining Metal Emission Data (Subtask 4.24)

Over the past two decades, emissions of mercury, nonmercury metals, and acid gases from energy generation and chemical production have increasingly become an environmental concern. On February 16, 2012, the U.S. Environmental Protection Agency (EPA) promulgated the Mercury and Air Toxics Standards (MATS) to reduce mercury, nonmercury metals, and HCl emissions from coal-fired power plants. The current reference methods for trace metals and halogens are wet-chemistry methods, EPA Method (M) 29 and M26A, respectively. As a possible alternative to EPA M29 and M26A, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (ME-ST) method to be used to sample for trace elements and/or halogens. Testing was conducted at three different power plants, and the results show that for halogens, the ME-ST halogen (ME-ST-H) method did not show any significant bias compared to EPA M26A and appears to be a potential candidate to serve as an alternative to the reference method. For metals, the ME-ST metals (ME-ST-M) method offers a lower detection limit compared to EPA M29 and generally produced comparable data for Sb, As, Be, Cd, Co, Hg, and Se. Both the ME-ST-M and M29 had problems associated with high blanks for Ni, Pb, Cr, and Mn. Although this problem has been greatly reduced through improved trap design and material selection, additional research is still needed to explore possible longer sampling durations and/or selection of lower background materials before the ME-ST-M can be considered as a potential alternative method for all the trace metals listed in MATS.

20 FOSSIL-FUELED POWER PLANTS↗

Uinta Basin CarbonSAFE II: Storage Complex Feasibility (Final Report)

The primary objective of this CarbonSAFE Phase II project was to establish the technical and commercial feasibility of a commercial-scale CO 2 geological storage complex for Deseret Power Electric Cooperative Bonanza Power Plant and other CO 2 sources in the northeast Uinta Basin, Utah, with the goal to securely store at least 50 million metric tons of captured CO 2 and accelerate CO 2 capture, utilization, and storage (CCUS) deployment. The project team established high-potential technical and commercial feasibility for a storage site within the east Uinta Basin (Utah), in the Cretaceous sandstones (Frontier, Dakota, and Buckhorn), Entrada Sandstone, Nugget Sandstone, and/or Weber Sandstone southwest of the Bonanza coal-fired power plant. This project collected and analyzed state-of-the-art data to characterize the storage complex consistent with Environmental Protection Agency (EPA) permitting standards. The team conducted extensive analog studies, outcrop mapping, and data sampling, which largely contributed to understanding the subsurface lithology and facies. Existing data were obtained and assessed from Utah Division of Oil, Gas, and Mining (DOGM), Utah Geological Survey (UGS), Colorado Geological Survey (CGS), U.S. Geological Survey (USGS), and EPA. These data were analyzed using state-of-the-art CCUS technologies for Societal Considerations, Site Characterization, Modeling and Simulations, Risk Assessment, Management and Monitoring, potential Underground Injection Control (UIC) Class VI Well Permitting, and Technical/Economic Feasibility. Through these high-resolution data collection and feasibility studies, this project was expected to provide a reference for initiating Underground Injection Control (UIC) and other commercial-scale geological storage permitting processes in the Western United States, ultimately contributing to the nation's decarbonization goals through low-risk, cost-effective commercial-scale carbon capture, utilization, and storage (CCUS) projects.

42 ENGINEERING↗

RHIC polarized proton-proton operation at 100 GeV in Run 15

The first part of RHIC Run 15 consisted of ten weeks of polarized proton on proton collisions at a beam energy of 100 GeV at two interaction points. In this paper we discuss several of the upgrades to the collider complex that allowed for improved performance. The largest effort consisted in commissioning of the electron lenses, one in each ring, which are designed to compensate one of the two beam-beam interactions experienced by the proton bunches. The e-lenses raise the per bunch intensity at which luminosity becomes beam-beam limited. A new lattice was designed to create the phase advances necessary for a beam-beam compensation with the e-lens, which also has an improved off-momentum dynamic aperture relative to previous runs. In order to take advantage of the new, higher intensity limit without suffering intensity driven emittance deterioration, other features were commissioned including a continuous transverse bunch-by-bunch damper in RHIC and a double harmonic RF cature scheme in the Booster. Other high intensity protections include improvements to the abort system and the installation of masks to intercept beam lost due to abort kicker pre-fires.

43 PARTICLE ACCELERATORS↗

Thermal Stress in HFEF Hot Cell Windows Due to an In-Cell Metal Fire

This work investigates an accident during the pyrochemical extraction of Uranium and Plutonium from PWR spent fuel in an argon atmosphere hot cell. In the accident, the heavy metals (U and Pu) being extracted are accidentally exposed to air from a leaky instrument penetration which goes through the cell walls. The extracted pin size pieces of U and Pu metal readily burn when exposed to air. Technicians perform the electrochemical extraction using manipulators through a 4 foot thick hot cell concrete wall which protects them from the radioactivity of the spent fuel. Four foot thick windows placed in the wall allow the technicians to visually control the manipulators. These windows would be exposed to the heat of the metal fire. As a result, this analysis determines if the thermal stress caused by the fire would crack the windows and if the heat would degrade the window seals allowing radioactivity to escape from the cell.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗