Search NASA⌕ Search

SEARCH · Search NASA

Results for “GRIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

In-Situ Measurements of Fabric Thickness Evolution During Draping

The paper presents results of experimental program aimed at measuring fabric thickening while draping. The thickness evolution is important factor in resin infusion manufacturing where the resultant composite thickness is not controlled. The measurements are conducted by means of laser distance sensors adapted to the picture frame testing. Several carbon fabrics of very different architectures have been tested. Additionally, the pretension of the carbon fabric due to the gripping has been estimated by means of digital image correlation technique and an attempt to discuss the results obtained on different set-ups is made.

36 MATERIALS SCIENCE↗

In situ nanomechanical testing in focused ion beam and scanning electron microscopes

The recent interest in size-dependent deformation of micro- and nanoscale materials has paralleled both technological miniaturization and advancements in imaging and small-scale mechanical testing methods. Here we describe a quantitative in situ nanomechanical testing approach adapted to a dual-beam focused ion beam and scanning electron microscope. A transducer based on a three-plate capacitor system is used for high-fidelity force and displacement measurements. Specimen manipulation, transfer, and alignment are performed using a manipulator, independently controlled positioners, and the focused ion beam. Gripping of specimens is achieved using electron-beam assisted Pt-organic deposition. Local strain measurements are obtained using digital image correlation of electron images taken during testing. Examples showing results for tensile testing of single-crystalline metallic nanowires and compression of nanoporous Au pillars will be presented in the context of size effects on mechanical behavior and highlight some of the challenges of conducting nanomechanical testing in vacuum environments.

36 MATERIALS SCIENCE↗

Tensile testing of materials at high temperatures above 1700 °C with in situ synchrotron X-ray micro-tomography

A compact ultrahigh temperature tensile testing instrument has been designed and fabricated for in situ x-ray micro-tomography using synchrotron radiation at the Advanced Light Source, Lawrence Berkeley National Laboratory. It allows for real time x-ray micro-tomographic imaging of test materials under mechanical load at temperatures up to 2300 °C in controlled environments (vacuum or controlled gas flow). Sample heating is by six infrared halogen lamps with ellipsoidal reflectors arranged in a confocal configuration, which generates an approximately spherical zone of high heat flux approximately 5 mm in diameter. Samples are held between grips connected to a motorized stage that loads the samples in tension or compression with forces up to 2.2 kN. The heating chamber and loading system are water-cooled for thermal stability. The entire instrument is mounted on a rotation stage that allows stepwise recording of radiographs over an angular range of 180°. A thin circumferential (360°) aluminum window in the wall of the heating chamber allows the x-rays to pass through the chamber and the sample over the full angular range. The performance of the instrument has been demonstrated by characterizing the evolution of 3D damage mechanisms in ceramic composite materials under tensile loading at 1750 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cryogenic continuously rotating half-wave plate mechanism for the POLARBEAR-2b cosmic microwave background receiver

In this report we present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background receiver, the second installment of the Simons Array. PB-2b will observe at 5200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 GHz and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to ≈50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing and a low-torque synchronous electromagnetic motor, which together dissipate < 2 W. During cooldown, a grip-and-release mechanism centers the rotor to < 0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 μrad/Hz. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.

47 OTHER INSTRUMENTATION↗

The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes

We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (Ø0.42 m) and large (Ø6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ~50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism’s vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 μrad √ $\overline{s}$. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

47 OTHER INSTRUMENTATION↗

Flexible magnetic composites for light-controlled actuation and interfaces

The interaction between light and matter has been long explored, leading to insights based on the modulation and control of electrons and/or photons within a material. An opportunity exists in optomechanics, where the conversion of radiation into material strain and actuation is currently induced at the molecular level in liquid crystal systems, or at the microelectromechanical systems (MEMS) device scale, producing limited potential strain energy (or force) in light-driven systems. We present flexible material composites that, when illuminated, are capable of macroscale motion, through the interplay of optically absorptive elements and low Curie temperature magnetic materials. These composites can be formed into films, sponges, monoliths, and hydrogels, and can be actuated with light at desired locations. Finally, light-actuated elastomeric composites for gripping and releasing, heliotactic motion, light-driven propulsion, and rotation are demonstrated as examples of the versatility of this approach.

42 ENGINEERING↗

Mechanism of tRNA-mediated +1 ribosomal frameshifting

Accurate translation of the genetic code is critical to ensure expression of proteins with correct amino acid sequences. Certain tRNAs can cause a shift out of frame (i.e., frameshifting) due to imbalances in tRNA concentrations, lack of tRNA modifications or insertions or deletions in tRNAs (called frameshift suppressors). Here, we determined the structural basis for how frameshift-suppressor tRNA SufA6 (a derivative of tRNA Pro ) reprograms the mRNA frame to translate a 4-nt codon when bound to the bacterial ribosome. After decoding at the aminoacyl (A) site, the crystal structure of the anticodon stem-loop of tRNA SufA6 bound in the peptidyl (P) site reveals ASL conformational changes that allow for recoding into the +1 mRNA frame. Furthermore, a crystal structure of full-length tRNA SufA6 programmed in the P site shows extensive conformational rearrangements of the 30S head and body domains similar to what is observed in a translocation intermediate state containing elongation factor G (EF-G). The 30S movement positions tRNA SufA6 toward the 30S exit (E) site disrupting key 16S rRNA–mRNA interactions that typically define the mRNA frame. In summary, this tRNA-induced 30S domain change in the absence of EF-G causes the ribosome to lose its grip on the mRNA and uncouples the canonical forward movement of the tRNAs during elongation.

59 BASIC BIOLOGICAL SCIENCES↗

Single-molecule investigations of single-chain cellulose biosynthesis

Cellulose biosynthesis in sessile bacterial colonies originates in the membrane-integrated bacterial cellulose synthase (Bcs) AB complex. We utilize optical tweezers to measure single-strand cellulose biosynthesis by BcsAB from Rhodobacter sphaeroides . Synthesis depends on uridine diphosphate glucose, Mg 2+ , and cyclic diguanosine monophosphate, with the last displaying a retention time of ∼80 min. Below a stall force of 12.7 pN, biosynthesis is relatively insensitive to force and proceeds at a rate of one glucose addition every 2.5 s at room temperature, increasing to two additions per second at 37°. At low forces, conformational hopping is observed. Single-strand cellulose stretching unveiled a persistence length of 6.2 nm, an axial stiffness of 40.7 pN, and an ability for complexes to maintain a tight grip, with forces nearing 100 pN. Stretching experiments exhibited hysteresis, suggesting that cellulose microstructure underpinning robust biofilms begins to form during synthesis. Cellohexaose spontaneously binds to nascent single cellulose strands, impacting polymer mechanical properties and increasing BcsAB activity.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Basis of Focal Adhesion Localization of LIM-only Adaptor PINCH by Integrin-linked Kinase

The LIM-only adaptor PINCH (the particularly interesting cysteine- and histidine-rich protein) plays a pivotal role in the assembly of focal adhesions (FAs), supramolecular complexes that transmit mechanical and biochemical information between extracellular matrix and actin cytoskeleton, regulating diverse cell adhesive processes such as cell migration, cell spreading, and survival. A key step for the PINCH function is its localization to FAs, which depends critically on the tight binding of PINCH to integrin-linked kinase (ILK). Here we report the solution NMR structure of the core ILK {center_dot} PINCH complex (28 kDa, K{sub D} {approx} 68 nm) involving the N-terminal ankyrin repeat domain (ARD) of ILK and the first LIM domain (LIM1) of PINCH. We show that the ILK ARD exhibits five sequentially stacked ankyrin repeat units, which provide a large concave surface to grip the two contiguous zinc fingers of the PINCH LIM1. The highly electrostatic interface is evolutionally conserved but differs drastically from those of known ARD and LIM bound to other types of protein domains. Consistently mutation of a hot spot in LIM1, which is not conserved in other LIM domains, disrupted the PINCH binding to ILK and abolished the PINCH targeting to FAs. These data provide atomic insight into a novel modular recognition and demonstrate how PINCH is specifically recruited by ILK to mediate the FA assembly and cell-extracellular matrix communication.

59 BASIC BIOLOGICAL SCIENCES↗

Ergonomics - Using Ergonomics to Enhance Safe Production at a Surface Coal Mine - A Case Study with Powder Crews

Job tasks that involve exposure to work-related musculoskeletal disorder (WMSD) risk factors may impact both the risk of injury and production downtime. Common WMSD risks factors associated with mining tasks include forceful exertions, awkward postures, repetitive motion, jolting and jarring, forceful gripping, contact stress, and whole body and segmental vibration. Mining environments that expose workers to temperature/humidity extremes, windy conditions, and slippery and uneven walking surfaces also contribute to injury risk. National Institute for Occupational Safety and Health (NIOSH) researchers worked with powder crew members from the Bridger Coal Company to identify and rank routine work tasks based on perceived exposure to WMSD risk factors. This article presents the process followed to identify tasks that workers believed involved the greatest exposure to risk factors and discusses risk reduction strategies. Specifically, the proposed prill truck design changes addressed cab ingress/egress, loading blast holes, and access to the upper deck of the prill truck.

01 COAL, LIGNITE, AND PEAT↗

PROSPECT OF STUDYING HARD X- AND GAMMA-RAYS FROM TYPE Ia SUPERNOVAE

We perform multi-dimensional, time-dependent radiation transfer simulations for hard X-ray and {gamma}-ray emissions, following radioactive decays of {sup 56}Ni and {sup 56}Co, for two-dimensional delayed-detonation models of Type Ia supernovae (SNe Ia). The synthetic spectra and light curves are compared with the sensitivities of current and future observatories for an exposure time of 10{sup 6} s. The non-detection of the {gamma}-ray signal from SN 2011fe at 6.4 Mpc by SPI on board INTEGRAL places an upper limit on the mass of {sup 56}Ni of {approx}< 1.0 M {sub Sun }, independently from observations in any other wavelengths. Signals from the newly formed radioactive species have not yet been convincingly measured from any SN Ia, but future X-ray and {gamma}-ray missions are expected to deepen the observable horizon to provide high energy emission data for a significant SN Ia sample. We predict that the hard X-ray detectors on board NuStar (launched in 2012) or ASTRO-H (scheduled for launch in 2014) will reach to SNe Ia at {approx}15 Mpc, i.e., one SN every few years. Furthermore, according to the present results, the soft {gamma}-ray detector on board ASTRO-H will be able to detect the 158 keV line emission up to {approx}25 Mpc, i.e., a few SNe Ia per year. Proposed next-generation {gamma}-ray missions, e.g., GRIPS, could reach to SNe Ia at {approx}20-35 Mpc by MeV observations. Those would provide new diagnostics and strong constraints on explosion models, detecting rather directly the main energy source of supernova light.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

A novel tensile device for in situ scanning electron microscope mechanical testing

To facilitate the study of deformation mechanisms and mechanical properties of bulk materials with feature size of centimeter level, a novel tensile device compatible with scanning electron microscope (SEM) was designed and built. Integrating the servo motor and three-stage reducer, the device could realize quasistatic loading mode with a loading speed of 10 nm/s. The device also presents broad compatibility with various types of SEMs due to its miniaturized dimensions and larger volume–output load ratio compared with existing and commercial tensile instruments. A small lead precise ball screw with left- and right-hand thread was adopted to keep the center of the specimen remain stationary without moving during the tensile testing. A novel gripping method was carefully taken into account to guarantee the alignment issues. The closed-loop control mode of the tensile process was developed. The displacement resolution of 40 nm was tested to verify the driving performance of the device. Furthermore, correction method on testing displacement was investigated based on the calibration experiments of the load sensor and displacement sensor, and the comparison tests based on stress–strain curve were carried out between the self-made device and the commercial tensile instrument (Instron 3345) to verify the feasibility and universality of the correction method.

36 MATERIALS SCIENCE↗

TU-AB-201-03: A Robot for the Automated Delivery of An Electromagnetic Tracking Sensor for the Localization of Brachytherapy Catheters

Purpose: To present a programmable robotic system for the accurate and fast deployment of an electromagnetic (EM) sensor for brachytherapy catheter localization. Methods: A robotic system for deployment of an EM sensor was designed and built. The system was programmed to increment the sensor position at specified time and space intervals. Sensor delivery accuracy was measured in a phantom using the localization of the EM sensor and tested in different environmental conditions. Accuracy was tested by measuring the distance between the physical locations reached by the sensor (measured by the EM tracker) and the intended programmed locations. Results: The system consisted of a stepper motor connected to drive wheels (that grip the cable to move the sensor) and a series of guides to connect to a brachytherapy transfer tube, all controlled by a programmable Arduino microprocessor. The total cost for parts was <$300. The positional accuracy of the sensor location was within 1 mm of the expected position provided by the motorized guide system. Acquisition speed to localize a brachytherapy catheter with 20 cm of active length was 10 seconds. The current design showed some cable slip and warping depending on environment temperature. Conclusion: The use of EM tracking for the localization of brachytherapy catheters has been previously demonstrated. Efficient data acquisition and artifact reduction requires fast and accurate deployment of an EM sensor in consistent, repeatable patterns, which cannot practically be achieved manually. The design of an inexpensive, programmable robot allowing for the precise deployment of stepping patterns was presented, and a prototype was built. Further engineering is necessary to ensure that the device provides efficient independent localization of brachytherapy catheters. This research was funded by the Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Ripples in reality

In a deep and dark corner of space, a cataclysm loomed. Two cosmic nemeses circled one another, locked in a macabre dance of death. Unfolding over millennia, the deadly waltz began leisurely enough. But with the dance came radiation and the energy loss that it implies. Orbit after orbit, the distance between the two protagonists shrank as their grip on each other tightened. Radiation carried away energy, but not angular momentum, so the orbital velocity grew to incomprehensible levels—well into the realm where Einstein's theory of special relativity reigns supreme. With the closing distances, the inevitable occurred as the two twisted knots of spacetime approached each other and merged in a spasm that shook the universe so violently that the energy output briefly outshone the electromagnetic energy output of the entire universe. The two adversaries become one, finally merged together for all eternity. The traces of their ordeal died away, leaving only a fading death scream that spread throughout the cosmos, growing ever fainter. That is, until they passed through Earth. Furthermore, that was the moment that changed everything.

79 ASTRONOMY AND ASTROPHYSICS↗

RNA polymerase motions during promoter melting

All cellular RNA polymerases (RNAPs), from those of bacteria to those of man, possess a clamp that can open and close, and it has been assumed that the open RNAP separates promoter DNA strands and then closes to establish a tight grip on the DNA template. Here, we resolve successive motions of the initiating bacterial RNAP by studying real-time signatures of fluorescent reporters placed on RNAP and DNA in the presence of ligands locking the clamp in distinct conformations. We report evidence for an unexpected and obligatory step early in the initiation involving a transient clamp closure as a prerequisite for DNA melting. Here, we also present a 2.6-angstrom crystal structure of a late-initiation intermediate harboring a rotationally unconstrained downstream DNA duplex within the open RNAP active site cleft. Our findings explain how RNAP thermal motions control the promoter search and drive DNA melting in the absence of external energy sources.

59 BASIC BIOLOGICAL SCIENCES↗

Reversal bending fatigue test system for investigating vibration integrity of spent nuclear fuel during transportation

Transportation packages for spent nuclear fuel (SNF) must meet safety requirements under normal and accident conditions as specified by federal regulations. During transportation, SNF experiences unique conditions and challenges to cladding integrity due to the vibrational and impact loading during road or rail shipment. Oak Ridge National Laboratory (ORNL) has been developing testing capabilities that can be used to improve the understanding of the impacts on SNF integrity due to vibration loading, especially for high burn-up SNF in normal transportation operation conditions. This information can be used to meet the nuclear industry and U.S.Nuclear Regulatory Commission needs in the area of safety and security of SNF storage and transportation operations. The ORNL developed test system can perform reversal bending fatigue testing to evaluate both the static and dynamic mechanical response of SNF rods under simulated loads. The testing apparatus is also designed to meet the challenges of hot cell operation, including remote installation and detachment of the SNF test specimen, in situ test specimen deformation measurement, and implementation of a driving system suitable for use in a hot cell. The system contains a U frame set-up equipped with uniquely designed grip rigs to protect the SNF rod sample and to ensure valid test results, and uses three specially designed linear variable differential transformers to obtain the in situ curvature measurement. A variety of surrogate test rods have been used to develop and calibrate the test system as well as in performing a series of systematic cyclic fatigue tests. The surrogate rods include stainless steel (SS) cladding, SS cladding with cast epoxy and SS cladding with alumina pellet inserts simulating fuel pellets. Testing to date has shown that the interface bonding between the SS cladding and the alumina pellets has a significant impact on the bending response of the test rods as well as their fatigue strength. The failure behaviours observed from tested surrogate rods provide a fundamental understanding of the underlying failure mechanisms of the SNF surrogate rod under vibration,which has not been achieved previously. The newly developed device is scheduled to be installed in the hot cell in summer 2013 to test high burn-up SNF.

high burn up fuel↗

Structural insights into translational recoding by frameshift suppressor tRNA SufJ

The three-nucleotide mRNA reading frame is tightly regulated during translation to ensure accurate protein expression. Translation errors that lead to aberrant protein production can result from the uncoupled movement of the tRNA in either the 5' or 3' direction on mRNA. Here, we report the biochemical and structural characterization of +1 frameshift suppressor tRNA SufJ , a tRNA known to decode four, instead of three, nucleotides. Frameshift suppressor tRNA SufJ contains an insertion 5' to its anticodon, expanding the anticodon loop from seven to eight nucleotides. Our results indicate that the expansion of the anticodon loop of either ASL SufJ or tRNA SufJ does not affect its affinity for the A site of the ribosome. Structural analyses of both ASL SufJ and ASL Thr bound to the Thermus thermophilus 70S ribosome demonstrate both ASLs decode in the zero frame. Although the anticodon loop residues 34–37 are superimposable with canonical seven-nucleotide ASLs, the single C31.5 insertion between nucleotides 31 and 32 in ASL SufJ imposes a conformational change of the anticodon stem, that repositions and tilts the ASL toward the back of the A site. Further modeling analyses reveal that this tilting would cause a distortion in full-length A-site tRNA SufJ during tRNA selection and possibly impede gripping of the anticodon stem by 16S rRNA nucleotides in the P site. Together, these data implicate tRNA distortion as a major driver of noncanonical translation events such as frameshifting.

59 BASIC BIOLOGICAL SCIENCES↗