Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

Measurement of tropospheric carbon monoxide using gas filter radiometers

The measurement of tropospheric carbon monoxide with gas filter radiometers is examined on the basis of the MAPS experiment. The performance characteristics of an instrument that uses the MAPS detectors, broadband filters, and gas cells in a system similar to the GASCOFIL system described by Morrow and Nicholls (1985) is determined. The signal function for two carbon monoxide channels of the MAPS instrument as it was flown in 1981 is shown. The measurements of the lower pressure channel are weighted to a higher altitude. The signal function, when integrated over altitude and multiplied by the normalization constant, yields the value of the signal. Both signal functions approach zero at the top because the gas concentration approaches zero. The present data reduction technique assumes that there are no clouds in the field of view. If clouds are present, the inferred carbon monoxide mixing ratio is too high, and those points must be rejected from the data set.

Reichle, Henry G., Jr.↗

Evaluation of a hydrogen chloride detector for environmental monitoring

The paper describes a hydrogen chloride detector designed to monitor concentrations of hydrogen chloride gas in the ambient environment. The detector was developed for NASA for use in launch vehicle effluent monitoring. The detector operates on chemiluminescence principles with a lower detection limit of less than 5 x 10 to the -3rd ppm (by volume). The hydrogen chloride in the air sample reacts with a bromide-bromate coating in the inlet tube of the instrument producing bromine. Bromine is then quantitated by chemiluminescent oxidation of luminol. The visible light generated in the chemiluminescent reaction is proportional to the hydrogen chloride concentration of the sampled airstream. The detector is most suited to laboratory or field studies where hydrogen chloride is the dominant pollutant, as compared to the interfering species. Interferences include strong acids, acid-forming gases, and halogen gases. Of the interferences investigated the most serious in these groups are hydrochloric and sulfuric acid, sulfur dioxide, and chlorine, respectively. The detector has been in use since 1974 and has been found to be highly portable, rugged, and stable under extreme environmental conditions.

Gregory, G. L.↗

Buffer Gas Acquisition and Storage

The acquisition and storage of buffer gases (primarily argon and nitrogen) from the Mars atmosphere provides a valuable resource for blanketing and pressurizing fuel tanks and as a buffer gas for breathing air for manned missions. During the acquisition of carbon dioxide (CO2), whether by sorption bed or cryo-freezer, the accompanying buffer gases build up in the carbon dioxide acquisition system, reduce the flow of CO2 to the bed, and lower system efficiency. It is this build up of buffer gases that provide a convenient source, which must be removed, for efficient capture Of CO2 Removal of this buffer gas barrier greatly improves the charging rate of the CO2 acquisition bed and, thereby, maintains the fuel production rates required for a successful mission. Consequently, the acquisition, purification, and storage of these buffer gases are important goals of ISRU plans. Purity of the buffer gases is a concern e.g., if the CO, freezer operates at 140 K, the composition of the inert gas would be approximately 21 percent CO2, 50 percent nitrogen, and 29 percent argon. Although there are several approaches that could be used, this effort focused on a hollow-fiber membrane (HFM) separation method. This study measured the permeation rates of CO2, nitrogen (ND, and argon (Ar) through a multiple-membrane system and the individual membranes from room temperature to 193K and 10 kpa to 300 kPa. Concentrations were measured with a gas chromatograph that used a thermoconductivity (TCD) detector with helium (He) as the carrier gas. The general trend as the temperature was lowered was for the membranes to become more selective, In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar.

Parrish, Clyde F.↗

Development of a miniaturized gas chromatograph-mass spectrometer with a microbore capillary column and an array detector

A review is presented of the demonstration of a miniaturized focal plane mass spectrograph using a microbore capillary column with an array detector to measure multiple mass spectra from narrow and closely eluted gas chromatograph peaks. It is shown that the system possesses high sensitivity and a high speed of spectral mass measurements. The combination of the capillary column with the miniaturized mass spectrograph is uniquely suited for the development of a field-portable, high-performance system.

Sinha, Mahadeva P.↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Kariya ( Hildegardia barteri (Mast.) Kosterm) Seed Oil Fatty Acid Methyl Ester Prepared from Basic Catalytic Transesterification

The rising global energy demand, alongside concerns regarding environmental deterioration due to the use of fossil fuels, has spurred extensive investigation into renewable energy alternatives. Biomass-derived biodiesel, especially from lesser-known oil sources, emerges as a promising option. This research focuses on analyzing the fatty acid methyl esters (FAMEs) derived from Kariya (Hildegardia barteri (Mast.) Kosterm) seed oil through basic catalytic transesterification using gas chromatography–flame ionization detector (GC–FID) analysis, assessing its potential as a biodiesel feedstock. Oil extraction from Kariya seeds was carried out using three solvents (n-hexane, ethanol, and a 1:1 blend of hexane and ethanol), followed by transesterification with methanol. Gas chromatography–mass spectrometry (GC–MS) and GC–FID analyses were utilized to identify and quantify FAMEs in the resulting biodiesel. The results revealed various FAMEs, including methyl myristate, methyl palmitate, methyl stearate, methyl oleate, methyl linoleate, and methyl linolenate. Significant differences in FAME composition were observed among the samples, with hexane–ethanol Kariya oil biodiesel (HE-KOB) showing the highest FAME content (76.1%). This combination of solvents exhibited synergistic effects on the composition of HE-KOB, suggesting potential optimization strategies for biodiesel production. Fourier transform infrared spectroscopy (FTIR) provided additional insights into the molecular composition of the biodiesel samples, confirming their biodiesel nature through the identified functional groups such as methyl, methylene, hydrocarbon, ester, aldehyde, and alkene. Thermogravimetric analysis (TGA) for thermal decomposition also gave an insight into FAME composition and its contribution to the degree of conversion of biodiesel to energy. These findings highlight the feasibility of utilizing Kariya seed oil as a biodiesel feedstock, emphasizing the importance of solvent selection and transesterification conditions in optimizing FAME yield and composition. This research contributes to the exploration of underutilized oil sources for sustainable biodiesel production, aligning with the global shift towards cleaner and renewable energy sources.

09 BIOMASS FUELS↗

Efficiency Calibration of FGMS Cold Traps

This plan describes tests to determine the efficiency calibrations for the Fission Gas Monitoring System (FGMS) by the measurements of 85Kr and 133Xe gamma rays. FGMS collects fission product gases released from irradiated Advanced Gas Reactor tristructural-isotropic-coated particle fuel specimens during post-irradiation heating in the Fuel Accident Condition Simulator (FACS) furnace. FGMS is composed of two charcoal-filled, liquid-nitrogen cooled traps that are each monitored by a high purity germanium (HPGe) detector. All irradiated Advanced Gas Reactor fuel specimens contain 85Kr (t1/2 = 10.8 year); however, significant short-lived fission products such as 133Xe (t1/2 = 5.2 day) and 131I (t1/2 = 8.0 day) have decayed away by the time they reach the FACS for testing. In order to measure the releases of these short-lived fission products during safety testing in the FACS furnace, a re-irradiation of samples is necessary in the Neutron Radiography Reactor. This requires the FGMS be calibrated for the fission gas 133Xe, in addition to 85Kr. Because any re-irradiated fuel specimen will have both 85Kr and 133Xe present, the collection efficiency from a mixture of krypton and xenon needs to be determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

Measurement of the free neutron lifetime in a magneto-gravitational trap with in situ detection

Here, in this study, we publish three years of data from the UCNτ experiment performed at the Los Alamos Ultracold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We previously reported a value from our 2017–2018 data for the neutron lifetime of 877.75 ± 0.28 (statistical) +0.22–0.16 (systematic) s. We have collected an additional three years of data reported here for the first time. When all the data from UCNτ are averaged for 2017, 2018, 2020, 2021, and 2022, we report an updated value for the lifetime of 877.83 ± 0.22 (statistical)+0.20–0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on residual gas, and employed four different UCN detector geometries both to reduce the correction required for rate dependence and to explore potential contributions due to phase space evolution.

Cabibbo-Kobayashi-Maskawa matrix↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of a Fast-GCMS System to Measure C2 to C5 Carbonyls, Methanol and Ethanol Aboard Aircraft

Through funding of this proposal, a fast response gas chromatograph/mass spectrometer (FGCMS) instrument to measure less than or equal to C4 carbonyl compounds and methanol was developed for the NASA GTE TRACE-P (Global Tropospheric Experiment, Transport And Chemical Evolution Over The Pacific) mission. The system consists of four major components: sample inlet, preconcentration system, gas chromatograph (GC), and detector. The preconcentration system is a custom-built cryogen-conservative system. The GC is a compact, custom-built unit that can be temperature programmed and rapidly cooled. Detection is accomplished with an Agilent Technologies 5973 mass spectrometer. The FGCMS instrument provides positive identification because the compounds are chromatographically separated and mass selected. During TRACE-P, a sample was analyzed every 5 minutes. The FGCMS limit of detection was between 5 and 75 pptv, depending on the compound. The entire instrument package is contained in a standard NASA instrument rack (106 cm x 61 cm x 135 cm), consumes less than 1200 watts and is fully automated with LabViEW 6i. Methods were developed or producing highly accurate gas phase standards for the target compounds and for testing the system in the presence of potential interferents. This report presents data on these tests and on the general overall performance of the system in the laboratory and aboard the DC-8 aircraft during the mission. Vertical profiles for acetaldehyde, methanol, acetone, propanal, methyl ethyl ketone, and butanal from FGCMS data collected over the entire mission are also presented.

Apel, Eric C.↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Technical Overview IV

Scheduled to launch in late 2021,the Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer Mission designed to open up a new window of investigation --X-ray polarimetry. The IXPE observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging x-ray detector at its focus. An extending boom, deployed on orbit, provides the necessary 4 m focal length. The payload sits atop a 3-axis stabilized spacecraft which, among other things, provides power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of x-ray sources, with follow-on observations of selected targets. IXPE is a partnership between NASA and the Italian Space Agency (ASI).

X-ray polarimetry↗

Survey of Fire Detection Technologies and System Evaluation/Certification Methodologies and Their Suitability for Aircraft Cargo Compartments

As part of the National Aeronautics and Space Administration (NASA) initiated program on global civil aviation, NIST is assisting Federal Aviation Administration in its research to improve fire detection in aircraft cargo compartments. Aircraft cargo compartment detection certification methods have been reviewed. The Fire Emulator-Detector Evaluator (FE/DE) has been designed to evaluate fire detection technologies such as new sensors, multi-element detectors, and detectors that employ complex algorithms. The FE/DE is a flow tunnel that can reproduce velocity, temperature, smoke, and Combustion gas levels to which a detector might be exposed during a fire. A scientific literature survey and patent search have been conducted relating to existing and emerging fire detection technologies, and the potential use of new fire detection strategies in cargo compartment areas has been assessed. In the near term, improved detector signal processing and multi-sensor detectors based on combinations of smoke measurements, combustion gases and temperature are envisioned as significantly impacting detector system performance.

Cleary, T.↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Technical Overview II

The Imaging X-ray Polarimetry Explorer (IXPE) will add polarization to the properties (time, energy, and position) observed in x-ray astronomy. A NASA Astrophysics Small Explorer (SMEX) in partnership with the Italian Space Agency (ASI), IXPE will measure the 2–8-keV polarization of a few dozen sources during the first 2 years following its 2021 launch. The IXPE Observatory includes three identical x-ray telescopes, each comprising a 4-m-focal-length (grazingincidence) mirror module assembly (MMA) and a polarization-sensitive (imaging) detector unit (DU), separated by a deployable optical bench. The Observatory’s Spacecraft provides typical subsystems (mechanical, structural, thermal, power, electrical, telecommunications, etc.), an attitude determination and control subsystem for 3-axis stabilized pointing, and a command and data handling subsystem communicating with the science instrument and the Spacecraft subsystems.

X-ray astronomy↗