Search NASA⌕ Search

SEARCH · Search NASA

Results for “GeTe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Pervasive beyond Room-Temperature Ferromagnetism in a Doped van der Waals Magnet

The existence of long-range magnetic order in low-dimensional magnetic systems, such as the quasi-two-dimensional van der Waals (vdW) magnets, has attracted intensive studies of new physical phenomena. The vdW Fe N GeTe 2 (N = 3, 4, 5; FGT) family is exceptional, owing to its vast tunability of magnetic properties. In particular, a ferromagnetic ordering temperature (T C ) above room temperature at N = 5 (F5GT) is observed. Here, our work shows that, by nickel (Ni) substitution of iron in F5GT, a record high T C =478(6) K is achieved. Importantly, pervasive, beyond room-temperature ferromagnetism exists in almost the entire doping range of the phase diagram of Ni-F5GT. We argue that this striking observation in Ni-F5GT can be possibly due to several contributing factors, including increased 3D magnetic couplings due to the structural alterations.

2-dimensional systems↗

A room temperature polar magnetic metal

The emergence of long-range magnetic order in noncentrosymmetric compounds has stimulated interest in the possibility of exotic spin transport phenomena and topologically protected spin textures for applications in next-generation spintronics. Polar magnets, with broken symmetries of spatial inversion and time reversal, usually host chiral spin textures. This work reports on a wurtzite-structure polar magnetic metal, identified as AA'-stacked (Fe 0.5 Co 0.5 ) 5 GeTe 2 , which exhibits a Néel-type skyrmion lattice as well as a Rashba-Edelstein effect at room temperature. Atomic resolution imaging of the structure reveals a structural transition as a function of Co-substitution, leading to the emergence of the polar phase at 50% Co. We report this discovery reveals an unprecedented layered polar magnetic system for investigating intriguing spin topologies, and it ushers in a promising new framework for spintronics.

36 MATERIALS SCIENCE↗

Tuning the Curie temperature of a two-dimensional magnet/topological insulator heterostructure to above room temperature by epitaxial growth

Heterostructures of two-dimensional (2D) van der Waals (vdW) magnets and topological insulators (TI) are of substantial interest as candidate materials for efficient spin-torque switching, quantum anomalous Hall effect, and chiral spin textures. However, since many of the vdW magnets have Curie temperatures below room temperature, we want to understand how materials can be modified to stabilize their magnetic ordering to higher temperatures. In this work, we utilize molecular beam epitaxy to systematically tune the Curie temperature (T C ) in thin film Fe 3 GeTe 2 /Bi 2 Te 3 from bulklike values (~220 K) to above room temperature by increasing the growth temperature from 300°C to 375°C. For samples grown at 375°C, cross-sectional scanning transmission electron microscopy (STEM) reveals the spontaneous formation of different Fe m Ge n Te 2 compositions (e.g., Fe 5 Ge 2 Te 2 and Fe 7 Ge 6 Te 2 ) as well as intercalation in the vdW gaps, which are possible origins of the enhanced Curie temperature. Furthermore, this observation paves the way for developing various Fe m Ge n Te 2 /TI heterostructures with novel properties.

36 MATERIALS SCIENCE↗

The Portals 4.1 Network Programming Interface

This report presents a specification for the Portals 4 networ k programming interface. Portals 4 is intended to allow scalable, high-performance network communication betwee n nodes of a parallel computing system. Portals 4 is well suited to massively parallel processing and embedded syste ms. Portals 4 represents an adaption of the data movement layer developed for massively parallel processing platfor ms, such as the 4500-node Intel TeraFLOPS machine. Sandia's Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4 is tar geted to the next generation of machines employing advanced network interface architectures that support enh anced offload capabilities.

97 MATHEMATICS AND COMPUTING↗

Investigation of topologically trivial and non-trivial spin textures and their relationships with the topological Hall effect

This proposal has two main goals: (1) to investigate ways to create a variety of spin textures, both topologically trivial and non-trivial, and (2) to establish the relationships between the created spin textures and the topological Hall effect (THE) signal. The approach is achieved by utilizing the van der Waals (vdW) two-dimensional (2D) magnetic materials, such as CrX 3 (X=I, Br, and Cl) and Fe 3 GeTe 2 , transferred onto various substrates with different interactions to create a wide range of spin textures; and utilize Spin helical system, such as Eu metal, and the impact of the thickness.

36 MATERIALS SCIENCE↗

Deciphering and Manipulating Low Dimensional Magnetism

This program investigates the electronic structure and collective quantum phenomena of correlated magnetic materials using advanced angle-resolved photoemission spectroscopy (ARPES) and complementary probes, with a focus on three interrelated material families: (i) the semiconducting van der Waals magnet Cr₂Ge₂Te₆, (ii) metallic Fe-based van der Waals magnets including Fe₃GeTe₂ Fe₃GaTe₂, and Fe5GeTe₂, and (iii) kagome magnets such as FeGe, FeSn, and CsV₃Sb₅/CsCr₃Sb₅. In Cr₂Ge₂Te₆, our work established how spin excitations develop across a dimensional crossover as spins establish correlation to form long range order, providing a clean platform to isolate correlation effects. In metallic Fe-based magnets, we uncovered the dichotomy between flat and dispersive bands, revealed momentum-dependent electronic reconstructions tied to magnetic order, and demonstrated reversible, non-volatile electronic switching near room temperature, highlighting the strong coupling among spin, charge, and lattice degrees of freedom in metallic ferromagnets. In kagome magnets, we identified charge density wave formation, symmetry breaking, flat-band renormalization, and field-induced momentum-dependent electronic anisotropy, elucidating how geometric frustration and electronic correlations conspire to generate emergent quantum states. Collectively, these results establish a unified microscopic framework for understanding correlation-driven electronic reconstruction, symmetry breaking, and collective order across semiconducting and metallic magnetic systems, advancing DOE mission goals in quantum materials discovery and control.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neuromorphic Photonics Based on Phase Change Materials

Neuromorphic photonics devices based on phase change materials (PCMs) and silicon photonics technology have emerged as promising solutions for addressing the limitations of traditional spiking neural networks in terms of scalability, response delay, and energy consumption. In this review, we provide a comprehensive analysis of various PCMs used in neuromorphic devices, comparing their optical properties and discussing their applications. We explore materials such as GST (Ge 2 Sb 2 Te 5 ), GeTe-Sb 2 Te 3 , GSST (Ge 2 Sb 2 Se 4 Te 1 ), Sb 2 S 3 /Sb 2 Se 3 , Sc 0.2 Sb 2 Te 3 (SST), and In 2 Se 3 , highlighting their advantages and challenges in terms of erasure power consumption, response rate, material lifetime, and on-chip insertion loss. By investigating the integration of different PCMs with silicon-based optoelectronics, this review aims to identify potential breakthroughs in computational performance and scalability of photonic spiking neural networks. Further research and development are essential to optimize these materials and overcome their limitations, paving the way for more efficient and high-performance photonic neuromorphic devices in artificial intelligence and high-performance computing applications.

36 MATERIALS SCIENCE↗

Efficient Optical Control of Magnon Dynamics in van der Waals Ferromagnets

Optical control of magnons in two-dimensional (2D) materials promises new functionalities for spintronics and magnonics in atomically thin devices. Here, we report control of magnon dynamics, using laser polarization, in a ferromagnetic van der Waals (vdW) material, Fe 3.6 Co 1.4 GeTe 2 . The magnon amplitude, frequency, and lifetime are controlled and monitored by time-resolved pump-probe spectroscopy. We show substantial (over 25%) and continuous modulation of magnon dynamics as a function of incident laser polarization. Our results suggest that the modification of the effective demagnetization field and magnetic anisotropy by the pump laser pulses with different polarizations is due to anisotropic optical absorption. This implies that pump laser pulses modify the local spin environment, which enables the launch of magnons with tunable dynamics. Our first-principles calculations confirm the anisotropic optical absorption of different crystal orientations. Our findings suggest a new route for the development of opto-spintronic or opto-magnonic devices.

36 MATERIALS SCIENCE↗

ACROSS: Enabling Time Domain and Multi-Messenger Astrophysics

The U.S. Astro2020 Decadal Survey recommended an investment in Time Domain and Multi-Messenger Astrophysics (TDAMM) as the top-priority sustaining activity in space for the coming decade. One aspect of NASA’s response to this rec-ommendation is a pilot project, the Astrophysics Cross-Observatory Science Support (ACROSS) Initiative, designed to provide support to both missions and observers as they pursue TDAMM science. In this talk, we present our observations of needs in the community and initial plans for ACROSS activities, including services to facilitate and improve cross-mission follow-up planning and execution; a multi-messenger web portal with links to existing mission resources, community tools, and information tar-geted for TDAMM General Observers; development of "Smart Target of Opportunity submission page" proof-of-concepts; and ongoing development of a potential TDAMM general observing competitive grant solicitation. While the initial focus has been to en-hance coordination between NASA missions, we are eager to work with ground-based and international partners as well. We invite discussion with both missions and ob-servers to better understand their needs and concerns as ACROSS progresses. Here we present our efforts on the web-portal and API, along with our development to support NASA’s BurstCube mission.

T B Humensky↗

Crystallization Times of Ge-Te Phase Change Materials as a Function of Composition

The crystallization times of Ge-Te phase change materials with variable Ge concentrations (29.5-72.4 at. %) were studied. A very strong dependence of the crystallization time on the composition for as-deposited, amorphous films was confirmed, with a minimum for the stoichiometric composition GeTe. The dependence is weaker for melt-quenched, amorphous material and crystallization times are between one to almost four orders of magnitude shorter than for as-deposited materials. This is promising for applications because recrystallization from the melt-quenched phase is the relevant process for optical and solid state memory, and fast crystallization and weak dependence on compositional variations are desirable.

36 MATERIALS SCIENCE↗

Whole Brain Radiotherapy With Hippocampal Avoidance and Simultaneous Integrated Boost for 1-3 Brain Metastases: A Feasibility Study Using Volumetric Modulated Arc Therapy

Purpose: To evaluate the feasibility of using volumetric modulated arc therapy (VMAT) to deliver whole brain radiotherapy (WBRT) with hippocampal avoidance and a simultaneous integrated boost (SIB) for one to three brain metastases. Methods and Materials: Ten patients previously treated with stereotactic radiosurgery for one to three brain metastases underwent repeat planning using VMAT. The whole brain prescription dose was 32.25 Gy in 15 fractions, and SIB doses to brain metastases were 63 Gy to lesions >=2.0 cm and 70.8 Gy to lesions <2.0 cm in diameter. The mean dose to the hippocampus was kept at <6 Gy{sub 2}. Plans were optimized for conformity and target coverage while minimizing hippocampal and ocular doses. Plans were evaluated on target coverage, prescription isodose to target volume ratio, conformity number, homogeneity index, and maximum dose to prescription dose ratio. Results: Ten patients had 18 metastases. Mean values for the brain metastases were as follows: conformity number = 0.73 +- 0.10, target coverage = 0.98 +- 0.01, prescription isodose to target volume = 1.34 +- 0.19, maximum dose to prescription dose ratio = 1.09 +- 0.02, and homogeneity index = 0.07 +- 0.02. For the whole brain, the mean target coverage and homogeneity index were 0.960 +- 0.002 and 0.39 +- 0.06, respectively. The mean hippocampal dose was 5.23 +- 0.39 Gy{sub 2}. The mean treatment delivery time was 3.6 min (range, 3.3-4.1 min). Conclusions: VMAT was able to achieve adequate whole brain coverage with conformal hippocampal avoidance and radiosurgical quality dose distributions for one to three brain metastases. The mean delivery time was under 4 min.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Predictive of Symptomatic Radiation Injury After Linear Accelerator-Based Stereotactic Radiosurgery for Intracerebral Arteriovenous Malformations

Purpose: To investigate predictive factors in the development of symptomatic radiation injury after treatment with linear accelerator-based stereotactic radiosurgery for intracerebral arteriovenous malformations and relate the findings to the conclusions drawn by Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC). Methods and Materials: Archived plans for 73 patients who were treated at the British Columbia Cancer Agency were studied. Actuarial estimates of freedom from radiation injury were calculated using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used for analysis of incidence of radiation injury. Log-rank test was used to search for dosimetric parameters associated with freedom from radiation injury. Results: Symptomatic radiation injury was exhibited by 14 of 73 patients (19.2%). Actuarial rate of symptomatic radiation injury was 23.0% at 4 years. Most patients (78.5%) had mild to moderate deficits according to Common Terminology Criteria for Adverse Events, version 4.0. On univariate analysis, lesion volume and diameter, dose to isocenter, and a V{sub x} for doses {>=}8 Gy showed statistical significance. Only lesion diameter showed statistical significance (p < 0.05) in a multivariate model. According to the log-rank test, AVM volumes >5 cm{sup 3} and diameters >30 mm were significantly associated with the risk of radiation injury (p < 0.01). The V{sub 12} also showed strong association with the incidence of radiation injury. Actuarial incidence of radiation injury was 16.8% if V{sub 12} was <28 cm{sup 3} and 53.2% if >28 cm{sup 3} (log-rank test, p = 0.001). Conclusions: This study confirms that the risk of developing symptomatic radiation injury after radiosurgery is related to lesion diameter and volume and irradiated volume. Results suggest a higher tolerance than proposed by QUANTEC. The widely differing findings reported in the literature, however, raise considerable uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Outcomes of Fractionated Stereotactic Radiation Therapy for Pituitary Adenomas at the BC Cancer Agency

Purpose: To assess the long-term disease control and toxicity outcomes of fractionated stereotactic radiation therapy (FSRT) in patients with pituitary adenomas treated at the BC Cancer Agency. Methods and Materials: To ensure a minimum of 5 years of clinical follow-up, this study identified a cohort of 76 patients treated consecutively with FSRT between 1998 and 2007 for pituitary adenomas: 71% (54/76) had nonfunctioning and 29% (22/76) had functioning adenomas (15 adrenocorticotrophic hormone-secreting, 5 growth hormone-secreting, and 2 prolactin-secreting). Surgery was used before FSRT in 96% (73/76) of patients. A median isocenter dose of 50.4 Gy was delivered in 28 fractions, with 100% of the planning target volume covered by the 90% isodose. Patients were followed up clinically by endocrinologists, ophthalmologists, and radiation oncologists. Serial magnetic resonance imaging was used to assess tumor response. Results: With a median follow-up time of 6.8 years (range, 0.6 - 13.1 years), the 7-year progression-free survival was 97.1% and disease-specific survival was 100%. Of the 2 patients with tumor progression, both had disease control after salvage surgery. Of the 22 patients with functioning adenomas, 50% (11/22) had complete and 9% (2/22) had partial responses after FSRT. Of the patients with normal pituitary function at baseline, 48% (14/29) experienced 1 or more hormone deficiencies after FSRT. Although 79% (60/76) of optic chiasms were at least partially within the planning target volumes, no patient experienced radiation-induced optic neuropathy. No patient experienced radionecrosis. No secondary malignancy occurred during follow-up. Conclusion: In this study of long-term follow-up of patients treated for pituitary adenomas, FSRT was safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Stereotactic Radiotherapy Treatment Delivery Technique for Base-Of-Skull Meningiomas

This study compares static conformal field (CF), intensity modulated radiotherapy (IMRT), and dynamic arcs (DA) for the stereotactic radiotherapy of base-of-skull meningiomas. Twenty-one cases of base-of-skull meningioma (median planning target volume [PTV] = 21.3 cm{sup 3}) previously treated with stereotactic radiotherapy were replanned with each technique. The plans were compared for Radiation Therapy Oncology Group conformity index (CI) and homogeneity index (HI), and doses to normal structures at 6 dose values from 50.4 Gy to 5.6 Gy. The mean CI was 1.75 (CF), 1.75 (DA), and 1.66 (IMRT) (p < 0.05 when comparing IMRT to either CF or DA plans). The CI (IMRT) was inversely proportional to the size of the PTV (Spearman's rho = -0.53, p = 0.01) and at PTV sizes above 25 cm{sup 3}, the CI (IMRT) was always superior to CI (DA) and CI (CF). At PTV sizes below 25 cm{sup 3}, there was no significant difference in CI between each technique. There was no significant difference in HI between plans. The total volume of normal tissue receiving 50.4, 44.8, and 5.6 Gy was significantly lower when comparing IMRT to CF and DA plans (p < 0.05). There was significantly improved dose sparing for the brain stem and ipsilateral temporal lobe with IMRT but no significant difference for the optic chiasm or pituitary gland. These results demonstrate that stereotactic IMRT should be considered to treat base-of-skull meningiomas with a PTV larger than 25 cm{sup 3}, due to improved conformity and normal tissue sparing, in particular for the brain stem and ipsilateral temporal lobe.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac

Purpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 Multiplication-Sign 1 to 40 Multiplication-Sign 40 cm{sup 2}. Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. Results: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 Multiplication-Sign 1 cm{sup 2}. Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 Multiplication-Sign 1 cm{sup 2} field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. Conclusions: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.

60 APPLIED LIFE SCIENCES↗

TH-C-19A-03: Characterization of the Dose Per Pulse Dependence of Various Detectors Used in Quality Assurance of FFF Treatment Plans

Purpose: To present the dose per pulse dependence of various QA devices under Flattening Filter Free (FFF) conditions. Methods: Air and liquid filled ion chamber arrays, diode arrays, radiochromic film and optically stimulated luminescence detectors were investigated. All detectors were irradiated under similar conditions of varying dose per pulse on a TrueBeam linac. Dose per pulse was controlled by varying SSD from 70 to 160 cm providing a range from ~0.5 to ~3 mGy per pulse. MU rates of up to 2400 MU/min for 10X FFF and 1400 MU/min for the 6X FFF beam were used. Beam pulses were counted using the Profiler™ diode array and pulse timing was confirmed by examining linac node files. Delivered doses were calculated with the Eclipse™ treatment planning system. Results: The detectors show a range of behaviors depending on the detector type, as expected. Diode arrays show up to 4% change in sensitivity (sensitivity increases with increasing dose per pulse) over the range tested. Air and liquid ion chambers arrays show a change in sensitivity of up to 3% (air) and 6% (liquid) (sensitivity decreases with increasing dose per pulse) while film and OSLD do not demonstrate a dependence on dose per pulse. Conclusion: Dependence of detector response on dose per pulse varies considerably depending on detector design. Interplay between dose per pulse and MU rate also exists for some detectors. Due diligence is required to characterize detector response prior to implementation of a QA protocol for FFF treatment delivery. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. We intend to further investigate the implications of this for VMAT FFF patient specific quality assurance. T Karan and F Viel have received partial funding through the Varian Research program.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 27: Flattening Filter Free VMAT Quality Assurance: Dose Rate Considerations for Detector Response

Introduction: Radiation detector responses can be affected by dose rate. Due to higher dose per pulse and wider range of mu rates in FFF beams, detector responses should be characterized prior to implementation of QA protocols for FFF beams. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. This study looks at the dose per pulse variation throughout a 3D volume for typical VMAT plans and the response characteristics for a variety of detectors, and makes recommendations on the design of QA protocols for FFF VMAT QA. Materials and Methods: Linac log file data and a simplified dose calculation algorithm are used to calculate dose per pulse for a variety of clinical VMAT plans, on a voxel by voxel basis, as a function of time in a cylindrical phantom. Diode and ion chamber array responses are characterized over the relevant range of dose per pulse and dose rate. Results: Dose per pulse ranges from <0.1 mGy/pulse to 1.5 mGy/pulse in a typical VMAT treatment delivery using the 10XFFF beam. Diode detector arrays demonstrate increased sensitivity to dose (+./− 3%) with increasing dose per pulse over this range. Ion chamber arrays demonstrate decreased sensitivity to dose (+/− 1%) with increasing dose rate over this range. Conclusions: QA protocols should be designed taking into consideration inherent changes in detector sensitivity with dose rate. Neglecting to account for changes in detector response with dose per pulse can lead to skewed QA results.

60 APPLIED LIFE SCIENCES↗