Multiple-gridding of the Euler equations with an implicit scheme

The multiple-grid scheme of Ni (1981) for the solution of the unsteady Euler equations for quasi-one-dimensional transonic flow problems is analyzed according to its ability to accelerate convergence to a steady state solution, its applicability to an implicit scheme, its accuracy, and its stability limits. This scheme is applied successfully to McCormack's (1981) implicit method of solving quasi-one-dimensional transonic flow problems for CFL numbers significantly greater than unity. It is determined that the second order accuracy of this implicit method is preserved by employing the multiple gridding. However, stability limitations that are flow dependent are introduced into the implicit method by the use of the multiple-grid scheme which will curtail its use under certain flow conditions. A scaling modification for the multiple grid scheme is developed which further improves its performance when used with explicit and artificially-damped implicit methods without any increase in computational work.

Stubbs, R. M.↗

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)↗

NASA Langley FUN3D Analyses in Support of the 1st AIAA Stability and Control Prediction Workshop

This work summarizes the results of FUN3D analyses conducted for the 1st AIAA Stability and Control Workshop on behalf of participants from the NASA Langley Research Center. The workshop was created to establish best practices for the prediction of stability and control derivatives using computational fluid dynamics and assess the limitations of these methods when those best practices are applied. The inaugural workshop considered the ONERA version of the NASA/Boeing Common Research Model, which includes the wing, body, horizontal tail, and a vertical tail designed by ONERA. Wind tunnel data at small sideslip angles remain unpublished and served as ‘blind’ data for computational comparisons. The present research generated workshop test case data using the NASA FUN3D code, which is a parallelized, unstructured, node-based, finite-volume discretization, Reynolds-averaged Navier-Stokes flow solver. Steady- state numerical simulations were conducted for workshop test cases investigating the following: grid convergence, Mach number effect on static stability, wind tunnel sting increments, static stability-derivative calculations, and a sideslip angle sweep. Results were generated for two series of unstructured, mixed-element grids, one set provided by the workshop and another set created using the HeldenMesh grid generation software. The results provided include total- and component-level breakdowns of the force and moment coefficients, in addition to sectional pressure distributions for the wing and tail components for comparisons to wind tunnel data.

CFD↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

eMosaic: Electrification Mosaic Platform for Grid Informed Smart Charging Management (Final Scientific/Technical Report)

ABB (Prime Contractor), in collaboration with its partners at the Utah State University (USU), Idaho National Laboratory, Rocky Mountain Power (RMP), and Electric Power Engineers (EPE), have performed research, development, and wide scale demonstration of a scalable and resilient Electrification Mosaic (eMosaic) platform for Smart Charge Management (SCM) for Electric Vehicle Infrastructure. Work was completed under DE EE0009194, titled “eMosaic Electrification Mosaic Platform for Grid Informed Smart Charging Management”, funded by the US Department of Energy. The project members developed algorithms that provide localized and bulk grid services and that reduce and stabilize costs all the way down the supply chain to the PEV owner through SCM. This platform aggregates telemetry from multiple data sources as pieces of the larger picture including personal, private fleet or transportation EVs, fast chargers and other supply equipment, weather service information, and geographically distributed charging sites such as public lots, garage and retail, and private or shared usage depots. ABB and the project team designed, tested, and improved a charging management system at local/edge and cloud levels. The ultimate objective of the project was to convincingly demonstrate that the developed secure eMosaic plat-form can be readily and favorably adopted by diverse utilities and site owners at scale. This was achieved through a demonstration plan with field deployment at several physical sites across 4 states and additional scalable simulation from high fidelity charging models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variable Transmission Line Ratings

This paper outlines the concept of variable-transmission facility ratings. This topic is of heightened importance following the recent Federal Energy Regulatory Commission (FERC) Order No. 881 which requires the implementation of ambient adjusted ratings (AARs) for FERC jurisdictional portions of the transmission system. Additionally, FERC issued an Advanced Notice of Proposed Rulemaking (ANOPR) implying a future order on Dynamic Line Rating (DLR) requirements. The various types of facility-rating methodologies will be discussed with a focus on how they can benefit the stability, capacity, and reliability of the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Further development of XTRAN3S computer program

This report describes modifications and enhancements to XTRAN3S, a computer program for aerodynamic, static aeroelastic, and dynamic aeroelastic analysis of three-dimensional wings in the transonic speed regime. Modifications to the program include incorporation of a viscous boundary layer, modified coefficient and generalized force integration, direct input of airfoil surface coordinates and slopes, variable dimensions of computational arrays and a modified grid mapping transformation to improve computational stability for highly swept and tapered planforms. Results obtained with the modified program are included. Modifications discussed but not incorporated include a state matrix integration method, enhanced vectorization, and use of a cartesian physical mesh.

Borland, C. J.↗

Boundary conditions for the solution of compressible Navier-Stokes equations by an implicit factored method

A method is presented for formulating the boundary conditions in implicit finite-difference form needed for obtaining solutions to the compressible Navier-Stokes equations by the Beam and Warming implicit factored method. The usefulness of the method was demonstrated (a) by establishing the boundary conditions applicable to the analysis of the flow inside an axisymmetric piston-cylinder configuration and (b) by calculating velocities and mass fractions inside the cylinder for different geometries and different operating conditions. Stability, selection of time step and grid sizes, and computer time requirements are discussed in reference to the piston-cylinder problem analyzed.

Shih, T. I.-P.↗

On the dynamics of some grid adaption schemes

The dynamics of a one-parameter family of mesh equidistribution schemes coupled with finite difference discretisations of linear and nonlinear convection-diffusion model equations is studied numerically. It is shown that, when time marched to steady state, the grid adaption not only influences the stability and convergence rate of the overall scheme, but can also introduce spurious dynamics to the numerical solution procedure.

Sweby, Peter K.↗

Predicting Turbulent Convective Heat Transfer in Three-Dimensional Duct Flows

The performance of an explicit algebraic stress model is assessed in predicting the turbulent flow and forced heat transfer in straight ducts, with square, rectangular, trapezoidal and triangular cross-sections, under fully developed conditions over a range of Reynolds numbers. Iso-thermal conditions are imposed on the duct walls and the turbulent heat fluxes are modeled by gradient-diffusion type models. At high Reynolds numbers (>/= 10(exp 5)), wall functions are used for the velocity and temperature fields; while at low Reynolds numbers damping functions are introduced into the models. Hydraulic parameters such as friction factor and Nusselt number are well predicted even when damping functions are used, and the present formulation imposes minimal demand on the number of grid points without any convergence or stability problems. Comparison between the models is presented in terms of the hydraulic parameters, friction factor and Nusselt number, as well as in terms of the secondary flow patterns occurring within the ducts.

Rokni, M.↗

Predicting Turbulent Convective Heat Transfer in Fully Developed Duct Flows

The performance of an explicit algebraic stress model (EASM) is assessed in predicting the turbulent flow and forced heat transfer in both straight and wavy ducts, with rectangular, trapezoidal and triangular cross-sections, under fully developed conditions. A comparison of secondary flow patterns. including velocity vectors and velocity and temperature contours, are shown in order to study the effect of waviness on flow dynamics, and comparisons between the hydraulic parameters. Fanning friction factor and Nusselt number, are also presented. In all cases. isothermal conditions are imposed on the duct walls, and the turbulent heat fluxes are modeled using gradient-diffusion type models. The formulation is valid for Reynolds numbers up to 10(exp 5) and this minimizes the need for wall functions that have been used with mixed success in previous studies of complex duct flows. In addition, the present formulation imposes minimal demand on the number of grid points without any convergence or stability problems. Criteria in terms of heat transfer and friction factor needed to choose the optimal wavy duct cross-section for industrial applications among the ones considered are discussed.

Rokni, Masoud↗

Battery Storage Unlocked: Lessons Learned From Emerging Economies

The Clean Energy Ministerial (CEM) is a global forum that promotes policies and programs that advance clean energy technology. The CEM's mission is to bring together a community of global leaders to scale clean energy, amplifying the impact to all the sectors of the economy and applying a whole-of-society approach to meet collective climate and clean energy goals. At COP28 in Dubai, United Arab Emirates, the CEM announced the Supercharging Battery Storage Initiative as a vehicle to accelerate battery storage deployment around the world. The initiative supports countries around the world in co-creating strategies that enhance policy, regulation, supply chain, manufacturing, and financing solutions for battery energy storage deployment. Additionally, the initiative seeks to reduce the cost of the technology and promote diversified, sustainable, and secure supply chains (CEM n.d.). Through international collaboration, the initiative supports the integration of renewable energy globally, while securing the stability and reliability of the electricity grid.

batteries↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Signal Stability Constrained Optimal Power Flow of Inverter-Dominated Power Systems with Flexible Operation Mode Selection

Given the intermittence and low inertia nature of inverter-based resources (IBRs), modern power systems with high penetration of IBRs challenge the conventional optimal power flow (OPF) analysis and the system may experience unexpected failures if stability constraints are not incorporated. This study proposes a small-signal stability-constrained OPF (SSSC-OPF) with flexible operation mode selection between grid-forming (GFM) and grid-following (GFL) modes for IBRs to address these challenges. The approach aims to maintain system stability with a sufficient stability margin while minimizing operation costs. The effectiveness of the proposed method is validated through extensive case studies on the IEEE 14-bus system. The results demonstrate that the proposed method is able to support system-level power flow analysis, reduce generation costs, and ensure stability under various disturbances.

grid-following↗