Renewable Integration in Hybrid ac-dc Systems using Multi-port Autonomous Reconfigurable Solar power plant (MARS)

To increase inertia and improve primary frequency response of future grids, grid-forming inverters connecting PV to grid and energy storage systems (ESSs) are likely to play an important role. Moreover, high-voltage direct current (HVdc) links will also be an enabler to transfer remote PV generation and for improved grid stability. That is, with increased penetration of PV, discrete development of PV and ESS connecting to transmission ac grid and HVdc links is one of the solutions for stable operation of grid. Here, an integrated concept for integration of PV and ESS to transmission ac grid and HVdc links is proposed that is named as multi-port autonomous reconfigurable solar power plant (MARS). The proposed integrated development reduces the cost associated with respect to discrete development of PV-ESS systems connecting to transmission ac grid and HVdc links. The integrated development incorporates advanced control methods to provide inertial and primary frequency response, reactive power support, and transient stability to manage PV and ESS resources. In this paper, high-fidelity switched system model of the integrated system and grids are developed and detailed simulation results are provided to showcase the stable operation of the integrated system and provision of grid support functions.

14 SOLAR ENERGY↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Broadband piezoelectric energy harvesting microgyroscopes: Design and nonlinear analysis

Small devices in remote or difficult-to-reach areas can benefit from harvesting energy from mechanical wasted energy, which reduces the requirement for a new power source. A multi-purpose energy harvesting microgyroscope system based on piezoelectric materials is suggested. The necessity of taking spatially varying electrostatic forces is examined. Considering the effects of the system's width and thickness, DC voltage, and angular speed the systems inherent frequencies are found. The partial differential equations describing the system's dynamics are numerically solved by using the differential quadrature method. Further, the numerical analysis enables to identify the optimal system design for broadband energy harvesting. The simulation results reveal that a system with a non-symmetric beam design is adequate for broadband energy harvesting. This is associated with the applied DC voltage, which may be modified to improve the broadband frequency of the system. It is concluded that the nonlinear softening effects create a broadband frequency response with high voltage output. However, DC and AC voltages need to be carefully selected in order to avoid the dynamic pull-in.

30 DIRECT ENERGY CONVERSION↗

Modeling of Grid-Forming and Grid-Following Inverters for Dynamic Simulation of Large-Scale Distribution Systems

Historically, distribution system planning studies mainly focused on steady state and quasi-steady state analysis, with limited attention paid to dynamic analysis. This paper develops three-phase, electromechanical models for both grid-forming and grid-following inverters, and integrates them into an open source, three-phase distribution network solver, thereby enabling dynamic simulation of large-scale, three-phase unbalanced distribution systems with high penetration of inverter-based DERs. The proposed inverter models are validated against electromagnetic simulation and field test data from the CERTS/AEP microgrid testbed, and simulated in an islanded 5252 node distribution system in the GridLAB-D simulation environment. Simulation verifies the effectiveness of the proposed inverter models for large-scale distribution system analysis. Finally, study results show that compared to traditional grid-following inverters, the high penetration of grid-forming inverters can improve the voltage and frequency stability of islanded distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation: Preprint

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗

Complementary Electrolyte Design for Li Metal Batteries in Electric Vehicle Applications

In this report a complementary electrolyte system with 0.8 M lithium bis(fluorosulfonylimide) (LiFSI) salt and 2 wt % lithium perchlorate (LiCLO4) additive in fluoroethylene carbonate (FEC)/ethyl methyl carbonate (EMC) solution enables not only stable cycling of lithium metal batteries (LMBs) with practical loading (<30 μm lithium anode, cathode loading > 4 mAh/cm 2 ) but also outstanding degradation stability toward the end of cycle life when compared to the conventional electrolyte. Although the use of LiFSI salt can increase the electrolyte conductivity and lengthen the cycle life of LMBs, the aged lithium anode morphology formed by the sacrificial decomposition of LiFSI is highly porous, leading to an abrupt cell capacity drop toward the end of cycling. Moreover, the inability to stop aluminum corrosion by the LiFSI-based electrolyte also causes cracking of the cathode tab during prolonged cycling. It is observed that a highly porous aged lithium consumed electrolyte at a higher rate, leading to the dry-out of electrolyte solvents. On the contrary, dense aged lithium anode morphology increased the localized current applied on the lithium, causing the formation of lithium dendrite. Thus, porosity control is the key to enhance battery performance. In this complementary system, LiClO 4 was introduced as an advanced additive to not only improve the capacity retention rate but also mitigate the abrupt capacity drop toward the end of cycle life because LiClO 4 acted as a pore astringent reducing the porosity of the aged lithium metal anode to the desired level. Moreover, the addition of LiClO 4 can also suppress the AI corrosion, allowing stable high-voltage cycling of LMBs. The synergistic effect of combining LiFSI salt and a LiClO 4 additive leads to an electrolyte system that can facilitate the application of high-energy LMBs with practical electrode loading.

25 ENERGY STORAGE↗

Radio frequency and DC high voltage breakdown of high pressure helium, argon, and xenon

Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10 MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying and Suppressing Proton Intercalation to Enable High-Voltage Zn-Ion Batteries

Rechargeable Zn-ion batteries (ZIBs) are widely regarded as promising candidates for large-scale energy storage applications. Like most multivalent battery systems (based on Zn, Mg, Ca, etc.), further progress in ZIB development relies on the discovery and design of novel cathode hosts capable of reversible Zn 2+ (de)intercalation. This work employs VPO 4 F as a ZIB cathode and explores ensuing intercalation mechanisms along with interfacial dynamics during cycling to quantify the water dynamics in concentrated electrolytes and/or hybrid aqueous-non aqueous (HANEs) electrolyte(s). Like most oxide-based cathode materials, proton (H + ) intercalation dominates electrochemical activity during discharge of Zn x H y VPO 4 F in aqueous media due to the hydroxylated nature of the interface. Such H + electrochemistry diminishes low-rate and/or long-term electrochemical performance of ZIBs which inhibits implementation for practical applications. Thus, quantification of the water dynamics in various electrolytes is demonstrated for the first time. Detailed investigations of water mobility in various concentrated electrolytes and HANEs systems enable the design of an electrolyte that enhances aqueous anodic stability and suppresses water/proton activity during discharge. Tuning Zn 2+ /H + intercalation kinetics simultaneously allows for a high voltage (1.9 V) and long-lasting aqueous zinc-ion battery: Zn|Zn(OTf) 2 · n H 2 O-PC|Zn x H y VPO 4 F.

25 ENERGY STORAGE↗

Runtime Systems for Energy Efficiency in Advanced Computing Systems

As heterogeneous systems become increasingly popular for both mobile and high-performance computing, conventional efficiency techniques such as dynamic voltage and frequency scaling (DVFS) fail to account for the tightly coupled and varied nature of systems on a chip (SoCs). In this work, we explore the impact of system unaware DVFS techniques on a mobile SoC under three benchmark suites: Chai, Rodinia, and Antutu. We then analyze performance trends across the suites to identify a set of consistent operating points that optimally balance power and performance across the system. The consistent operating points are then constructed into a dependency graph which can be leveraged to produce a more effective, SoC-wide governor.

97 MATHEMATICS AND COMPUTING↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

FY25 Mid-Year Report: FNCL Enhancements Implementation

During the first half of FY25 the FNCL team has made consistent progress toward the completion of our project goals. The FNCL prototype panel design has been successfully applied to a fully instrumented 3-panel system which is actively under construction. The FNCL Demonstrator System contains solid scintillators instrumented with SiPMs, which operate on an updated CAEN digitizer, requires no high-voltage, and has a smaller overall footprint. The onboard software will include the LLNL-developed GMM-PSD signal processing. Later this year the system will be experimentally tested alongside the baseline FNCL instrument at LLNLs ISSA facility. In addition to a full systems test, the performance of a DD generator for active interrogation measurements compared to the standard AmLi source will be established for both systems. The data collected at the ISSA facility will be used to experimentally validate the FNCL-Fast Isotopic Fuel Assay’s (FIFA) capability to measure U-235 loading and to predict gadolinium poison content with passive interrogation. The FNCL-FIFA modal was benchmarked with simulation-based data and a user-friendly GUI was added earlier this year. Three separate codes have been submitted to the LLNL ESW system for review prior to their transfers. These include the Predictive Modeling Response toolkit, GMM-PSD firmware beta version, and the FNCL-FIFA analysis package with GUI and user documentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.