Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Lifting the Garage Door on Spawn, An Open-Source BEM-Controls Engine

Spawn is the latest whole-building energy simulation engine developed by the US Department of Energy, National Labs and industry. Whereas EnergyPlus was designed as a successor to DOE-2, Spawn is not a direct successor of–nor is it intended as an imminent replacement for– EnergyPlus. Instead, Spawn reuses parts of EnergyPlus while supporting new use cases in HVAC and controls. Spawn is intended to provide several capabilities that significantly advance beyond EnergyPlus. It is intended to support the evaluation of novel HVAC and district energy systems in a more physically realistic way. Critically, it can model control in a physically realistic way, using portable specifications that can be compiled for execution on control platforms. Spawn is also intended to support co-simulation in an intrinsic way to enable integration with third-party models. This paper describes the software architecture of Spawn from model authoring to compilation and simulation. It explains how Spawn reuses the envelope and daylighting modules of EnergyPlus and couples them to HVAC and control models from the Modelica Buildings Library using the Functional Mockup Interface (FMI) standard. It presents a number of examples that: i) validate Spawn’s coupled simulation approach by comparing its results to those of EnergyPlus, ii) illustrate the Spawn methodology for modeling and simulating HVAC systems, and iii) evaluate the performance of Spawn’s Quantized State System (QSS) time integration algorithms

Wetter, Michael↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchronization and Rebound Effects in Residential Loads

Increasing fuel prices and capacity investment deferral place an increasing demand for peak reduction from distribution level systems. Residential and commercial devices, such as HVAC systems and water heaters, are increasingly involved in load control programs, and their use may generate synchronization and rebound effects, such as artificial peaks caused by device optimization. While there have been concerns over device synchronization, few studies quantify the extent of this effect with numerical values. In this study, we attempt to investigate whether control efforts result in device synchronization or rebound effects. We focus on three clustering methods – Ward’s clustering, Euclidean K-means, and Density-based spatial clustering of applications with noise – to evaluate the extent of synchronization of a fleet of water heaters and HVAC systems in Atlanta, Georgia. Our findings show that synchronization and rebound effects are present in the neighborhood’s water heaters, but none were found in the HVAC systems. Further, high usage water heaters are more susceptible to synchronization and rebound effects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Ecosystem-Level Biomimicry for the Built Environment: Adopting Systems Ecology Principles for the Control of Heterogeneous Energy Systems

This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.

biomimicry↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance evaluation of the ASHRAE Guideline 36 control and reinforcement learning–based control using field measurements

This study evaluates the energy performance of ASHRAE Guideline 36–compliant control (ASHRAE 36 control) and reinforcement learning (RL)–based control through experimental field tests and a simulation study. Three field tests were conducted at Oak Ridge National Laboratory’s commercial building test facility in Oak Ridge, Tennessee: a baseline with a baseline conventional control, a test with ASHRAE 36 control, and a test with RL-based control. The selected ASHRAE 36 controls were trim and respond control, as well as variable air volume (VAV) box control. We compared the measured supply air temperature of the rooftop unit, VAV box supply air temperature, and VAV box supply airflow rate across the three test cases. The field data indicated that ASHRAE 36 controls operated as specified by ASHRAE Guideline 36. Based on these data, ASHRAE 36 control achieved a 45 % reduction in hourly averaged HVAC energy consumption compared with the baseline, and RL-based control achieved a 66 % reduction. These potential annual energy savings were confirmed using a calibrated whole-building energy model. Compared with the baseline, ASHRAE 36 control reduced HVAC energy consumption by 42 %, and RL-based control achieved a 54 % reduction. Furthermore, RL-based control reduced total HVAC energy consumption by 21 % more than ASHRAE 36 control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of computing-based automated fault detection and diagnosis of heating, ventilation and air conditioning systems

We report faults in Heating, Ventilation, and Air Conditioning (HVAC) systems of buildings result in significant energy waste in building operation. With fast-growing sensing data availability and advancement in computing, computational modeling has demonstrated strong capability to detect and diagnose HVAC system faults, hence, ensuring efficient building operation. This paper comprehensively reviews the state-of-the-art computing-based fault detection and diagnosis (FDD) for HVAC systems. Overall, the reviewed computing-based FDD methods are classified as two major approaches: knowledge-based and data-driven approaches. We then identify multiple important topics, including data availability, training data size, data quality, approach generality, capability, interpretability, and required modeling efforts, along with corresponding metrics to summarize the most updated FDD development. Generally, the knowledge-based approaches are further divided as physics-based modeling, Diagnostic Bayesian Network, and performance indicator-based methods while data-driven approaches include supervised learning, unsupervised learning, and regression and statistics-based methods. State-of-the-art FDD development, remaining challenges, and future research directions are further discussed to push forward FDD in practice. Availability of fault data, capability of existing methods to deal with complex fault situations (such as simultaneous faults), modeling interpretability for data-driven methods, and required engineering efforts for physics-based methods are identified as remaining challenges in FDD development. Improving modeling fidelity and reducing modeling efforts are essential for applying physics-based methods in real buildings. Meanwhile, addressing fault data availability, increasing algorithm adaptability, and handling multiple faults are essential to further enhance the applicability of data-driven FDD approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets of Faults in Variable Air Volume Terminal Units in a Multi-Zone Commercial Building

Faults in HVAC systems can decrease system efficiency and equipment lifespan, leading to 5%–30% of energy consumption being wasted in commercial buildings. We identified two common faults in HVAC variable air volume systems: a stuck damper fault in the variable air volume terminal unit and a discharge airflow sensor fault. We conducted three sets of damper stuck tests and two sets of airflow sensor tests, each including a fault-free scenario and scenarios with varying levels of faults, over one day. The faults were implemented in Oak Ridge National Laboratory’s two-story Flexible Research Platform building to generate a high-quality, well-controlled dataset covering fault-induced and fault-free scenarios. The test building, fault test scenarios, and data validation are described here. The open-source dataset includes 1 min intervals of weather and building data on the presence and absence of building faults. This dataset can be used to analyze the effects of HVAC system faults on system operation and indoor building conditions, and to develop or evaluate a fault detection and diagnosis algorithm.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coloured low-emissivity films for building envelopes for year-round energy savings

We report that buildings are responsible for over 40% of total US energy use, of which about 40% is directly related to the operation of heating, ventilation and air-conditioning (HVAC) systems. Saving energy to heat and cool buildings would contribute substantially to sustainability. Here we propose a category of coloured low-emissivity films for building walls that constitute the main component of the building thermal envelope. We demonstrate high reflectance (~90%) in infrared wavelength range and selective reflectance in the visible light wavelength range for desired colours. These films can help minimize radiative heat exchange between the indoor and outdoor environments, thus saving energy for all-year cooling and heating while satisfying the required aesthetical effect. Simulations show that these films can help reduce heat gain and loss by up to 257.6 MJ per installation wall area annually. In the case of a typical midrise apartment building, the HVAC system can save up to 124.46 GJ (equal to 9.87% of the building’s HVAC energy consumption). By rough estimation, a global CO 2 emission reduction of 1.14 billion metric tons annually could be achieved. Our work provides insights for innovative energy-saving building envelope materials that can help achieve global carbon neutrality and sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗