Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hazard analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

WSF PISA example for SAFER pilot

On October 15, 2021, the Radioactive and Hazardous Waste Management Facility Manager declared a Potential Inadequacy in the Safety Analysis (PISA) due to a new information relating to an error discovered in calculation AB-WSF-20-002. Calculation AB-WSF-20-002 is used to determine source terms and heat release rates for vehicle and aircraft impacts with fuel fires involving TRU waste containers. The source term for an aircraft’s impact has different source terms factors (i.e., DR, ARF, RF, LPF) that are applied to multiple categories of drums impacted in the accident scenario based on the physical stresses of the aircraft impact and involvement in the subsequent fuel pool fire. The source terms of the multiple categories of affected drums are summed to determine the final source term for the accident scenario. Certain categories of affected drums are modeled to lose their lid, causing material to eject and burn unconfined on the ground. For these specific categories, a lower ARF value was incorrectly applied in AB-WSF-20-002 (i.e., an ARF value of 1E-3 was used instead of the DOE-STD-5506-2007 directed ARF value of 1E-2). For these categories, the ARF is applied to a relatively small number of low-activity drums (i.e., 17 drums at 2.9 PE-Ci each) compared to the total number of drums affected (i.e., 166 drums totaling 621.8 PE-Ci). Therefore, this error is not expected to significantly increase final dose for the accident scenario. No immediate actions or compensatory measures are required to maintain the facility in a safe condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sustainable recovery of critical metals from spent lithium-ion batteries through gluconic acid-based bioleaching: Techno-economic analysis, life cycle assessment and process optimization

Recycling spent lithium-ion batteries (LIB) could potentially bridge the ever increasing supply and demand gap for critical metals and simultaneously facilitate the management of hazardous battery waste. This study investigated the optimization of gluconic acid-based bioleaching technology through design of experiments (DOE), combined with techno-economic analysis (TEA), and life cycle assessment (LCA) with the aim of maximizing the net present value (NPV) and minimizing global warming impacts of the process. Biolixiviant containing predominantly gluconic acid produced by the genetically engineered (ΔpstS, P 112 :mgdh) Gluconobacter oxydans B58 through fermentation using non-recyclable paper as a growth substrate was used for the LIB leaching. At optimal bioleaching conditions of gluconic acid (160 mM), leaching time (2.5 h), reducing agent FeSO 4 to metal, i.e., cobalt (Co), nickel (Ni) and manganese (Mn), mole ratio (0.88), temperature (55 °C) and pulp density (2.5 %), the leaching efficiency was 87 % 72 %, 94 %, and 88 % for Co, Ni, Mn and lithium (Li), respectively. TEA analysis confirmed that bioleaching plant with an annual black mass processing capacity of 10,000 metric tons and plant life of 30 years would be economically viable with an NPV and profit margin of $136 million and 11 %, respectively. The predicted carbon footprint of gluconic acid-based bioleaching for recovering 1 kg of Co (13.2 kg of CO 2 eq.) is lower compared to that of most state-of-the-art leaching technologies. Moreover, gluconic acid-based bioleaching effectively recovered target metals when tested for different black mass chemistries.

Bioleaching↗

Cyber-Informed Engineering (CIE) Workbook: End-of-Train (EoT) / Head-of-Train (HoT) Communications

This workbook presents a vulnerability (CVE-2025-1727 ) found in train applications and guides a digital risk assessment and mitigation analysis and application of Cyber-Informed Engineering principles to mitigate the potential consequences and ultimately the hazard through the engineering discipline because of exploiting this vulnerability. Workshop participants are encouraged to use the workbook to capture insights and lessons learned. The workbook guides the participant to: • Understand the HE communication vulnerability • Map digital threats to physical consequences • Use bowtie analysis to illustrate both “security” and “engineering” barriers • Apply CIE principles to ensure that even if communications are compromised, the physical engineered system still behaves safely. • Produce an actionable set of engineered and infosec controls for implementation

42 - ENGINEERING↗

Regulatory Treatment of Low Frequency External Events under a Risk-Informed Performance-Based Licensing Pathway

Significant efforts are underway to develop and implement a risk-informed performance-based licensing framework for advanced reactors built on the establishment of an affirmative safety case. Such approaches offer the benefits of increased flexibility regarding key design and licensing decisions based on a detailed assessment and understanding of plant risk. These methods include the comprehensive analysis of scenarios that have historically been addressed through conservative and deterministic licensing analysis approaches, such as the evaluation of event sequences at frequencies of occurrence beyond the design basis. While the detailed analysis of low frequency events provides insights that can help justify alternative treatments to past conservatism, the findings are dependent on the quality and confidence associated with the analyses. The assessment of external hazards presents a unique challenge, as their potential frequency of occurrence, especially of large magnitude events, is inherently uncertain given the long return periods in question. The current project seeks to further explore the regulatory treatment of low frequency external events as part of a risk-informed performance-based framework. The goals are to identify the benefits and challenges of such approaches for advanced reactor vendors and to aid in the development of consistent and appropriate methodologies. As part of this effort, the current report summarizes initial project findings, with a focus on the evaluation of the seismic hazard. This includes an exploration of the implementation of a risk-informed performance-based approach through an example analysis. Based on the identified challenges associated with the probabilistic treatment of low frequency event sequences, additional performance-based methods were explored as complementary tools for demonstrating regulatory compliance. The report highlights key challenges and opportunities associated with the methods and outlines recommendations and future activities to assist with their implementation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty quantification and sensitivity analysis for SPERT III E-core reactivity measurement benchmarking

The Special Power Excursion Reactor Test (SPERT) III E-core experiment is important because it provides critical data on reactor behavior under significant reactivity insertions, which is essential for validating computer simulations and ensuring the safety of modern light water reactors. Its design similarities to contemporary reactors make it a valuable resource for understanding and mitigating extreme hazards in nuclear operations. The current study details the application of formal parametric uncertainty quantification and sensitivity analysis to a model of the SPERT-III E-core model for zero power reactivity benchmarking. Additionally, the reactivity impact from various modeling assumptions is quantified. Overall, an conservative estimate for an uncertainty in k$_{\text{eff}}$ of $\pm$1257 was observed. A less conservative, more realistic, uncertainty estimate of $\pm$1096 pcm can be justified by the potential for various parametric uncertainties to become negligible when sampled independently across the ~1400 pins in the core. The experimental results fall within both of these uncertainty bounds. Standardized regression coefficient as well as Sobol indices are used to identify the guide tube thicknesses as the primary contributors to the uncertainty in k$_{\text{eff}}$. Overall, this study provides information on how the uncertainties in input parameters and modeling methods impact simulated k$_{\text{eff}}$ values and can be used to aid model building efforts for future code validation with the SPERT-III E-core experiment.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Obesity is associated with biliary tract cancer mortality and incidence: A pooled analysis of 21 cohort studies in the Asia Cohort Consortium

Abstract Body fatness is considered a probable risk factor for biliary tract cancer (BTC), whereas cholelithiasis is an established factor. Nevertheless, although obesity is an established risk factor for cholelithiasis, previous studies of the association of body mass index (BMI) and BTC did not take the effect of cholelithiasis fully into account. To better understand the effect of BMI on BTC, we conducted a pooled analysis using population‐based cohort studies in Asians. In total, 905 530 subjects from 21 cohort studies participating in the Asia Cohort Consortium were included. BMI was categorized into four groups: underweight (<18.5 kg/m 2 ); normal (18.5‐22.9 kg/m 2 ); overweight (23‐24.9 kg/m 2 ); and obese (25+ kg/m 2 ). The association between BMI and BTC incidence and mortality was assessed using hazard ratios (HR) and 95% confidence intervals (CIs) by Cox regression models with shared frailty. Mediation analysis was used to decompose the association into a direct and an indirect (mediated) effect. Compared to normal BMI, high BMI was associated with BTC mortality (HR 1.19 [CI 1.02‐1.38] for males, HR 1.30 [1.14‐1.49] for females). Cholelithiasis had significant interaction with BMI on BTC risk. BMI was associated with BTC risk directly and through cholelithiasis in females, whereas the association was unclear in males. When cholelithiasis was present, BMI was not associated with BTC death in either males or females. BMI was associated with BTC death among females without cholelithiasis. This study suggests BMI is associated with BTC mortality in Asians. Cholelithiasis appears to contribute to the association; and moreover, obesity appears to increase BTC risk without cholelithiasis.

Oze, Isao↗

MACCS Theory Manual

This report describes the models of the MACCS computer code as presented in MACCS Version 3.10.0. The purpose of MACCS is to simulate the impact of severe accidents at nuclear power plants on the surrounding environment. MACCS has been developed by Sandia National Laboratories for the U.S. Nuclear Regulatory Commission. From a given release of radioactive material into the atmosphere, MACCS estimates the extent and magnitude of radiological contamination, offsite doses, protective actions, socioeconomic impacts and costs, and health effects. Since the weather at the time of an accident is not predictable, MACCS supports various sampling options to run a representative set of simulations to evaluate weather variability. MACCS simulates atmospheric transport with a straight-line Gaussian plume segment model. From the estimated air and ground concentrations, MACCS models dose projections through several dose exposure pathways. These exposures can be offset by protective actions during the emergency response and long-term recovery of the accident. MACCS users directly specify the evacuation and sheltering area, while other protective actions (e.g., relocation, farmland restrictions, decontamination) are based on user-specified dose or concentration limits. While protective actions help reduce dose accumulation, they also cause social and economic impacts. MACCS models the extent of displaced individuals and land contamination, and the cost of offsite property damage, economic disruptions, and various accident expenditures caused by protective actions. Finally, from the dose accumulation, MACCS estimates early and stochastic health effects according to dose-response models. The purpose of consequence analyses is to be able to understand and estimate the impact of nuclear accidents. Consequence analysis is an essential tool to inform determinations of adequate protection of the public, to understand nuclear power hazards, to measure the value of regulations, and to help us appreciate the importance of nuclear safety. As such, MACCS has a variety of regulatory uses including environmental analyses (10 CFR 51.53, 52.47), regulatory cost-benefit analyses, backfit analyses (10 CFR 50.109), consequence analysis studies such as SOARCA (NUREG-1935), Level 3 PRA studies, and risk-informing of emergency planning (10 CFR 50 App. E and 50.47). This report updates the previous MACCS theory manual (NUREG/CR-4691 Vol. 2; Chanin, Sprung, Ritchie, & Jow, 1990) and accompanies the MACCS User's Guide (SAND-2021-1588) that describes the use and input requirements of the graphical user interface of MACCS known as WinMACCS. The MACCS User's Guide is also a reference guide that describes data input file formats, describes various software components in the MACCS code suite, and provides a set of example tutorials for running WinMACCS. Also, soon to be published is a MACCS input parameter guidance report (NUREG/CR-7270) that provides technical bases for commonly used MACCS input values. This page left blank

97 MATHEMATICS AND COMPUTING↗

Validation of Stage N3 of the Eighth Edition AJCC Staging System for Nasopharyngeal Carcinoma

Objectives To validate stage nodal (N)3 of the 8th edition American Joint Committee on Cancer (AJCC) staging system for nasopharyngeal carcinoma (NPC). Methods This retrospective cohort study extracted NPC patients from the Surveillance, Epidemiology, and End Results database between 2004 and 2016. Pathologically confirmed patients with complete data of level IV, N3a, and N3b lymph node metastasis were investigated. The included patients were divided into level IV, N3a, and N3b groups. Five‐year overall survival (OS) and cancer‐specific survival (CSS) were compared among the three groups. Results A total of 693 patients were included: 285 (41.13%) patients in the level IV group, 124 (17.89%) patients in the N3a group, and 284 (40.98%) patients in the N3b group. The 5‐year OS (57.1%, 55.0%, and 55.2%) and CSS (64.4%, 63.5%, and 64.4%) were not different among the level IV, N3a, and N3b groups. Multivariate regression analysis revealed that N stage was not an independent prognostic factor for OS (hazard ratio [HR] = 1.03, 95% confidence interval [CI]: 0.91–1.17; P = .65) or CSS (HR = 1.03, 95% CI: 0.89–1.19; P = .70). Conclusion Stage N3 of the 8th edition AJCC staging system for NPC is reasonable. Level of Evidence III Laryngoscope , 131:535–540, 2021

Pan, Xin‐Bin↗

Identification of Hydrogen Rail Maintenance Facility Hazards

Maintenance facilities for hydrogen rail, the activities conducted within such facilities, and how these activities differ from ordinary rail or hydrogen vehicle maintenance are currently being considered for the hazards specific to hydrogen. By performing a hazard and operability study (HAZOP) on numerous potential maintenance and repair scenarios, select low, medium, and high risk hazards relevant to hydrogen rail systems in such environments have been identified. The analysis resulted in 79 unique HAZOP scenarios: one scenario in the high risk category, 43 in the medium risk category, and 35 in the low risk category. Notably, large accidental releases of hydrogen due to tank rupture, aberrant defueling processes, or relief device opening within a facility are important low likelihood consequences that should nevertheless be appropriately prevented and mitigated.

08 HYDROGEN↗

Mapping Rare Earths and Toxics in E-Waste via Hyperspectral Imaging and Machine Learning

Electronic waste (e-waste) presents a mounting challenge to environmental sustainability due to its complex composition, which includes high-value rare earth elements, hazardous organic compounds, and non-recyclable plastics. Accurate and scalable material classification is essential for enabling efficient resource recovery and safe recycling practices. This study introduces a confidence-aware classification pipeline that combines mid-infrared hyperspectral imaging (HSI), spectral angle mapping (SAM), and iterative machine learning to perform pixel-level material identification across e-waste devices. A curated spectral library encompassing artificial materials (e.g., plastic iron oxide, galvanized metals), minerals (e.g., allanite, hematite), and organic compounds (e.g., benzanthracene, toluene) was used to generate pseudo-labels, each assigned a confidence score based on SAM-derived spectral similarity. High-confidence samples from seven consumer electronics—digital cameras, keyboards, laptop fans, modems, motherboards, TV remotes, and speakers—were iteratively expanded and classified using models such as Support Vector Machine (SVM), Random Forest, Gradient Boosting Classifier, Partial Least Squares Discriminant Analysis (PLSDA) and Logistic Regression. The best-performing classifiers achieved macro F1 scores approaching 1.0. Results revealed widespread plastic content (dominated by plastic iron oxide), the presence of rare earth-bearing minerals like cerium-containing allanite, and pervasive detection of hazardous organics such as benzanthracene. Principal Component Analysis (PCA) visualizations and confusion matrices confirmed high separability and robust classification performance. This methodology enables precise, non-destructive, and scalable classification of heterogeneous e-waste streams. It supports automated, hazard-aware sorting in recycling workflows, facilitating selective recovery of critical materials and compliance with circular economy goals. The confidence-aware framework provides a foundation for real-time deployment in industrial settings, offering significant implications for smart e-recycling infrastructure and policy-driven material stewardship.

Circular economy↗

Hierarchical semi-Markov models with duration-aware dynamics for activity sequences

Residential electricity demand at granular scales is driven by what people do and for how long. Accurately forecasting this demand for applications like microgrid management and demand response therefore requires generative models for activities that can produce realistic daily activity sequences, capturing both the timing and duration of human behavior. This paper develops a generative model of human activity sequences using nationally representative time-use diaries at a 10-min resolution. We use this model to quantify which demographic factors are most critical for improving predictive performance. We propose a hierarchical semi-Markov framework that addresses two key modeling challenges. First, a time-inhomogeneous Markov router learns the patterns of “which activity comes next.” Second, a semi-Markov hazard component explicitly models activity durations, capturing “how long” activities realistically last. To ensure statistical stability when data are sparse, the model pools information across related demographic groups and time blocks. The entire framework is trained and evaluated using survey design weights to ensure our findings are representative of the U.S. population. On a held-out test set, we demonstrate that explicitly modeling durations with the hazard component provides a substantial and statistically significant improvement over purely Markovian models. Furthermore, our analysis reveals a clear hierarchy of demographic factors: Sex, Day-Type, and Household Size provide the largest predictive gains, while Region and Season, though important for energy calculations, contribute little to predicting the activity sequence itself. The result is an interpretable and robust generator of synthetic activity traces, providing a high-fidelity foundation for downstream energy systems modeling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Critical Infrastructure Decision-Making under Long-Term Climate Hazard Uncertainty: The Need for an Integrated, Multidisciplinary Approach

U.S. critical infrastructure assets are often designed to operate for decades, and yet long-term planning practices have historically ignored climate change. With the current pace of changing operational conditions and severe weather hazards, research is needed to improve our ability to translate complex, uncertain risk assessment data into actionable inputs to improve decision-making for infrastructure planning. Decisions made today need to explicitly account for climate change – the chronic stressors, the evolution of severe weather events, and the wide-ranging uncertainties. If done well, decision making with climate in mind will result in increased resilience and decreased impacts to our lives, economies, and national security. We present a three-tier approach to create the research products needed in this space: bringing together climate projection data, severe weather event modeling, asset-level impacts, and contextspecific decision constraints and requirements. At each step, it is crucial to capture uncertainties and to communicate those uncertainties to decision-makers. While many components of the necessary research are mature (i.e., climate projection data), there has been little effort to develop proven tools for long-term planning in this space. The combination of chronic and acute stressors, spatial and temporal uncertainties, and interdependencies among infrastructure sectors coalesce into a complex decision space. By applying known methods from decision science and data analysis, we can work to demonstrate the value of an interdisciplinary approach to climate-hazard decision making for longterm infrastructure planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2D Dam-Break Analysis of L Lake and PAR Pond Dams Using HEC-RAS

In 1991 a dam-break study was conducted for the high hazard dams located at L Lake and PAR Pond on the Savannah River Site. Two scenarios were considered, over topping from a Probable Maximum Flood (PMF), and a fair weather dam-break for either or both dams. Unfortunately, no inundation map was developed from the study. The purpose of this project was to redo the original dam-break study with improved data and methodology to generate Inundation maps to assist with emergency response and evacuation plans. The Hydrologic Engineering Center's River Analysis System (HEC-RAS) is a free to download river analysis modeling program developed by the US Army Corps of Engineers capable of 1D and 2D hydraulic calculations. Version 5.0.7 (released March 2019) was used for this project. Digital elevation models for the area were retrieved from the US Geological Survey database and converted to a .hdf file within the program. Then the 2D flood area was identified from the contours. Both L Lake and PAR Pond were inputted as 1D storage areas because DEM data does not contain elevation values under water bodies. An elevation vs volume curve was available for both storage areas. Initial elevations were set for both scenarios. Both dams are earthen dams. The Steel Creek dam at L Lake has 6 ft diameter conduit with an upper and lower sluice gate. PAR pond dam consist of a weir and sluice gate connected to an 8 x 8 ft channel. Both outlets were modeled with a pool elevation vs discharge curve. The steel creek dam sluice gates were assumed to be fully open in all cases. As in the previous study, the dams were set to breach when they were overtopped by 1.5 ft during PMF conditions (Figure 1). A fair weather breach was set to be due to a piping failure (Figure 1). In the dual dam break during fair weather conditions the PAR pond dam fails 3 hours after Steel Creek to achieve maximum flooding in the down stream reaches. Simulation was run 3 days for each case and with a 1 minute computational interval. Maximum flooding occurs under PMF conditions with the failure of both dams. PAR pond dam fails first 16 hours and 32 minutes after the start of the simulation with the Steel creek dam failing 6 minutes later. In all cases, the bridges and roads spanning Steel Creek and Lower Three Runs will be inundated and potentially washed away. The Burtons Ferry Highway south of the storage areas will be partially flooded during PMF failure, dual fair weather failure, and PAR pond failure under fair weather conditions.

54 ENVIRONMENTAL SCIENCES↗

Gene co-expression network analysis in zebrafish reveals chemical class specific modules

Zebrafish is a popular animal model used for high-throughput screening of chemical hazards, however, investigations of transcriptomic mechanisms of toxicity are still needed. Here, our goal was to identify genes and biological pathways that Aryl Hydrocarbon Receptor 2 (AHR2) Activators and flame retardant chemicals (FRCs) alter in developing zebrafish. Taking advantage of a compendium of phenotypically-anchored RNA sequencing data collected from 48-h post fertilization (hpf) zebrafish, we inferred a co-expression network that grouped genes based on their transcriptional response. Genes responding to the FRCs and AHR2 Activators localized to distinct regions of the network, with FRCs inducing a broader response related to neurobehavior. AHR2 Activators centered in one region related to chemical stress responses. We also discovered several highly co-expressed genes in this module, including cyp1a, and we subsequently show that these genes are definitively within the AHR2 signaling pathway. Systematic removal of the two chemical types from the data, and analysis of network changes identified neurogenesis associated with FRCs, and regulation of vascular development associated with both chemical classes. We also identified highly connected genes responding specifically to each class that are potential biomarkers of exposure. Overall, we created the first zebrafish chemical-specific gene co-expression network illuminating how chemicals alter the transcriptome relative to each other. In addition to our conclusions regarding FRCs and AHR2 Activators, our network can be leveraged by other studies investigating chemical mechanisms of toxicity.

59 BASIC BIOLOGICAL SCIENCES↗

Transcatheter Arterial Chemoembolization for Treatment-Naive Hepatocellular Carcinoma Has Different Treatment Effects Depending on Central or Peripheral Tumor Location

Introduction: The purpose of this study was to evaluate the treatment efficacy of transcatheter arterial chemoembolization (TACE) for treatment-naive hepatocellular carcinoma (HCC) according to tumor location and burden. Methods: Between 2010 and 2019, consecutive patients who underwent TACE as the first treatment were enrolled. Tumors were classified into two categories based on their location, as central or peripheral tumors. Tumors in the central zone, which is within 1 cm of the main trunk or the first branch of the portal vein, were classified as central tumors, while those located in the peripheral zone were classified as peripheral tumors. Patients were grouped according to the HCC location and up-to-7 criteria. Patients with central tumors were classified into the central arm and those with only peripheral tumors were classified into the peripheral arm. Patients within and beyond the up-to-7 criteria were classified into the up-to-7 in and up-to-7 out-groups, respectively. Local recurrence-free survival (LRFS) and progression-free survival (PFS) were compared per nodule (central tumor vs. peripheral tumor) and per patient (central arm vs. peripheral arm), respectively. The prognostic factors of LRFS and PFS were analyzed by univariate and multivariate analyses. Results: A total of 174 treatment-naive patients with 352 HCCs were retrospectively enrolled. Ninety-six patients and 130 lesions were selected by propensity score matching. Median LRFS was longer for peripheral tumors than central tumors (not reached vs. 3.3 months, p < 0.001). Median PFS was 17.1 months (8.3–24.9) in the peripheral arm and up-to-7 in, 7.0 months (3.3–12.7) in the peripheral arm and up-to-7 out, 8.4 months (4.0–12.6) in the central arm and up-to-7 in, and 3.0 months (1.2–4.9) in the central arm and up-to-7 out-groups. The peripheral arm and up-to-7 in-groups had significantly longer PFS than the other three groups (p = 0.013, p = 0.015, p < 0.001, respectively). Multivariate analysis confirmed that the central zone and central arm were associated with high adjusted hazard ratios for tumor recurrence or death (2.87, p < 0.001; 2.89, p < 0.001, respectively). Conclusion: Treatment-naive HCCs in the peripheral zone had a longer LRFS and PFS following TACE compared to those in the central zone.

Gastroenterology & Hepatology↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

FEED Study of CarbonCapture Inc DAC and CarbonCure Utilization Technologies Using United States Steel’s Gary Works Plant Waste Heat (Final Report)

The University of Illinois at Urbana-Champaign (UIUC) led this project to produce a front-end engineering design (FEED) study of an advanced Direct Air Capture and Utilization System (DACUS) system that can remove a minimum of 5,000 tonnes/yr net of carbon dioxide from air (based on cradle-to-gate LCA) and utilizing the CO 2 to produce low carbon intensity ready mix concrete. The designed system, if built, would be larger than any currently existing Direct Air Capture (DAC) collector in the U.S. Such carbon capture technologies are critical to meeting the goals of the DOE’s program to accelerate climate-critical technology. In addition to the power sector, industrial facilities for the manufacture of steel and cement/concrete are among the major sources of anthropogenic CO 2 . DAC is a promising new technology for reducing CO 2 , a potent greenhouse gas, in the atmosphere but is expensive, in part due to the energy required to adsorb and desorb captured CO 2 during cycles. By integrating CarbonCapture Inc. (CCI) DAC modules at United States Steel's Gary Works (USS) and utilizing the site's waste heat, energy, and location this project evaluates the feasibility of utilizing the captured CO 2 and the logistics of transportation. CarbonCapture Inc. has developed an innovative DAC system using novel adsorbents to cost-effectively capture CO 2 . The captured, liquified gas will be trucked to ready-mix concrete plants within the region, the closest of which is approximately 3.5 miles away, where CarbonCure will inject it into concrete during the mixing process at the facilities. The carbon dioxide reacts with concrete, mineralizing into calcium carbonate (CaCO 3 ), permanently locking the greenhouse gas into the matrix of the building material. This FEED study demonstrated a full CO 2 value chain for DACUS from industrial facilities. It also provided a means for Visage Energy Corp. (Visage) to assess the impact of this holistic approach on job creation, regional economic impact, and environmental justice. The project team also included Sargent & Lundy (S&L) to provide the constructability review and costing of the integration of the DAC with the steel plant. Ecotek Engineering USA, LLC designed the outside battery limit (OSBL) infrastructure to connect the DAC and the plant. Activities performed during the project included: (1) Project Management Plan; (2) Technology Maturation Plan (TMP); (3) Initial Workforce Readiness Plan; (4) Workforce Readiness Plan; (5) Front-End Engineering Design (FEED) Study; (6) Project Design Basis; (7) Hazards and Operability (HAZOP) Study; (8) Constructability Review; (9) Project Cost Assessment; (10) Logistics Analysis of CO 2 Transportation to the Utilization Site; (11) Business Case Analysis; (12) Life Cycle Analysis (LCA); (13) Environmental Health and Safety (EH&S) Analysis; (14) Environmental Justice Analysis; and (15) Economic Revitalization and Job Creation Outcomes Analysis. This report provides a summary of the outcomes and results of the project, which was performed between Oct. 1, 2022, through Sept. 30, 2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing the Limits of InSAR to Detect Crustal Displacement from Low-Magnitude Earthquakes through Deep Learning

Detecting surface deformation associated with low-magnitude (M w ≤ 5) seismicity using interferometric synthetic aperture radar (InSAR) is challenging due to the subtlety of the signal and the often challenging imaging environments. However, low-magnitude earthquakes are potential precursors to larger seismic events, and thus characterizing the crustal displacement associated with them is crucial for regional seismic hazard assessment. We combine InSAR time-series techniques with a Deep Learning (DL) autoencoder denoiser to detect the magnitude and extent of crustal deformation from the M w = 3.4 Gallina, New Mexico earthquake that occurred on 30 July 2020. Although InSAR alone cannot detect event-related deformation from such a low-magnitude seismic event, application of the DL method reveals maximum displacements as small as (±2.5 mm) in the vicinity of both the fault and earthquake epicenter without prior knowledge of the fault system. This finding improves small-scale displacement discernment with InSAR by an order of magnitude relative to previous studies. We additionally estimate best-fitting fault parameters associated with the observed deformation. The application of the DL technique unlocks the potential for low-magnitude earthquake studies, providing new insights into local fault geometries and potential risks from higher-magnitude earthquakes. This technique also permits low-magnitude event monitoring in areas where seismic networks are sparse, allowing for the possibility of global fault deformation monitoring.

58 GEOSCIENCES↗