Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Input”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Controlled Pyrolysis: A Robust Scalable Composite Recycling Technology

The reinforced composites industry is facing significant challenges in handling the scrap composite material from automobile manufacturing, the wind turbine industry, and others. The fibers in the material, whether they be carbon, glass, or other materials have commercial value if they can be recovered successfully. Successfully means the fibers are clean with no sizing or other binders and have adequate strength and physical properties that would allow them to be economically reprocessed into valuable product. The composites recycling project was an industry-collaborative effort to develop a composite recycling technology using controlled pyrolysis. Through the recycling of scrap and end-of-life (EOL) cured composite materials, this pilot study was intended to create a business case by realizing a cost-effective means for recycling EOL and production scrap composite materials, ultimately reducing the volume of composite materials destined for landfill. The project was led by the Institute for Advanced Composites Manufacturing Innovation (IACMI), the American Composites Manufacturers Association (ACMA), Oak Ridge National Laboratory (ORNL), Continental Structural Plastics (CSP) a Teijin Group Company, CHZ Technologies, and A. Schulman with support from Owens Corning, John Deere, General Electric (GE), Ashland LLC, and Plastics Europe (CEFIC). The team studied and tested CHZ Technologies’ controlled pyrolysis system, known as the Thermolyzer TM , which operates on a scalable basis to convert organic polymer materials into a clean synthesis gas and char containing the recoverable carbon and glass fiber reinforcement. The recoverable energy contained in the input polymers creates the synthesis gas that can be used to provide heat to the Thermolyzer TM primary reactor in a sustainable manner. That is, once the Thermolyzer TM is started with a small amount of external natural gas, the synthesis gas that is created from the polymers will continue to operate the burners so long as feedstock is supplied. The reinforcing fiber materials remaining in the solid phase char were separated and cleaned for re-use in other polymer systems based on the retained properties of the fibers. The study created reports (attached in the appendix) on the Mass and Energy Balances, syngas analytics, VOC assessment, yield analysis and other analytics necessary for a Techno-Economic Analysis (TEA) to quantify the economic impact of the recovery and sustainable re-use of the carbon and glass fibers. The process consisted of 4 steps: Selection of 4 samples of cured composite waste materials from project partners interested in materials recycling and recovering the reinforcing fibers for best case re-use. The materials included glass fiber (GF) polyester/vinyl ester automotive SMC from CSP, GF epoxy balsa/PVC foam wind blades from GE, carbon fiber (CF) epoxy wind blade laminated spar caps from GE, and GF/CF epoxy hybrid assembly from John Deere. Processing the waste composite samples into 1-2” shreds. Packaging the shredded composites into bulk sacks on international shipping pallets for shipment to KUG in Forst (Lausitz), Germany. Pyrolysis of the shredded composites under controlled conditions designed for each polymer system. Collecting samples of the gas and char for analysis. Shipping the char containing the CF/GF back to the US for the next steps of testing the fibers and developing protocols for sustainable re-use of the fibers in composite applications.

36 MATERIALS SCIENCE↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Thermodynamics and kinetics of precipitation and austenite reversion during aging of Ti-free grade 300 maraging steel manufactured by laser powder bed fusion (LPBF)

Austenite reversion and intermetallic precipitation are two key phase transformations in maraging steels which determine the strength and ductility. Usually, an optimum aging temperature/time is determined using trial and error approach with inputs from thermodynamic databases and a-posteriori microscopy/hardness evaluations. In this study, a thermo-kinetic model is developed to predict the precipitation and austenite reversion kinetics during various post-fabrication heat treatments in a Ti-free variant of grade 300 maraging steel manufactured using laser powder bed fusion. The thermo-kinetic model was based on the principles of Scheil solidification and the classical nucleation theory. The predictions from the thermo-kinetic model were verified using suitable microscopy techniques, and the results from the thermo-kinetic model agree well with the experimental measurements. Overall, results highlight the fact that an Integrated Computational Materials Engineering approach can be used to predict the precipitation and austenite reversion kinetics, and be used as an input for an efficient design of heat treatments for achieving optimum mechanical properties.

36 MATERIALS SCIENCE↗

A Methodology for Estimating the Energy and Moisture Budget of the Convective Boundary Layer Using Continuous Ground-Based Infrared Spectrometer Observations

Abstract Land–atmosphere interactions play a critical role in both the atmospheric water and energy cycles. Changes in soil moisture and vegetation alter the partitioning of surface water and energy fluxes, influencing diurnal evolution of the planetary boundary layer (PBL). The mixing-diagram framework has proven useful in understanding the evolution of the heat and moisture budget within the convective boundary layer (CBL). We demonstrate that observations from the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains site provide all of the needed inputs needed for the mixing-diagram framework, allowing us to quantify the impact from the surface fluxes, advection, radiative heating, encroachment, and entrainment on the evolution of the CBL. Profiles of temperature and humidity retrieved from the ground-based infrared spectrometer [Atmospheric Emitted Radiance Interferometer (AERI)] are a critical component in this analysis. Large-eddy simulation results demonstrate that mean mixed-layer values derived are shown to be critical to close the energy and moisture budgets. A novel approach demonstrated here is the use of network of AERIs and Doppler lidars to quantify the advective fluxes of heat and moisture. The framework enables the estimation of the entrainment fluxes as a residual, providing a way to observe the entrainment fluxes without using multiple lidar systems. The high temporal resolution of the AERI observations enables the morning, midday, and afternoon evolution of the CBL to be quantified. This work provides a new way to use observations in this framework to evaluate weather and climate models. Significance Statement The energy and moisture budget of the planetary boundary layer (PBL) is influenced by multiple sources, and accurately representing this evolution in numerical models is critical for weather forecasts and climate predictions. The mixing-diagram approach, driven by profiling observations as illustrated here, provides a powerful way to quantify the contributions from each of these sources. In particular, the energy and moisture mixed into the PBL from above the PBL can be determined accurately from ground-based remote sensors using this approach.

54 ENVIRONMENTAL SCIENCES↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultrafast Photoflash Synthesis of High-Entropy Oxide Nanoparticles

High-entropy metal oxides (HEOs) have recently received growing attention for broad energy conversion and storage applications due to their tunable properties. HEOs typically involve the combination of multiple metal cations in a single oxide lattice, thus bringing distinctive structures, controllable elemental composition, and tunable functional properties. Many synthesis methods for HEOs have been reported, such as solid-state reactions and carbon thermal shock methods. These methods frequently are energy-intensive or require relatively expensive heating equipment. In this work, we report an ultrafast photoflash synthesis method for HEO nanoparticles on diverse substrates. The energy input is provided by a commercial Xe photoflash unit, which triggers exothermic reactions to convert metal salt precursors to HEO nanoparticles within tens of milliseconds. The formation of HEO nanoparticles is attributed to the ultrafast heating (∼106 K/s) and cooling (∼105 K/s) rates of the photoflash and overall high temperature (>1000 K) during the ultrafast synthesis process. When the synthesized CoNiFeCrMn oxide (HEO) is tested as an oxygen evolution reaction electrocatalyst, it shows similar activity to similar materials prepared by other methods. We believe this photoflash synthesis provides a simple method for many others to synthesize diverse HEOs and explore their properties and potential applications.

exothermic reaction synthesis↗

Numerical Analysis of Liquid Metal MHD Flow and Heat Transfer for Open-Surface Li Divertor in FNSF

Within the ongoing U.S.-based program on the development of liquid metal plasma-facing components, numerical simulations and analyses are performed to address the feasibility of the open-surface Li divertor. In the previous scoping studies (Smolentsev, 2021), heat-removal capabilities of the divertor were assessed using a simplified flow model for a slug-type velocity profile and constant flow thickness. Here, new analyses take into account forces acting on the flowing Li layer. Three reduced-order mathematical models are applied under the conditions of the U.S. Fusion Nuclear Science Facility (FNSF) to access magnetohydrodynamic (MHD) flow development effects, velocity distribution, and surface waves: 1) fully developed MHD flow; 2) quasi-2-D developing MHD flow; and 3) multiphase MHD flow. The obtained results for MHD flows and the surface heat flux computed with the plasma code scrape-off layer plasma simulation for ITER (SOLPS-ITER) are then used as input data to compute the temperature distribution in the divertor by solving the convection–diffusion energy equation.

Smolentsev, Sergey↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Exchanger Design for Waste Heat Recovery using Additive Manufacturing

With anticipated increases in global energy use and their associated emissions, there are many efforts to improve the emissions and efficiency of many industrial processes through waste heat recovery (WHR). To maximize improvements, the heat exchangers in WHR power cycles must be designed and optimized for a given heat source. Meanwhile, additive manufacturing (AM) is a single part manufacturing technique that provides the opportunity to develop unique and complex heat exchanger designs. Consequently, this work centers on the modeling, design, optimization, and testing of AM shell and tube heat exchangers for WHR. Specifically, a modified one-dimensional (1+1-D) and three-dimensional (3-D) heat exchanger models were developed and validated, with the 1+1-D model serving as the basis for design optimization. After modifications to the design to allow for AM, heat exchanger geometry optimizations were completed, targeting increased effectiveness across a range of physical parameters. Of the designs considered, nine were additively manufactured using Ti5553, and then tested using an external heat source and working fluid. Experimentally, the nineteen-tube, zero-baffle heat exchanger displayed the best overall performance, with the effects of dimensional accuracy, surface roughness, and baffles in the other designs also indicated. Next, the experimental results were used as inputs for the 1+1-D model. Although the original model was able to predict fluid outlet temperatures within 5% differences, larger variations in the heat exchanger performance parameters, temperature differences, and pressure drop necessitated optimizing the pressure drop and heat transfer calculations within the model. Thus, the resulting improved model was able to predict the heat transfer rates, heat source temperature difference, and effectiveness within 15% differences, while showing improvements in the pressure drops and working fluid temperature differences. The improved model serves as the foundation for future work to improve the design and performance of AM heat exchangers.

Spickler, Bailey Ann↗

Freshwater Input and Vertical Mixing in the Canada Basin’s Seasonal Halocline: 1975 versus 2006–12

Abstract The Arctic seasonal halocline impacts the exchange of heat, energy, and nutrients between the surface and the deeper ocean, and it is changing in response to Arctic sea ice melt over the past several decades. Here, we assess seasonal halocline formation in 1975 and 2006–12 by comparing daily, May–September, salinity profiles collected in the Canada Basin under sea ice. We evaluate differences between the two time periods using a one-dimensional (1D) bulk model to quantify differences in freshwater input and vertical mixing. The 1D metrics indicate that two separate factors contribute similarly to stronger stratification in 2006–12 relative to 1975: 1) larger surface freshwater input and 2) less vertical mixing of that freshwater. The larger freshwater input is mainly important in August–September, consistent with a longer melt season in recent years. The reduced vertical mixing is mainly important from June until mid-August, when similar levels of freshwater input in 1975 and 2006–12 are mixed over a different depth range, resulting in different stratification. These results imply that decadal changes to ice–ocean dynamics, in addition to freshwater input, significantly contribute to the stronger seasonal stratification in 2006–12 relative to 1975. These findings highlight the need for near-surface process studies to elucidate the impact of lateral processes and ice–ocean momentum exchange on vertical mixing. Moreover, the results may provide insight for improving the representation of decadal changes to Arctic upper-ocean stratification in climate models that do not capture decadal changes to vertical mixing.

54 ENVIRONMENTAL SCIENCES↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio studies on structural and thermodynamic properties of magnetic Fe

The present work systematically investigates the total energy, phonon spectra, and thermodynamic properties of different polymorphs of pure Fe, i.e., FCC, BCC, and HCP, with the ab initio approach, considering various magnetic configurations. In general, the calculated energy vs. volume curves and phonon spectra agree well with previous calculations and the experimental data. In addition, their thermodynamic properties are estimated by the quasiharmonic approximation (QHA). Specifically, a superposition approach based on the latest Zentropy theory was utilized to predict magnetic transition temperatures and thermodynamic properties of pure Fe. With the ensemble of the partition function considering the multiplicity of each magnetic microstate, the current work successfully reproduced the Curie/Néel temperature and the Schottky anomaly of heat capacity in FCC, BCC, and HCP Fe purely based on the ab initio input, which exhibits good agreement with the experimental data and CALPHAD modeling.

36 MATERIALS SCIENCE↗

Modeling Spatial Heterogeneity in Surface Turbulent Heat Flux in the U.S. Southern Great Plains

Advances in numerical modeling of cloud dynamics are driving a need for improved land model prediction at convective storm scales. Here, satellite and ground-based vegetation remote sensing data were combined with land model experiments to more accurately characterize land surface spatial heterogeneity in the Community Land Model (CLM4.0). The new subgrid classification of plant functional types (PFT) and leaf area index (LAI) enables consistent comparison between models and ground-based flux measurements in the U.S. southern Great Plains. Errors in vegetation data sets (inferred from comparison between 250 m satellite and ground-based LAI), while large, had less impact on the simulated characteristics of spatial heterogeneity compared to errors in model representation of surface energy partitioning (between latent and sensible heat flux) and its relationship to LAI. Predicted spatial heterogeneity in surface energy partitioning was enhanced after replacing soil and stomatal resistance parameters with a new set that better predicts the observed relationship to LAI. These modifications increase the number of smaller (mesoscale) dry land patches having higher sensible heat flux. The parameter experiments suggest that vegetation state and processes (transpiration) act to broaden the size spectrum of surface heat flux heterogeneity, which can influence clouds and convective initiation. Moreover, improvements in vegetation input data and model parameters had partially compensating effects on surface flux heterogeneity, indicating the importance of evaluating input data and parameterizations together to improve prediction at higher spatial resolutions.

54 ENVIRONMENTAL SCIENCES↗

Decoupling of peeling and ballooning thresholds for pedestal stability and reduction in ELM frequency via enhanced turbulence with edge electron cyclotron heating in DIII-D

Abstract The edge localized mode (ELM) frequency ( f ELM ) decreased by 63% when electron cyclotron heating (ECH) deposition location is shifted from ρ = 0.4 to ρ = 0.8 in DIII-D discharges where the power ratio between neutral beam injection (NBI) and ECH ( P NBI / P ECH ) is kept at ∼1. The performance of the pedestal in the ECH heated case is compared with a pure NBI reference discharge while keeping the total input power constant. All these discharges are performed at balanced input torque conditions. Furthermore, in the pure NBI discharge a strong decoupling of the peeling–ballooning (PB) thresholds is observed. The PB decoupling is preserved when the ECH is deposited at ρ = 0.8 and P NBI / P ECH ∼ 1, while the thresholds manifest a closed stability boundary when the ECH is deposited at ρ = 0.4. The inter-ELM pedestal recovery time is considerably larger for the ECH at ρ = 0.8 case. Increased pedestal turbulence is observed in beam emission spectroscopy (BES), Doppler backscattering and magnetic diagnostics for the ECH at the ρ = 0.8 case. Strong growth of a TEM-like mode is observed in BES and the mode growth is correlated with the decrease in f ELM . In view of these observations, the increased pedestal turbulence seems to be the plausible reason behind the delayed pedestal recovery following an ELM event in the ECH at ρ = 0.8 case, and the preservation of PB decoupling through temperature pedestal profile widening. TRANSP interpretative simulations show that the ECH at the ρ = 0.8 case is more susceptible to ITG/TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Weatherization Assistant NEAT/MHEA

The software provides a measure selection technique indicating cost effective retrofit activities that can be applied to a home using a standard Savings to Investment Ratio (SIR). Users must provide an input file describing the characteristics of the home to be evaluated. The software takes the input data provided and calculates energy savings and cost savings predicted for a standard set of measures given the input parameters. The Weatherization Assistant computes estimates of pre-retrofit whole building space heating and cooling energy consumptions based on the house description data supplied by the user. The consumptions are computed using a monthly heating and cooling variable base degree-day method by algorithms similar to those developed for the CIRA program [LBL, 1982]. The building consumptions are needed in computing the energy savings from measures affecting the efficiencies of the heating and cooling equipment. Weatherization Assistant then computes the energy savings and costs for each individual measure applicable to the building described as if it were the only measure installed in the house. From these energy savings, a discounted dollar savings over the life of each measure is computed. The ratio of this dollar savings to the cost of installing the measure, the "savings-to-investment ratio" (SIR), is used in an initial ranking of the measures' effectiveness. The "interacted" savings and SIR of measures are then determined assuming the measures are added to the house collectively, in order of their ranking, e.g., the second ranked measure is installed in the house initially described by the user after having been modified by the first ranked measure. If this second-ranked measure's updated SIR is greater than a user-defined limit, the measure is left implemented, else it is removed so that the next measure's effectiveness is not dependent on it. The choice between two mutually exclusive measures (such as different levels of insulation) is made on the basis of their "net present value" (NPV), the difference of life-time savings and installation cost, rather than their SIR. This has been shown to be the more correct criterion on which to base the selection between two measures, both of which cannot be installed. The audit computes and reports to the user the energy savings, discounted dollar savings, installation cost, and SIR for each measure considered cost-effective. For those with SIR greater than the user-designated cutoff, a materials list gives the material name, type, and quantity required for installation of the measure. Weatherization Assistant permits entry of pre-retrofit billing data for gas or electrically heated homes or homes with electric air-conditioning. The user may then make the decision to have the savings of the measures adjusted to reflect the difference in billed consumption and that predicted by the program.

Gettings, Michael↗