Search NASASearch

SEARCH · Search NASA

Results for “High power induction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,514 records · Page 13

Adaptation of virtual synchronous generators to dynamic conditions in power grids

Virtual synchronous generators (VSGs) are widely adopted as grid-forming controls for inverter-based resources. However, when grid conditions vary significantly as characterized by changes in short-circuit ratio (SCR) and the reactance-to-resistance (X/R) ratio, fixed-gain designs and the commonly used P–Q decoupling assumption can become inaccurate. Such conditions can degrade transient power performance, leading to oscillations, prolonged settling, and overshoot, particularly in stiff-grid operating points. This paper quantifies how grid strength and impedance-dependent coupling affect the active–reactive power dynamics of a conventional VSG over a broad range of SCR and X/R values. An adaptive VSG tuning framework is then developed by combining (i) a coupling-explicit, impedance-parameterized state-space model to enable systematic controller synthesis, (ii) a full-state-feedback law designed via pole placement to meet prescribed damping and settling-time specifications, and (iii) a physics-informed neural network (PINN)–based online grid-impedance estimator that updates controller gains in real time as grid conditions vary. Offline simulations in MATLAB/Simulink and real-time validation on an OPAL-RT platform show that the proposed method preserves consistent damping and settling behavior with reduced overshoot across wide SCR and X/R ranges, compared with fixed-gain VSG baselines.

Adaptive control

Single battery power subsystems: On-line reconditioning

The effect of on-line reconditioning (deep discharge) on a single, Nickel-Hydrogen spacecraft battery in GEO and LEO is considered. A life cycle test was performed in both GEO and LEO to study the effect of reconditioning on the battery's end of discharge voltage (EODV). The results of these tests show that: LEO on-line reconditioning increased the EODV (by approximately 15 cycles to maximum EODV) and the EODV lasted for approximately 300 cycles, but GEO on-line reconditioning decreased the EODV slightly during the first six days and increases significantly after the seventh day. Based on the available data from the life cycle test, it has been concluded that a long life and stable voltage is realizable with the baseline architecture (single battery, single bus) without the need for reconditioning.

Tobias, R. F.

Exceedance Probabilities and Recurrence Intervals for Extended Power Outages in the United States

This report provides estimates of recurrence intervals and conditional exceedance probabilities for major power outages by U.S. region between 2015 and 2021. Additionally, we provide estimates for grid management, particularly outages caused by California’s public safety power shutoffs (PSPS), and for natural outages caused by major hurricanes. Outage recurrence intervals are the average number of years between outage events, and conditional exceedance probabilities are the likelihoods that a customer who experiences a major power outage will experience an outage exceeding a given duration. Major outage events are those that affect 10,000 or more customers, as defined by the U.S. Department of Energy’s (DOE’s) Electric Emergency Incident and Disturbance Report, called OE-417 (DOE 2020). These results can be applied to determine the likelihood of experiencing long-duration outages, which can be integrated into cost-benefit analyses of resilience solutions and broader energy resilience studies.

Ericson, Sean [National Renewable Energy Laborator

Applications Technology Satellites Battery and Power System Design

A summary of the ATS battery design which is onboard the Applications Technology Satellite (ATS) is provided. The 15 ampere hour nickel cadmium cells were manufactured by Gulton, 19 series connected cells per battery, and there are two batteries in each spacecraft. The operating design life was two years in a synchronous orbit, and a maximum depth of discharge of 50 percent. The design temperature for the batteries in the spacecraft was 0 to 25 C, and the charge control consisted of 1 volt versus temperature on a constant percentage voltage. Also, C/10 current limit, and a commandable trickle charge rate, using C/20 or C/60. The undervoltage was sent across a 9 cell and a 10 cell group, and it was set at one volt average per group on either group.

F E Ford

Power Lane County Electric Grid Handbook

In 2024, Lane Couty was selected to participate in the U.S. Department of Energy’s Energy to Community program. Through the program, National Laboratory researchers from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, and the National Laboratory of the Rockies provide three years of technical assistance to Lane County and their project partners: the Center for Rural Livelihoods, Springfield Utility Board, and Emerald People’s Utility District. The project, named Power Lane County, aims to improve local electric system affordability, reliability and resilience in the face of natural hazards and potentially rising loads. The Power Lane County Electric Grid Handbook establishes a foundational understanding of the energy landscape and electric grid in Lane County to inform community engagement, education, and analysis in future project phases. This document synthesizes public data and utility and stakeholder engagement, including utility interviews to give the reader a comprehensive view of the challenges facing Lane County's electric system and the opportunities to address them

Electricity

Development and Validation of Low-Cost, High-Reflectance Composite CSP Facets: SIPS Final Report

This work investigates the various challenges associated with developing heliostat structural composite facets using 1 mm glass mirrors. Such facets are desirable for Concentrating Solar Power because 1 mm glass mirrors provide an absolute increase in reflectivity of 2-3 % over the industry standard of 4 mm glass mirrors. Prototypes of paraboloid composite facets with 1 mm glass mirrors were constructed that have a root mean square slope error on the order of 2 mrad while achieving greater than 96% reflectivity. These facets were constructed using a low-quality aluminum mold and a bill of materials that show potential to achieve cost parity with existing 4 mm glass mirrors supported by structural steel. The facets produced were able to survive up to 50 mm hail ball impacts and were robust against accelerated environmental cycling designed to expose durability concerns. Further work is needed to develop a scalable and cost-effective manufacturing process with a similar bill of materials.

14 SOLAR ENERGY

An Analysis of Energy Needs and Seawater Extraction Approaches for the Integration of Primary Magnesium Production with Nuclear Power

The cost of primary magnesium production is highly dominated by the energy required to produce the metal. This, along with the current geographical concentration of its production, makes the magnesium price vulnerable as energy-production paradigms begin to rapidly change. In this work, four nuclear-integration pathways for the efficient supply of heat and electricity to magnesium production from a nuclear power plant are considered. A production route using electrified metallothermic reduction is compared to a nuclear-heat-integrated electrolytic pathway. It is shown that the latter can achieve significantly lower primary energy consumption, 261 MJ/kg Mg compared with 416 MJ/kg Mg. The electrolytic pathway can also reduce emissions down to around 2.1 kgCO2/kg Mg, compared to around 34 kgCO2/kg Mg in the Pidgeon process. Beyond energy and emissions, the four pathways considered are also compared to their ability to reduce locational dependence of the production plant and reduce process complexity. This work also highlights future advances in magnesium production with a potential scheme for the efficient extraction of magnesium from seawater with coproduction of desalinated water and the potential of demand-side response from magnesium electrolysis. This is the first work to consider the full integration of primary magnesium production using nuclear cogeneration, and it is hoped the study paves the way for the analysis of economic nuclear integration within metal extraction and manufacturing.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Nuclear Safety [Vol. 33, No. 4, October-December 1992]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 499 Technical Note: Nuclear Regulatory Commission’s Examination Question Bank System, C. L Jensen and N. L. Skinner; 506 Report on the Specialists’ Meeting on Passive and Active Safety Features of Liquid-Metal Fast Breeder Reactors Organized by the International Atomic Energy Agency at Oarai Engineering Centre of Power Reactor and Nuclear Development Corporation, Japan, November 5-7,1991, S. R. Paranjpe; ACCIDENT ANALYSIS: 514 A Review of Hydrogen Production During Melt/Water Interaction in LWRs, D. F. Fletcher, B. D. Turland, and S. P. A. Lawrence; 535 A Review of the U 3 0 8 -Al Reaction as a Potential Heat Source in Research and Test Reactor Accidents, J. L. Snelgrove; CONTROL AND INSTRUMENTATION: 543 Multilevel Interfaces for Power Plant Control Rooms II: A Preliminary Design Space, K. J. Vicente; DESIGN FEATURES: 549 Twenty-Second DOE/NRC Nuclear Air Cleaning and Treatment Conference, R. R. Bellamy, D. W. Moeller, and M. W. First; 562 Book Review: Safety Assessment of Unit 5 (WWER-440/W-213) of the Greifswald Nuclear Power Station, M. H. Fontana; WASTE AND SPENT FUEL MANAGEMENT: 576 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 586 Analysis of Corrective Actions Applied to Nuclear Power Plant Operations, A. E. Cross; 593 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 596 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; 609 Non-Commercial Power Operating Experience; 614 World Nuclear Performance, Compiled by M. D. Muhlheim; RECENT DEVELOPMENTS: 623 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 635 Reports, Standards, and Safety Guides, D. S. Queener; 639 Proposed Rule Changes as of June 30, 1992; ANNOUNCEMENTS: 513 Fourth International Conference on Nuclear Fuel Reprocessing and Waste Management RECOD '94; 585 International Topical Meeting on Advanced Reactors Safety; 622 International Workshop on Implementation of ALARA at Nuclear Power Plants; 648 Short Course on Nuclear Criticality Safety; 648 8th Topical Meeting on Problems in Reactor Physics MEPhi-VOLGA-93; 643 The Authors; 646 Reviewers of Nuclear Safety, Vol. 33

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Optoelectronic polymer memristors with dynamic control for power-efficient in-sensor edge computing

Abstract As the demand for edge platforms in artificial intelligence increases, including mobile devices and security applications, the surge in data influx into edge devices often triggers interference and suboptimal decision-making. There is a pressing need for solutions emphasizing low power consumption and cost-effectiveness. In-sensor computing systems employing memristors face challenges in optimizing energy efficiency and streamlining manufacturing due to the necessity for multiple physical processing components. Here, we introduce low-power organic optoelectronic memristors with synergistic optical and mV-level electrical tunable operation for a dynamic “control-on-demand” architecture. Integrating signal sensing, featuring, and processing within the same memristors enables the realization of each in-sensor analogue reservoir computing module, and minimizes circuit integration complexity. The system achieves 97.15% fingerprint recognition accuracy while maintaining a minimal reservoir size and ultra-low energy consumption. Furthermore, we leverage wafer-scale solution techniques and flexible substrates for optimal memristor fabrication. By centralizing core functionalities on the same in-sensor platform, we propose a resilient and adaptable framework for energy-efficient and economical edge computing.

Optics

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

From zonal to nodal capacity expansion planning: Spatial aggregation impacts on a realistic test-case

Solving power system capacity expansion planning (CEP) problems at realistic spatial resolutions is computationally challenging. Thus, a common practice is to solve CEP over zonal models with low spatial resolution rather than over full-scale nodal power networks. Due to improvements in solving large-scale stochastic mixed integer programs, these computational limitations are becoming less relevant, and the assumption that zonal models are realistic and useful approximations of nodal CEP is worth revisiting. Here, this work is the first to conduct a systematic computational study on the assumption that spatial aggregation can reasonably be used for ISO-scale CEP. By considering a realistic, large-scale test network based on the state of California with over 8000 buses, we find that well-designed small spatial aggregations can yield good approximations but that coarser zonal models may result in large distortions of investment decisions, e.g., capacity under-investment of up to 41% for the lowest resolution model considered.

24 POWER TRANSMISSION AND DISTRIBUTION

Machine Learning for Multipactor Susceptibility Prediction in Planar RF Gaps

Multipactor discharge is a nonlinear electron avalanche that limits the performance of high-power radio-frequency (RF) and vacuum electronic devices. Predicting multipactor susceptibility traditionally relies on Monte Carlo or particle-in-cell (PIC) simulations, which become computationally expensive for large parametric studies. In this work, we present a supervised machine-learning (ML) framework for prediction of multipactor susceptibility in a two-surface planar geometry. The models are trained using high-fidelity PIC simulation generated susceptibility data and learn the relationship between operational parameters, geometry, and material-dependent secondary electron emission properties. The proposed approach enables rapid reconstruction of susceptibility charts while preserving the physical structure of multipactor growth regions.

43 PARTICLE ACCELERATORS

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY