Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydrogen Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Modeling Approach for the Aluminum-clad Dry Storage Pilot using HFIR Fuel

To confirm that the dry storage of aluminum-clad research reactor spent nuclear fuel (ASNF) will remain within the safety envelope after applied drying schemes and that the resulting evolution of the gas space composition, temperature, and pressure conditions are understood, a dry storage pilot project is being established. The pilot will incorporate an instrumented lid for discrete interval or for on-demand gas composition and temperature monitoring of two DOE Standard Canisters (DSCs) loaded with three High Flux Isotope Reactor (HFIR) inner cores per DSC. Each DSC would be subjected to a separate alternative candidate drying scheme. Canisters will undergo 1 to 5 years of monitoring, including internal temperature and gas sampling to track pressure and composition changes. This report outlines the approach for modeling the ASNF-in-canister behavior in terms of evolving gas space conditions for the ASNF dry storage pilot using HFIR fuel. The ASNF has an adherent surface oxyhydroxide layer comprised of boehmite/bayerite that generates hydrogen when subjected to irradiation. Three-dimensional multi-physics computational fluid dynamics simulations will be executed to compute the thermal field within the DSC and provide inputs to a chemical model employed to compute pressure buildup as hydrogen is generated in the system. Implemented in Cantera, the chemical model solves gas phase and aluminum oxyhydroxide surface-mediated radiolysis reactions. Gas phase reactions are sourced from Wittman and Hanson (2015), whereas surface-mediated reactions are incorporated by fitting experimental data using an optimization algorithm (Abboud, 2023). Water radiolysis reactions from Wren and Ball (2001) are adopted with modifications as described in Abboud (2023c). Understanding the effect of the hydrogen buildup over time is important for long-term storage safety considerations. Modeling results will include the canister pressure, temperature, and composition evolution from the initial helium backfill with the addition of radiolytically-evolved chemical species (e.g., hydrogen and oxygen). The specific HFIR cores for the pilot program have not yet been selected, and the overall design is still in development. The CFD-chemical model used for this work will be based on prior models with necessary updates to allow for improved accuracy and efficiency. The experimental data obtained from the HFIR demonstration will be used to improve and validate the computational models to predict the ASNF-in-canister behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ground Test Stand Development for One-step Electrochemical Production of High-Pressure Oxygen

NASA designed a test rig, High-Pressure Oxygen Generation Assembly (HPOGA) to test a novel method of electrolysis as an alternative technology to the state-of-the-art Oxygen Generation Assembly (OGA) currently on the International Space Station (ISS). This approach involves utilizing a specialized electrolysis cell stack designed to both generate and compress high-pressure oxygen up to 3600 PSIG. The design eliminates the need for an external compressor and hydrogen separator, streamlining the oxygen generation process. HPOGA tests the viability of an electrolysis cell stack for extended life usage. Within the system, there are several key subsystems: nitrogen, high/low pressure oxygen, hydrogen, water recirculation, and water injection. The water injection subsystem supplies deionized (DI) water to a centralized reservoir for consumption. Subsequently, a water recirculation loop transfers the DI water across the cathode side of the electrolysis cell stack with constant flow rate. The result is a supply of hydrogen in the water loop and oxygen accumulation on the anode side of the cell stack. Hydrogen is evaporated out as part of the hydrogen sub-system which also measures hydrogen/oxygen concentration for safety. The oxygen subsystem is responsible for managing high pressure oxygen, O2 exhaust, and conducting hydrogen/oxygen concentration measurements. The nitrogen subsystem serves dual functions, purging the hydrogen/oxygen subsystems, and regulating pressure in both high/low-pressure O2 sections via pneumatic back pressure regulators. Various sensors monitor pressure, temperature, humidity, gas concentration and flow rate in each subsystem. This paper presents the design and testing of a comprehensive test stand, which serves to operate and functionally verify the performance of the electrolysis cell while offering valuable lessons learned.

electrolysis↗

Invisible Flame Imaging

Stennis Space Center uses more than one million gallons of liquid hydrogen per month in its rocket testing program. Firefighters responding to a hydrogen fire had to give the area "the broom test" to determine the presence and location of a fire. This technique has significant safety and accuracy shortfalls. Stennis then developed technology to visually assess the presence, location and extent of hydrogen fires. SafetyScan, LLC. is now manufacturing FIRESCAPE, the first affordable commercial product for invisible (or ashless) fire imaging based on the original technology, to aid firefighters in seeing the invisible flames from alcohol and hydrogen fires during the day and even through smoke. The hand-held device weighs five pounds, is used like a pair of binoculars and can run for up to two hours before recharging.

Source record↗

Innovative duo-recombination layer design for effective hydrogen crossover mitigation in advanced MEAs for PEM water electrolyzers

Hydrogen crossover in proton exchange membrane water electrolyzers (PEMWEs) poses a safety hazard, reduces the overall efficiency, and limits the operational differential pressure range. Here, in this study, a membrane electrode assembly (MEA) with innovative Pt duo-recombination layer (DRL) design is developed by the unique reactive spray deposition technology (RSDT). The novel design comprises two thin RLs integrated within the volume of the membrane and has a total Pt loading of only 0.04 mg Pt cm −2 . Long-term durability test for over 3000 h is performed with as-fabricated MEA at steady-state conditions typical for an industrial hydrogen production system. The results from the durability test show that the newly developed DRL design effectively suppresses the H2 crossover to below 0.5 vol%. Furthermore, comprehensive post-test characterization of the MEA is performed and potential failure mechanisms in the Pt RLs observed during the durability test are identified and discussed in detail for the first time.

08 HYDROGEN↗

Hydrogen Transportation and Distributed Energy Systems Risk and Feasibility Assessment for Airport Facilities - CRADA 555 (Abstract)

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support PDX in performing a risk assessment for several hydrogen deployment scenarios. It is intended that the deployment of hydrogen at PDX could serve several roles, including decarbonizing its bus fleet and building out a distributed energy system which could also be used to facilitate emergency operations. PDX’s initial plans concern replacing their current fleet of 28 busses with FCEBs. To do so, PDX will need to deploy the hydrogen systems needed to support the buses. This includes hydrogen storage, production, delivery, filling, compression, and maintenance. PDX also has long range plans to build a distributed energy system to support normal and resilient operations. This study will investigate the risks of each plan individually, and a combined plan which serves both. Additionally, PDX is in an area with the potential for high seismic activity, as such this work will also include a seismic risk assessment. A detailed risk assessment using PDX as a test case is necessary to ensure the deployment of large-scale hydrogen is successful and to understand the benefits or drawbacks in contrast to electric only technologies. Many technologies have been proposed that claim to utilize hydrogen for both transportation and distributed energy systems; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for PDX will be analyzed, a risk assessment will be performed on the hydrogen infrastructure and distributed energy system. These assessments will be useful for understanding how each of these technologies would perform as applied to a large public facility and public safety. The results of this CRADA, and an impact of the DOE funding, will evaluate hydrogen as a key fuel for PDX and will accelerate by several years availability of hydrogen, fuel cells, and other low-carbon technologies.

08 HYDROGEN↗

Hydrogen/Air Fuel Nozzle Emissions Experiments

The use of hydrogen combustion for aircraft gas turbine engines provides significant opportunities to reduce harmful exhaust emissions. Hydrogen has many advantages (no CO2 production, high reaction rates, high heating value, and future availability), along with some disadvantages (high current cost of production and storage, high volume per BTU, and an unknown safety profile when in wide use). One of the primary reasons for switching to hydrogen is the elimination of CO2 emissions. Also, with hydrogen, design challenges such as fuel coking in the fuel nozzle and particulate emissions are no longer an issue. However, because it takes place at high temperatures, hydrogen-air combustion can still produce significant levels of NOx emissions. Much of the current research into conventional hydrocarbon-fueled aircraft gas turbine combustors is focused on NOx reduction methods. The Zero CO2 Emission Technology (ZCET) hydrogen combustion project will focus on meeting the Office of Aerospace Technology goal 2 within pillar one for Global Civil Aviation reducing the emissions of future aircraft by a factor of 3 within 10 years and by a factor of 5 within 25 years. Recent advances in hydrocarbon-based gas turbine combustion components have expanded the horizons for fuel nozzle development. Both new fluid designs and manufacturing technologies have led to the development of fuel nozzles that significantly reduce aircraft emissions. The goal of the ZCET program is to mesh the current technology of Lean Direct Injection and rocket injectors to provide quick mixing, low emissions, and high-performance fuel nozzle designs. An experimental program is planned to investigate the fuel nozzle concepts in a flametube test rig. Currently, a hydrogen system is being installed in cell 23 at NASA Glenn Research Center's Research Combustion Laboratory. Testing will be conducted on a variety of fuel nozzle concepts up to combustion pressures of 350 psia and inlet air temperatures of 1200 F. Computational fluid dynamics calculations, with the Glenn developed National Combustor Code, are being performed to optimize the fuel nozzle designs.

Smith, Timothy D.↗

Simulation insights into wetting properties of hydrogen-brine-clay for hydrogen geo-storage

Hydrogen geo-storage is attracting substantial interdisciplinary interest as a cost-effective and sustainable option for medium- and long-term storage. Hydrogen can be stored underground in diverse formations, including aquifers, salt caverns, and depleted oil and gas reservoirs. The wetting dynamics of the hydrogen-brine-rock system are critical for assessing both structural and residual storage capacities, and ensuring containment safety. Through molecular dynamics simulations, we explore how varying concentrations of cushion gases (CO 2 or CH 4 ) influence the wetting properties of hydrogen-brine-clay systems under geological conditions (15 MPa and 333 K). We employed models of talc and the hydroxylated basal face of kaolinite (kaoOH) as clay substrates. Our findings reveal that the effect of cushion gases on hydrogen-brine-clay wettability is strongly dependent on the clay-brine interactions. Notably, CO 2 and CH 4 reduce the water wettability of talc in hydrogen-brine-talc systems, while exerting no influence on the wettability of hydrogen-brine-kaoOH systems. Detailed analysis of free energy of cavity formation near clay surfaces, clay-brine interfacial tensions, and the Willard-Chandler surface for gas-brine interfaces elucidate the molecular mechanisms underlying wettability changes. Our simulations identify empirical correlations between wetting properties and the average free energy required to perturb a flat interface when clay-brine interactions are less dominant. Here, our thorough thermodynamic analysis of rock-fluid and fluid-fluid interactions, aligning with key experimental observations, underscores the utility of simulated interfacial properties in refining contact angle measurements and predicting experimentally relevant properties. These insights significantly enhance the assessment of gas geo-storage potential. Prospectively, the approaches and findings obtained from this study could form a basis for more advanced multiscale simulations that consider a range of geological and operational variables, potentially guiding the development and improvement of geo-storage systems in general, with a particular focus on hydrogen storage.

25 ENERGY STORAGE↗

Use of helium in airships

Economic and safety factors are discussed in relation to a switch from hydrogen to helium in airships.

HELIUM↗

Tank 11H Low Temperature Aluminum Dissolution and Inhalation Dose Potential Analyses at Savannah River Site – 26018

Currently, there is approximately 34 million gallons of high-level radioactive tank waste in the Tank Farm at the Savannah River Site (SRS). The ultimate goal of operations at the Tank Farm is to remove the high level waste (HLW) from the tanks followed by stabilization of the waste through vitrification of the HLW into glass or grouting the decontaminated waste into saltstone. After bulk removal of the HLW consisting of sludge, saltcake, and supernatant, further efforts are made to reduce the residual waste present in the tank in order to declare preliminary cease waste removal (PCWR) signifying completion of HLW removal. These reduction efforts can include tank washing to remove soluble salts and radioisotopes and dissolution of solids including aluminum. Aluminum in the form of gibbsite and boehmite is relatively insoluble in water. Through addition of aqueous sodium hydroxide, the aluminum can be dissolved at mild temperatures. In order for the waste tank to meet closure mode requirements of the Concentration, Storage, and Transfer Facilities (CSTF), which includes the Tank Farm, Documented Safety Analysis (DSA), a component of the safety basis, the inhalation dose potential (IDP) and the radiolytic hydrogen generation rate of the stored waste must be demonstrated to be lower than their respective designated limits. These parameters are calculated from measured radiochemical analyses of isotopes that emit a high amount of radioactivity including Cs-137, Sr-90, Pu-238, Pu-239, Pu-240, Pu-241, Am-241, and Cm-244. Following the low temperature aluminum dissolution (LTAD) process, Tank 11H slurry samples were pulled from the tank and sent to Savannah River National Laboratory (SRNL) to measure the extent of aluminum dissolution, hydroxide concentration, densities of slurry and supernatant, weight percent solids analyses, and radionuclide activities. The analyses of the composite sample found that approximately 90% of the total aluminum in the slurry was dissolved, indicating successful reduction of the insoluble aluminum in the waste tank. Additionally, the weight percent insoluble solids (slurry basis) measurement of the composite sample was found to be approximately 1%, demonstrating that minimal solids still remain in the tank. Finally, the radiochemical analyses of the composite sample determined that the waste contents of the tank met the IDP and radiolytic hydrogen generation rate requirements of the CSTF DSA. These measurements have shown that the LTAD process in Tank 11H was successful in waste reduction efforts and a positive step towards declaring PCWR and tank closure at SRS.

Dekarske, John [Savannah River National Laboratory↗

Reducing the L-H transition power threshold in ITER-similar-shape DIII-D hydrogen plasmas

Recent dedicated DIII-D experiments in low-torque, ITER-similar-shape (ISS) hydrogen plasmas (at a plasma current I p ~ 1.5 MA and ITER-similar edge safety factor q 95 ~ 3.6) show that the L-H transition power threshold P LH can be reduced substantially (~30%) with L-mode helium admixtures n He /n e $\leqslant$ 25%. In the ensuing H-mode, helium ion fractions n He /n H remain below 25%. H-mode normalized pressure and confinement quality are only slightly affected by helium seeding, and Z eff $\leqslant$ 2.15 (including helium and carbon content). The plasmas investigated here are electron-heat dominated, with temperatures T e (0)/T i (0) $\geqslant$ 1 and edge heat flux ratio Q e /Q i (ρ = 0.95) ~ 1.2–1.5. Without mitigation, P LH is higher by a factor of 2–3 in comparison to similar ISS deuterium plasmas. ISS hydrogen plasmas with lower plasma current I p ~ 1 MA (increased edge safety factor q 95 ~ 5.1) exhibit a substantially lower power threshold. This plasma current dependence, also observed previously on ASDEX-U and in JET, is not accounted for by the commonly used 2008 ITPA multi-machine threshold scaling, but could potentially allow H-mode access at marginal heating power during the initial plasma current ramp-up. Attempts to reduce P LH with low-field- and high-field-side hydrogen pellet injection, using 1.7 mm diameter pellets, have not demonstrated a robust threshold reduction, in contrast to successful earlier experiments with larger 2.7 mm pellets. Finally, techniques for reducing P LH are very important for ITER, in particular for accessing H-mode in hydrogen plasmas during the Pre-Fusion Power Operation-1 (PFPO-1) campaign with marginal auxiliary heating power (20–30 MW of ECH).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helium Conservation by Diffusion Limited Purging of Liquid Hydrogen Tanks

Recently, the new 1.2-million-gallon liquid hydrogen (LH 2 ) storage tank at the Kennedy Space Center Launch Complex 39 was purged, replacing nitrogen with helium, using a piston purge process. This purging approach had been used on Space Shuttle External Tanks (ET) in the past, but not on one of the large LH 2 tanks. The result was a huge success, potentially saving more than 1 million cubic feet of helium and significant labor. To better understand this result, a diffusion-based purge model was developed. The model predictions accurately match the helium concentration data, providing understanding of the helium savings and suggesting how to better optimize the purging of this large tank for future operations. The model was then applied to the piston purging of the Space Shuttle ETs, showing that these purges were not optimal, but that the amount of wasted helium was not excessive and that additional helium might have been saved by small changes to the process. The Space Shuttle Program (SSP) has ended, but these results are applicable to the purging of future large cylindrical LH 2 tanks. Finally, data have been obtained on inerting the Space Launch System (SLS) Core Stage (CS) LH 2 tank, replacing hydrogen with helium after an aborted launch. This is a more complicated case, but the model predicts that substantial helium might be saved by modifying the current purging process.

Helium Conservation↗

Study of Hydrogen Fuel Cell Technology for Freight Rail Propulsion and Review of Relevant Industry Standards.

Alternatives to conventional diesel electric propulsion are currently of interest to rail operators. In the U.S., smaller railroads have implemented natural gas and other railroads are exploring hydrogen technology as a cleaner alternative to diesel. Diesel, battery, hydrogen fuel cell, or track electrification all have trade-offs for operations, economics, safety, and public acceptability. A framework to compare different technologies for specific applications is useful to optimize the desired results. Standards from the Association of American Railroads (AAR) and other industry best practices were reviewed for applicability with hydrogen fuel cell technology. Some technical gaps relate to the physical properties of hydrogen, such as embrittlement of metals, invisible flames, and low liquid temperatures. A reassessment of material selection, leak/flame detection, and thermal insulation methods is required. Hydrogen is less dense and diffuses more easily than natural gas, and liquid hydrogen is colder than liquefied natural gas. Different densities between natural gas and hydrogen require modifications to tank designs and flow rates. Leaked hydrogen will rise rather than pool on the ground like diesel, requiring a modification to the location of hydrogen tanks on rolling stock. Finally, the vibration and shock experienced in the rail environment is higher than light-duty vehicles and stationary applications for which current fuel cell technology has been developed, requiring a modification in tank design requirements and testing.

08 HYDROGEN↗

Mission safety evaluation report for STS-38, postflight edition

After several months delay due to Liquid Hydrogen (LH2) leaks in the External Tank (ET) 17 in LH2 umbilical disconnect, Atlantis was launched at 6:48 p.m. Eastern Standard Time on 15 Nov. 1990. Atlantis was cleared for launch after the replacement of the ET 17 in umbilical disconnect and a successful tanking test on 24 Oct. 1990. No technical concerns were encountered during the countdown. The end of the STS-38 mission was extended by one day because of high crosswinds at the primary landing site, Edwards Air Force Base (EAFB), Calif. On the next day, 20 Nov. 1990, the winds were too high for a safe landing at EAFB, and a decision was made to select the Shuttle Landing Facility (SLF) at the Kennedy Space Center (KSC) at the primary landing site. The deorbit burn was performed on orbit 79 of the STS-38 mission. Reentry and descent were effected with no problems. Postlanding inspection of Atlantis' exterior found little evidence of damage. There has been a concern about returning an Orbiter to KSC, because the last mission to do so experienced tire failure. Atlantis' tires and brakes were in excellent condition with no indication of excessive wear.

Hill, William C.↗

Large-scale Hydrogen Storage – Risk Assessment Seattle City Light and Port of Seattle [Abstract]

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL), and the Port of Seattle (Port) in performing a risk assessment of large-scale hydrogen storage. Risk assessment is often used to ensure that adequate measures are taken to protect workers and the public, the environment, infrastructure, and assets. A detailed risk assessment can also be used to direct funding and upgrades, to specific components and sub-systems in order to mitigate risks to the larger system. In this way risk assessments are often employed as a part of a larger risk management strategy, with the goal of minimizing the occurrence of hazards and to identify means to limit their consequences. Risk assessment is often used to engage and inform regulators, and to communicate how specific regulations are being met. However, it is important to note that the proposed work is not intended for SCL and the Port to use in order to gain regulatory acceptance for their proposed activities. The work performed as a part of this effort will be a preliminary risk assessment for early-stage component and system designs and should be considered research and development (R&D). As such, the proposed work will be performed to a quality level and design maturity consistent with R&D and is not considered appropriate for final safety analysis and regulatory compliance purposes. Previous and on-going work at SCL and the Port demonstrated the utility of deploying hydrogen systems at the Port. The deployment of hydrogen at the Port is a part of a larger vision of using hydrogen to address a range of issues for SCL and the Port. These include large-scale fueling of MD/HD vehicles, cargo-handling equipment (CHE), and harbor vessels to reduce emissions; support of adjacent LD vehicles; support of critical port operations during extreme events (i.e., resiliency); deferral of more capital- and time-intensive electrical distribution system upgrades while still supporting evolving port operations and decarbonization efforts; facilitating electrification by establishing energy storage as a grid resource, starting at strategic port locations; creation of a flexible market resource that can be used by SCL to generate revenue via arbitrage; support of planned future maritime operations that involve heavy use of hydrogen for ocean-going vessels; and future end-use applications involving natural gas pipeline hydrogen injection. Ultimately, the success of these activities is underpinned by the deployed storage capacity. Large-scale deployment of hydrogen systems will require hydrogen storage at a scale that has not been demonstrated. In addition, the ideal location for such multi-use systems is near the end user which will often necessitate deploying into urban and/or industrial areas. A detailed risk assessment using the Port as a test case is necessary to ensure the deployment of large-scale hydrogen is successful. Many technologies have been proposed for hydrogen storage; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for the Port will be analyzed, and a risk assessment for compressed hydrogen, liquified hydrogen, and Liquid Organic Hydrogen Carrier (LOHC) storage will be performed. These risk assessments will be useful for understanding how each of these technologies would perform in terms of facility and public safety. The operating states of the proposed hydrogen systems at the Port will be analyzed and incorporated into the storage risk assessment. Scalability will also be analyzed to understand how future port uses would affect the overall risk assessment. Finally, using the risk assessment as a tool to inform engagement and to gain stakeholder acceptance will be explored.

08 HYDROGEN↗

Establishing ZIF‐8 as a reference material for hydrogen cryoadsorption: An interlaboratory study

Abstract Hydrogen storage by cryoadsorption on porous materials has the advantages of low material cost, safety, fast kinetics, and high cyclic stability. The further development of this technology requires reliable data on the H 2 uptake of the adsorbents, however, even for activated carbons the values between different laboratories show sometimes large discrepancies. So far no reference material for hydrogen cryoadsorption is available. The metal‐organic framework ZIF‐8 is an ideal material possessing high thermal, chemical, and mechanical stability that reduces degradation during handling and activation. Here, we distributed ZIF‐8 pellets synthesized by extrusion to 9 laboratories equipped with 15 different experimental setups including gravimetric and volumetric analyzers. The gravimetric H 2 uptake of the pellets was measured at 77 K and up to 100 bar showing a high reproducibility between the different laboratories, with a small relative standard deviation of 3–4 % between pressures of 10–100 bar. The effect of operating variables like the amount of sample or analysis temperature was evaluated, remarking the calibration of devices and other correction procedures as the most significant deviation sources. Overall, the reproducible hydrogen cryoadsorption measurements indicate the robustness of the ZIF‐8 pellets, which we want to propose as a reference material.

08 HYDROGEN↗

Capture, storage, and re-use of liquid hydrogen boil-off for aviation and aerospace applications

Despite major interest in the use of liquid hydrogen as a fuel for aviation and aerospace sectors, loss of hydrogen through boil-off continues to be a hurdle as it causes financial loss, indirect greenhouse gas emissions, and safety concerns. Herein, we perform techno-economic analysis, calibrated with experimental measurements, to assess the use of sorbents to capture and condition hydrogen boil-off events in the range of 1.5 to 70 tonnes per day at launch sites and airports. We evaluate the direct delivery of captured boil-off to combustion engines and fuel cells, comparing against boil-off re-liquification and compression. Results indicate probable cost-effectiveness at delivered liquid hydrogen prices above 0.9 U.S. dollar ($) per kg H2 at airports, and above 10 $ per kg H2 at launch sites where 10% or more of hydrogen is lost to boil-off.

08 HYDROGEN↗

Hydrogen isotope analysis in W-tiles using fs-LIBS

Abstract Laser-Induced Breakdown Spectroscopy (LIBS) is a promising technology for in-situ analysis of Plasma-Facing Components in magnetic confinement fusion facilities. It is of major interest to monitor the hydrogen isotope retention i.e. tritium and deuterium over many operation hours to guarantee safety and availability of the future reactor. In our studies we use ultraviolet femtosecond laser pulses to analyze tungsten (W) tiles that were exposed to a deuterium plasma in the linear plasma device PSI-2, which mimics conditions at the first wall. A high-resolution spectrometer is used to detect the Balmer- $$\alpha$$ α transition of the surface from implanted hydrogen isotopes (H and D). We use Calibration Free CF-LIBS to quantify the amount of deuterium stored in W. This proof-of-principle study shows the applicability of femtosecond lasers for the detection of low deuterium concentration as present in first wall material of prevailing fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗