At least 235 records · Page 13

Prediction of plasma properties in mercury ion thrusters

A simplified theoretical model was developed which obtains to first order the plasma properties in the discharge chamber of a mercury ion thruster from basic thruster design and controllable operating parameters. The basic operation and design of ion thrusters is discussed, and the important processes which influence the plasma properties are described in terms of the design and control parameters. The conservation for mass, charge and energy were applied to the ion production region, which was defined as the region of the discharge chamber having as its outer boundary the surface of revolution of the innermost field line to intersect the anode. Mass conservation and the equations describing the various processes involved with mass addition and removal from the ion production region are satisfied by a Maxwellian electron density spatial distribution in that region.

Longhurst, G. R.↗

HILT - A heavy ion large area proportional counter telescope for solar and anomalous cosmic rays

The HILT sensor has been designed to measure heavy ion elemental abundances, energy spectra, and direction of incidence in the mass range from He to Fe and in the energy range 4 to 250 MeV/nucleon. With its large geometric factor of 60 sq cm sr the sensor is optimized to provide compositional and spectral measurements for low intensity cosmic rays (i.e. for small solar energetic particle events and for the anomalous component of cosmic rays). The instrument combines a large area ion drift chamber-proportional counter system with two arrays of 16 Li-drift solid state detectors and 16 CsI crystals. The multi dE/dx-E technique provides a low background mass and energy determination. The sensor also measures particle direction. Combining these measurements with the information on the spacecraft position and attitude in the low-altitude polar orbit, it will be possible to infer the ionic charge of the ions from the local cutoff of the Earth's magnetic field. The ionic charge in this energy range is of particular interest because it provides unique clues to the origin of these particles and has not been investigated systematically so far. Together with the other instruments on board SAMPEX (LEICA, MAST, and PET), a comprehensive measurement of the entire solar and anomalous particle population will be achieved.

Klecker, Berndt↗

Precision Oxygen Isotope Measurements of Two C-Rich Hydrated Interplanetary Dust Particles

Introduction: Chondritic-smooth IDPs (Interplanetary Dust Particles) are low porosity objects whose mineralogy is dominated by aqueous alteration products such as Mg-rich phyllosilicates (smectite and serpentine group) and Mg-Fe carbonate minerals. Their hydrated mineralogy combined with low atmospheric entry velocities have been used to infer an origin largely from asteroidal sources. Spectroscopic studies show that the types and abundance of organic matter in CS IDPs is similar to that in CP IDPs. Although CS IDPs show broad similarities to primitive carbonaceous chondrites, only a few particles have been directly linked to specific meteorite groups such as CM and CI chondrites based on the presence of diagnostic minerals. Many CS IDPs however, have carbon contents that greatly exceed that of known meteorite groups suggesting that they either may derive from comets or represent samples of more primitive parent bodies than do meteorites. It is now recognized that many large, dark primitive asteroids in the outer main belt, as well as some trans-Neptunian objects, show spectroscopic evidence for aqueous alteration products on their surfaces. Some CS IDPs exhibit large bulk D enrichments similar to those observed in the cometary CP IDPs. While hydrated minerals in comets have not been unambiguously identified to date, the presence of the smectite group mineral nontronite has been inferred from infrared spectra obtained from the ejecta from comet 9P/Tempel 1 during the Deep Impact mission. Recent observations of low temperature sulfide minerals in Stardust mission samples suggest that limited aqueous activity occurred on comet Wild-2. All of these observations, taken together, suggest that the high-carbon hydrated IDPs are abundant and important samples of primitive solar system objects not represented in meteorite collections. Oxygen isotopic compositions of chondrites reflect mixing between a 16O-rich reservoir and a 17O,18O-rich reservoir produced via mass-independent fractionation. The composition of the 16O-rich reservoir is well constrained but material representing the 17O,18O-rich end-member is rare. Self-shielding models predict that cometary water, presumed to represent this reservoir, should be enriched in 17O and 18O by greater than 200 per mille. The high-carbon hydrated IDPs may be among the best materials available to search for preserved "cometary" H2O signatures. In order to better understand the origin and evolution of these particles, we have obtained 10 hydrated interplanetary dust particles for coordinated mineralogical, isotopic and organic analyses. We have previously reported the results of mineralogical and O isotopic measurements of two hydrated IDPs; here we present results of O isotopic measurements of three additional IDPs. Samples and Methods: Three interplanetary dust particles (L2079C35, L2083D46 and L2083E46) were embedded in S and partially ultramicrotomed into approximately 70 nanometer sections for analysis via transmission electron microscopy (TEM). The remainders of the unsliced particles were removed from S and pressed into high purity Au foil that was cleaned with HF acid and annealed at 800 degrees Centigrade. The pressed IDPs were analyzed via electron microprobe analysis (EPMA) for quantitative bulk chemical analysis. After EPMA analysis, the IDPs were subjected to precision O isotope analysis with the UCLA Cameca IMS-1270 ion probe. A 20 kiloelectronvolt, 0.5 nanoangstrom Cs+ primary beam of approximately 15 micrometers diameter was used for each measurement. Small particles of San Carlos olivine and Burma spinel were pressed into the Au foil for use as standards to correct for instrumental mass fractionation. The detection system was configured for multicollection, with 16O measured on a Faraday cup, and 17O and 18O measured on electron multipliers (EMs). Individual analyses consisted of 15 cycles of 10 seconds per cycle. Additionally, two microtome thin sections were measured for H isotopic compositions with the JSC NanoSIMS 50L ion probe. An 8 picoangstrom, 16 kiloelectronvolt Cs plus primary beam was used. Measurements consisted of H, C, 12C, 16O, and 18O collected with EMs in multicollection. Terrestrial biotite and kerogen were used for isotopic standards. A significant challenge in O isotope measurement of hydrated minerals is the interference from 16OH at mass 17O. We ensured that the 17O and 16OH peaks were fully resolved by using a mass resolution of greater than 7000 and by careful analyses of San Carlos olivine, Burma spinel and chlorite hydrated mineral standards. The hydride was further suppressed with a cold finger attached to an LN2 dewar to trap volatiles in the sample chamber. All sputtered ions were counted (i.e. presputtering was not used); after applying background, yield and deadtime corrections, we performed a change-point analysis on our data via R in order to determine when the sample reached sputtering equilibrium; data points collected prior to the change point were excluded. Change-point analysis was also used to determine whether the IDP had completely sputtered. Results: Mineralogy. IDPs C35 and E46 exhibited hydrated mineralogies, Fe-Ni sulfide grains, nanoglobules and occasional enstatite grains distributed throughout a fine-grained Mg-Fe saponite matrix. C35 also contained breunnerite (Mg,Fe)CO3; solar flare tracks were observed in enstatite, indicating minimal atmospheric entry heating. The mineralogy of D46 is dominated by a large FeS grain with a minor component of adhering silicate material. D46 was strongly heated during atmorpheric entry as evidenced by a well-developed magnetite rim. EPMA analyses show that both C35 and E46 have high carbon contents of 20 weight percentage (approximately 6X CI). D46 contains approximately 6 wt.weight percentage C. A significant amount of the carbon is present as carbon nanoglobules. Results: Hydrogen isotopes: Although the bulk delta D values of both sections of L2079C35 were within error of SMOW (minus 33 plus or minus 19 per mille, 1 plus or minus 14 per mille 1 sigma), several delta D-rich hotspots were also identified, reaching 2000 per mille. As shown in Fig. 1, these hotspots are clearly associated with discrete carbonaceous inclusions that are akin to nanoglobules found in many meteorites and other IDPs. Oxygen Isotopes. Results of the oxygen isotope measurements are shown in Figure 1. The oxygen isotope composition for L2079C35 was delta 18O equals plus11.6 plus or minus 1.9per mille, delta 17O equals plus 7.9 plus or minus 1.9per mille (2 standard errors). The oxygen isotope composition for L2083D46 was delta 18O equals minus 8.1 plus or minus 1.9 per mille, delta 17O equals minus 6.4 plus or minus 3.1 per mille (2 standard errors). The oxygen isotope composition for L2083E46 was delta 18O equals plus 12.0 plus or minus 1.9 per mille, delta 17O equals plus 9.2 plus or minus 2.0 per mille (2 standard errors). Discussion: Despite mineralogical similarities to highly aqueously altered carbonaceous chondrites, the hydrated IDPs we analyzed have oxygen isotopic compositions that are distinct from matrix materials in the CI, CM, and CR chondrites. The IDPs plot along the Young-Russell line, with delta 17O values for C35 and E46 suggestive of interaction with a 16O-poor reservoir. However, we have thus far not observed evidence of extreme 16O-poor reservoirs expected from self-shielding models and observed in Acfer 094 simplectite. The high carbon contents of the IDPs also set them apart from known meteoritic samples. The lack of atmospheric entry heating effects are consistent with low encounter velocities and suggest either an asteroidal source, or a low inclination, low eccentricity cometary origin. Conclusions: The unusual oxygen isotopic compositions, high carbon contents, and the abundance of Drich nanoglobules, together, suggest that the high-carbon, hydrated IDPs are derived from a primitive source that is not yet represented in meteorite collections.

Snead, C. J.↗

Ion beam treatment of potential space materials at the NASA Lewis Research Center

Ion source systems in different configurations, have been used to generate unique morphologies for several NASA space applications. The discharge chamber of a 30 cm ion source was successfully used to texture potential space radiator materials for the purpose of obtaining values of thermal emittance greater than 0.85 at 700 and 900 K. High absorptance surfaces were obtained using ion beam seed texturing, for space radiator materials that were flown on the Long Duration Exposure Facility (LDEF) for 5.8 years in space. An ion source discharge chamber was also used to develop electrode surfaces with suppressed secondary electron emission characteristics for use in collectors in microwave amplifier traveling wave tubes. This was accomplished by sputtering textured carbon onto copper as well as texturing copper using tantalum and molybdenum as sacrificial texture inducing seeding materials. In a third configuration, a dual ion beam system was used to generate high transmittance diamondlike carbon (DLC) films.

Kussmaul, Michael↗

Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

near grid plasma↗

Engineering experimental program on the effects of near-space radiation on lithium doped solar cells

The results of an experimental evaluation of the real-time degradation characteristics of lithium-diffused silicon solar cells are reported. A strontium-90 radioisotope was used for simulation of a typical earth-orbital electron environment. The experiment was performed in an ion pump vacuum chamber with samples maintained at -50, +20, +50, and +80 C. Samples were illuminated during the 6-month exposure run with solar cell 1-5 characteristics measured periodically in situ. This 6-month exposure corresponded to a 1 MeV equivalent fluence of approximately 10 to the 14th power electrons/sq cm. Several types of lithium cells were irradiatied and compared directly with conventional N/P cells. The best lithium cells compared favorably with N/P cells, particularly at the higher test temperatures. With a slight improvement of initial performance characteristics, lithium cells appear feasible for 5 to 10 year missions at synchronous altitude. Based on the reported results and those of other irradiation experiments, lithium cells would appear to be superior to N/P cells in proton-dominated earth-orbital environments. Another important conclusion of the effort was that illuminated/loaded cells degrade more rapidly than do dark/unloaded cells. The irradiation experiment provided data of high quality with a high degree of confidence because of the experimental and statistical analysis techniques utilized.

Source record↗

A computer controlled mass spectrometer system for investigating the decomposition of non-metallic materials under atmospheric conditions

A PDP 11/23 quadrupole mass spectrometer system was coupled to a nondiscriminating gas inlet system permitting gases at atmospheric pressure to be admitted into a high vacuum chamber containing the ion source of the mass spectrometer without separation of the gaseous components. The resolution of related software problems has resulted in a convenient computer-mass spectrometer system capable of generating masses, relative intensities and related data on the gaseous products resulting from the atmospheric thermal decomposition of nonmetallic materials.

Thompson, J. M.↗

The Advanced Energetic Pair Telescope (AdEPT}: A Future Medium-Energy Gamma-Ray Balloon (and Explorer?) Mission

Gamma-ray astrophysics probes the highest energy, exotic phenomena in astrophysics. In the medium-energy regime, 0.1-200 MeV, many astrophysical objects exhibit unique and transitory behavior such as the transition from electron dominated to hadron dominated processes, spectral breaks, bursts, and flares. Medium-energy gamma-ray imaging however, continues to be a major challenge particularly because of high background, low effective area, and low source intensities. The sensitivity and angular resolution required to address these challenges requires a leap in technology. The Advance Energetic Pair Telescope (AdEPT) being developed at GSFC is designed to image gamma rays above 5 MeV via pair production with angular resolution of 1-10 deg. In addition AdEPT will, for the first time, provide high polarization sensitivity in this energy range. This performance is achieved by reducing the effective area in favor of enhanced angular resolution through the use of a low-density gaseous conversion medium. AdEPT is based on the Three-Dimensional Track Imager (3-DTI) technology that combines a large volume Negative Ion Time Projection Chamber (NITPC) with 2-D Micro-Well Detector (MWD) readout. I will review the major science topics addressable with medium-energy gamma-rays and discuss the current status of the AdEPT technology, a proposed balloon instrument, and the design of a future satellite mission.

Hunter, Stanley D.↗

The interaction of O(plus) ions with the interior surface of a copper chamber

Modulated beams of 0(+), Ar(+), and Kr(+) in the 100-300 eV range are directed into a copper box simulating the ante-chamber of an orbiting mass spectrometer. An RF quadrupole mass spectrometer and phase sensitive detection extract the component of the internal mass spectrum correlated with the beam. Intense Ar and Kr signals are observed; however, no O or O2 is detectable, indicating loss of the primary O(+) beam to surface interactions. All four primary ions stimulate sizeable signals at masses 26 and 28. The relevance of these experiments to the interpretation of mass spectra obtained by orbiting satellites is discussed.

Siegel, M. W.↗

Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber

This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision electric gate for time-of-flight ion mass spectrometers

A time-of-flight mass spectrometer having a chamber with electrodes to generate an electric field in the chamber and electric gating for allowing ions with a predetermined mass and velocity into the electric field. The design uses a row of very thin parallel aligned wires that are pulsed in sequence so the ion can pass through the gap of two parallel plates, which are biased to prevent passage of the ion. This design by itself can provide a high mass resolution capability and a very precise start pulse for an ion mass spectrometer. Furthermore, the ion will only pass through the chamber if it is within a wire diameter of the first wire when it is pulsed and has the right speed so it is near all other wires when they are pulsed.

Sittler, Edward C.↗

Multi-Thruster Propulsion Apparatus

An electric propulsion machine includes an ion thruster having a discharge chamber housing a large surface area anode. The ion thruster includes flat annular ion optics with a small span to gap ratio. Optionally, at least a second thruster may be disposed radially offset from the ion thruster.

Patterson, Michael J.↗

X-Ray Photoelectron Spectroscopy

The interaction of photon and the electron goes back to the early part of 19th century emanating from the photo-electric effect depicted by none other than Albert Einstein (Ref 1) described in 1905, and the redistribution of kinetic energy resulting from the interaction of x-ray and solids reported during early part of the century (Ref.2). The spectrum resolutions obtained at that time was not sufficient to observe distinct peaks in spectra for materials. Thus, these phenomena hardly attracted any attention for many years following these discoveries. The modern X-ray Photoelectron Spectroscopy (XPS) has been possible by the extensive and significant contribution from Kai Siegbahn and others (Ref.3, 4) of Uppsala University. Siegbahn developed and employed a high-resolution electron spectrometer that revealed electron peaks in a spectrum emerging from the interaction of x-rays and solids. Eventually, Kai Siegbahn received Nobel Prize in 1981 for his contributions to XPS. Around 1958, shifts in elemental peaks were realized in compounds when the same elements are bound to other but different elements. This discovery resulted in the chemical state identification in various chemicals as well as the oxidation states of atoms in compounds. Because of these useful physical effects, the Uppsala group named XPS with a synonymous name of ESCA (Electron Spectroscopy for Chemical Analysis) used widely today and will be used here alternatively. Therefore, XPS or ESCA not only identifies the element, but also the compound these elements form, from their chemical shifts. Compared to other micro-analytical techniques such as Energy Dispersive (EDS) or Wavelength Dispersive (WDS) techniques, XPS analyzes only few atomic layers present on the surface. This was discovered early in 1966 (Ref. 5). While this has awarded a merit to the analytical technique to analyze very thin layers such as films and coatings, it often analyzes the adsorbed superficial gases and contaminations on a sample introduced to its analytical chamber. This necessitates the surface is cleaned and the underlying material, material of interest, is exposed in a clean environment such that the material of interest is analyzed. The cleaning is accomplished by a scanning ion gun within the analytical chamber of the instrument. Ion gun uses an argon gas and is commonly attached in most modern machines. Reliable and efficient vacuum systems employed in modern machines does not allow adsorbed layers to rebuild after the surface is cleaned. Development of efficient and reliable vacuum pumps over these developmental years is yet another important step in the commercialization of XPS machines. Vacuum levels of better than 10-7 torr are essential to increase the mean free path of electrons released from the sample surface. Thus, modern machines are equipped with high capacity ion, turbo or cryogenic pumps in their analytical chambers. Today, XPS has advanced from an applied physics laboratory to industry for use in quality control as well as analysis of contaminants and has taken a dominant role in microanalysis. Its uniqueness arises from the fact that it is considered non-destructive compared to other common micro-analytical techniques using the electron and ion excitation sources. Polymers and plastics could be analyzed since the binding energies of saturated and unsaturated bonds in atoms could be separated. Extremely thin layers could be analyzed including materials with layered structures. The technique, though did not advance for many years, has now opened a new window for research as well as applications in industry due to its ability to separate and measure the chemical shifts in bound elements. Principles

Panda, Binayak↗

Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole

An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.

Argonne Tandem Linac Accelerator System↗

Advanced electric propulsion and space plasma contactor research

A series of experiments performed on an 8 cm dia. ring cusp magnetic field ion thruster are described. The results show the effects of anode and cathode position and size, ring cusp axial location and discharge chamber length on plasma ion energy cost and extracted ion fraction. Thruster performance is shown to be improved substantially when optimum values of these parameters are used. Investigations into the basic plasma phenomena associated with the process of plasma contacting are described. The results show the process of electron collection from a background plasma to a hollow cathode plasma contactor exhibits a higher impedance than the process of electron emission from the hollow cathode. The importance of having cold ions present to facilitate the plasma contacting process is shown. Results of experiments into the behavior of hollow cathodes operating at high interelectrode pressures (up to approx. 100 Torr) on nitrogen and ammonia are presented. They suggest that diffuse emission from the insert of a hollow cathode can be sustained at high interelectrode pressures if the cathode is made of non-conducting material and the cathode internal pressure is reduced by evacuating the cathode interior. A theoretical model of discharge chamber operation developed for inert gas thrusters is extended so it can be used to evaluste the performance of mercury ion thrusters. Predictions of the model are compared to experimental results obtained on two 30 cm dia. thrusters.

Wilbur, P. J.↗

NASA Tech Briefs, November 2006

Topics include: Simulator for Testing Spacecraft Separation Devices; Apparatus for Hot Impact Testing of Material Specimens; Instrument for Aircraft-Icing and Cloud-Physics Measurements; Advances in Measurement of Skin Friction in Airflow; Improved Apparatus for Testing Monoball Bearings; High-Speed Laser Scanner Maps a Surface in Three Dimensions; Electro-Optical Imaging Fourier-Transform Spectrometer; Infrared Instrument for Detecting Hydrogen Fires; Modified Coaxial Probe Feeds for Layered Antennas; Detecting Negative Obstacles by Use of Radar; Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators; PixelLearn; New Software for Predicting Charging of Spacecraft; Conversion Between Osculating and Mean Orbital Elements; Generating a 2D Representation of a Complex Data Structure; Making Activated Carbon by Wet Pressurized Pyrolysis; Composite Solid Electrolyte Containing Li+- Conducting Fibers; Electrically Conductive Anodized Aluminum Surfaces; Rapid-Chill Cryogenic Coaxial Direct-Acting Solenoid Valve; Variable-Tension-Cord Suspension/Vibration- Isolation System; Techniques for Connecting Superconducting Thin Films; Versatile Friction Stir Welding/Friction Plug Welding System; Thermal Spore Exposure Vessels; Enumerating Spore-Forming Bacteria Airborne with Particles; Miniature Oxidizer Ionizer for a Fuel Cell; Miniature Ion-Array Spectrometer; Promoted-Combustion Chamber with Induction Heating Coil; Miniature Ion-Mobility Spectrometer; Mixed-Salt/Ester Electrolytes for Low-Temperature Li+ Cells; Miniature Free-Space Electrostatic Ion Thrusters; Miniature Bipolar Electrostatic Ion Thruster; Holographic Plossl Retroreflectors; Miniature Electrostatic Ion Thruster With Magnet; Using Apex To Construct CPM-GOMS Models; Sequence Detection for PPM Optical Communication With ISI; Algorithm for Rapid Searching Among Star-Catalog Entries; Expectation-Based Control of Noise and Chaos; Radio Heating of Lunar Soil to Release Gases; Using Electrostriction to Manipulate Ullage in Microgravity; Equations for Scoring Rules When Data Are Missing; Insulating Material for Next-Generation Spacecraft; and Pseudorandom Switching for Adding Radar to the AFF Sensor.

Source record↗

An experimental investigation of cusped magnetic field discharge chambers

Several features of a proposed model of ion thruster performance are tested experimentally. The experiment conducted demonstrates the effects of variation in thruster operating parameters on the average plasma ion energy costs and extracted ion fractions of various ring and line cusp discharge chambers. The results indicate that the model correctly predicts the variation in the plasma ion energy cost resulting from changes in: propellant gas, grid transparency to neutral atoms, beam extraction area, and discharge voltage. In addition, the model is shown to be applicable to both ring and line cusp designs. Measurements of the extracted ion fraction indicate that this parameter tends to increase with decreasing discharge voltage and is generally higher for operation with argon as opposed to krypton propellant. Results suggest that to use the proposed thruster performance model as an aid in thruster design the performance may be described in terms of four thruster configuration dependent constants and two operating parameters.

Brophy, J. R.↗