Effects of low-fluence helium plasma exposure characterized by helium ion microscopy scanning probes and in-situ ellipsometry.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Blending, or mixing, processes in 1.3 million gallon nuclear waste tanks are complicated by the fact that miles of serpentine, vertical, cooling coils are installed in the tanks. As a step toward investigating blending interference due to coils in this type of tank, a 1/10.85 scale tank and pump model were constructed for pilot scale testing. A series of tests were performed in this scaled tank by adding blue dye to visualize blending, and by adding acid or base tracers to solution to quantify the time required to effectively blend the tank contents. The acid and base tests were monitored with pH probes, which were located in the pilot scale tank to ensure that representative samples were obtained. Using the probes, the hydronium ion concentration [H{sup +}] was measured to ensure that a uniform concentration was obtained throughout the tank. As a result of pilot scale testing, a significantly improved understanding of mixing, or blending, in nuclear waste tanks has been achieved. Evaluation of test data showed that cooling coils in the waste tank model increased pilot scale blending times by 200% in the recommended operating range, compared to previous theoretical estimates of a 10-50% increase. Below the planned operating range, pilot scale blending times were increased by as much as 700% in a tank with coils installed. One pump, rather than two or more, was shown to effectively blend the tank contents, and dual pump nozzles installed parallel to the tank wall were shown to provide optimal blending. In short, experimental results varied significantly from expectations.
Water and ion dynamics in concentrated LiCl solutions were studied using ultrafast 2D IR spectroscopy with the methyl thiocyanate (MeSCN) CN stretch as the vibrational probe. The IR absorption spectrum of MeSCN has two peaks, one peak for water associated with the nitrogen lone pair of MeSCN (W) and the other peak corresponding to Li + associated with the lone pair (L). To extract the spectral diffusion (structural dynamics) of W and L species, we developed a method that isolates the peak of interest by subtracting the 2D Gaussian proxies of multiple interfering peaks. Center line slope data (normalized frequency–frequency correlation function) for 2D bands from the W and L are fit with triexponential functions. The fastest component (1.1–1.6 ps) is assigned to local hydrogen bond length fluctuations. The intermediate timescale (~4.0 ps) corresponds to the hydrogen bond network rearrangement. The slowest component decays in ~40 ps and corresponds to ion pair and ion cluster dynamics. The very similar W and L spectral diffusion indicates that the motions of the water and ions are strongly coupled. Orientational relaxations of the W and L species were extracted using a new method to eliminate the effects of overlapping peaks. The results show that MeSCN bound to water undergoes orientational relaxation significantly faster than MeSCN bound to Li + . The orientational and spectral diffusion results are compared. In conclusion, a Stark coupling model is used to extract the root mean square average electric field caused by the ion clouds along the CN moiety as a function of concentration.
Several in situ probes have been designed and implemented into the diagnostic array of the C-2 field-reversed configuration (FRC) at Tri Alpha Energy [M. Tuszewski et al. (the TAE Team), Phys. Rev. Lett. 108, 255008 (2012)]. The probes are all variations on the traditional Langmuir probe. They include linear arrays of triple probes, linear arrays of single-tipped swept probes, a multi-faced Gundestrup probe, and an ion-sensitive probe. The probes vary from 5 to 7 mm diameter in size to minimize plasma perturbations. They also have boron nitride outer casings that prevent unwanted electrical breakdown and reduce the introduction of impurities. The probes are mounted on motorized linear-actuators allowing for programmatic scans of the various plasma parameters over the course of several shots. Each probe has a custom set of electronics that allows for measurement of the desired signals. High frequency ( > 5MHz) analog optical-isolators ensure that plasma parameters can be measured at sub-microsecond time scales while providing electrical isolation between machine and data acquisition systems. With these probes time-resolved plasma parameters (temperature, density, spatial potential, flow, and electric field) can be directly/locally measured in the FRC jet and edge/scrape-off layer.
Magnetite has been analysed using Field Ion Microscopy (FIM) and Atom Probe Tomography (APT), highly attractive techniques for the nanoanalysis of geological materials despite the difficulties inherent in analyzing semiconducting and insulating materials. Additional information is contained in the original extended abstract.
The ion current onto a spherical or cylindrical probe is analyzed in the cold-ion approximation with allowance for ionization and collisions with neutrals. An expression for the ion density that takes into account both ionization and collision in the finite-size perturbed region is derived. The current-voltage characteristics for the dimensionless parameters r{sub p}/{lambda}{sub D} = 0.0001-10, {lambda}{sub i}/{lambda}{sub D} = 0.01 - {infinity}, and z{lambda}{sub D}/(kT{sub e}/M){sup 1/2} = 0-5 are determined by numerically solving Poisson's equation, and the corresponding approximate expressions are obtained.
Triggered ion-acoustic waves are a pair of coupled waves observed in the previously unexplored plasma regime near the Sun. They may be capable of producing important effects on the solar wind. Because this wave mode has not been observed or studied previously and it is not fully understood, the issue of whether it has a natural origin or is an instrumental artifact can be raised. This paper discusses this issue by examining 13 features of the data such as whether the triggered ion-acoustic waves are electrostatic, whether they are both narrowband, whether they satisfy the requirement that the electric field is parallel to the k-vector, whether the phase difference between the electric field and the density fluctuations is 90°, whether the two waves have the same phase velocity as they must if they are coupled, whether the phase velocity is that of an ion-acoustic wave, whether they are associated with other parameters such as electron heating, whether the electric field instrument otherwise performed as expected, etc. The conclusion reached from these analyses is that triggered ion-acoustic waves are highly likely to have a natural origin although the possibility that they are artifacts unrelated to processes occurring in the natural plasma cannot be eliminated. This inability to absolutely rule out artifacts as the source of a measured result is a characteristic of all measurements.
Solar photoelectric power ion propelled probe of asteroid region, describing design and mission planning
A mobile luminescent probe has been developed to detect fast ion losses and suprathermal ions escaping from the plasma of the TJ-II stellarator device. The priorities for its design have been flexibility for probe positioning, ease of maintenance, and detector sensitivity. It employs a coherent fiber bundle to relay, to the outside of the vacuum chamber, ionoluminescence images produced by the ions that impinge, after entering the detector head through a pinhole aperture, onto a screen of luminescent material. Ionoluminescence light detection is accomplished by a charge-coupled device camera and by a photomultiplier, both of which are optically coupled to the in-vacuum fiber bundle head by means of a standard optical setup. A detailed description of the detector, and the first results obtained when operated close to the plasma edge, are reported.
Nanostructuring has been proved effective towards improving many energy storage and conversion devices, and is feasible for a wide range of materials. In particular, secondary nanoarchitectured materials exhibit collective advantages compared with nano-sized primary building blocks. Despite the manifold efforts in designed nanoarchitectures and synthetic routes, the underlying ion diffusion kinetics and phase transformation behaviours within nanoarchitectures still remain less explored. Herein, we probed enhanced lithium-ion transport behaviours using 2D holey zinc ferrite (ZFO) nanosheets as a model material, to demonstrate how self-assembled 2D holey nanoarchitectured electrodes can feature efficient ion diffusion channels, robust yet continuous electron transfer framework, and enlarged surface area, contributing to the superior performance over the ZFO nanoparticles without secondary structures. By revealing kinetic parameters through combined spectroscopic measurements and electrochemical techniques, our study manifests increased lithium-ion diffusion coefficients, higher capacitive charge storage contribution and reduced charge transfer impedance in holey nanosheets compared to randomly aggregated nanoparticles. Furthermore, our results promote deeper understanding of significantly enhanced electrochemical energy storage properties of these 2D holey nanoarchitectured electrodes resulted from more uniform and complete phase transformation and better active material utilization.
The performance of many diagnostic and control systems within fusion and other fields of research are often detrimentally affected by spurious noise signals. This is particularly true for those (such as radiation or particle detectors) working with very small signals. Common sources of radiated and conducted noise in experimental fusion environments include the plasma itself and instrumentation. The noise complicates data analysis, as illustrated by noise on signals measured with the heavy ion beam probe (HIBP) installed on the Madison Symmetric Torus. The noise is time-varying and often exceeds the secondary ion beam current (in contrast with previous applications). Analysis of the noise identifies the dominant source as photoelectric emission from the detectors induced by ultraviolet light from the plasma. This has led to the development of a calibrated subtraction technique, which largely removes the undesired temporal noise signals from data. The advantages of the technique for small signal measurement applications are demonstrated through improvements realized on HIBP fluctuation measurements.
Not Available
Evaluation of ion density and plasma potential from Langmuir probe data - graphs
Diagnostic probe for low density plasma beam ion velocity distribution measurement in steady state and pulsed plasma exhausts
This introductory tutorial describes the technique of atom probe tomography for materials characterization at the atomic level. The evolution of the technique from the initial atom probe field ion microscope to today's state-of-the-art three dimensional atom probe is outlined. An introduction is presented on the basic physics behind the technique, the operation of the instrument, and the reconstruction of the three-dimensional data. The common methods for analyzing the three-dimensional atom probe data, including atom maps, isoconcentration surfaces, proximity histograms, maximum separation methods, and concentration frequency distributions, are described.
To probe the origin of p-type conductivity in Sb-doped ZnO, a careful and detailed synchrotron radiation study was performed. The extended X-ray absorption fine structure and X-ray photoelectron spectroscopy investigations provided the evidence for the formation of the complex defects comprising substitution Sb ions at Zn sites (Sb{sub Zn}) and Zn vacancies within the Sb-doped ZnO lattice. Such complex defects result in the increases of Sb-O coordination number and the Sb valence and thereby lead to the p-type conductivity of Sb-doped ZnO. The back-gate field-effect-transistors based on single nanorod of Sb-doped ZnO were constructed, and the stable p-type conduction behavior was confirmed.
Magnetospheric compression due to impact of enhanced solar wind dynamic pressure P dyn has long been considered as one of the generation mechanisms of electromagnetic ion cyclotron (EMIC) waves. Here, with the Van Allen Probe-A observations, we identify three EMIC wave events that are triggered by P dyn enhancements under prolonged northward interplanetary magnetic field (IMF) quiet time preconditions. They are in contrast to one another in a few aspects. Event 1 occurs in the middle of continuously increasing P dyn while Van Allen Probe-A is located outside the plasmapause at postmidnight and near the equator (magnetic latitude (MLAT) ~ -3°). Event 2 occurs by a sharp P dyn pulse impact while Van Allen Probe-A is located inside the plasmapause in the dawn sector and rather away from the equator (MLAT ~ 12°). Event 3 is characterized by amplification of a preexisting EMIC wave by a sharp P dyn pulse impact while Van Allen Probe-A is located outside the plasmapause at noon and rather away from the equator (MLAT ~ -15°). These three events represent various situations where EMIC waves can be triggered by P dyn increases. Several common features are also found among the three events. (i) The strongest wave is found just above the He + gyrofrequency. (ii) The waves are nearly linearly polarized with a rather oblique propagation direction (~28° to ~39° on average). (iii) The proton fluxes increase in immediate response to the P dyn impact, most significantly in tens of keV energy, corresponding to the proton resonant energy. (iv) The temperature anisotropy with T ⊥ > T || is seen in the resonant energy for all the events, although its increase by the P dyn impact is not necessarily always significant. Finally, the last two points (iii) and (iv) may imply that in addition to the temperature anisotropy, the increase of the resonant protons must have played a critical role in triggering the EMIC waves by the enhanced P dyn impact.
14YWT oxide dispersion strengthened (ODS) ferritic steel was irradiated with of 5 MeV Ni2+ ions, at 300 °C, 450 °C, and 600 °C to a damage level of 100 dpa. The stability of Ti–Y–O nanoclusters was investigated by applying atom probe tomography (APT) in voltage mode, of the samples before and after irradiations. The average size and number density of the nanoclusters was determined using the maximum separation method. These techniques allowed for the imaging of nanoclusters to sizes well below the resolution limit of conventional transmission electron microscopy techniques. The most significant changes were observed for samples irradiated at 300 °C where the size (average Guinier radius) and number density of nanoclusters were observed to decrease from 1.1 nm to 0.8 nm and 12 × 1023 to 3.6 × 1023, respectively. In this study, the nanoclusters are more stable at higher temperature.