Search NASA⌕ Search

SEARCH · Search NASA

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Laboratory Astrophysics at NASA Ames: Recent Results and Advances

The Cosmic SImulation Chamber (COSmIC) facility was developed at NASA Ames to study, in the laboratory, neutral and ionized molecules and nanoparticles under the low temperature and high vacuum conditions representative of interstellar, circumstellar and planetary environments. COSmIC is composed of a Pulsed Discharge Nozzle expansion that generates a plasma in a free supersonic jet expansion coupled to highsensitivity, complementary in situ diagnostic tools, used for the detection and characterization of the species present in the expansion: a Cavity Ring Down Spectroscopy and fluorescence spectroscopy systems operating in the UV-Visible range, and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS). We will present recent advances that were achieved in laboratory astrophysics using COSmIC. These include advances in the domain of the diffuse interstellar bands (DIBs) and in the formation of dust grains and aerosols from their gas-phase molecular precursors in environments as varied as circumstellar outflows and planetary atmospheres. An extension of the spectral response of the facility into the infrared (IR) range is in progress with the addition of a high-resolution near-IR to mid-IR CRDS system that will allow to further investigate cosmic molecules and grains with COSmIC. Acquisition of laser induced fluorescence spectra of cosmic molecule analogs and the laser induced incandescence spectra of cosmic grain analogs are also planned. Preliminary results in these fronts will presented and the implications of the on-going studies for astronomy will be addressed.

Laboratory↗

Progressing -190 °C to +500 °C Durable SiC JFET ICs From MSI to LSI

This invited paper describes prototype SiC JFET integrated circuit (IC) and packaging technology that has produced arguably the most harsh-environment durable electronics ever demonstrated. Prototype medium-scale integration (MSI) ICs fabricated by NASA Glenn Research Center have successfully operated for over 1 year in 500 °C air-ambient, over 60 days in 460 °C and 9.3 MPa pressure caustic Venus surface environment test chamber, from -190 °C to +812 °C, and radiation exposure through 7 MRad(Si) total ionizing dose and 86 MeV-cm2/mg heavy ion strikes. Recent on-going work focused on upscaling this “go anywhere” IC capability from MSI to large-scale integration (LSI) prototype via benchmark memory ICs is described.

Integrated Circuits↗

Graphic Three-Axes Presentation of Residual Gas Analyzer Data

Residual gas analyzers (RGA) are commonly used to measure the composition of residual gases in thermal-vacuum test chambers. Measurements from RGA's are often used to identify and quantify outgassing contaminants from a test article during thermal-vacuum testing. RGA data is typically displayed as snapshots in time, showing instantaneous concentrations of ions from ionized residual gas molecules at different atomic masses. This ion concentration information can be interpreted to be representative of the composition of the residual gas in the chamber at the instant of analysis. Typically, test personnel are most interested in tracking the time history of changes in the composition of chamber residual gas to determine the relative cleanliness and the clean-up rate of the test article under vacuum. However, displays of instantaneous RGA data cannot provide test personnel with the preferred time history information. In order to gain an understanding of gas composition trends, a series of plots of individual data snapshots must be analyzed. This analysis is cumbersome and still does not provide a very satisfactory view of residual gas composition trends. A method was devised by the authors to present RCA data in a three-axis format, plotting Atomic Mass Unit (AMU), the Ionization Signal Response (ISR) as amps/torr as a function of AMU, and Time, to provide a clear graphic visualization of trends of changes in ISR with respect to time and AMU (representative of residual gas composition). This graphic visualization method provides a valuable analytical tool to interpret test article outgassing rates during thermal vacuum tests. Raw RGA data was extracted from a series of delimited ASCII files and then converted to a data array in a spreadsheet. Consequently, using the 3-D plotting functionality provided by the spreadsheet program, 3-D plots were produced. After devising the data format conversion process, the authors began developing a program to provide real-time 3-D plotting of RGA data. The intent of this program is to automate the RGA data acquisition process and to generate up-to-the-minute time history 3-D displays of stored RGA data (development of this program was not complete at the time of this writing). This paper provides a brief description of the data format conversion process and presents results from a recent test to illustrate the usefulness of this 3-D RGA data plotting technique.

Johnson, Kenneth R.↗

DBD Plasma Actuators for Flow Control in Air Vehicles and Jet Engines - Simulation of Flight Conditions in Test Chambers by Density Matching

Dielectric Barrier Discharge (DBD) Plasma actuators for active flow control in aircraft and jet engines need to be tested in the laboratory to characterize their performance at flight operating conditions. DBD plasma actuators generate a wall-jet electronically by creating weakly ionized plasma, therefore their performance is affected by gas discharge properties, which, in turn, depend on the pressure and temperature at the actuator placement location. Characterization of actuators is initially performed in a laboratory chamber without external flow. The pressure and temperature at the actuator flight operation conditions need to be simultaneously set in the chamber. A simplified approach is desired. It is assumed that the plasma discharge depends only on the gas density, while other temperature effects are assumed to be negligible. Therefore, tests can be performed at room temperature with chamber pressure set to yield the same density as in operating flight conditions. The needed chamber pressures are shown for altitude flight of an air vehicle and for jet engines at sea-level takeoff and altitude cruise conditions. Atmospheric flight conditions are calculated from standard atmosphere with and without shock waves. The engine data was obtained from four generic engine models; 300-, 150-, and 50-passenger (PAX) aircraft engines, and a military jet-fighter engine. The static and total pressure, temperature, and density distributions along the engine were calculated for sea-level takeoff and for altitude cruise conditions. The corresponding chamber pressures needed to test the actuators were calculated. The results show that, to simulate engine component flows at in-flight conditions, plasma actuator should be tested over a wide range of pressures. For the four model engines the range is from 12.4 to 0.03 atm, depending on the placement of the actuator in the engine. For example, if a DBD plasma actuator is to be placed at the compressor exit of a 300 PAX engine, it has to be tested at 12.4 atm for takeoff, and 6 atm for cruise conditions. If it is to be placed at the low-pressure turbine, it has to be tested at 0.5 and 0.2 atm, respectively. These results have implications for the feasibility and design of DBD plasma actuators for jet engine flow control applications. In addition, the distributions of unit Reynolds number, Mach number, and velocity along the engine are provided. The engine models are non-proprietary and this information can be used for evaluation of other types of actuators and for other purposes.

Ashpis, David E.↗

Electron avalanche in liquid xenon

Measurements in liquid Xe are reported of the characteristic function that describes the avalanche, the first Townsend coefficient. An electron avalanche occurs when the drifting electrons attain sufficient kinetic energy from the electric field to cause additional ionization. Data on the avalanche were obtained by studying the pulses in a liquid-filled proportional chamber as a function of applied voltage and anode diameter. The results of the investigation show that the avalanche of free electrons in purified liquid Xe is adequately described by the same formalism used for the avalanche of electrons in gases.

Derenzo, S. E.↗

Production of a large, quiescent, magnetized plasma

An experimental device is described which produces a large homogeneous quiescent magnetized plasma. In this device, the plasma is created in an evacuated brass cylinder by ionizing collisions between electrons emitted from a large-diameter electron gun and argon atoms in the chamber. Typical experimentally measured values of the electron temperature and density are presented which were obtained with a glass-insulated planar Langmuir probe. It is noted that the present device facilitates the study of phenomena such as waves and diffusion in magnetized plasmas.

Landt, D. L.↗

Results from the UCSD magnetic monopole search

The energy loss mechanism for slowly moving magnetic monopoles in helium provides a means of extending the search for such particles by ionization techniques to velocities approximately 3 X 1 million cm/sec (beta approximately equals 0.0001). Other gases (e.g., CH2 or CO2) mixed with helium will be ionized with high efficiency by collisions with excited helium atoms, thus allowing the use of large proportional chamber systems for the detection of the monopoles. The first reported results utilizing this mechanism was the experiment of Kajino, et al., using a detector with an area-solid angle product alpha time delta alpha of 24.7 square meters sr. They set a limit on the flux of monopoles of 7.2 x 10 to the 13th power cm(-2) sr(-1) sec(-1) at a 90% confidence level for beta 3x 0.0001. Here, the results of a He:CH2 proportional tube array designed to extend the velocity limit down to beta approximately 0.0001 are reported. The detector which has been operating at the University of California, San Diego (UCSD) since last summer, is a prototype for a larger array currently under construction at UCSD. The data presented here is from 200 days of live time with the prototype detector.

Masek, G. E.↗

Current State of NASA Continuously Rotating Detonation Cycle Engine Development

NASA is currently investigating continuous detonation cycle engines for the application of lander and interplanetary space exploration missions. The performance benefits of a detonation cycle engine may allow for a broader design trade space and more compact geometry required for future missions to the Moon and onwards towards Mars. However, the technology readiness level (TRL) within the US was found to be low with several major risk factors that require understanding prior to full engine system development. One area of uncertainty is the extreme heat loads expected during thermal steady state conditions. To achieve this, an announcement for collaborative opportunity (ACO) partnership between IN Space LLC and NASA Marshall Space Flight Center (MSFC) was established to explore integration of additive manufacturing (AM) processes and the high conductance copper-based alloys, GRCop-42 and GRCop-84. This work outlines the hot fire testing of a 7K lbf thrust class fully AM GRCop-alloy rotating detonation rocket engine (RDRE). Two annular thrust chamber configurations emulating a lander engine system were tested with LOx/GH2 and LOx/LCH4. In both configurations, select hardware was actively cooled using de-ionized water and regeneratively cooled using LCH4. All primary hardware survived long duration tests to thermal steady state up to 133 seconds in a single burn. In total, 18 starts and 802 seconds of duration were achieved with and without visual confirmation of waves present. The proportion of burned propellant, or level of complete combustion, was found to be high compared to the theoretically achievable mean chamber pressure in all cases.

Thomas Teasley↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Measurement techniques and applications of charge transfer to aerospace research

A technique of developing high-velocity low-intensity neutral gas beams for use in aerospace research problems is described. This technique involves ionization of gaseous species with a mass spectrometer and focusing the resulting primary ion beam into a collision chamber containing a static gas at a known pressure and temperature. Equations are given to show how charge-transfer cross sections are obtained from a total-current measurement technique. Important parameters are defined for the charge-transfer process.

Smith, A.↗

Arc/gas electrode

A gas/arc electrode is disclosed for use under vacuum conditions where a first housing encloses a second housing, with an end of the second housing extending through an opening in the first housing and having an outlet orifice. Provisions are made for circulating a coolant through the first housing to surround and cool the second housing. An electrical current and a gas, such as argon, as passed through the second housing, with the current flowing through a narrow stream of the ionized gas flowing through the outlet orifice to a workpiece to be treated. The second housing forms a chamber which has a cross sectional area, in a plane perpendicular to the direction of gas flow, of at least ten times the cross sectional area of the outlet orifice such that a gas pressure can be maintained in the chamber to reduce erosion of the chamber walls.

Poorman, Richard M.↗

First Optical Constants of Laboratory-Generated Organic Refractory Materials (Tholins) Produced in the NASA Ames COSmIC Facility from the Visible to the Near Infrared (0.4–1.6 μm): Application to Titan’s Aerosols

We have measured the complex refractive indices, from 0.4 to 1.6μm, of five laboratory-generated organic refractory materials (tholins) produced at low temperature(150 K)using plasma chemistry in the stream of a supersonic expansion in NASA Ames’ COsmic SImulation Chamber(COSmIC)facility. Three samples were produced from N2:CH4gas precursors(with different voltages inducing different degrees of ionization in the plasma), one sample was produced from N2:CH4:C2H2, and one sample was produced from Ar:CH4in order to produce a purely carbonaceous sample. The optical constants, n and k, of the samples were determined using spectral reflectance measurements. We observe that both n and k appear to be correlated with the nitrogen content in the solid sample, with samples containing more nitrogen having higher n and k. Comparisons to previous laboratory studies and Titan aerosol optical constants derived from observations show that the COSmIC tholins with a higher nitrogen content (higher n and k)are closer analogs of Titan aerosols. We also present a new analysis of Cassini Visible Infrared Mapping Spectrometer observations of Titan’s atmosphere in the visible to near infrared using the COSmIC tholin optical constants in a radiative transfer model. The COSmIC tholin sample produced from N2:CH4with the lowest energy level has a spectral behavior that appears well suited to reproduce the observed Titan aerosol properties. This study has therefore demonstrated that this COSmIC tholin sample has valuable and promising optical properties for the analysis of Cassini’s Titan atmospheric observations.

Optical Constants↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

Gas flow analysis during thermal vacuum test of a spacecraft.

The pressures indicated by two tubulated ionization gages, one pointing to a spinning spacecraft undergoing thermal vacuum test and the other the walls of the chamber, have been used in a computer program to calculate important parameters of flow kinetics in the vacuum chamber. These parameters calculated as a function of time are: the self-contamination of the spacecraft (defined as the return of outgassed molecules on its critical surfaces either in orbit or while undergoing vacuum test); the spacecraft outgassing including leaks from sealed compartments; and the gas pumping performance of the vacuum chamber. The test indicated the feasibility of this type of evaluation and the improvements in instrumentations and arrangements needed for future tests.

Scialdone, J. J.↗

Gas Pressure Gauge Based on Alpha-Particle Induced Ion Currents

The use of ionization currents for measuring pressure was first demonstrated in the late 1940's. The early gauges operated at high voltages and used rather large ion sources. The ionization gauge is actually a densitometer that is sensitive to the temperature and pressure of the gas in the chamber. This report describes the use of low voltages and small ion sources in the development of a prototype.

transducers gas pressure gauge alpha particles ion↗

Large area plasma source

An all permanent magnet Electron Cyclotron Resonance, large diameter (e.g., 40 cm) plasma source suitable for ion/plasma processing or electric propulsion, is capable of producing uniform ion current densities at its exit plane at very low power (e.g., below 200 W), and is electrodeless to avoid sputtering or contamination issues. Microwave input power is efficiently coupled with an ionizing gas without using a dielectric microwave window and without developing a throat plasma by providing a ferromagnetic cylindrical chamber wall with a conical end narrowing to an axial entrance hole for microwaves supplied on-axis from an open-ended waveguide. Permanent magnet rings are attached inside the wall with alternating polarities against the wall. An entrance magnet ring surrounding the entrance hole has a ferromagnetic pole piece that extends into the chamber from the entrance hole to a continuing second face that extends radially across an inner pole of the entrance magnet ring.

Foster, John↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗