Comparison of gain degradation and deep level transient spectroscopy in pnp Si bipolar junction transistors irradiated with different ion species

Here, we studied the effect of light ion and heavy ion irradiations on pnp Si BJTs. A mismatch in DLTS deep peak amplitude for devices with same final gain but irradiated with different ion species was observed. Also, different ions cause different gain degradation when the DLTS spectra are matched. Pre-dosed ion-irradiated samples show that ion induced ionization does not account for the differences in DLTS peak height but isochronal annealing studies suggest that light ions produce more VP defects than heavy ions to compensate for the lack of clusters that heavy ions produce. The creation of defect clusters by heavy ions is evident by the higher content of E4 and V* 2 defects compared to light ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tritium Plasma Experiment Upgrade and Improvement of Surface Diagnostic Capabilities at STAR Facility for Enhancing Tritium and Nuclear PMI Sciences

The Tritium Plasma Experiment (TPE) is a unique high-flux linear plasma device that can handle beryllium, tritium, and neutron-irradiated plasma facing materials, and is the only existing device dedicated to directly study tritium retention and permeation in neutron-irradiated materials with tritium [M. Shimada et.al., Rev. Sci. Instru. 82 (2011) 083503 and and M. Shimada, et.al., Nucl. Fusion 55 (2015) 013008]. The plasma-material-interaction (PMI) determines a boundary condition for diffusing tritium into bulk PFCs, and the tritium PMI is crucial for enhancing fundamental sciences that dictate tritium fuel cycles and safety and are high importance to an FNSF and DEMO. Recently the TPE has undergone major upgrades in its electrical and control systems. New DC power supplies and a new control center enable remote plasma operations from outside of the contamination area for tritium, minimizing the possible exposure risk with tritium and beryllium. We discuss the electrical upgrade, enhanced operational safety, improved plasma performance, and development of optical spectrometer system. This upgrade not only improves operational safety of the worker, but also enhances plasma performance to better simulate extreme plasma-material conditions expected in ITER, Fusion Nuclear Science Facility (FNSF), and Demonstration reactor (DEMO). This work was prepared for the U.S. Department of Energy, Office of Fusion Energy Sciences, under the DOE Idaho Field Office contract number DE-AC07-05ID14517.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The capacitive properties of structures based on mesoporous silicon irradiated by low-dose γ rays

The influence of low doses of γ rays on the capacitive properties of structures based on mesoporous silicon has been investigated. The concentration distribution of dangling charged bonds over the layer depth, which changes under irradiation, has been found using the capacitance–voltage characteristics at different frequencies of the test signal. It is shown that the concentration and relaxation time of surface charged states in a structure with a mesoporous silicon layer decrease under γ irradiation, which makes the material promising for devices with controlled reactance (varactors) that are resistant to γ irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study on ion-irradiation-induced ferromagnetism in FeRh intermetallic compound by means of magnetic Compton scattering

The magnetic Compton profiles of Fe-50 at. % Rh intermetallic compound were measured to study the ferromagnetism induced by 200 MeV Xe ion irradiation. The magnetic effect at 50 K increases with increasing the ion-fluence. The analysis of the experimental result revealed that the values of spin moment induced by the irradiation were close to the values of magnetization obtained by a superconducting quantum interference device magnetometer, suggesting that the ion irradiation mainly induces the spin magnetic moment. The difference in magnetic Compton profiles between the irradiation-induced ferromagnetism and the intrinsic ferromagnetism in pure Fe is also discussed.

36 MATERIALS SCIENCE↗

Potential effects of low-dose average CT on cardiac implantable electronic devices

Background: Average CT has been shown to be more accurate than conventional helical CT in quantitation of the PET data. The risk of CT irradiation of a cardiac implantable electronic device (CIED) causing an adverse event is low and is generally outweighed by the clinical benefit of a medically indicated examination. However, irradiation of CIED over one breath cycle in cine CT scan for average CT could impose risks on a patient who is pacing dependent. The purpose of this study was to demonstrate that low-dose average CT can be safe for CIED. Methods: A Medtronic CIED of model Protecta VR was submerged in a saline bath for a series of 4-s cine CT scans on a GE CT scanner programmed to deliver a 2-cm-wide radiation at a dose rate of 0.9 to 41.2 mGy/s to the CIED. The number of over-sensings was recorded as the interference of radiation to the CIED. Results: Dose rates ≥ 1.9 mGy/s caused over-sensing. The higher the dose rate, the more over-sensings there were. The lowest dose rate of 0.9 mGy/s did not cause any over-sensing. Conclusions: Low-dose average CT at 0.9 mGy/s can be safe for a CIED patient who is pacing dependent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of a Focused, Pulsed X-ray Beam for Total Ionizing Dose Testing of Bipolar Linear Integrated Circuits

Here, we demonstrate the utility of focused, pulsed X-rays for investigating localized total ionizing dose effects in bipolar analog integrated circuits. Using the LM139 comparator as a test vehicle, we show how the technique can be used to identify the sources of degradation as a result of irradiating different transistors of the device and how this impacts the input bias current, input offset voltage, and output voltage. The 2-D mapping of the sensitive regions of transistors is presented, where the results of localized irradiation impact the monitored operational parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Alternative Technologies Adopters Outreach Survey Report

Brookhaven National Laboratory (BNL), in collaboration with Ioanna Iliopulos and Christopher Boyd (independent contractors), conducted quantitative and qualitative surveys to document views and opinions of scientists and researchers with firsthand experience operating x-ray devices for a wide range of research applications. The goal of the study was to fill critical information gaps and identify misconceptions widely held among the research community regarding the transition from Cesium-137 irradiators to x-ray devices. The survey instrument focused on three distinct yet interrelated areas that impact users' experience: operational impacts, including infrastructure needs, workflow, personnel management, and training, and regulatory compliance; research design and investigation impacts, including calibration, dosimetry, continuity of previous studies, development of new research agendas, and the outcomes for both; and funding impacts, specifically how grant sources and opportunities have responded to the transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical detwinning device for anisotropic resistivity measurements in samples requiring dismounting for particle irradiation

Uniaxial stress is used to detwin samples of orthorhombic iron based superconductors to study their intrinsic electronic anisotropy. Here we describe the development of a new detwinning setup enabling variable-load stress-detwinning with easy sample mounting/dismounting without the need to re-solder the contacts. It enables the systematic study of the anisotropy evolution as a function of an external parameter when the sample is modified between the measurements. In our case, the external parameter is the dose of 2.5 MeV electron irradiation at low temperature. We illustrate the approach by studying resistivity anisotropy in single crystals of Ba 1-x K x Fe 2 As 2 at x =0.25 where the much discussed unusual re-entrance of tetragonal C 4 phase, C 4 → C 2 → C 4 , is observed on cooling. With the described technique we found a significant anisotropy increase in C 2 phase after electron irradiation with dose of 2.35 C/cm 2 .

47 OTHER INSTRUMENTATION↗

Novel Use of the Contura for High Dose Rate Cranial Brachytherapy

A popular choice for treatment of recurrent gliomas was cranial brachytherapy using the GliaSite Radiation Therapy System. However, this device was taken off the market in late 2008, thus leaving a treatment void. This case study presents our experience treating a cranial lesion for the first time using a Contura multilumen, high-dose-rate (HDR) brachytherapy balloon applicator. The patient was a 47-year-old male who was diagnosed with a recurrent right frontal anaplastic oligodendroglioma. Previous radiosurgery made him a good candidate for brachytherapy. An intracavitary HDR balloon brachytherapy device (Contura) was placed in the resection cavity and treated with a single fraction of 20 Gy. The implant, treatment, and removal of the device were all completed without incident. Dosimetry of the device was excellent because the dose conformed very well to the target. V90, V100, V150, and V200 were 98.9%, 95.7%, 27.2, and 8.8 cc, respectively. This patient was treated successfully using the Contura multilumen balloon. Contura was originally designed for deployment in a postlumpectomy breast for treatment by accelerated partial breast irradiation. Being an intracavitary balloon device, its similarity to the GliaSite system makes it a viable replacement candidate. Multiple lumens in the device also make it possible to shape the dose delivered to the target, something not possible before with the GliaSite applicator.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recoverable degradation of blue InGaN-based light emitting diodes submitted to 3 MeV proton irradiation

This paper reports on the degradation and recovery of two different series of commercially available InGaN-based blue light emitting diodes submitted to proton irradiation at 3 MeV and various fluences (10{sup 11}, 10{sup 13}, and 10{sup 14} p{sup +}/cm{sup 2}). After irradiation, we detected (i) an increase in the series resistance, in the sub-turn-on current and in the ideality factor, (ii) a spatially uniform drop of the output optical power, proportional to fluence, and (iii) a reduction of the capacitance of the devices. These results suggest that irradiation induced the generation of non-radiative recombination centers near the active region. This hypothesis is further confirmed by the results of the recovery tests carried out at low temperature (150 °C)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resistive switching in a few nanometers thick tantalum oxide film formed by a metal oxidation

Resistive switching in a Cu/Ta{sub 2}O{sub 5}/Pt structure that consisted of a few nanometer-thick Ta{sub 2}O{sub 5} film was demonstrated. The Ta{sub 2}O{sub 5} film with thicknesses of 2–5 nm was formed with a combination of Ta metal film deposition and neutral oxygen particle irradiation at room temperature. The device exhibited a bipolar resistive switching with a threshold voltage of 0.2 V and multilevel switching operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stochastic Gain Degradation in III-V Heterojunction Bipolar Transistors due to Single Particle Displacement Damage

As device dimensions decrease single displacement effects are becoming more important. We measured the gain degradation in III-V Heterojunction Bipolar Transistors due to single particles using a heavy ion microbeam. Two devices with different sizes were irradiated with various ion species ranging from oxygen to gold to study the effect of the irradiation ion mass on the gain change. From the single steps in the inverse gain (which is proportional to the number of defects) we calculated Cumulative Distribution Functions to help determine design margins. The displacement process was modeled using the Marlowe Binary Collision Approximation (BCA) code. The entire structure of the device was modeled and the defects in the base-emitter junction were counted to be compared to the experimental results. While we found good agreement for the large device, we had to modify our model to reach reasonable agreement for the small device.

42 ENGINEERING↗

Impact of nuclear reactor radiation on the performance of AlN/sapphire surface acoustic wave devices

The performance of an AlN/sapphire surface acoustic wave (SAW) delay line device was characterized in real time under irradiation inside a nuclear reactor. Both its resonant frequency and transmission efficiency were observed to respond to a change in reactor power. The response follows an exponentially saturating behavior after a step power increase, followed by an exponentially decaying recovery after reactor shutdown. A sensitivity analysis based on the governing electro-mechanical equations shows that the frequency shift can be attributed to the softening of sapphire’s elastic constants under neutron radiation. Additionally, a kinetic rate equation is adopted to interpret device response and describe its microstructural evolution. These results suggest that the AlN/sapphire SAW device remains functional under irradiation, is sensitive to neutron and gamma ray fluxes, and offers an opportunity for remote sensing and in-situ measurement of material properties when exposed to nuclear reactor environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PVreference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as theincident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

14 SOLAR ENERGY↗

SU-E-T-487: Impact of Geometric Uncertainties in Accelerated Partial Breast Irradiation Using the Strut-Adjusted Volume Implant (SAVI)

Purpose: Single-entry multi-catheter devices have been developed for accelerated partial breast irradiation (APBI). Rotational and translational uncertainties are usually mitigated by quality assurance, however its actual dosimetric impact has not been addressed, which is presented here for SAVI applicator. Methods: Under Institutional Review Board exemption status, we retrospectively analyzed 48 APBI treatment plans using SAVI applicator. For quick calculation of dose-volume histogram (DVH) considering geometric uncertainties, the coordinate of each voxel of critical organs after rotation or translation along the central catheter was calculated using an in-house software instead of rotating or translating the entire dose distribution. Results: For most cases, the skin doses increased with rotation to both directions. At 10 degree of rotation, the increase of Dmax (percent prescribed dose) at 50% (median), 75%, 90%, and 100% (maximum) percentile were 0.3%, 1.7%, 5.6% and 25.0%, respectively. The increase of chest wall Dmax at 50%, 75%, 90%, and 100% percentile were 0.1%, 1.0%, 10.3% and 38.8%, respectively. The increase of skin Dmax of the patients with the distance between skin surface and lumpectomy cavity surface ≤16 mm was significantly larger than those with the distance >16 mm. Similarly, patients with the distance between lung and lumpectomy cavity surface ≤20 mm showed higher sensitivity of chest wall Dmax against rotation than patients with the distance <20 mm. Translation of the applicator showed larger impact on the skin dose than rotation, although the effects on chest wall was less than 2% even at 10 mm displacement. At 5 mm of translation, increase of skin Dmax at 50%, 75%, 90%, and 100% percentile were 2.3%, 8.0%, 15.3% and 77.7%, respectively. Conclusion: The impacts of the geometric uncertainties (rotation and translation) of SAVI applicator were investigated. The skin-lumpectomy cavity and lung-lumpectomy cavity distances showed significant relationship with skin and chest wall doses, respectively.

60 APPLIED LIFE SCIENCES↗

Influence of ultraviolet irradiation on data retention characteristics in resistive random access memory

With increasing density of memory devices, the issue of generating soft errors by cosmic rays is becoming more and more serious. Therefore, the irradiation resistance of resistance random access memory (ReRAM) to cosmic radiation has to be elucidated for practical use. In this paper, we investigated the data retention characteristics of ReRAM against ultraviolet irradiation with a Pt/NiO/ITO structure. Soft errors were confirmed to be caused by ultraviolet irradiation in both low- and high-resistance states. An analysis of the wavelength dependence of light irradiation on data retention characteristics suggested that electronic excitation from the valence to the conduction band and to the energy level generated due to the introduction of oxygen vacancies caused the errors. Based on a statistically estimated soft error rates, the errors were suggested to be caused by the cohesion and dispersion of oxygen vacancies owing to the generation of electron-hole pairs and valence changes by the ultraviolet irradiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical nanoscopy of high T c cuprate nanoconstriction devices patterned by helium ion beams

Helium ion beams (HIB) focused to subnanometer scales have emerged as powerful tools for high-resolution imaging as well as nanoscale lithography, ion milling, or deposition. Quantifying irradiation effects is an essential step toward reliable device fabrication, but most of the depth profiling information is provided by computer simulations rather than the experiment. Here, we demonstrate the use of atomic force microscopy (AFM) combined with scanning near-field optical microscopy (SNOM) to provide three-dimensional (3D) dielectric characterization of high-temperature superconductor devices fabricated by HIB. By imaging the infrared dielectric response obtained from light demodulation at multiple harmonics of the AFM tapping frequency, we find that amorphization caused by the nominally 0.5 nm HIB extends throughout the entire 26.5 nm thickness of the cuprate film and by ~500 nm laterally. This unexpectedly widespread damage in morphology and electronic structure can be attributed to a helium depth distribution substantially modified by the internal device interfaces. Lastly, our study introduces AFM-SNOM as a quantitative tomographic technique for noninvasive 3D characterization of irradiation damage in a wide variety of nanoscale devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pixel Detector Developments for Tracker Upgrades of the High Luminosity LHC

This paper reports on the INFN (Istituto Nazionale di Fisica Nucleare, Italy) research activity in collaboration with FBK foundry, which is aiming at the development of new pixel detectors for the LHC Phase-2 upgrades. The R&D covers both planar pixel devices and 3D detectors built using columnar technology. All sensors are low thickness n-in-p type, as this is the general direction envisaged for the High Luminosity LHC pixel detector upgrades. Hybrid modules with 100 $\upmu $ m and 130 $\upmu $ m active thickness, connected to the PSI46dig readout chip, have been tested on beam test experiments. Selected preliminary results from test beams are described for both planar and 3D devices. The results on the 3D pixel sensors before irradiation are very satisfactory and support the conclusion that columnar devices are very good candidates for the inner layers of the upgrade pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗