Search NASA⌕ Search

SEARCH · Search NASA

Results for “ISOTOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Isotope mass scaling and transport comparison between JET Deuterium and Tritium L-mode plasmas

The dimensionless isotope mass scaling experiment between pure Deuterium and pure Tritium plasmas with matched $\rho^*$, $\nu^*$ , β n , q and $T_e/T_i$ has been achieved in JET L-mode with dominant electron heating (NBI+ohmic) conditions. 28% higher scaled energy confinement time $B_t\tau_{E,\mathrm{th}}/A$ is found in favour of the Tritium plasma. This can be cast in the form of the dimensionless energy confinement scaling law as $\Omega_i \tau_{E,\mathrm{th}} \sim A^{0.48 \pm 0.16}$. This significant isotope mass scaling is consequently seen in the scaled one-fluid heat diffusion coefficient $A \chi_{\mathrm{eff}}/B_t$ which is around 50% lower in the Tritium plasma throughout the whole plasma radius. The isotope mass dependence in the particle transport channel is negligible, supported also by the perturbative particle transport analysis with gas puff modulation. The comparison of the edge particle fuelling or ionisation profiles from the EDGE2D-EIRENE simulations show that the absolute density differences that are necessary for the dimensionless match in the confined plasma dominate over any isotope mass dependencies of particle fuelling and ionization profiles at the plasma edge. Local GENE simulation results indicate a mild anti-gyroBohm effect at $\rho_\mathrm{tor}$ = 0.6 and thereby a small isotope mass dependence in favour of Tritium on heat transport and a negligible effect on particle transport. A significant fraction of the isotope scaling and reduced heat transport observed in the Tritium plasma is not captured in the GENE and ASTRA-TGLF-SAT2 simulations by simply changing the isotope mass for the same input profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variation of lead isotopic composition and atomic weight in terrestrial materials (IUPAC Technical Report)

The isotopic composition and atomic weight of lead are variable in terrestrial materials because its three heaviest stable isotopes are stable end-products of the radioactive decay of uranium ( 238 U to 206 Pb; 235 U to 207 Pb) and thorium ( 232 Th to 208 Pb). The lightest stable isotope, 204 Pb, is primordial. These variations in isotope ratios and atomic weights provide useful information in many areas of science, including geochronology, archaeology, environmental studies, and forensic science. While elemental lead can serve as an abundant and homogeneous isotopic reference, deviations from the isotope ratios in other lead occurrences limit the accuracy with which a standard atomic weight can be given for lead. In a comprehensive review of several hundred publications and analyses of more than 8000 samples, published isotope data indicate that the lowest reported lead atomic weight of a normal terrestrial materials is 206.1462 ± 0.0028 (k = 2), determined for a growth of the phosphate mineral monazite around a garnet relic from an Archean high-grade metamorphic terrain in north-western Scotland, which contains mostly 206 Pb and almost no 204 Pb. The highest published lead atomic weight is 207.9351 ± 0.0005 (k = 2) for monazite from a micro-inclusion in a garnet relic, also from a high-grade metamorphic terrain in north-western Scotland, which contains almost pure radiogenic 208 Pb. When expressed as an interval, the lead atomic weight is [206.14, 207.94]. It is proposed that a value of 207.2 be adopted for the single lead atomic-weight value for education, commerce, and industry, corresponding to previously published conventional atomic-weight values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SRF Resonators for a bi-directional Energy Ramping Upgrade of the Isotope Production Facility Beamline at LANL

The LANL Isotope Production Facility (IPF) is one of the two high-current proton linear accelerators operated under the auspices of the DOE Office of Nuclear Physics Isotope Development and Production for Research Applications Program. The IPF beamline operates with a fixed 100-MeV energy proton beam, diverted from the LANSCE accelerator and guided towards the isotope production target station. The fixed beam energy limits the number of isotopes that can be produced at IPF, and adversely affects the purity of isotopes produced at non-optimal energies. In particular, the IPF program is receiving increasing numbers of requests for high purity isotopes such as Np-236 (national security applications) and Re-186 (medical therapy). These are typically produced via (p,n) and (p,2n) nuclear reactions, requiring very tight control of the incident energies on the production targets to ensure an end product with a high radionuclidic purity. It is well known that this level of energy control cannot be achieved when a 100 MeV beam of mono-energetic protons is degraded to the required energies, typically below 30 MeV, as too much energy spread is acquired. Operating the IPF beamline at lower, mono-energetic beam energies such as at 40 MeV will allow the required tight energy control in target assemblies to ensure a high purity product. In addition, NP has requested a LANL/BNL/ORNL collaboration focus on establishing a national large-scale production capability for the therapy isotope Ac-225. Recent nuclear cross section measurements done at LANL show that due to a steep rise in production cross section towards higher proton energies (See Figure 2), proton beams at energies substantially greater than 100 MeV will be highly beneficial for Ac-225 production [AC255]. Such higher-energy beams cannot be delivered to IPF at present. Lower-energy beams (70 MeV and 40 MeV) can be delivered but only in sole-use mode; all other LANSCE users must be offline during 70 MeV or 40 MeV operation.

07 ISOTOPE AND RADIATION SOURCES↗

Origin of the isotopic composition of natural perchlorate: Experimental results for the impact of reaction pathway and initial ClO x reactant

Natural perchlorate (ClO 4 - ) exists in many places on Earth, in lunar regolith, meteorites, and on the surface of Mars. Terrestrial natural ClO 4 - has widely variable Cl and O stable isotopic compositions (δ 37 Cl, δ 18 O, Δ 17 O). The δ 18 O and Δ 17 O values of ClO 4 - from the most hyper-arid locations co-vary. ClO 4 - from less arid areas has relatively little 17 O excess and poor Δ 17 O-δ 18 O correlation. ClO 4 - from the Atacama Desert has unusually low δ 37 Cl (<-10‰) and exhibits a positive correlation between δ 37 Cl and δ 18 O, while the δ 37 Cl of ClO 4 - from all other locations varies between -5 and +7‰ with no δ 37 Cl-δ 18 O covariation. To evaluate the impact of different precursors (ClO x ) and reaction pathways on the isotopic composition of ClO 4 - , we measured the isotopic composition of ClO 4 - produced in the laboratory by UV or O 3 mediated aqueous oxidation of Cl-, OCl-, ClO2-, and ClO2° as well as O 3 mediated oxidation of dry NaCl. ClO x oxidation in aqueous or dry systems enriched in O 3 produced ClO 4 - with Δ 17 O values that generally increased with the number of O atoms required and included evidence that the site-specific 17 O anomaly in O 3 was preferentially transferred to ClO 4 - . Based on the inferred number of O atoms sourced from O 3 , and known Cl and O reaction pathways, it appears that ClO 2 ° and ClO 3 * were required intermediates in the production of ClO 4 - in the O 3 experiments. ClO x aqueous oxidation by UV irradiation produced ClO 4 - with a large range of δ 18 O values and little or no 17 O anomaly. ClO 3 - was produced to a much greater extent than ClO 4 - in all experiments except dry oxidation of NaCl by O 3 . The isotopic composition of ClO 3 - was distinct from that of ClO 4 - produced from the same initial reactants. Combined results of O 3 and UV mediated reactions largely bracketed the range of natural ClO 4 - δ 18 O and Δ 17 O values as well as δ 37 Cl values of non-Atacama natural samples, but no conditions produced the low δ 37 Cl values of Atacama ClO 4 - . Finally, our results indicate that variation in production mechanisms, possibly combined with isotopically variable precursors, could be responsible for much of the observed isotopic variation in natural ClO 4 - and ClO 3 - .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Framework for Quantifying past Methane Recycling by Sphagnum-Methanotroph Symbiosis Using Carbon and Hydrogen Isotope Ratios of Leaf Wax Biomarkers

The concentration of atmospheric methane is strongly linked to variations in Earth's climate. Currently, we can directly reconstruct the total atmospheric concentration of methane, but not individual terms of the methane cycle. Northern wetlands, dominated by Sphagnum, are an important contributor of atmospheric methane, and we seek to understand the methane cycle in these systems. We present a novel method for quantifying the proportion of carbon Sphagnum assimilates from its methanotrophic symbionts using stable isotope ratios of leaf-wax biomarkers. Carbon isotope ratios of Sphagnum compounds are determined by two competing influences, water content and the isotope ratio of source carbon. We disentangled these effects using a combined hydrogen and carbon isotope approach. We constrained Sphagnum water content using the contrast between the hydrogen isotope ratios of Sphagnum and vascular plant biomarkers. We then used Sphagnum water content to calculate the carbon isotope ratio of Sphagnum's carbon pool. Using a mass balance equation, we calculated the proportion of recycled methane contributed to the Sphagnum carbon pool, 'PRM.' We quantified PRM in peat monoliths from three microhabitats in the Mer Bleue peatland complex. Modern studies have shown that water table depth and vegetation have strong influences on the peatland methane cycle on instrumental time scales. With this new approach, delta C-13 of Sphagnum compounds are now a useful tool for investigating the relationships among hydrology, vegetation, and methanotrophy in Sphagnum peatlands over the time scales of entire peatland sediment records, vital to our understanding of the global carbon cycle through the Late Glacial and Holocene.

air pollution↗

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES↗

Bulk and position-specific isotope geochemistry of natural gases from the Late Cretaceous Eagle Ford Shale, south Texas

Here, a dataset of bulk and position-specific isotope compositions of shale gases from the Late Cretaceous Eagle Ford Shale, south Texas is reported. The chemical and bulk isotopic compositions of the seven samples in this study and those available from the literature show that across the play, produced natural gas from the Eagle Ford Shale preserves a wide range of gas compositions (wetness, ~5 to >90%) and δ 13 C values of C 1 –C 3 . The depth profiles of the isotopic compositions suggest that the western region of the Eagle Ford Shale deposit had experienced as much as 700–800 m of uplift-erosion or gas migration. The timing of and lost-gas fractions by gas expulsion events very likely affected their gas compositions and bulk isotope compositions. Some deep (>3000–3500 m), matured (%Ro > 1.5) gases with heavy δ 13 C(C 1 –C 3 ) values indicate significant loss (>50%) of the early-stage gases. For the position-specific isotope deviations of propane, the ΔC 2-1 values of the five samples show small decrease with well depths, while the ΔH 2-1 values have a general increasing trend. Although some samples fall very close to the equilibrium model trajectories with reasonable calculated temperatures (138–148 °C), the position-specific isotope compositions of propane from the Eagle Ford Shale gases are likely results of thermal cracking of various organic molecules within the source rocks, which have different activation energy for cracking and non-statistical distributions of C/H isotope within them.

58 GEOSCIENCES↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Simultaneous isotopic analysis of fission product Sr, Mo, and Ru in spent nuclear fuel particles by resonance ionization mass spectrometry

Abstract Fission product Sr, Mo, and Ru isotopes in six 10-μm particles of spent fuel from a pressurized water reactor were analyzed by resonance ionization mass spectrometry (RIMS) and evaluated for utility in nuclear material characterization. Previous measurements on these same samples showed widely varying U, Pu, and Am isotopic compositions owing to the samples’ differing irradiation environments within the reactor. This is also seen in Mo and Ru isotopes, which have the added complication of exsolution from the UO 2 fuel matrix. This variability is a hindrance to interpreting data from a collection of particles with incomplete provenance since it is not always possible to assign particles to the same batch of fuel based on isotopic analyses alone. In contrast, the measured 90 Sr/ 88 Sr ratios were indistinguishable across all samples. Strontium isotopic analysis can therefore be used to connect samples with otherwise disparate isotopic compositions, allowing them to be grouped appropriately for interpretation. Strontium isotopic analysis also provides a robust chronometer for determining the time since fuel irradiation. Because of the very high sensitivity of RIMS, only a small fraction of material in each of the 10 μm samples was consumed, leaving the vast majority still available for other analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detection of Isotopes in Urban Source Search Gamma Spectra Using Hopfield Neural Network

Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRIFT: Diffusivity Regulation of Isotopes by nanoconFinementT

Spontaneous isotope fractionation has been reported under nanoconfinement conditions in naturally occurring systems, but the origin of this phenomena is currently unknown. Two existing hypotheses have been proposed, one based on changes in the solvation environment of the isotopes that reduces the non-mass dependent hydrodynamics contribution to diffusion. The other is that isotopes have mass-dependent surface adsorption, varying their total diffusion through nanoconfined channels. To investigate these hypotheses, benchtop experiments, nuclear magnetic resonance (NMR) spectroscopy, and molecule scale modeling were applied. Classical molecular dynamics simulations identified that the Na + and Cl - hydration shells across the three different salt solutions ( 22 Na 35 Cl, 23 Na 35 Cl, 24 Na 35 Cl) did not vary as a function of the Na + isotope, but that there was a significant pore size effect, with larger hydration shells at larger pore sizes. Additionally, while total adsorption times did not vary as a function of the Na + isotope or pore size, the free ion concentration, or those adsorbed on the surface for <5% of the simulation time did exhibit isotope dependence. Experimentally, challenges occurred developing a repeatable experiment, but NMR characterization of water diffusion rates through ordered alumina membranes was able to identify the existence of two distinct water environments associated with water inside and outside the pore. Further NMR studies could be used to confirm variation in hydration shells and diffusion rates of dissolved ions in water. Ultimately, mass-dependence adsorption is a primary driver of variations in isotope diffusion rates, rather than variation in hydration shells that occur under nanoconfinement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isotope separation using tuned laser and electron beam

The apparatus comprises means for producing an atomic beam containing the isotope of interest and other isotopes. Means are provided for producing a magnetic field traversing the path of the atomic beam of an intensity sufficient to broaden the energy domain of the various individual magnetic sublevels of the isotope of interest and having the atomic beam passing therethrough. A laser beam is produced of a frequency and polarization selected to maximize the activation of only individual magnetic sublevels of the isotope of interest with the portion of its broadened energy domain most removed from other isotopes with the stream. The laser beam is directed so as to strike the atomic beam within the magnetic field and traverse the path of the atomic beam whereby only the isotope of interest is activated by the laser beam. The apparatus further includes means for producing a collimated and high intensity beam of electrons of narrow energy distribution within the magnetic field which is aimed so as to strike the atomic beam while the atomic beam is simultaneously struck by the laser beam and at an energy level selected to ionize the activated isotope of interest but not ground state species included therewith. Deflection means are disposed in the usual manner to collect the ions.

Trajmar, Sandor↗

Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

Freeman, K. H.↗

The identification of meteorite inclusions with isotope anomalies

Ca-Al refractory inclusions with characteristic chemical and mineralogical compositions show an enhanced occurrence of 20 pct of isotope anomalies reflecting unknown nucleosynthetic effects for O and Mg. The anomalies are characterized by large isotope fractionation in Mg, apparent deficits in Mg-26/Mg-24, and large correlated effects for isotopes of Ca, Ti, and Cr. These isotope patterns define exotic components depleted in the most neutron-rich isotopes of Ca, Ti, and Cr, or components depleted in isotopes produced in explosive O and Si burning. An opaque assemblage within one of the inclusions yields isotope anomalies in Cr similar to the bulk inclusion and must be intrinsically part of the inclusion and not a trapped, foreign grain aggregate.

Papanastassiou, D. A.↗

Isotopic constraints on the origin of meteoritic organic matter

Salient features of the isotopic distribution of H, C and N in the organic material found in carbonaceous meteorites are noted. Most organic fractions are strongly enriched in D with respect to the D/H ratio characteristic of H2 in the protosolar system; substantial variations in C-13/C-12 ratio are found among different molecular species, with oxidised species tending to be C-13 enriched relative to reduced species; some homologous series reveal systematic decrease in C-13/C-12 with increasing C number; considerable variation in N-15/N-14 ratio is observed within organic matter, though no systematic pattern to its distribution has yet emerged; no interelement correlations have been observed between isotope enrichments for the different biogenic elements. The isotopic complexity echoes the molecular diversity observed in meteoritic organic matter and suggests that the organic matter was formed by multiple processes and/or from multiple sources. However, existence of a few systematic patterns points towards survival of isotopic signatures characteristic of one or more specific processes. The widespread D enrichment implies either survival of many species of interstellar molecule or synthesis from a reservoir containing a significant interstellar component. Several of the questions raised above can be addressed by more detailed determination of the distribution of the H, C and N isotopes among different well-characterized molecular fractions. Thus, the present study is aimed at discovering whether the different amino acids have comparable D enrichments, which would imply local synthesis from a D-enriched reservoir, or very viable D enrichments, which would imply survival of some interstellar amino acids. The same approach is also being applied to polycyclic aromatic hydrocarbons. Because the analytical technique employed (secondary ion mass spectrometry) can acquire data for all three isotopic systems from each molecular fraction, any presently obscured interelement isotopic correlation should also be revealed, which will aid in identifying pertinent synthetic processes.

Kerridge, J. F.↗

Variations of the isotopic composition of sulfur in enstatite and ordinary chondrites

High-precision sulfur isotopic analyses (delta S-33, delta S-34, and delta S-36) of bulk ordinary and enstatite chondrites demonstrate that systematic variations exist. The average delta S-34 values are -0.26 +/- 0.07, -0.02 +/- 0.06, and 0.49 +/- 0.16 percent for enstatite and ordinary and carbonaceous chondrites, respectively. Isotopic variations of different sample specimens of primitive meteorites, e.g., Qingzhen and Abee, were observed which may be attributed to heterogeneity in the early solar nebula. Sulfur isotopic fractionations in both bulk samples and mineral separates are mass-dependent, and no nuclear isotopic anomalies were detected. The sulfur isotopic compositions of both mineral and density separates were measured. The sulfur isotopic compositions of separated chondrules from Chainpur and Bjurbole are reported. Significant isotopic difference for the chondrules from the bulk meteorite are noted for both meteorites.

Gao, Xia↗

Effects of isotope selection on solution convergence in HZE transport

A fragmenting iron ion produces hundreds of isotopes during nuclear reactions. These isotopes are represented in the solution of the transport problem. A reduced set of isotopes is selected to minimize the computational burden but introduces error in the final result. A minimum list of 122 isotopes is required for adequate representation of the mass and charge distributions of the secondary radiation fields. A reduced set of 80 isotopes is sufficient to represent the charge distribution alone and represents reasonably well the linear energy transfer properties of the iron beam. Because iron fragmentation produces nearly every isotope lighter than iron, the resulting 122-isotope list should be adequate for ion beams with charges equal to or less than 26.

Kim, Myung-Hee Y.↗