Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

HopBox: An image analysis pipeline to characterize hop cone morphology

Abstract Hop cone morphology can influence picking and drying ability, and color can impact consumer preference and may be indicative of quality. However, these characteristics are not generally evaluated in hop breeding programs due to the tedious nature of trait quantification and the extensive variation among cones within a genotype. We developed the HopBox, which is a simply constructed light box with a camera mount, and a publicly available image processing pipeline that identifies hop cones within color‐corrected images, reads a QR code within the image, and outputs data on hop cone length, width, area, perimeter, openness, weight, color, and density. The trained model was applied to images of 500 cones each from 15 replicated advanced hop genotypes from the USDA‐ARS breeding program in Prosser, Washington. Analysis of variance revealed significant ( p < 0.001) differences between genotypes for all traits measured, enabling breeders to discriminate between genotypes for selection purposes. Broad sense heritability for all traits ranged from 0.23 to 0.59. A random sampling of hop cones from the complete dataset revealed that imaging only 5–10 cones adequately captured genotypic variation and provided acceptable rank correlations ( r s > 0.75); however, increasing the sample size to 30 provided optimal precision. Instructions for constructing a HopBox and the code for the analysis pipeline are publicly available online and have wide applicability for hop breeding and research.

Altendorf, Kayla R.↗

A Visual Database System for Image Analysis on Parallel Computers and its Application to the EOS Amazon Project

The goal of this task was to create a design and prototype implementation of a database environment that is particular suited for handling the image, vision and scientific data associated with the NASA's EOC Amazon project. The focus was on a data model and query facilities that are designed to execute efficiently on parallel computers. A key feature of the environment is an interface which allows a scientist to specify high-level directives about how query execution should occur.

Shapiro, Linda G.↗

Image analysis of jet structure on electrospinning from free liquid surface

The work analyses intra-jet distances during electrospinning from a free surface of water based poly(vinyl alcohol) solution confined by two thin metallic plates employed as a spinning electrode. A unique computer vision system and digital image processing were designed in order to track position of every polymer jet. Here, we show that jet position data are in good compliance with theoretically predicted intra-jet distances by linear stability analysis. Jet density is a critical parameter of electrospinning technology, since it determines the process efficiency and homogeneity of produced nanofibrous layer. Achievements made in this research could be used as essential approach to study jetting from two-dimensional spinning electrodes, or as fundamentals for further development of control system related to Nanospider{sup ™} technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lateral Diffusion Estimation in Fully Depleted Thick CCD Using Flat Field Image Analysis

In thick fully depleted CCDs charge carrier transport from the back window to the gates is accompanied by charge diffusion. Lateral diffusion smooths out density variations of the incoming photon flux by redistributing charges spatially. This creates short range positive correlations in recorded amplitudes. Pixel-to-pixel amplitude variations can also be caused by pixel size and quantum efficiency variations. Pixel size variations result in short range negative correlations. Our study shows that the characteristic diffusion width can be extracted from flat field data. The study was performed on fully depleted, thick CCDs produced in a technology study for the Large Synoptic Survey Telescope (LSST). Data were taken in the laboratory at bias voltages between -5 and -40 V. To increase statistical accuracy, images taken in identical conditions were co-added after base line subtraction and master files were produced. A flat field image simulator was developed for statistical comparison of simulated and measured images. Results on diffusion, pixel response variations, data features, analysis and modeling techniques are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hypergravity exposure decreases gamma-aminobutyric acid immunoreactivity in axon terminals contacting pyramidal cells in the rat somatosensory cortex: a quantitative immunocytochemical image analysis

Quantitative evaluation of gamma-aminobutyric acid immunoreactivity (GABA-IR) in the hindlimb representation of the rat somatosensory cortex after 14 days of exposure to hypergravity (hyper-G) was conducted by using computer-assisted image processing. The area of GABA-IR axosomatic terminals apposed to pyramidal cells of cortical layer V was reduced in rats exposed to hyper-G compared with control rats, which were exposed either to rotation alone or to vivarium conditions. Based on previous immunocytochemical and behavioral studies, we suggest that this reduction is due to changes in sensory feedback information from muscle receptors. Consequently, priorities for muscle recruitment are altered at the cortical level, and a new pattern of muscle activity is thus generated. It is proposed that the reduction observed in GABA-IR of the terminal area around pyramidal neurons is the immunocytochemical expression of changes in the activity of GABAergic cells that participate in reprogramming motor outputs to achieve effective movement control in response to alterations in the afferent information.

Non-NASA Center↗

Cone Beam CT Imaging Analysis of Interfractional Variations in Bladder Volume and Position During Radiotherapy for Bladder Cancer

Purpose: To quantify daily bladder size and position variations during bladder cancer radiotherapy. Methods and Materials: Ten bladder cancer patients underwent daily cone beam CT (CBCT) imaging of the bladder during radiotherapy. Bladder and planning target volumes (bladder/PTV) from CBCT and planning CT scans were compared with respect to bladder center-of-mass shifts in the x (lateral), y (anterior-posterior), and z (superior-inferior) coordinates, bladder/PTV size, bladder/PTV margin positions, overlapping areas, and mutually exclusive regions. Results: A total of 262 CBCT images were obtained from 10 bladder cancer patients. Bladder center of mass shifted most in the y coordinate (mean, -0.32 cm). The anterior bladder wall shifted the most (mean, -0.58 cm). Mean ratios of CBCT-derived bladder and PTV volumes to planning CT-derived counterparts were 0.83 and 0.88. The mean CBCT-derived bladder volume (+- standard deviation [SD]) outside the planning CT counterpart was 29.24 cm{sup 3} (SD, 29.71 cm{sup 3}). The mean planning CT-derived bladder volume outside the CBCT counterpart was 47.74 cm{sup 3} (SD, 21.64 cm{sup 3}). The mean CBCT PTV outside the planning CT-derived PTV was 47.35 cm{sup 3} (SD, 36.51 cm{sup 3}). The mean planning CT-derived PTV outside the CBCT-derived PTV was 93.16 cm{sup 3} (SD, 50.21). The mean CBCT-derived bladder volume outside the planning PTV was 2.41 cm{sup 3} (SD, 3.97 cm{sup 3}). CBCT bladder/ PTV volumes significantly differed from planning CT counterparts (p = 0.047). Conclusions: Significant variations in bladder and PTV volume and position occurred in patients in this trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AGR-1 UCO Kernel Phase Analysis Imaging Archive

UCO kernels in tri-structural isotropic (TRISO) particles consist of a heterogeneous mixture of uranium oxide and uranium carbide. During the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program, mean kernel composition was specified based on bulk measurements of uranium, oxygen, and carbon content, as well as the resulting O/U, C/U, and O+C/U ratios. Further development of quality control characterization methods has resulted in a method for more direct measurement of phase fractions on a per-kernel basis using optical microscopy of polished kernel cross sections. This report provides benchmark values for this analysis method when applied to kernels from the AGR-1 campaign and to the raw images used.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automating MISSE Specimens Image Analysis

The Materials International Space Station Experiment (MISSE) Project consists of experiments focused on the investigation of the effects that occur through the exposure of materials specimens in the space environment. To determine if there is a change in a specimen, the data obtained from the MISSE high-resolution photographic images can be monitored. For this, a compilation of folders was created to provide an organizational system. Each mission was divided into the specific direction in space, materials specimen, and date the image was taken. This organization helps to identify how a specimen behaves as a function of time in the space environment. Once the images were classified, a qualitative process was first used to detect an evolution in the materials of MISSE-9 - MISSE-14.

MISSE ISS Materials↗

Quantitative Image Analysis Techniques with High-Speed Schlieren Photography

Optical flow visualization techniques such as schlieren and shadowgraph photography are essential to understanding fluid flow when interpreting acquired wind tunnel test data. Output of the standard implementations of these visualization techniques in test facilities are often limited only to qualitative interpretation of the resulting images. Although various quantitative optical techniques have been developed, these techniques often require special equipment or are focused on obtaining very precise and accurate data about the visualized flow. These systems are not practical in small, production wind tunnel test facilities. However, high-speed photography capability has become a common upgrade to many test facilities in order to better capture images of unsteady flow phenomena such as oscillating shocks and flow separation. This paper describes novel techniques utilized by the authors to analyze captured high-speed schlieren and shadowgraph imagery from wind tunnel testing for quantification of observed unsteady flow frequency content. Such techniques have applications in parametric geometry studies and in small facilities where more specialized equipment may not be available.

Pollard, Victoria J.↗

Performance and Image Analysis of the Aberration Corrected Hitachi HD-2700C Stem

We report the performance of the first aberration-corrected scanning transmission electron microscope (STEM) manufactured by Hitachi. We describe its unique features and versatile capabilities in atomic-scale characterization and its applications in materials research. We also discuss contrast variation of the STEM images obtained from different annular dark-field (ADF) detectors of the instrument, and the increased complexity in contrast interpretation and quantification due to the increased convergent angles of the electron probe associated with the aberration corrector. We demonstrate that the intensity of atomic columns in an ADF image depends strongly on a variety of imaging parameters, sample thickness, as well as the nuclear charge and the deviation from their periodic position of the atoms we are probing. Image simulations are often required to correctly interpret the atomic structure of an ADF-STEM image.

36 MATERIALS SCIENCE↗

A NEW TOOL FOR IMAGE ANALYSIS BASED ON CHEBYSHEV RATIONAL FUNCTIONS: CHEF FUNCTIONS

We introduce a new approach to the modeling of the light distribution of galaxies, an orthonormal polar basis formed by a combination of Chebyshev rational functions and Fourier polynomials that we call CHEF functions, or CHEFs. We have developed an orthonormalization process to apply this basis to pixelized images, and implemented the method as a Python pipeline. The new basis displays remarkable flexibility, being able to accurately fit all kinds of galaxy shapes, including irregulars, spirals, ellipticals, highly compact, and highly elongated galaxies. It does this while using fewer components than similar methods, as shapelets, and without producing artifacts, due to the efficiency of the rational Chebyshev polynomials to fit quickly decaying functions like galaxy profiles. The method is linear and very stable, and therefore is capable of processing large numbers of galaxies in a fast and automated way. Due to the high quality of the fits in the central parts of the galaxies, and the efficiency of the CHEF basis modeling galaxy profiles up to very large distances, the method provides highly accurate estimates of total galaxy fluxes and ellipticities. Future papers will explore in more detail the application of the method to perform multiband photometry, morphological classification, and weak shear measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Chemical Imaging Analysis of Environmental Particles Using the Focused Ion Beam/Scanning Electron Microscopy Technique. Microanalysis Insights into Atmospheric Chemistry of Fly Ash

Airborne fly ash from coal combustion may represent a source of bioavailable iron (Fe) in the open ocean. However, few studies have been made focusing on Fe speciation and distribution in coal fly ash. In this study, chemical imaging of fly ash has been performed using a dual-beam FIB/SEM (focused ion beam/scanning electron microscope) system for a better understanding of how simulated atmospheric processing modify the morphology, chemical compositions and element distributions of individual particles. A novel approach has been applied for cross-sectioning of fly ash specimen with a FIB in order to explore element distribution within the interior of individual particles. Our results indicate that simulated atmospheric processing causes disintegration of aluminosilicate glass, a dominant material in fly ash particles. Aluminosilicate-phase Fe in the inner core of fly ash particles is more easily mobilized compared with oxide-phase Fe present as surface aggregates on fly ash spheres. Fe release behavior depends strongly on Fe speciation in aerosol particles. The approach for preparation of cross-sectioned specimen described here opens new opportunities for particle microanalysis, particular with respect to inorganic refractive materials like fly ash and mineral dust.

Environmental Molecular Sciences Laboratory↗

Comparison of two different methods of image analysis for the assessment of microglial activation in patients with multiple sclerosis using (R)-[N-methyl-carbon-11]PK11195

Chronic active multiple sclerosis (MS) lesions have a rim of activated microglia/macrophages (m/M) leading to ongoing tissue damage, and thus represent a potential treatment target. Activation of this innate immune response in MS has been visualized and quantified using PET imaging with [ 11C]-(R)-PK11195 (PK). Accurate identification of m/M activation in chronic MS lesions requires the sensitivity to detect lower levels of activity within a small tissue volume. We assessed the ability of kinetic modeling of PK PET data to detect m/M activity in different central nervous system (CNS) tissue regions of varying sizes and in chronic MS lesions. Ten patients with MS underwent a single brain MRI and two PK PET scans 2 hours apart. Volume of interest (VOI) masks were generated for the white matter (WM), cortical gray matter (CGM), and thalamus (TH). The distribution volume (VT) was calculated with the Logan graphical method (LGM-VT) utilizing an image-derived input function (IDIF). The binding potential (BPND) was calculated with the reference Logan graphical method (RLGM) utilizing a supervised clustering algorithm (SuperPK) to determine the non-specific binding region. Masks of varying volume were created in the CNS to assess the impact of region size on the various metrics among high and low uptake regions. Chronic MS lesions were also evaluated and individual lesion masks were generated. The highest PK uptake occurred the TH and lowest within the WM, as demonstrated by the mean time activity curves. In the TH, both reference and IDIF based methods resulted in estimates that did not significantly depend on VOI size. However, in the WM, the test-retest reliability of BPND was significantly lower in the smallest VOI, compared to the estimates of LGM-VT. These observations were consistent for all chronic MS lesions examined. In this study, we demonstrate that BPND and LGM-VT are both reliable for quantifying m/M activation in regions of high uptake, however with blood input function LGM-VT is preferred to assess longitudinal m/M activation in regions of relatively low uptake, such as chronic MS lesions.

60 APPLIED LIFE SCIENCES↗

Beyond Binary: Automated PLC Memory Forensics through RGB Image Analysis and Deep Learning

The introduction of Industry 4.0 and the evolution of industrial control systems (ICS) to adopt Internet-based technologies enhanced productivity, but have inadvertently increased their vulnerability to cyber-based malicious attacks. When an ICS system is compromised, security analysts need to identify the root cause quickly to start the recovery process and develop mitigation strategies to safeguard against future instances. Memory forensics is critical in the analysis process to ascertain what occurred. To date, approaches to analyze the persistent memory in ICS devices are limited, and almost nonexistent for volatile memory. This paper proposes an automated methodology, COMA, for PLC memory dump analysis using computer vision and deep learning techniques. Specifically, COMA converts the sequences of bytes in a PLC memory dump to RGB pixels and creates a deep learning model that learns the underlying patterns and features of pre-labeled forensic artifacts in images and segments them into distinct regions. COMA then uses the trained model to automatically segment new memory images and extract forensic artifacts. We evaluate COMA on a Schneider Electric Modicon M221 PLC involving two cyber-based attack scenarios: (i) code injection and (ii) code modification. The empirical results show that COMA can successfully detect attack artifacts in memory dumps in both scenarios.

Asmar Awad, Rima↗

Image Analysis as a Tool for Satellite-Earth Propagation Studies

We present a progress report on a useful new method to assess propagation problems for outdoor mobile Earth-satellite paths. The method, Photogrammetric Satellite Service Prediction (PSSP) is based on the determination of Land Mobile Satellite Systems (LMSS) service attributes at the locations of static or mobile LMSS service users by evaluating fisheye images of their environment. This paper gives an overview of the new method and its products.

Akturan, Riza↗

Detection of Esophageal Fiducial Marker Displacement During Radiation Therapy With a 2-dimensional On-board Imager: Analysis of Internal Margin for Esophageal Cancer

Purpose: To quantify the interfraction displacement of esophageal fiducial markers for primary esophageal cancer radiation therapy. Methods and Materials: Orthogonal 2-dimensional (2D) matching records fused to vertebrae were analyzed in clinically staged T1/2N0 esophageal cancer patients undergoing endoscopic clipping as fiducial metal markers. Displacement of the markers between the digitally reconstructed radiographs and on-board kilovoltage images during radiation therapy was analyzed according to direction and esophageal site. Results: Forty-four patients, with 81 markers (10 proximal, 42 middle, and 29 distal), underwent 367 2D matching sessions during radiation therapy. The mean (SD) absolute marker displacement was 0.26 (0.30) cm in the right–left (RL), 0.50 (0.39) cm in the superior–inferior (SI), and 0.24 (0.21) cm in the anterior–posterior (AP) direction. Displacement was significantly larger in the SI than in the RL and AP directions (P<.0001). In the SI direction, mean absolute displacements of the distal, middle, and proximal esophagus were 0.67 (0.45) cm, 0.42 (0.32) cm, and 0.36 (0.30) cm, respectively. Distal esophagus displacement was significantly larger than those of the middle and proximal esophagus (P<.0001). The estimated internal margin to cover 95% of the cases was 0.75 cm in the RL and AP directions. In the SI direction, the margin was 1.25 cm for the proximal and middle esophagus and 1.75 cm for the distal esophagus. Conclusions: The magnitude of interfraction displacement of esophageal clips was larger in the SI direction, particularly in the distal esophagus, but substantial displacement was observed in other directions and at other esophageal sites. It is practical to take estimated movements into account with internal margins, even if vertebrae-based 2D matching is performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time video-image analysis

Digitizer and storage system allow rapid random access to video data by computer. RAPID (random-access picture digitizer) uses two commercially-available, charge-injection, solid-state TV cameras as sensors. It can continuously update its memory with each frame of video signal, or it can hold given frame in memory. In either mode, it generates composite video output signal representing digitized image in memory.

Eskenazi, R.↗