Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Capturing Maize Stand Heterogeneity Across Yield-Stability Zones Using Unmanned Aerial Vehicles (UAV)

Despite the new equipment capabilities, uneven crop stands are still common occurrences in crop fields, mainly due to spatial heterogeneity in soil conditions, seedling mortality due to herbivore predation and disease, or human error. Non-uniform plant stands may reduce grain yield in crops like maize. Thus, detecting signs of variability in crop stand density early in the season provides critical information for management decisions and crop yield forecasts. Processing techniques applied on images captured by unmanned aerial vehicles (UAVs) has been used successfully to identify crop rows and estimate stand density and, most recently, to estimate plant-to-plant interval distance. Here, we further test and apply an image processing algorithm on UAV images collected from yield-stability zones in a commercial crop field. Our objective was to implement the algorithm to compare variation of plant-spacing intervals to test whether yield differences within these zones are related to differences in crop stand characteristics. Our analysis indicates that the algorithm can be reliably used to estimate plant counts (precision >95% and recall >97%) and plant distance interval (R2 ~0.9 and relative error <10%). Analysis of the collected data indicated that plant spacing variability differences were small among plots with large yield differences, suggesting that it was not a major cause of yield variability across zones with distinct yield history. This analysis provides an example of how plant-detection algorithms can be applied to improve the understanding of patterns of spatial and temporal yield variability.

47 OTHER INSTRUMENTATION↗

Quantitative Analysis of Flow Processes in a Sand Using Synchrotron-Based X-ray Microtomography

Pore-scale multiphase flow experiments were developed to nondestructively visualize water flow in a sample of porous material using X-ray microtomography. The samples were exposed to similar boundary conditions as in a previous investigation, which examined the effect of initial flow rate on observed dynamic effects in the measured capillary pressure-saturation curves; a significantly higher residual saturation and higher capillary pressures were found when the sample was drained fast using a high air-phase pressure. Prior work applying the X-ray microtomography technique to pore-scale multiphase flow problems has been of a mostly qualitative nature and no experiments have been presented in the existing literature where a truly quantitative approach to investigating the multiphase flow process has been taken, including a thorough image-processing scheme. The tomographic images presented here show, both by qualitative comparison and quantitative analysis in the form of a nearest neighbor analysis, that the dynamic effects seen in previous experiments are likely due to the fast and preferential drainage of large pores in the sample. Once a continuous drained path has been established through the sample, further drainage of the remaining pores, which have been disconnected from the main flowing water continuum, is prevented.

42 ENGINEERING↗

Initial Assessment of X-Ray Computer Tomography image analysis for material defect microstructure

The original development work leading to this report was focused on the non destructive three-dimensional (3-D) characterization of nuclear graphite as a means to better understand the nature of the inherent pore structure. The pore structure of graphite and its evolution under various environmental factors such as irradiation, mechanical stress, and oxidation plays an important role in their observed properties and characteristics. If we are to transition from an empirical understanding of graphite behavior to a truly predictive mechanistic understanding the pore structure must be well characterized and understood. As the pore structure within nuclear graphite is highly interconnected and truly 3-D in nature, 3-D characterization techniques are critical. While 3-D characterization has been an excellent tool for graphite pore characterization, it is applicable to a broad number of materials systems over many length scales. Given the wide range of applications and the highly quantitative nature of the tool, it is quite surprising to discover how few materials researchers understand and how valuable of a tool 3-D image processing and analysis can be. Ultimately, this report is intended to encourage broader use of 3 D image processing and analysis in materials science and engineering applications, more specifically nuclear-related materials applications, by providing interested readers with enough familiarity to explore its vast potential in identifying microstructure changes. To encourage this broader use, the report is divided into two main sections. Section 2 provides an overview of some of the key principals and concepts needed to extract a wide variety of quantitative metrics from a 3-D representation of a material microstructure. The discussion includes a brief overview of segmentation methods, connective components, morphological operations, distance transforms, and skeletonization. Section 3 focuses on the application of concepts from Section 2 to relevant materials at Idaho National Laboratory. In this section, image analysis examples featuring nuclear graphite will be discussed in detail. Additionally, example analyses from Transient Reactor Test Facility low-enriched uranium conversion, Advanced Gas Reactor like compacts, and tristructural isotopic particles are shown to give a broader perspective of the applicability to relevant materials of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the possibility of a significant improvement in the quality of a quantum ghost image by registering an additional image in the object channel

A modification of the classical scheme of the quantum ghost image formation is considered, in which an image of the object under study is formed and recorded in the object channel. This image is used together with the ghost image to construct an estimate of the transparency distribution of the object. It is shown that this technique reduces the image quality worsening associated with the non-unit quantum efficiency of the sensors, even when the quantum image obtained in the object channel is additionally distorted by noise due to photons that did not interact with the object. (image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DARHT Radiographic Grid Scale Correction

Recently it became apparent that the radiographic grid which has been used to calibrate the dimensional scale of DARHT radiographs was not centered at the location where the objects have been centered. This offset produced an error of 0.188% in the dimensional scaling of the radiographic images processed using the assumption that the grid and objects had the same center. This paper will show the derivation of the scaling correction, explain how new radiographs are being processed to account for the difference in location, and provide the details of how to correct radiographic image processed with the erroneous scale factor.

47 OTHER INSTRUMENTATION↗

Radiographic Magnification Differences Due To Grid Placement at DARHT

In 2015, it became apparent that the radiographic grid, which has been used to calibrate the dimensional scale of DARHT radiographs, was not centered at the location where the objects have been centered along the beamline. Instead of the grid center being placed at 133.0 cm, the grid downstream face was placed at this location, putting the grid center at 132.75 cm. This o set produced an error of 0.188% in the dimensional scaling of the radiographic images processed, using the assumption that the grid and objects had the same center. The Air Force Target (AFT) had the same holder as the grid, while the Circular Resolution Target (CRT) used a holder that correctly placed the object center at 133.0 cm. These erroneous holders were used until October 2015. Starting in November 2015, new holders were used that placed all static target objects in the correct location, with their center at 133.0 cm. This paper will show the derivation of the scaling correction, explain how old radiographs are being processed to account for the difference in location, and provide the details of how to correct radiographic images processed with the erroneous scale factor.

47 OTHER INSTRUMENTATION↗

Three-dimensional visualization and characterization of bone structure using reconstructed in-vitro μCT images: A pilot study for bone microarchitecture analysis

Micro Computed Tomography (μCT) has been largely used to perform micrometer scale imaging of specimens, bone biopsies and small animals for the study of porous or cavity-containing objects. One of its favored applications is for assessing structural properties of bone. In this research, we perform a pilot study to visualize and characterize bone structure of a chicken bone thigh, as well as to delineate its cortical and trabecular bone regions. We utilize an In-Vitro μCT scanner Skyscan 1173 to acquire a three dimensional image data of a chicken bone thigh. The thigh was scanned using X-ray voltage of 45 kV and current of 150 μA. The reconstructed images have spatial resolution of 142.50 μm/pixel. Using image processing and analysis e.i segmentation by thresholding the gray values (which represent the pseudo density) and binarizing the images, we were able to visualize each part of the bone, i.e., the cortical and trabecular regions. Total volume of the bone is 4663.63 mm{sup 3}, and the surface area of the bone is 7913.42 mm{sup 2}. The volume of the cortical is approximately 1988.62 mm{sup 3} which is nearly 42.64% of the total bone volume. This pilot study has confirmed that the μCT is capable of quantifying 3D bone structural properties and defining its regions separately. For further development, these results can be improved for understanding the pathophysiology of bone abnormality, testing the efficacy of pharmaceutical intervention, or estimating bone biomechanical properties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AGR-2 TRISO Shadow Imaging Archive

As a part of fuel quality control characterization, backlit shadow images of particles produced by the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-2 irradiation campaign were acquired at Oak Ridge National Laboratory (ORNL). These images may be of use for the development of image processing algorithms with the benchmark values measured at ORNL. This report provides those benchmark values, along with the raw images and data generated by the ORNL shadow imaging process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aerial 3D Building Reconstruction from Drone Imagery (A3DBR) v1

This toolkit is composed of several modules for extracting buildings geometrical and thermal characteristics from RGB and thermal imagery captured using a drone. - Building 3D reconstruction module: leverage a photogrammetry software to construct a 3D point cloud from RGB drone imagery, which is then used in conjunction with image processing and geometric methods to extract building footprint and building height (i.e., 3D model of the building). - Windows to wall ratio estimation module: leverage deep learning semantic segmentation modeling to detect windows on 2D drone RGB images. The detected windows are then projected onto the extracted building 3D model (using building 3D reconstruction module) and their area is computed to obtain window to wall ratio estimation. - Thermal anomalies detection module: leverage image processing and machine learning algorithm to detect on 2D drone thermal images potential thermal anomalies within building's facades and roofs.

Granderson, Jessica↗

THE UNAM-KIAS CATALOG OF ISOLATED GALAXIES

A new catalog of isolated galaxies from the Sloan Digital Sky Survey Data Release 5 (SDSS DR5) is presented. A total of 1520 isolated galaxies were found in 1.4 sr of sky. The selection criteria in this UNAM-KIAS catalog are a variation on the criteria developed by Karachentseva, including full redshift information. Through an image processing pipeline that takes advantage of the high-resolution ({approx}0.''4 pixel{sup -1}) and high dynamic range of the SDSS images, a uniform g-band morphological classification for all these galaxies is presented. We identify 80% (Sa-Sm) spirals (50% later than Sbc types) on one hand, and a scarce population of early-type E (6.5%) and S0 (8%) galaxies amounting to 14.5% on the other hand. This magnitude-limited catalog is {approx}80% complete at 16.5, 15.6, 15.2, 14.6, and 14.4 mag in the ugriz bands, respectively. Some representative physical properties including SDSS magnitudes and color distributions, color-color diagrams, absolute magnitude-color, and concentration-color diagrams as a function of morphological type are presented. The UNAM-KIAS Morphological Atlas is also released along with this paper. For each galaxy of a type later than Sa, a mosaic is presented that includes (1) a g-band logarithmic image, (2) a g-band filtered-enhanced image where a Gaussian kernel of various sizes was applied, and (3) a red giant branch color image from the SDSS database. For E/S0/Sa galaxies, in addition to the images in (1), (2), and (3), plots of r-band surface brightness and geometric profiles (ellipticity {epsilon}, position angle PA, and A{sub 4}/B{sub 4} coefficients of the Fourier series expansions of deviations of a pure ellipse) are provided. The size of the sample, the redshift completeness, the availability of high-quality multicolor photometric data and detailed morphological and spectroscopic information make the UNAM-KIAS catalog of isolated galaxies a suitable sample to address important issues such as (1) comparative studies of environmental effects, (2) constraining the currently competing scenarios of galaxy formation and evolution, (3) the nature and evolution of elliptical and spiral galaxies in the field, (4) the spectral properties of a statistically significant number of isolated galaxies and their evolution as a function of redshift, and (5) the fraction of active galactic nuclei in isolated environments, among other important topics. The optimization and estimation of new structural parameters as well as important information to complement existing ones in other wavelengths is being carried out.

79 ASTRONOMY AND ASTROPHYSICS↗

Some features of photolithography image formation in partially coherent light

The coherent-noise level in projection images of an opaque-screen sharp edge, formed in the model scheme of photolithography system at different degrees of spatial coherence of screen-illuminating light is studied experimentally. The spatial coherence of laser radiation was reduced by applying a specially developed device, used as a separate functional unit in the system model. The smoothing of the spatial fluctuations of radiation intensity caused by the random spatial inhomogeneity of the initial beam intensity in the obtained images is shown to be highly efficient. (imaging and image processing. holography)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An image-based technique to assess the perceptual quality of clinical chest radiographs

Purpose: Current clinical image quality assessment techniques mainly analyze image quality for the imaging system in terms of factors such as the capture system modulation transfer function, noise power spectrum, detective quantum efficiency, and the exposure technique. While these elements form the basic underlying components of image quality, when assessing a clinical image, radiologists seldom refer to these factors, but rather examine several specific regions of the displayed patient images, further impacted by a particular image processing method applied, to see whether the image is suitable for diagnosis. In this paper, the authors developed a novel strategy to simulate radiologists' perceptual evaluation process on actual clinical chest images. Methods: Ten regional based perceptual attributes of chest radiographs were determined through an observer study. Those included lung grey level, lung detail, lung noise, rib-lung contrast, rib sharpness, mediastinum detail, mediastinum noise, mediastinum alignment, subdiaphragm-lung contrast, and subdiaphragm area. Each attribute was characterized in terms of a physical quantity measured from the image algorithmically using an automated process. A pilot observer study was performed on 333 digital chest radiographs, which included 179 PA images with 10:1 ratio grids (set 1) and 154 AP images without grids (set 2), to ascertain the correlation between image perceptual attributes and physical quantitative measurements. To determine the acceptable range of each perceptual attribute, a preliminary quality consistency range was defined based on the preferred 80% of images in set 1. Mean value difference ({mu}{sub 1}-{mu}{sub 2}) and variance ratio ({sigma}{sub 1}{sup 2}/{sigma}{sub 2}{sup 2}) were investigated to further quantify the differences between the selected two image sets. Results: The pilot observer study demonstrated that our regional based physical quantity metrics of chest radiographs correlated very well with their corresponding perceptual attributes. The distribution comparisons, mean value difference estimations, and variance ratio estimations of each physical quantity between sets of images from two different techniques matched our expectation that the image quality of set 1 should be better than that of set 2. Conclusions: The measured physical quantities provide a robust reflection of perceptual image quality in clinical images. The methodology can be readily applied for automated evaluation of perceptual image quality in clinical chest radiographs.

60 APPLIED LIFE SCIENCES↗

Comprehensive experimental investigation on biomass-glass beads binary fluidization: A data set for CFD model validation

Fluidization behavior of biomass and glass beads binary mixtures in a bubbling fluidized bed was experimentally investigated. Mixtures containing different mass fraction of Loblolly Pine white wood and glass beads were fluidized at different fluidization velocities. The particle properties were characterized in a QICPIC that uses a dynamic image processing method to measure both particle size and sphericity. The minimum fluidization velocity was determined using the pressure drop method. An image processing method was developed to capture the dynamic expanded bed height at a very high frequency. The effect of biomass mass fraction and inlet gas velocity on mixing and segregation behavior was studied and analyzed through pressure drop measurements. Pressure drop fluctuations and expanded bed height fluctuations via fast Fourier transform were analyzed and compared. Here, the complete and accurate experimental data reported in this study could provide a benchmark data set for various computational fluid dynamics models validation, calibration, and identification.

42 ENGINEERING↗

Temporal analysis of the coherent properties of optical images of rough nonplanar objects

The possibility of using temporal analysis to find the relation between chromatic properties of probe radiation and coherent properties of the optical images of rough non-planar objects is substantiated. The analysis is based on the use of the time correlation function and on the study of the speckle pattern contrast in the optical images. The conditions are determined under which the different parts of the optical image of an object are coherent, partially coherent and incoherent, while probe radiation is manifested as monochromatic, quasi-monochromatic, and polychromatic. It is shown that these conditions depend considerably on the object surface shape. The use of the temporal analysis for three-dimensional imaging of an object by its planar images and improving the optical image quality by removing its speckle pattern is illustrated by examples. (optical image processing)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contour interpolated radial basis functions with spline boundary correction for fast 3D reconstruction of the human articular cartilage from MR images

Purpose: The aim of this work is to demonstrate a new image processing technique that can provide a “near real-time” 3D reconstruction of the articular cartilage of the human knee from MR images which is user friendly. This would serve as a point-of-care 3D visualization tool which would benefit a consultant radiologist in the visualization of the human articular cartilage. Methods: The authors introduce a novel fusion of an adaptation of the contour method known as “contour interpolation (CI)” with radial basis functions (RBFs) which they describe as “CI-RBFs.” The authors also present a spline boundary correction which further enhances volume estimation of the method. A subject cohort consisting of 17 right nonpathological knees (ten female and seven male) is assessed to validate the quality of the proposed method. The authors demonstrate how the CI-RBF method dramatically reduces the number of data points required for fitting an implicit surface to the entire cartilage, thus, significantly improving the speed of reconstruction over the comparable RBF reconstruction method of Carr. The authors compare the CI-RBF method volume estimation to a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Results: The authors demonstrate how the CI-RBF method significantly reduces the number of data points (p-value < 0.0001) required for fitting an implicit surface to the cartilage, by 48%, 31%, and 44% for the patellar, tibial, and femoral cartilages, respectively. Thus, significantly improving the speed of reconstruction (p-value < 0.0001) by 39%, 40%, and 44% for the patellar, tibial, and femoral cartilages over the comparable RBF model of Carr providing a near real-time reconstruction of 6.49, 8.88, and 9.43 min for the patellar, tibial, and femoral cartilages, respectively. In addition, it is demonstrated how the CI-RBF method matches the volume estimation of a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Furthermore, the performance of the segmentation method used for the extraction of the femoral, tibial, and patellar cartilages is assessed with a Dice similarity coefficient, sensitivity, and specificity measure providing high agreement to manual segmentation. Conclusions: The CI-RBF method provides a fast, accurate, and robust 3D model reconstruction that matches Carr’s RBF method, 3D DOCTOR, and a manual benchmark method in accuracy and significantly improves upon Carr’s RBF method in data requirement and computational speed. In addition, the visualization tool has been designed to quickly segment MR images requiring only four mouse clicks per MR image slice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SpIES: The Spitzer IRAC Equatorial Survey

We describe the first data release from the Spitzer-IRAC Equatorial Survey (SpIES); a large-area survey of ∼115 deg{sup 2} in the Equatorial SDSS Stripe 82 field using Spitzer during its “warm” mission phase. SpIES was designed to probe sufficient volume to perform measurements of quasar clustering and the luminosity function at z ⩾ 3 to test various models for “feedback” from active galactic nuclei (AGNs). Additionally, the wide range of available multi-wavelength, multi-epoch ancillary data enables SpIES to identify both high-redshift (z ⩾ 5) quasars as well as obscured quasars missed by optical surveys. SpIES achieves 5σ depths of 6.13 μJy (21.93 AB magnitude) and 5.75 μJy (22.0 AB magnitude) at 3.6 and 4.5 μm, respectively—depths significantly fainter than the Wide-field Infrared Survey Explorer (WISE). We show that the SpIES survey recovers a much larger fraction of spectroscopically confirmed quasars (∼98%) in Stripe 82 than are recovered by WISE (∼55%). This depth is especially powerful at high-redshift (z ⩾3.5), where SpIES recovers 94% of confirmed quasars, whereas WISE only recovers 25%. Here we define the SpIES survey parameters and describe the image processing, source extraction, and catalog production methods used to analyze the SpIES data. In addition to this survey paper, we release 234 images created by the SpIES team and three detection catalogs: a 3.6 μm only detection catalog containing ∼6.1 million sources, a 4.5 μm only detection catalog containing ∼6.5 million sources, and a dual-band detection catalog containing ∼5.4 million sources.

79 ASTRONOMY AND ASTROPHYSICS↗

The correlation study of parallel feature extractor and noise reduction approaches

This paper presents literature reviews that show variety of techniques to develop parallel feature extractor and finding its correlation with noise reduction approaches for low light intensity images. Low light intensity images are normally displayed as darker images and low contrast. Without proper handling techniques, those images regularly become evidences of misperception of objects and textures, the incapability to section them. The visual illusions regularly clues to disorientation, user fatigue, poor detection and classification performance of humans and computer algorithms. Noise reduction approaches (NR) therefore is an essential step for other image processing steps such as edge detection, image segmentation, image compression, etc. Parallel Feature Extractor (PFE) meant to capture visual contents of images involves partitioning images into segments, detecting image overlaps if any, and controlling distributed and redistributed segments to extract the features. Working on low light intensity images make the PFE face challenges and closely depend on the quality of its pre-processing steps. Some papers have suggested many well established NR as well as PFE strategies however only few resources have suggested or mentioned the correlation between them. This paper reviews best approaches of the NR and the PFE with detailed explanation on the suggested correlation. This finding may suggest relevant strategies of the PFE development. With the help of knowledge based reasoning, computational approaches and algorithms, we present the correlation study between the NR and the PFE that can be useful for the development and enhancement of other existing PFE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system

Purpose: The scanning beam digital x-ray system (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis in multiple planes. This system could be used for image guidance during lung nodule biopsy. However, the reconstructed images suffer from strong out-of-plane artifact due to the small tomographic angle of the system. Methods: The authors propose an out-of-plane artifact subtraction tomosynthesis (OPAST) algorithm that utilizes a prior CT volume to augment the run-time image processing. A blur-and-add (BAA) analytical model, derived from the project-to-backproject physical model, permits the generation of tomosynthesis images that are a good approximation to the shift-and-add (SAA) reconstructed image. A computationally practical algorithm is proposed to simulate images and out-of-plane artifacts from patient-specific prior CT volumes using the BAA model. A 3D image registration algorithm to align the simulated and reconstructed images is described. The accuracy of the BAA analytical model and the OPAST algorithm was evaluated using three lung cancer patients’ CT data. The OPAST and image registration algorithms were also tested with added nonrigid respiratory motions. Results: Image similarity measurements, including the correlation coefficient, mean squared error, and structural similarity index, indicated that the BAA model is very accurate in simulating the SAA images from the prior CT for the SBDX system. The shift-variant effect of the BAA model can be ignored when the shifts between SBDX images and CT volumes are within ±10 mm in the x and y directions. The nodule visibility and depth resolution are improved by subtracting simulated artifacts from the reconstructions. The image registration and OPAST are robust in the presence of added respiratory motions. The dominant artifacts in the subtraction images are caused by the mismatches between the real object and the prior CT volume. Conclusions: Their proposed prior CT-augmented OPAST reconstruction algorithm improves lung nodule visibility and depth resolution for the SBDX system.

60 APPLIED LIFE SCIENCES↗