Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Multivariate statistics applications in phase analysis of STEM-EDS spectrum images

Spectrum imaging (SI) methods are displacing traditional spot analyses as the predominant paradigm for spectroscopic analysis with electron beam instrumentation. The multivariate nature of SI provides clear advantages for qualitative analysis of multiphase specimens relative to traditional gray-scale images acquired with non-spectroscopic signals, where different phases with similar average atomic number may exhibit the same intensity. However, with the improvement in qualitative analysis with the SI paradigm has come a decline in the quantitative analysis of the phases thus identified, since the spectra from individual pixels typically have insufficient counting statistics for proper quantification. The present paper outlines a methodology for quantitative analysis within the spectral imaging paradigm, which is illustrated through X-ray energy-dispersive spectroscopy (EDS) of a multiphase (Pb,La)(Zr,Ti)O{sub 3} ceramic in scanning transmission electron microscopy (STEM). Statistical analysis of STEM-EDS SI is shown to identify the number of distinct phases in the analyzed specimen and to provide better segmentation than the STEM high-angle annular dark-field (HAADF) signal. Representative spectra for the identified phases are extracted from the segmented images with and without exclusion of pixels that exhibit spectral contributions from multiple phases, and subsequently quantified using Cliff-Lorimer sensitivity factors. The phase compositions extracted with the method while excluding pixels from multiple phases are found to be in good agreement with those extracted from user-selected regions of interest, while providing improved confidence intervals. Without exclusion of multiphase pixels, the extracted composition is found to be in poor statistical agreement with the other results because of systematic errors arising from the cross-phase spectral contamination. The proposed method allows quantification to be performed in the presence of discontinuous phase distributions and overlapping phases, challenges that are typical of many nanoscale analyses performed by STEM-EDS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ laser profilometry for material segmentation and digital reconstruction of a multicomponent additively manufactured part

In addition to its ability to produce geometrically complex parts, additive manufacturing offers a unique opportunity to collect data about a component while it is being fabricated. However, there has only been limited effort to characterize parts morphologically and compositionally in situ. In this article, we present a layer-by-layer, laser profilometry-based in situ characterization technique as a method to digitally reconstruct a multi-material part. Data collected by the laser profilometer yields height maps and grayscale images which are voxelized using purpose-built software to volumetrically reconstruct the part. Additionally, the same part was also analyzed using X-ray computed tomography (CT) which was not able to resolve the different compositional regions within the part, but captured the filament morphology. The part was then bisected to compare the digital reconstruction to the actual part morphology and composition. Overall, the digital reconstruction was in good agreement with both the CT and bisected images. Deviations between the digital reconstruction and the CT/bisected images are likely the result of image segmentation settings or material shifts after data was collected. The in situ characterization method demonstrated here sets the stage for real time process monitoring and paves the way for additively manufactured parts that are “born qualified.”

36 MATERIALS SCIENCE↗

Less is More: Bigger Data from Compressive Measurements

Compressive sensing approaches are beginning to take hold in (scanning) transmission electron microscopy (S/TEM) [1,2,3]. Compressive sensing is a mathematical theory about acquiring signals in a compressed form (measurements) and the probability of recovering the original signal by solving an inverse problem [4]. The inverse problem is underdetermined (more unknowns than measurements), so it is not obvious that recovery is possible. Compression is achieved by taking inner products of the signal with measurement weight vectors. Both Gaussian random weights and Bernoulli (0,1) random weights form a large class of measurement vectors for which recovery is possible. The measurements can also be designed through an optimization process. The key insight for electron microscopists is that compressive sensing can be used to increase acquisition speed and reduce dose. Building on work initially developed for optical cameras, this new paradigm will allow electron microscopists to solve more problems in the engineering and life sciences. We will be collecting orders of magnitude more data than previously possible. The reason that we will have more data is because we will have increased temporal/spatial/spectral sampling rates, and we will be able ability to interrogate larger classes of samples that were previously too beam sensitive to survive the experiment. For example consider an in-situ experiment that takes 1 minute. With traditional sensing, we might collect 5 images per second for a total of 300 images. With compressive sensing, each of those 300 images can be expanded into 10 more images, making the collection rate 50 images per second, and the decompressed data a total of 3000 images [3]. But, what are the implications, in terms of data, for this new methodology? Acquisition of compressed data will require downstream reconstruction to be useful. The reconstructed data will be much larger than traditional data, we will need space to store the reconstructions during analysis, and the computational demands for analysis will be higher. Moreover, there will be time costs associated with reconstruction. Deep learning [5] is an approach to address these problems. Deep learning is a hierarchical approach to find useful (for a particular task) representations of data. Each layer of the hierarchy is intended to represent higher levels of abstraction. For example, a deep model of faces might have sinusoids, edges and gradients in the first layer; eyes, noses, and mouths in the second layer, and faces in the third layer. There has been significant effort recently in deep learning algorithms for tasks beyond image classification such as compressive reconstruction [6] and image segmentation [7]. A drawback of deep learning, however, is that training the model requires large datasets and dedicated computational resources (to reduce training time to a few days). A second issue is that deep learning is not user-friendly and the meaning behind the results is usually not interpretable. We have shown it is possible to reduce the data set size while maintaining model quality [8] and developed interpretable models for image classification [9], but the demands are still significant. The key to addressing these problems is to NOT reconstruct the data. Instead, we should design computational sensors that give answers to specific problems. A simple version of this idea is compressive classification [10], where the goal is to classify signal type from a small number of compressed measurements. Classification is a much simpler problem than reconstruction, so 1) much fewer measurements will be necessary, and 2) these measurements will probably not be useful for reconstruction. Other simple examples of computational sensing include determining object volume or the number of objects present in the field of view [11].

Stevens, Andrew↗

Automated Defect Identification for Tri-structural Isotropic Fuels (AUDIT)

During the manufacture of tri-structural isotropic (TRISO)-coated nuclear fuel particles, the potential exists for the formation of internal fissure defects in the uranium oxycarbide (UCO) kernels. These fissures result in a defective fuel particle that can fracture during subsequent fuel processing. Therefore, it is necessary to detect the presence of fissured kernels in a batch to determine if the batch meets specification prior to blending with other batches and upgrading processes. Previous attempts at identifying fissures involved manual inspection of micrographs of UCO fuel kernel cross-sections. This process is tedious, time-consuming and may introduce counting errors making it a good candidate for automation. This work presents a method for the automated detection of fissures in UCO kernels. Image segmentation is used for the extraction of relevant features in the micrographs which then serve as the input to a convolutional neural network used to automatically distinguish between fissured and non-fissured kernels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-G-18A-02: Calibration-Free Combined KV/MV Short Scan CBCT

Purpose: To combine orthogonal kilo-voltage (kV) and Mega-voltage (MV) projection data for short scan cone-beam CT to reduce imaging time on current radiation treatment systems, using a calibration-free gain correction method. Methods: Combining two orthogonal projection data sets for kV and MV imaging hardware can reduce the scan angle to as small as 110° (90°+fan) such that the total scan time is ∼18 seconds, or within a breath hold. To obtain an accurate reconstruction, the MV projection data is first linearly corrected using linear regression using the redundant data from the start and end of the sinogram, and then the combined data is reconstructed using the FDK method. To correct for the different changes of attenuation coefficients in kV/MV between soft tissue and bone, the forward projection of the segmented bone and soft tissue from the first reconstruction in the redundant region are added to the linear regression model. The MV data is corrected again using the additional information from the segmented image, and combined with kV for a second FDK reconstruction. We simulated polychromatic 120 kVp (conventional a-Si EPID with CsI) and 2.5 MVp (prototype high-DQE MV detector) projection data with Poisson noise using the XCAT phantom. The gain correction and combined kV/MV short scan reconstructions were tested with head and thorax cases, and simple contrast-to-noise ratio measurements were made in a low-contrast pattern in the head. Results: The FDK reconstruction using the proposed gain correction method can effectively reduce artifacts caused by the differences of attenuation coefficients in the kV/MV data. The CNRs of the short scans for kV, MV, and kV/MV are 5.0, 2.6 and 3.4 respectively. The proposed gain correction method also works with truncated projections. Conclusion: A novel gain correction and reconstruction method was developed to generate short scan CBCT from orthogonal kV/MV projections. This work is supported by NIH Grant 5R01CA138426-05.

60 APPLIED LIFE SCIENCES↗

Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model

Abstract Background Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.

Dong, Yafei [Yale Biomedical Imaging Institute Yal↗

Following Dynamic Processes by X-ray Tomographic Microscopy with Sub-second Temporal Resolution

Several non-destructive imaging techniques offer the possibility to observe rapid phenomena in real time, yet most of these techniques fail when it comes to bulky samples and micrometer precision in three dimensions. Therefore there is clearly a need to develop approaches that address such conditions. We identified the large potential that lies in synchrotron-based x-rays as a probe and developed a direct-space tomographic instrument suitable to provide sub-second temporal resolution with several-micrometers spatial resolution. Selected applications from the field of biology and material science are shown in order to demonstrate the unique capabilities in generating three-dimensional images with very high quality making image segmentation and analysis possible for samples that could, until now, only be studied in two dimensions due to the occurrence of rapid structural changes.

07 ISOTOPE AND RADIATION SOURCES↗

Tracking Dendritic Growth in Hydrogen-Based Hematite Reduction via Computer Vision

The reduction of hematite to metallic iron using hydrogen (H2) as a reducing agent presents a promising pathway for decarbonizing steel production. In this study, we employ a combination of in situ confocal scanning laser microscopy (CSLM) and advanced computer vision techniques to quantitatively analyze dendritic growth of ferrite during H2-based reduction of iron oxide at high temperatures. A workflow integrating Watershed Image Segmentation (WIS) and Lucas-Kanade Optical Flow (LKOF) is developed to extract both global and local kinetic information from time-resolved micrograph sequences. H2 reduction experiments conducted at 1400 degrees C and 1500 degrees C demonstrate a clear correlation between temperature and reduction rate, as evidenced by accuracy of fitted Johnson-Mehl-Avrami-Kolmogorov (JMAK) parameters. Optical flow analysis further elucidates the anisotropic and branched nature of dendritic growth, providing spatially resolved velocity fields that correlate well with global transformation kinetics. The proposed methodology demonstrates strong agreement with experimental measurements and literature values, offering a robust framework for automated image-based analysis to study kinetics through microstructural evolution in the reduction of iron ore, and likely other reaction-diffusion phenomena.

08 HYDROGEN↗

Active Breathing Control in Combination With Ultrasound Imaging: A Feasibility Study of Image Guidance in Stereotactic Body Radiation Therapy of Liver Lesions

Purpose: Accurate tumor positioning in stereotactic body radiation therapy (SBRT) of liver lesions is often hampered by motion and setup errors. We combined 3-dimensional ultrasound imaging (3DUS) and active breathing control (ABC) as an image guidance tool. Methods and Materials: We tested 3DUS image guidance in the SBRT treatment of liver lesions for 11 patients with 88 treatment fractions. In 5 patients, 3DUS imaging was combined with ABC. The uncertainties of US scanning and US image segmentation in liver lesions were determined with and without ABC. Results: In free breathing, the intraobserver variations were 1.4 mm in left-right (L-R), 1.6 mm in superior-inferior (S-I), and 1.3 mm anterior-posterior (A-P). and the interobserver variations were 1.6 mm (L-R), 2.8 mm (S-I), and 1.2 mm (A-P). The combined uncertainty of US scanning and matching (inter- and intraobserver) was 4 mm (1 SD). The combined uncertainty when ABC was used reduced by 1.7 mm in the S-I direction. For the L-R and A-P directions, no significant difference was observed. Conclusion: 3DUS imaging for IGRT of liver lesions is feasible, although using anatomic surrogates in the close vicinity of the lesion may be needed. ABC-based breath-hold in midventilation during 3DUS imaging can reduce the uncertainty of US-based 3D table shift correction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and evaluation of the MAMMI dedicated breast PET

Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV-750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

WE-AB-BRA-04: Evaluation of the Tumor Registration Error in Biopsy Procedures Performed Under Real Time PET/CT Guidance

Purpose: PET/CT guidance is used for biopsies of metabolically active lesions, which are not well seen on CT alone or to target the metabolically active tissue in tumor ablations. It has also been shown that PET/CT guided biopsies provide an opportunity to verify the location of the lesion border at the place of needle insertion. However the error in needle placement with respect to the metabolically active region may be affected by motion between the PET/CT scan performed at the start of the procedure and the CT scan performed with the needle in place and this error has not been previously quantified. Methods: Specimens from 31 PET/CT guided biopsies were investigated and correlated to the intraoperative PET scan under an IRB approved HIPAA compliant protocol. For 4 of the cases in which larger motion was suspected a second PET scan was obtained with the needle in place. The CT and the PET images obtained before and after the needle insertion were used to calculate the displacement of the voxels along the needle path. CTpost was registered to CTpre using a free form deformable registration and then fused with PETpre. The shifts between the PET image contours (42% of SUVmax) for PETpre and PETpost were obtained at the needle position. Results: For these extreme cases the displacement of the CT voxels along the needle path ranged from 2.9 to 8 mm with a mean of 5 mm. The shift of the PET image segmentation contours (42% of SUVmax) at the needle position ranged from 2.3 to 7 mm between the two scans. Conclusion: Evaluation of the mis-registration between the CT with the needle in place and the pre-biopsy PET can be obtained using deformable registration of the respective CT scans and can be used to indicate the need of a second PET in real-time. This work is supported in part by a grant from Biospace Lab, S.A.

60 APPLIED LIFE SCIENCES↗

The impact of carbonation on bulk and ITZ porosity in microconcrete materials with fly ash replacement

Scanning electron microscopy was used to evaluate the porosity patterns found in microconcrete materials to better understand the gaseous diffusion pathways and reaction of CO{sub 2} within the bulk cement paste and interfacial transition zone (ITZ) of microconcrete materials containing different fly ash replacement types. Image segmentation was applied to evaluate the porosity as a function of distance from an exposed surface in the bulk cement paste and from aggregate boundaries in the ITZ in both carbonated and non-carbonated microconcrete materials. The ITZ region remained more porous compared to the bulk cement paste for all microconcrete types after carbonation despite a change in the porosity profile across the ITZ region. Results indicate that both the carbonation reaction capacity and porosity before carbonation impact the decrease in porosity observed as a result of carbonation in the ITZ and bulk cement paste regions.

36 MATERIALS SCIENCE↗

Cross-scale sensing of field-level crop residue cover: Integrating field photos, airborne hyperspectral imaging, and satellite data

Conservation tillage practices can bring benefits to agricultural sustainability. Accurate spatial and temporal resolved information of field-scale crop residue cover, which reflects tillage intensity, is highly valuable for evaluating the outcomes of government conservation programs and voluntary ecosystem service markets, as well as facilitating agroecosystem modeling to quantify cropland biogeochemical processes. Remote sensing has the potential to cost-effectively detect crop residue cover, however, existing regional-scale studies were limited by insufficient ground truth data, scale mismatch between coarse satellite pixels and ground data, and the lack of key spectral data for detecting crop residues. Therefore, this study developed an innovative cross-sensing framework to integrate proximal sensing, airborne hyperspectral imaging, and satellite Earth Observation through deep learning to quantify field-level crop residue cover fractions at the regional scale. Specifically, we have collected intensive ground orthographic photos and conducted airborne hyperspectral surveys at corn and soybean fields of Champaign and nearby counties in Illinois, the heartland of the U.S. Corn Belt. Through semi-automatic labeling aided by ResNet-50 and superpixel image segmentation, we obtained 6719 records of ground residue fractions. With these ground data, we developed the 1-dimensional convolution neural network (CNN) model using airborne hyperspectral reflectance, which has 0.5m spatial resolution and 3–5 nm spectral resolution from 400 to 2400 nm, to predict residue fractions. By applying the CNN model to airborne pixels, we augmented “ground truth” data of crop residues and further combined them with Harmonized Landsat and Sentinel-2 (HLS) satellite data to quantify regional residue fractions at 30 m resolution. Results show that airborne hyperspectral imagery with CNN can accurately detect residue fractions (R 2 = 0.82, relative RMSE = 11.73%) to effectively generate quasi “ground truth” data to support satellite upscaling to all fields. With independent ground data for testing, we found that the ground-airborne-satellite integrative framework achieved better predictions in estimating crop residue cover (R 2 = 0.67, relative RMSE = 17.53%) than the conventional ground-satellite upscaling (R 2 = 0.22, relative RMSE = 32.09%). Here we also found that the shortwave infrared wavelengths, particularly 2100–2300 nm, are vital for predicting crop residue cover. Sentinel-2 and Landsat-8 data have a comparable capability to track residue fractions due to similar shortwave infrared wavelengths. This study highlights the high accuracy of hyperspectral imaging to detect agroecosystem tillage management practices and the advantages of cross-scale sensing to cost-effectively integrate multi-source data to quantify field-level agroecosystem variables across scales.

60 APPLIED LIFE SCIENCES↗

Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure

Swings in pH can be achieved by electrically polarizing a bipolar membrane (BPM) to drive water dissociation at the BPM junction for electrochemical conversion and separation processes. BPM junction design is critical to tailor performance for specific applications; however, characterization techniques capable of resolving the nanometer scale physical structure of the junction are limited. We present sample preparation, imaging, and analysis workflows that are adaptable to a variety of BPM junction architectures. Atomic force microscopy produces BPM junction images with nanometer scale lateral resolution for samples with and without a graphene oxide water dissociation catalyst in the junction. Subsequent image segmentation and analysis quantify line edge roughness and catalyst layer thickness as descriptors of junction structure. Comparison of pre- and post-electrodialysis junctions suggests electric field-induced alignment of catalyst particles during electrodialysis. This characterization workflow can inform manufacturing protocols, computational modeling, and failure mode analysis for next-generation BPMs.

97 MATHEMATICS AND COMPUTING↗

Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy

Purpose: Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused by patient motion and dynamic beam delivery. Methods: The 4DTPS integrates data interfaces to 4D computed tomography (4DCT), deformable image registration and clinically used motion monitoring devices. The authors implemented a novel data model for 4D image segmentation using Boolean mask volume datasets and developed an algorithm propagating a manually contoured reference contour dataset to all 4DCT phases. They further included detailed treatment simulation and dose reconstruction functionality, based on the irregular patient motion and the temporal structure of the beam delivery. The treatment simulation functionality was validated against experimental data from irradiation of moving radiographic films in air, 3D moving ionization chambers in a water phantom, and moving cells in a biological phantom with a scanned carbon ion beam. The performance of the program was compared to results obtained with predecessor programs. Results: The measured optical density distributions of the radiographic films were reproduced by the simulations to (-2 {+-} 12)%. Compared to earlier versions of the 4DTPS, the mean agreement improved by 2%, standard deviations were reduced by 7%. The simulated dose to the moving ionization chambers in water showed an agreement with the measured dose of (-1 {+-} 4)% for the typical beam configuration. The mean deviation of the simulated from the measured biologically effective dose determined via cell survival was (617 {+-} 538) mGy relative biological effectiveness corresponding to (10 {+-} 9)%. Conclusions: The authors developed a research 4DTPS suitable for realistic treatment planning on patient data and capable of simulating dose delivery to a moving patient geometry for scanned ion beams. The accuracy and reliability of treatment simulations improved considerably with respect to earlier versions of the 4DTPS.

60 APPLIED LIFE SCIENCES↗

Exploring Physics of Ferroelectric Domain Walls in Real Time: Deep Learning Enabled Scanning Probe Microscopy

The functionality of ferroelastic domain walls in ferroelectric materials is explored in real-time via the in situ implementation of computer vision algorithms in scanning probe microscopy (SPM) experiment. The robust deep convolutional neural network (DCNN) is implemented based on a deep residual learning framework (Res) and holistically nested edge detection (Hed), and ensembled to minimize the out-of-distribution drift effects. The DCNN is implemented for real-time operations on SPM, converting the data stream into the semantically segmented image of domain walls and the corresponding uncertainty. Further the pre-defined experimental workflows perform piezoresponse spectroscopy measurement on thus discovered domain walls, and alternating high- and low-polarization dynamic (out-of-plane) ferroelastic domain walls in a PbTiO 3 (PTO) thin film and high polarization dynamic (out-of-plane) at short ferroelastic walls (compared with long ferroelastic walls) in a lead zirconate titanate (PZT) thin film is reported. This work establishes the framework for real-time DCNN analysis of data streams in scanning probe and other microscopies and highlights the role of out-of-distribution effects and strategies to ameliorate them in real time analytics.

36 MATERIALS SCIENCE↗

Using X-ray radiography to study oxygen flow in a proton exchange membrane electrolyzer operating under balanced pressure conditions

Of the various water electrolyzer technologies, the proton exchange membrane electrolyzer (PEMWE) is one of the best solutions for producing clean hydrogen without releasing CO 2 . In order to allow for widespread use of clean hydrogen, it is necessary to decrease its cost, which is intrinsically related to system operation. Current PEMWE plants operate in differential mode, directly pressurizing hydrogen and benefiting from thermodynamic compression, which increases overall system efficiency. However, high differential pressure above 30 bar can cause membrane stress, resulting in membrane creeping and failure. Pressurizing the water and operating at balanced pressure allows hydrogen to be produced at higher pressures while preserving the integrity of the membrane and porous layers. Nevertheless, the impact of pressurizing water on PEMWE performance must be better understood to maximize performance under balanced pressure conditions. Here, this study examined the impact of water pressure on two-phase flow. A high-pressure electrolyzer setup was developed to perform operando X-ray radiography and examine oxygen transport with high temporal resolution. The imaging segmentation process, developed to capture bubble properties in the channel, was applied to a specific experiment. The results clearly showed that as pressure increased up to 30 bars, the initial bubbly flow transitioned to slug flow, which led to channel saturation with oxygen. This work demonstrates that two-phase flow in an electrolyzer can be studied using X-ray radiography, which has the advantages of fast measurements and the ability to probe dense materials, such as those required for pressurized electrolyzers.

Balanced high pressure operation↗