At least 235 records · Page 13

Assessing high fidelity multi-component models to facilitate safeguards at Gas Centrifuge Enrichment Plants

We report that the International Atomic Energy Agency (IAEA) inspectors routinely carry out environmental sampling (ES) as a verification method. Collection of environmental swipe samples at various locations in Gas Centrifuge Enrichment Facilities (GCEPs) is an important process in detecting misuse of a declared facility and possibly the existence of undeclared nuclear material. These samples are measured for isotopic composition in uranium containing particles by Thermal Ionization Mass Spectrometry (TIMS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Even though ES is highly effective in detecting the absolute value of enrichments and their deviations from the declared values, it cannot explain the cause of those changes. Several potential explanations can serve as possibilities for particles detected above or other than the declared enrichment. These include normal and non-malicious events such as the design of the enrichment cascades, unintentional failures of the machines, or overshoot during startup of a cascade. It can also be the result of deliberate misuse by the facility operators. The primary objective of this work is to understand how these factors affect the enrichments produced by a cascade and quantify anticipated multi-isotopic concentrations for each case. The following methodology is employed to determine signatures at a particular facility. 1) Utilize a new two-dimensional multi-component diffusion code to obtain centrifuge performance data and use that information to design and perform cascade analysis. Compare and contrast the results with previous 1-D radially averaged solutions from the Pancake code. 2) Design a GCEP cascade with the production goal of 19.75% 235 U for each set of machine data above. Investigate two cascade scenarios that include enrichment of natural uranium (NU) feed to 19.75% 235U in a single cascade compared to a two-step process of NU to 5% and then 5% to 19.75%. 3) Simulate the intentional vs. unintentional off-normal scenarios in the cascades to assess the differences in isotopic concentrations. A non-ideal squared-off cascade model developed at the University of Virginia is used to calculate flow rates and isotopic concentrations of the process gas. The analysis is performed using the Rome machine model operated at 600 m/s rotor speed. The upper and lower bounds of normal and abnormal enrichments in a typical facility are used in conjunction with ES results to understand the root causes of such observations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cs absorption capacity and selectivity of crystalline and amorphous Hf and Zr phosphates

Removal of radioactive Cs from sodium-rich solutions is a technical challenge that goes back to post World War II nuclear waste storage and treatment; and interest in this topic was reinvigorated by the Fukushima-Daiichi nuclear power plant disaster, 10 years ago. Since the 1960's there has been considerable focus on layered Zr phosphates as robust inorganic sorbents for separation of radionuclides such as Cs. Here we present synthesis and characterization, and direct comparison of Cs sorption capacity and selectivity of four related materials: 1) crystalline α-Zr phosphate and α-Hf phosphate, and 2) amorphous analogues of these. Powder X-ray diffraction, thermogravimetry, solid-state 31P magic angle spinning nuclear magnetic resonance (MAS-NMR) spectroscopy, and compositional analysis (inductively coupled plasma optical emission spectroscopy and mass spectroscopy, ICP OES and ICP MS) provided formulae; respectively M(HPO4)2∙1H2O and M(HPO4)2∙4H2O (M = Hf, Zr) for crystalline and amorphous analogues. Maximum Cs loading, competitive Cs-Na selectivity and maximum Cs-Na loading followed by the above characterizations plus 133Cs MAS-NMR spectroscopy revealed that amorphous analogues are considerably better Cs-sorbents (based on maximum Cs-loading and selectivity over Na) than the well-studied crystalline Zr-analogue. Additionally, crystalline α-Hf phosphate is better Cs-sorbent than crystalline α-Zr phosphate. All these studies consistently show that Hf phosphate is less crystallize than Zr phosphate, when obtained under similar or identical synthesis conditions. We attribute this to lower solubility of Hf phosphate compared to Zr phosphate, preventing ‘defect healing’ during the synthesis process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variations in GARS powder microstructure as a function of powder chemistry and particle size

The properties of metal produced through powder metallurgy depends on the feedstock used. Powders produced via gas atomization reaction synthesis (GARS) are used to produce oxide dispersion strengthened alloys. The desired powder size range can vary for each consolidation technique. However, powder microstructure also can vary with powder particle size, which in turn can impact the microstructure and properties of the consolidated parts. In this study, GARS powders are characterized via inductively coupled plasma mass spectroscopy, inert gas fusion, and high-resolution x-ray diffraction to determine variations in elemental and phase compositions. Transmission electron microscopy was used to understand microstructure variations as a function of chemistry and size. Across the three batches tested intermetallic content was 0.73–1.35 wt% in the 0-20 μm powder batch and increased to 2.46–3.80 wt% in the coarse 45-106 μm batch. Across all batches, volume percent of surface oxidation decreased with powder diameter, with volume percents within the range of 0.75–1.2 % across 10 μm powder particles, and below 0.4 % across coarse powder particles approximately 100 μm in diameter. These observations were supported by inert gas fusion measurements. However, the oxide layer was thicker in coarse powder particles due to a slower cooling rate. Increasing oxygen content in atomization gas to 2000 ppm and adding yttrium increased both the surface oxidation content and yttrium intermetallic content. Lastly, intermetallic phases within the powder coarsened with powder size. Intermetallic morphology changed from fine spherical intermetallic and columnar dendritic growth to a cellular structure with finer spherical intermetallic, to coarse irregular intermetallic and intermetallic along grain boundaries as a result of slower cooling rate and solidification rate in coarse powder particles. Furthermore, the addition of zirconium does not appear to significantly change intermetallic morphology, but the composition changed from a Y-Fe rich intermetallic to a Y-Zr-Fe intermetallic.

42 ENGINEERING↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

The role of dissolved pyrogenic carbon from biochar in the sorption of As(V) in biogenic iron (oxyhydr)oxides

Water contamination by arsenic (As) affects millions of people around the world, making techniques to immobilize or remove this contaminant a pressing societal need. Biochar and iron (oxyhydr)oxides [in particular, biogenic iron (oxyhydr)oxides (BIOS)] offer the possibility of stabilizing As in remediation systems. However, little is known about the potential antagonism in As sorption generated by the dissolved organic carbon (DOC) from biochar, or whether DOC affects how As(V) interacts with BIOS. For this reason, our objectives were to evaluate the i) As(V) sorption potential in BIOS when there is presence of DOC from pyrolyzed biochars at different temperatures; and ii) identify whether the presence of DOC alters the surface complexes formed by As(V) sorbed in the BIOS. We conducted As(V) sorption experiments with BIOS at circumneutral pH conditions and in the presence of DOC from sugarcane (Saccharum officinarum) straw biochar at pyrolyzed 350 (BC350) and 750 °C (BC750). The As(V) content was quantified by inductively coupled plasma mass spectrometry, and the BIOS structure and As(V) sorption mechanisms were investigated by X-ray absorption spectroscopy. In addition, the organic moieties comprising the DOC from biochars were investigated by attenuated total reflectance Fourier transform infrared spectroscopy. The addition of DOC did not change the biomineral structure or As(V) oxidation state. The presence of DOC, however, reduced by 25 % the sorption of As(V), with BC350 being responsible for the greatest reduction in As(V) sorption capacity. Structural modeling revealed As(V) predominantly formed binuclear bidentate surface complexes on BIOS. The presence of DOC did not change the binding mechanism of As(V) in BIOS, suggesting that the reduction of As(V) sorption to BIOS was due to site blocking. In conclusion, our results bring insights into the fate of As(V) in surface waters and provide a basis for understanding the competitive sorption of As(V) in environments with biochar application.

54 ENVIRONMENTAL SCIENCES↗

Environmental impact of solution pH on the formation and migration of iron colloids in deep subsurface energy systems

Deep subsurface stimulation processes often promote fluid-rock interactions that can lead to the formation of small colloidal particles that are suspected to migrate through the rock matrix, partially or fully clog pores and microfractures, and promote the mobilization of contaminants. Thus, the goal of this work is to understand the geochemical changes of the host rock in response to reservoir stimulation that promote the formation and migration of colloids. Two different carbonate-rich shales were exposed to different solution pHs (pH = 2 and 7). In this study, iron and other mineral transformations at the shale-fluid interface were first characterized by synchrotron-based XRF mapping. Then, colloids that were able to migrate from the shale into the bulk fluid were characterized by synchrotron-based extended X-ray absorption structure (EXAFS), scanning electron microscopy (SEM), and single-particle inductively coupled plasma time-of-flight mass spectrometry (sp-icpTOF-MS). When exposed to the pH = 2 solution, extensive mineral dissolution and secondary precipitation was observed; iron-(oxyhydr)oxide colloids colocated with silicates were observed by SEM at the fluid-shale interfaces, and the mobilization of chromium and nickel with these iron colloids into the bulk fluid was detected by sp-icpTOF-MS. Iron EXAFS spectra of the solution at the shale-fluid interface suggests the rapid (within minutes) formation of ferrihydrite-like nanoparticles. Thus, we demonstrate that the pH neutralization promotes the mobilization of existing silicate minerals and the rapid formation of new iron colloids. These Fe colloids have the potential to migrate through the shale matrix and mobilize other heavy metals (such as Cr and Ni, in this study) and impacting groundwater quality, as well produced waters from these hydraulic fracturing operations.

54 ENVIRONMENTAL SCIENCES↗

Trace metal transfer to passerines inhabiting wastewater treatment wetlands

Wastewater treatment wetlands are cost-effective strategies for remediating trace metals in industrial effluent. However, biogeochemical exchange between wastewater treatment wetlands and adjacent environments provides opportunities for trace metals to cycle in surrounding ecosystems. The transfer of trace metals to wildlife inhabiting treatment wetlands must be considered when evaluating wetland success. Using passerine birds as bioindicators, we conducted a multi-tissue analysis to investigate the mobilization of zinc, copper, and lead derived from wastewater to terrestrial wildlife in treatment wetlands and surrounding habitat. In addition, we evaluate the strength of relationships between metal concentrations in non-lethal (blood and feathers) and lethal (muscle and liver) sample types for estimation of toxicity risk. From July 2020 to August 2021, 177 passerines of seven species were captured at two wetlands constructed to treat industrial wastewater and two reference wetlands in the coastal plain of South Carolina. Feather, blood, liver, and muscle samples from each bird were analyzed for fourteen metals using inductively coupled plasma mass spectrometry and direct mercury analysis. Passerines inhabiting wastewater treatment wetlands accumulated higher concentrations of zinc in liver, copper in blood, and lead in feathers than passerines in reference wetlands, but neither blood nor feather concentrations were correlated with internal tissue concentrations. Of all the detected metals, only mercury in the blood showed a strong predictive relationship with mercury in internal tissues. This study indicates that trace metals derived from wastewater are bioavailable and exported to terrestrial wildlife and that passerine biomonitoring is a valuable tool for assessing metal transfer from treatment wetlands. Furthermore, regular blood sampling can reveal proximate trace metal exposure but cannot predict internal body burdens for most metals.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Isolating intermediate Mg 11 Cu 6 Al 12 phase in ternary Mg-Cu-Al alloy by electrolytic dealloying

While dealloying is widely used to create nanoporous materials, it has rarely been employed to isolate difficult-to-synthesize intermediate phases. Here, in this work, we show how air-free, electrolytic dealloying at room temperature can be used to isolate the ternary intermetallic Mg 11 Cu 6 Al 12 phase. We create a ternary Mg-Cu-Al parent alloy containing the Mg 11 Cu 6 Al 12 compound and other phases, then subsequently remove these other phases via electrolytic dealloying to isolate the Mg 11 Cu 6 Al 12 phase. Isolated Mg 11 Cu 6 Al 12 phase exhibits ≈1 μm diameter rod-shaped microstructure. Phase and chemical analysis conducted using various techniques, including inductively coupled plasma and lab and synchrotron-based X-ray diffraction, show minimal impurities. This new approach to isolate the Mg 11 Cu 6 Al 12 phase can unlock its use in fundamental research and can be applied to other difficult-to-synthesize intermetallic compounds.

36 MATERIALS SCIENCE↗

Bioleaching ion-unexchangeable rare earth in ion-adsorption type rare earth waste tailing

Ion-adsorption type rare earth ores (IREO) in China serve as the primary source of medium and heavy rare earth globally. With the rapidly growing demand for rare earth elements (REEs) and the dwindling supply of premium IREO, enhancing the recovery of REEs, especially the ion-unexchangeable REEs with ultra-low content and ambiguous speciation from IREO or its tailing, has become a critical trend and challenge. Here, this study identified the occurrences of ion-unexchangeable REEs, primarily detected in Fe-enriched minerals, xenotime, and monazite of IREO using TESCAN integrated mineral analyzer (TIMA) and laser ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) analysis. To extract these elusive REEs, a bioleaching technique utilizing Aspergillus niger (A. niger) metabolites was proposed, achieving a leaching yield of 31.4 wt%. Complementary sequential chemical extraction methods (SCEM), X-ray photoelectron spectroscopy (XPS), and density functional theory (DFT) calculations further elucidate the underlying mechanism, involving the carboxylic acid produced by the metabolic process of microbes that dissolves goethite by disrupting Fe—O bonds and liberating REEs, which complexed with carboxylate (R—COO—), to promote further dissolution. This work offers insight into enhancing the recovery of ion-unexchangeable REEs from IREO or its tailing, paving the way for sustainable and efficient rare earth mining practices.

42 ENGINEERING↗

Innovative recycling of high purity silver from silicon solar cells by acid leaching and ultrasonication

Precious and scarce silver (Ag) is used as a front electrical contact in silicon solar panels. With massive amounts of solar panel waste coming to end-of-life, it is imperative to recover all the Ag from these modules. In this paper, we propose a novel method to easily reclaim Ag from end-of-life silicon solar cells using low concentration sulfuric acid (H 2 SO 4 ) leaching followed by ultrasonication. Our process simplifies the Ag recycling procedure by directly recovering the Ag contacts from solar cells, eliminating the need for secondary precipitation/electrodeposition. First, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS) was used to study the leaching and ultrasonication process on rejected solar wafers. Next, a solar panel from landfill was heated in a furnace to burn off the polymer encapsulant. The silicon wafers were then collected from the burning process and leached in 2 M H 2 SO 4 at two different shaking speeds for 48 hours at room temperature. Finally, the end-of-life silicon wafer pieces were collected, sonicated in water, and then the sonication water was centrifuged to show a proof-of-concept to recover the Ag contacts. Inductively coupled plasma optical emission spectroscopy (ICPOES) is used to monitor dissolved elements in the leachate as a function of time and shaking speed. XPS is used to evaluate the composition of the silicon cell wafer surface before and after H 2 SO 4 leaching. SEM is used to image the recovered Ag contacts morphology and EDX confirms the recovered particles contain high amounts of Ag. Furthermore, a proposed schematic illustrates the authors’ hypothesis for the peeling mechanism.

14 SOLAR ENERGY↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid analysis of 237 Np and Pu isotopes in unseparated sample matrices using ICP-MS/MS

Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is an emerging technique for measuring actinide isotopes when assessing pre- and post- detonation nuclear material. In this study, ICP-MS/MS was investigated for direct Np and Pu quantitation in unseparated, dissolved bulk soil matrices. To achieve this, purified nitric oxide (NO) was investigated for the reactivity of Th, Np, U, Pu, Am, and Cm. Purifying NO prior to the collision reaction cell (CRC) results in increased sensitivity and allows for higher gas flows to be utilized for the removal of interferences. Here, the interference from uranium hydrides was mitigated to less than 3.85 x 10 -11 . This method was demonstrated on standard reference materials which were measured for 237 Np and 238,239,240 Pu in dilute sample digestions. The 238 Pu measurement was validated by spiking into a standard reference material and was accurately measured with an excess of 85000 of 238 U.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid isotopic analysis of uranium microparticles via SP-ICP-TOF-MS

Inductively coupled plasma – time-of-flight – mass spectrometry (ICP-TOF-MS) was employed for the isotopic analysis of uranium particles of varying 235 U enrichment levels. Here, a single particle (SP)-based introduction scheme was employed such that individual particles, in a suspension, were analyzed. The uranium oxide microparticles were comprised of depleted uranium (DU, 235 U/ 238 U of 0.0017316(14)), natural uranium (NU, 235 U/ 238 U of 0.0072614(39)), and low enriched uranium (LEU, 235 U/ 238 U of 0.051025(15)). The percent relative difference of the SP-ICP-TOF-MS measured isotopic ratios compared to the expected values for the DU, NU, and LEU particle populations were 8.75, 0.12, and 1.23 %, respectively. After characterization, the DU and NU particles were doped within a complex sample matrix (Arizona Test Dust) containing Fe, Ti, Al, and Si particles, among others. Then, the suspension was analyzed via SP-ICP-TOF-MS and the detected particles were classified as DU or NU based on their measured 235 U/ 238 U ratio. In the same analysis, the matrix particles (i.e., Al, Fe, and Ti) were detected, demonstrating the simultaneous nuclide detection provided by the measurement platform. The presented SP-ICP-TOF-MS methodology for uranium particle characterization proved to be a high throughput method for detecting and isotopically discerning uranium particles with varying enrichment levels, in a complex matrix.

Stanberry, Jordan S. [Oak Ridge National Laborator↗

The need for speed – Burnup determination of spent nuclear fuel

Here we present the application of a novel analytical approach for high-speed evaluation of burn-up in spent nuclear fuel. This automated online separation–direct analysis method, which simultaneously measures the isotopic compositions and concentrations of Nd, Pu, and U using isotope dilution-inductively coupled plasma mass spectrometry, enables the determination of burnup in as little as 4.5 h per sample with expanded uncertainties as low as 1.2% using as little as 1µg of fuel. We compare the determined burn-up values, sample requirements, and analysis times with an ultra-high precision, in-house developed, methodology which employs multiple analytical techniques to measure the isotopic compositions and concentrations of Nd, Pu, and U yielding burn-up values with expanded uncertainties as low as 0.49% at the 95% confidence level, the lowest reported to date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Femtosecond Laser Desorption Postionization MS vs ToF-SIMS Imaging for Uncovering Biomarkers Buried in Geological Samples

The study of lipid molecular fossils by traditional biomarker analysis requires bulk sample crushing, followed by solvent extraction, and then the analysis of the extract by gas chromatography-mass spectrometry (GC–MS). This traditional analysis mixes all organic compounds in the sample regardless of their origins, with a loss of information on the spatial distribution of organic molecules within the sample. These shortcomings can be overcome using the chemical mapping of intact samples. Spectroscopic techniques such as UV fluorescence or Raman spectroscopy, laser ablation inductively coupled plasma mass spectrometry, and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are among those elemental and molecular mapping techniques. This study employed femtosecond (fs) laser ablation combined with single-photon ionization, a method called fs-laser desorption postionization mass spectrometry (fs-LDPI-MS). In this work, a pulsed ~75 fs, 800 nm laser was used to ablate the geological sample, which was then photoionized after a few microseconds by a pulsed 7.9 eV vacuum ultraviolet laser. An organic carbon-rich geological sample was used for this study to map hydrocarbon biomarkers in sediments that were previously studied by GC–MS. The petrography of this sample was examined by optical and fluorescence microscopy. It is demonstrated here that fs-LDPI-MS combined with petrography for multimodal imaging can expose buried compounds within the sample via in situ layer removal. When used in conjunction with traditional organic geochemical analysis, this method has the potential to determine the spatial distribution of organic biomarkers in geological material. Finally, fs-LDPI-MS imaging data are compared with ToF-SIMS imaging that is commonly used for such studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrating Flow Imaging Analysis and Single-Particle ICP-TOFMS for Comprehensive Micro- and Nanoplastic Characterization

Flow imaging analysis (FIA), provides composition-agnostic morphological characterization. These measurements of particle size and shape are valuable to mass-based analysis, such as single particle inductively coupled plasma time-of-flight mass spectrometry (sp-ICP-TOFMS), which provides quantitative data on elements within particles. Using these two methods together enables informed use of geometric assumptions required by sp-ICP-TOFMS, as particle mass is typically converted to a particle diameter using assumed-spherical geometry. To validate this concept, parallel measurements to determine particle diameters were performed by FIA and sp-ICP-TOFMS on four particle suspensions: 300 nm polystyrene Eu-doped nanoparticles, 1 μm Fe-rich beads, 3 μm four element calibration polystyrene beads and 5 μm polystyrene beads. The Fe-particles obtained the highest percent difference from the manufacturer’s nominal diameter, as the mean diameter obtained by FIA was overestimated by 21% and sp-ICP-TOFMS underestimated the mean diameter by 20.7%. Two types of particles were selected to test the effect of varying the particle number concentrations (PNC) on sizing accuracy, and both methods accurately sized each particle population at the PNC expected. Single particle analysis of carbon has continued to be a popular research topic, with direct applications to environmental pollutants in terms of nano- and micro- plastics. Real-world plastic particles were studied, and FIA’s measured circularity values demonstrated that the particles deviated from spherical geometries, therefore sp-ICP-TOFMS data should be interpreted as mass-based rather than size-based. Combining these techniques enables improved interpretation of particle populations and evaluation of particle sizes.

Szakas, Sarah [ORNL] (ORCID:0000000241332197)↗