Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared Sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

BLOC Site - ASSIST Thermodynamic retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Rochette et al. 2009) operated by NOAA Physical Sciences Laboratory on Block Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Radiances are noise-filtered but not averaged in time to minimize errors due to non-uniform clouds. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the ASSIST housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

Applying Infrared Thermography as a Method for Online Monitoring of Turbine Blade Coolant Flow

As gas turbine engine manufacturers strive to implement condition-based operation and maintenance, there is a need for blade monitoring strategies capable of early fault detection and root-cause determination. Given the importance of blade cooling flows to turbine blade health and longevity, there is a distinct lack of methodologies for coolant flowrate monitoring. The present study addresses this identified opportunity by applying an infrared thermography system on an engine-representative research turbine to generate data-driven models for prediction of blade coolant flowrate. Thermal images were used as inputs to a linear regression and regularization algorithm to relate blade surface temperature distribution with blade coolant flowrate. Additionally, this study investigates how coolant flowrate prediction accuracy is influenced by the number and breadth of diagnostic measurements. Here, the results of this study indicate that a source of high-fidelity training data can be used to predict blade coolant flowrate within about six percent error. Furthermore, identification of prioritized sensor placement supports application of this technique across multiple sensor technologies capable of measuring blade surface temperature in operating gas turbine engines, including spatially resolved and point-based measurement techniques.

42 ENGINEERING↗

How much information on precipitation is contained in satellite infrared imagery?

Satellite infrared (IR) brightness temperature providing information on the characteristics of cloud tops is one of the primary input data used for estimating precipitation from satellites. Thus, the natural questions to ask are: Does IR imagery contain more information about precipitation in some regions more than others? What are the factors that lead to such differences? Should we expect the amount of information provided by IR imagery to change with respect to temporal or spatial aggregation? Comprehensive analysis of the accuracy of satellite-based precipitation estimates obtained from any given algorithm may provide qualitative answers to the above questions. However, such an approach only offers conclusions within the limited context of the algorithm used to obtain precipitation estimates; that is, patterns caused by the inherent information content of IR imagery are inextricable from those induced by assumptions embedded in the precipitation estimation algorithm. Here, we address the abovementioned questions from a different perspective using an information-theoretic measure, free of structural assumptions and general to a wide range of relationships, to characterize the average and seasonal dependence between IR imagery provided by satellite sensors in the spectral range (10.7–11.5 μm) and precipitation rates in the contiguous United States (CONUS) across distinct temporal and spatial scales. We analyze a total of more than 1.3 billion pairs of IR and precipitation observations over CONUS, and we observe interesting patterns. First, we show that there is a strong inverse relationship (ρ = - 0.73) between the information content of IR data and the number of no-rain observations; however, its robustness varies regionally and seasonally with less significant correlation during the warm season. Second, we demonstrate that the intuitive relationship of increasing dependence between IR and precipitation as a result of temporal or spatial aggregation exhibits a diminishing returns behavior. For instance, temporal aggregation from 1 to 3 h increases the dependence approximately 7 times as much as temporal aggregation from 12 to 24 h. Furthermore, we quantitatively examine and re-confirm several statements previously reported in the literature such as the strong association between IR and precipitation in convective storms and the low association in orographic rainfall. Finally, we conclude by illustrating the potential of the analysis in diagnosis of operational algorithms for estimating precipitation from IR brightness temperature. The findings of this study pinpoint spatial domains and time scales at which IR is not an adequate proxy for estimating precipitation. Thus, they can potentially guide the development of operational algorithms that utilize satellite Infrared imagery for estimating, downscaling and data fusion of precipitation. Finally, the analysis presented here opens up the possibility of developing new methodologies for diagnosis of satellite-based precipitation estimation algorithms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Laser-Induced Graphene. Flexible Electronics beyond the Visible Limit

Laser-induced graphene (LIG) is a multifunctional graphene foam that is commonly direct-written with an infrared laser into a carbon-based precursor material. Here, a visible 405 nm laser is used to directly convert polyimide into LIG. This enabled the formation of LIG with a spatial resolution of ~12 μm and a thickness of <5 μm. The spatial resolution enabled by the relatively smaller focused spot size of the 405 nm laser represents a >60% reduction in LIG feature sizes reported in prior publications. This process occurs in situ in an SEM chamber, thus allowing direct observation of LIG formation. The reduced size of the LIG features enables the direct-write formation of flexible electronics that are not visible to the unaided eye. A humidity sensor is demonstrated which could detect human breath with a response time of 250 ms. With the growing interest in LIG for flexible electronics and sensors, finer features can greatly expand its utility.

36 MATERIALS SCIENCE↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Widespread windthrow in Southeast Asian tropical forests verified by satellite observations

Windthrow, defined as abrupt tree mortality caused by intense winds, is well documented in the Neotropics but remains largely unverified in Asian tropical forests. Using Landsat 8 imagery for the period 2020-2022 and established spectral (shortwave-infrared, near-infrared, and red band composites) and morphological criteria (fan-shaped geometry and sharp boundaries), this study verified the presence of windthrow across Sumatra, Borneo, and New Guinea and produced the first georeferenced inventory of 60 events in the region. Event sizes were right-skewed, with many small gaps and few large (>200 ha) disturbances. Orientations were anisotropic, with concentrations of windthrow events pointing west to northwest-to-north and eastward, both aligning with known pathways of organized convection in the Maritime Continent of Southeast Asia. Detection was conservatively biased low by cloud cover, long revisit intervals, and the exclusion of land-use areas. This study provides a verified baseline that enables reproducible mapping with higher resolution sensors and field observations to quantify windthrow frequency, severity, and ecological significance.

Asia’s tropical forests↗

A near-infrared optical nanosensor for measuring aerobic respiration in microbial systems

We developed a ratiometric oxygen-sensitive nanosensor and demonstrated application in monitoring metabolic oxygen consumption in microbial samples over time. Based on a near-infrared (NIR) emitting oxygen-quenched luminophore, platinum(II) octaethylporphine ketone (PtOEPK), along with a stable dioctadecyl dicarbocyanine reference dye (DiD), this nanosensor system provides an advantageous approach for overcoming imaging issues in biological systems, such as autofluorescence and optical scattering in the visible wavelength region. The dyes are encapsulated within a polymer-based nanoparticle matrix to maintain them at a constant ratio in biological samples, precluding the need for complex synthetic approaches. With this constant ratio of the two dyes, the nanosensor response can be measured as a ratio of their two signals, accounting for nanosensor concentration artifacts in measurements. The nanosensors are reversible, which enabled us to temporally monitor systems in which dissolved oxygen concentrations both increase and decrease. These sensors were applied for the monitoring of oxygen in samples of Saccharomyces cerevisiae (brewing yeast) in a 96-well optical fluorescence plate reader format over 60 h. By mixing the nanosensors directly into the sample well with the yeast, we were able to dynamically track metabolic activity changes over time due to varying cell concentration and exposure to an antimicrobial agent. As a result, this system could be a potential platform for high-throughput screening of various species or variants of microbes with unknown metabolic rates in response to external stimuli (antimicrobials, metabolites, etc.).

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Luminescent Metal–Organic Framework for the Selective Detection of Aldehydes

The detection of toxic, hazardous chemical species is an important task because they pose serious risks to either the environment or human health. Luminescent metal–organic frameworks (LMOFs) as alternative sensors offer rapid and sensitive detection of chemical species. Interactions between chemical species and LMOFs result in changes in the photoluminescence (PL) profile of the LMOFs which can be readily detected using a simple fluorometer. Herein, we report the use of a robust, Zn-based LMOF, [Zn 5 (μ 3 -OH) 2 (adtb) 2 (H 2 O) 5 ·5 DMA] (Zn-adtb, LMOF-341), for the selective detection of benzaldehyde. Upon exposure to benzaldehyde, Zn-adtb experiences significant luminescent quenching, as characterized through PL experiments. Photoluminescent titration experiments reveal that LMOF-341 has a detection limit of 64 ppm and a Ksv value of 179 M –1 for benzaldehyde. Furthermore, we study the guest–host interactions that occur between LMOF-341 and benzaldehyde through in situ Fourier transform infrared and computational modeling employing density functional theory. The results show that benzaldehyde interacts more strongly with LMOF-341 compared to formaldehyde and propionaldehyde. Furthermore, our combined studies also reveal that the mechanism of luminescence quenching originates from an electron-transfer process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Custom NEON AOP reflectance mosaics and maps of shade masks, canopy water content

This mosaic of visible to shortwave infrared (VSWIR) data was derived from the assignable asset NEON AOP radiance data that was collected by LBNL’s Watershed Function SFA during the summer of 2018 (DOI: 10.15485/1617204). This atmospheric correction was completed to take into account site-specific terrain variability in the 334 km2 survey area centered around Crested Butte, CO. The atmospheric correction was completed using ACORN atmospheric correction software executed on 200 x 200 pixel kernels rather than line by line in order to capture local flight altitude conditions. Manual cloud delineation removed any small shaded areas that occurred within the data collection areas. Mosaics were developed based on preference for days that were in close timing proximity to the coincident ground campaign and with mosaicing criteria that minimized the angle between the sun and the sensor to retrieve the most consistent reflectance (min_phase_refl_tiled). Finally, we generated shade masks based on the geometry between the sun angle at time of flight, the ground surface, and the sensor. Here we provide the orthomosaiced estimated reflectance data (min_phase_refl_tiled.tif), canopy water content (wtrl), estimated atmospheric water vapor (wtrv), the observational data (obs) for this particular mosaic, the estimated visibility (vis), shade masks derived from the digital surface elevation model (shade) and the digital terrain model (shade_tch) added to the canopy height model (DOI: 10.15485/1617203), and a wavelength metadata file. Each image file is provided as a GeoTiff with internal tiling and LZW compression. These data can also be found on Google Earth Engine for extraction, download, and analysis of smaller extents (Google Earth Engine data is linked in external link table).

2018 NEON and 2025 CHESS Campaigns↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Guest@MOF Interaction via Stepwise Thermal Annealing: TCNQ@Cu 3 (BTC) 2

Confinement of guest molecules in porous materials such as metal organic frameworks (MOFs) promises to deliver emergent properties separate from those of the individual components. Understanding the confinement mechanism is therefore important for the development of new synthesis routes that adjust MOF properties for specific applications. In this work, we developed a new synthetic method to confine guest molecules into MOF pores through a stepwise thermal annealing process, wherein the confinement of 7,7,8,8-tetracyanoquinodimethane (TCNQ) guest molecules into Cu 3 (BTC) 2 (BTC = benzene-1,3,5-tricarboxylic acid) MOF host is used as an example of how novel materials can be created with new physical properties. The stepwise thermal annealing process includes 1) an activation process of pristine Cu 3 (BTC) 2 MOF to maximizes the TCNQ guest loading in the MOF host by effectively removing the residual solvents and 2) post-annealing of the TCNQ infiltrated MOF to enhances the interaction of the confined guest molecules with the MOF host. Obtained experimental results based on thermogravimetric analysis, N 2 gas adsorption, electron microscopy, X-ray diffraction and infrared absorption, combined with density functional theory calculations provide evidence that the use of a stepwise thermal annealing process yields enhancements in the guest loading, packing and interaction between the TCNQ guest and the MOF host. The new hybrid TCNQ@Cu 3 (BTC) 2 system is stable and shows no significant signs of structural degradation even after submersion in water. This is due to the presence of significantly stronger interactions of TCNQ with the frame-work metal ions compared to those of the water molecules competing for the same framework binding sites. It was also found that TCNQ@Cu 3 (BTC) 2 system maintains a significant CO 2 and CH 4 adsorption potential compared to the pristine MOF. The synthetic route developed in this work yields novel guest@MOF hybrid systems that will be useful for many MOF-based applications such as gas separations and chemical sensors performed under humid conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Evolution of Mixed-Addenda Keggin Polyoxometalate Anions with Atom-by-Atom Substitution

Polyoxometalates (POMs) are molecular metal oxides with distinctive electronic properties that make them promising materials for applications in energy, sensors, and memory devices. One of the most promising methods of tuning the stability, photochromic, redox, and electron-spin properties of POMs is through the substitution of the metal “addenda” atoms that, along with oxygen, constitute their cage-like structures. Because traditional synthesis methods typically produce a distribution of POMs, the isolation and characterization of multimetallic POMs with predetermined stoichiometry remains challenging. The presence of multiple energetically accessible isomers further complicates the experimental characterization and theoretical modeling of multimetallic POMs. Herein, we leverage the distinguishing mass-selection capabilities of ion soft landing to prepare stoichiometrically selected Keggin PMo x W 12-x O 40 3- (x = 0 – 6, 8, 10, and 12) POMs on self-assembled monolayer surfaces free of the solvent molecules and counterions that often confound characterization of complex species at interfaces. The structures of the supported POMs are characterized with atom-by-atom precision using in situ infrared (IR) reflection absorption spectroscopy complemented by detailed density functional theory calculations. Our joint experimental and theoretical results reveal an almost linear shift in the positions of the IR bands towards lower wavenumbers with an increase in the number of lighter molybdenum atoms compared to heavier W atoms in PMoxW 12-x O 40 3- . The theoretical calculations also indicate that numerous isomeric structures may be populated at the experimental conditions and, consequently, contribute to the overall IR spectra. In conclusion, our findings indicate that in addition to the number of substituted addenda atoms and the presence of multiple isomeric structures, interactions with the surface play an important role in determining the IR spectra and structure of supported bimetallic POMs.

Prabhakaran, Venkateshkumar [Pacific Northwest Nat↗

Interconnection of the Antenna Pigment 8-HDF and Flavin Facilitates Red-Light Reception in a Bifunctional Animal-like Cryptochrome

Cryptochromes are ubiquitous flavin-binding light sensors closely related to DNA-repairing photolyases. The animal-like cryptochrome CraCRY from the green alga Chlamydomonas reinhardtii challenges the paradigm of cryptochromes as pure blue-light receptors by acting as a (6-4) photolyase, using 8-hydroxy-5-deazaflavin (8-HDF) as a light-harvesting antenna with a 17.4 Å distance to flavin and showing spectral sensitivity up to 680 nm. The expanded action spectrum is attributed to the presence of the flavin neutral radical (FADH•) in the dark, despite a rapid FADH• decay observed in vitro in samples exclusively carrying flavin. Herein, the red-light response of CraCRY carrying flavin and 8-HDF was studied, revealing a 3-fold prolongation of the FADH• lifetime in the presence of 8-HDF. Millisecond time-resolved ultraviolet-visible spectroscopy showed the red-light-induced formation and decay of an absorbance band at 458 nm concomitant with flavin reduction. Time-resolved Fourier transform infrared (FTIR) spectroscopy and density functional theory attributed these changes to the deprotonation of 8-HDF, challenging the paradigm of 8-HDF being permanently deprotonated in photolyases. FTIR spectra showed changes in the hydrogen bonding network of asparagine 395, a residue suggested to indirectly control flavin protonation, indicating the involvement of N395 in the stabilization of FADH•. Fluorescence spectroscopy revealed a decrease in the energy transfer efficiency of 8-HDF upon flavin reduction, possibly linked to 8-HDF deprotonation. Finally, the discovery of the interdependence of flavin and 8-HDF beyond energy transfer processes highlights the essential role of the antenna, introducing a new concept enabling CraCRY and possibly other bifunctional cryptochromes to fulfill their dual function.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Brighter-fatter Effect in Near-infrared Detectors—III. Fourier-domain Treatment of Flat Field Correlations and Application to WFIRST

Weak gravitational lensing has emerged as a leading probe of the growth of cosmic structure. However, the shear signal is very small and accurate measurement depends critically on our ability to understand how non-ideal instrumental effects affect astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will fly a focal plane containing 18 Teledyne H4RG-10 near-infrared detector arrays, which present different instrument calibration challenges from previous weak lensing observations. Previous work [Paper I: Hirata & Choi, PASP, 132, 014501 (2020); and Paper II: Choi & Hirata, PASP, 132, 014502 (2020)] has shown that correlation functions of flat field images, including cross-correlations between different time slices that are enabled by the non-destructive read capability of the infrared detectors, are effective tools for disentangling linear and nonlinear inter-pixel capacitance (IPC) and the brighter-fatter effect (BFE). Here we present a Fourier-domain treatment of the flat field correlations, which allows us to expand the previous formalism to all orders in IPC, BFE, and classical nonlinearity. We show that biases in simulated flat field analyses in Paper I are greatly reduced through the use of this formalism. We then apply this updated formalism to flat field data from three WFIRST flight candidate detectors, and explore the robustness to variations in the analysis. We find that the BFE is present in all three detectors, and that its contribution to the flat field correlations dominates over the nonlinear IPC, in accordance with the results from Paper II on a development detector. The magnitude of the BFE is such that the effective area of a pixel is increased by (3.54 ± 0.03) × 10 -7 for every electron deposited in a neighboring pixel (sensor chip assembly [SCA] 20829, statistical error, not IPC-deconvolved). We compare IPC maps from flat field autocorrelation measurements to those obtained from the single pixel reset method and find a median difference of 0.113% for SCA 20829. After further diagnosis of this difference, we ascribe it largely to an additional source of cross-talk, the vertical trailing pixel effect, and recommend further work to develop a model for this effect. These results represent a significant step toward calibration of the non-ideal effects in WFIRST detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

A Nowcasting Approach for Low-Earth-Orbiting Hyperspectral Infrared Soundings within the Convective Environment

Low-Earth-orbiting (LEO) hyperspectral infrared (IR) sounders have significant yet untapped potential for characterizing thermodynamic environments of convective initiation and ongoing convection. While LEO soundings are of value to weather forecasters, the temporal resolution needed to resolve the rapidly evolving thermodynamics of the convective environment is limited. Here, we have developed a novel nowcasting methodology to extend snapshots of LEO soundings forward in time up to 6 h to create a product available within National Weather Service systems for user assessment. Our methodology is based on parcel forward-trajectory calculations from the satellite-observing time to generate future soundings of temperature (T) and specific humidity (q) at regularly gridded intervals in space and time. The soundings are based on NOAA-Unique Combined Atmospheric Processing System (NUCAPS) retrievals from the Suomi National Polar-Orbiting Partnership (Suomi NPP) and NOAA-20 satellite platforms. The tendencies of derived convective available potential energy (CAPE) and convective inhibition (CIN) are evaluated against gridded, hourly accumulated rainfall obtained from the Multi-Radar Multi-Sensor (MRMS) observations for 24 hand-selected cases over the contiguous United States. Areas with forecast increases in CAPE (reduced CIN) are shown to be associated with areas of precipitation. The increases in CAPE and decreases in CIN are largest for areas that have the heaviest precipitation and are statistically significant compared to areas without precipitation. These results imply that adiabatic parcel advection of LEO satellite sounding snapshots forward in time are capable of identifying convective initiation over an expanded temporal scale compared to soundings used only during the LEO satellite overpass time.

54 ENVIRONMENTAL SCIENCES↗