PARALLEL FLEXURE-BASED RADSI INSTRUMENT FOR CURVED X-RAY MIRROR METROLOGY
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Surface precipitation measurements are essential for Earth system model (ESM) evaluation and understanding cloud processes. An ever-growing need for robust, temporally evolving, and easy-to-use statistical datasets provides motivation for a baseline ground-based precipitation properties data product. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility operates an extensive suite of precipitation instruments with various sensitivities and operating mechanisms, which render the decision of which instrument to use based on one or more fixed thresholds challenging and prone to errors and bias. Using a long-term instrument inter-comparison from a unique per-precipitation event perspective, rather than instantaneous sample comparison, we demonstrate that ARM rainfall-measuring instruments are generally consistent with each other at the statistical level. Inter-instrument deviations at the single event level can be large, especially for specific rainfall event properties such as maximum precipitation rates. A machine-learning (ML) analysis using a random forest regressor indicates that in some cases, depending on instrument, local site climatology, and/or specific deployment configuration, certain atmospheric state variables influence the measured quantities in an unpredictable manner. Thus, a-priori weighting of different instruments does not necessarily lead to more accurate and less biased synthesis of instrument data. These results motivate the design of the ARM precipitation best-estimate (PrecipBE) value-added product, which incorporates all valid precipitation data while considering data quality and other instrument limitations. PrecipBE consists of time series and tabular statistics datasets in an easy-to-use and insightful per-precipitation event format. It provides a large set of precipitation event properties supplemented with ancillary data from ARM datasets that correspond to the detected precipitation events. We describe the PrecipBE algorithm and demonstrate its use via the examination of a single-day output as well as a long-term trend analysis of precipitation events at the ARM Southern Great Plains (SGP) site, covering more than 30 years of data. The trend analysis tentatively suggests a long-term temporal tendency for mainly shorter and less intense precipitation events at the SGP site, but a long-term increase in annual rainfall by more than 36 mm (5 %) per decade. This rainfall trend is catalyzed primarily by more extreme event properties of relatively rare, intense precipitation events, with event total and 1 min maximum precipitation rate at a 1 year timeframe increasing up to 5 mm and 9 mm h −1 (several percent) per decade, respectively. While the currently available PrecipBE datasets (at https://adc.arm.gov/discovery/, last access: 8 December 2025) cover rainfall from multiple ARM deployments up to March 2025, PrecipBE is planned to be expanded to include solid-phase precipitation and will soon become an operational product with a several-day lag from real-time. We invite the ARM user community to leverage this new product and welcome user feedback to further enhance the dataset.
Arrays of instruments for monitoring winter precipitation (snowfall) and snow cover on the ground installed in 2017 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska (NSA) C1 and at Oliktok Point sites became operational in 2018. In 2022, the instruments from Oliktok Point were moved to NSA E12, about 5.4 km south of NSA C1, where two arrays now operate. The instrument arrays monitor wind speed and direction, snow depth at multiple locations, the horizontal flux of blowing snow, and the number and fall speed of hydrometeors. The arrays are monitored using digital cameras. Collectively, the instruments produce a wealth of data on falling and accumulated snow, but, as with any instrument array, some data are more reliable and accurate than others. In this document, we present our findings on the efficacy, accuracy, and reliability of each type of instrument. Overall, a key finding is that no single instrument provides sufficient information to determine the source of falling snow particles nor the cause of changes in snow depth. However, if used in concert, the instruments produce a reliable understanding of the processes affecting the snow cover depth distribution and the true winter precipitation.
Los Alamos National Laboratory (LANL) operates seven mesa-top instrumented meteorology towers: Technical Area (TA) 6, TA-49, TA-53, TA-54, TA-63, TA-54B, and TA-16B. An additional instrumented tower is located in Mortandad Canyon (TA-5 MDCN), and there is a rain gauge at North Community (NCOM), located within the town of Los Alamos. The 10 meter (m) towers at TA-63, TA-54B, and TA-16B have been in testing since they were installed in 2021, and will be included in a future data completeness report. A description of the meteorology monitoring network, prior to the installation of the TA-63, TA-54B, and TA-16B is found in Dewart and Boggs (2014). Four of the mesa-top towers (e.g., TA-6, TA-49, TA-53, and TA-54) are instrumented at the 1.2 m, 11.5 m, 23 m, and 46 m levels. In addition, the TA-6 tower is instrumented at the 92 m level. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected and averaged every 15 minutes. Range checking is performed on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by qualified meteorologists to identify bad data not identified by the range checking technique. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement, as required. All instruments are calibrated at a frequency that meets the criteria identified in ANSI/ANS-3.11-2015. Data completeness is determined by the number of total 15-minute records available versus the number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, including bad data, can be recalled from program archival storage.
During the development activities of SuperCam Calibration Target, target intended for one of the two first Raman instruments to be deployed on another planetary body, our group developed a laboratory instrument that could simulate to some extent the Raman capabilities of one of such instruments and could provide data with similar quality. The use of this kind of laboratory instruments has demonstrated its utility in the evaluation of potential calibration targets or anticipating the science outcome that an instrument could provide. The present work describes our laboratory setup to support SuperCam, evaluating similarities between both instruments, despite of differences in the hardware. Evaluation of data gathered by SuperCam on Mars and the availability of one replica of SuperCam’s Calibration Target allowed the comparison on the same set of targets, demonstrating how similar Signal-to-Noise Ratio (SNR) could be achieved from both instruments. The higher energy per pulse on SimulCam is compensated by a greater analytical footprint and the use of smaller collection optics. The results show how spectra obtained at representative distances of SuperCam are comparable. Operational principles are also comparable in terms of time resolution, and close in terms of spectral resolution. This similarity has allowed different science support works using SimulCam data, as well as the support to Mars detections using our setup. We provide examples of this support that will be shared with the community in different papers, as well as examples of possible operations activities that could benefit from experiments performed with SimulCam. We show how this setup can complement the two laboratory replicas in Los Alamos and Toulouse in providing support data to different experiments.
From July 21 through August 22, 2025 the Absorption Measurement Inter-Comparison Experiment phase 2 (AMICE2) was conducted at Brookhaven National Laboratory. The experiment included concurrent operation of several filter-based instruments and in situ instruments sampling from a common sample line. The common sample line provided all instruments with either lab-generated aerosols composed of external mixtures of nigrosin, cabojet, and ammonium sulfate, or with ambient aerosol drawn through an external stack. This data set contains measurements from the CAPS PMssa instrument taken as a reference instrument at 532 nm and against which the effectiveness of the filter corrections may be assessed. It also contains attenuation coefficients from all filter-based instruments and filter transmittances in order to permit correction for filter loading, and the SSA and COA to permit corrections for aerosol darkness. Finally, two sets of multiplicative corrections are provided for the AE-33, TAP, and MA-350 instruments: the first one, Corr1, corrects for filter amplification factor and loading, the second one, Corr2, corrects for the aerosol darkness in terms of the natural log of COA.
A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.
The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud-formation processes and their influence on radiative transfer. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, known as Mentors. Mentors must have an excellent understanding of instrumentation theory and operation for their instrument areas and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Facility seeks the best overall qualified candidate, or team when appropriate, that can fulfill Mentor requirements in a timely manner. The roles and responsibilities of the ARM Instrument Operations Manager are provided in Appendix A. The key role and responsibilities and detailed responsibilities of ARM Lead Mentors are provided in Appendix B and Appendix C, respectively.
Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.
Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.
Edge computing enables “next-to-instrument” control and intelligent data volume reduction and the potential for autonomous, adaptive measurement strategies such as for automated control of scan strategies for Doppler lidar (DL). Instruments with narrow bandwidth connections (e.g., ship and remote sites) can do scene determination and save phenomenon-appropriate data. For example, Doppler spectrum can be saved when clouds are detected by the instrument or automatic moment detection can take place in camera images and only preserve spectrum when non-monomodal spectra are detected. Automated control at the edge involves changing the sampling (temporal or scanning strategy) of an instrument to suit the phenomena both present and being studied (Jackson et al. 2020). Both data processing and instrument control introduces the possibility of a software-defined instrument.
Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.
The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.
Upgrades to advanced scientific user facilities such as next-generation x-ray light sources, nanoscience centers, and neutron facilities are revolutionizing our understanding of materials across the spectrum of the physical sciences, from life sciences to microelectronics. However, these facility and instrument upgrades come with a significant increase in complexity. Driven by more exacting scientific needs, instruments and experiments become more intricate each year. This increased operational complexity makes it ever more challenging for domain scientists to design experiments that effectively leverage the capabilities of and operate on these advanced instruments. Large language models (LLMs) can perform complex information retrieval, assist in knowledge-intensive tasks across applications, and provide guidance on tool usage. Using x-ray light sources, leadership computing, and nanoscience centers as representative examples, we describe preliminary experiments with a Context-Aware Language Model for Science (CALMS) to assist scientists with instrument operations and complex experimentation. With the ability to retrieve relevant information from facility documentation, CALMS can answer simple questions on scientific capabilities and other operational procedures. With the ability to interface with software tools and experimental hardware, CALMS can conversationally operate scientific instruments. By making information more accessible and acting on user needs, LLMs could expand and diversify scientific facilities’ users and accelerate scientific output.
2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.
Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.
The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.
Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.