Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Mesospheric measurements of irregularity patches using a 3-antenna interferometer, part 3.6B

Three events of mesospheric radar returns have been isolated to illustrate the potential of a three-antenna interferometer in the study of the neutral atmosphere. Contour plots of echo intensity and the presence of irregularities in isolated and well-defined regions are shown. These measurements were carried out using the SOUSY radar in the Harz mountains in Germany, on September 9, 1980. The system frequency is 53.5 MHz. Local time is 2 hours in advance of Universal time. The irregularities wavelength is 2.81 m and the three arms of the interferometer were sampled with 167 ms of time difference. To provide precise estimates of vertical velocities, the measured (radial) Doppler shift has to be corrected to subtract the contribution due to the horizontal motions. For near-vertical observations (zenith angle less than about 10 deg) it is readily shown that the rate of change of the measured phases are related to the velocities V sub eq, V sub ns (in the East-West and North-South directions).

Ierkic, H. M.↗

Rainbow schlieren vs Mach-Zehnder interferometer - A comparison

The rainbow schlieren apparatus is simpler, cheaper, and more easily built to large scale than the interferometer. The accuracies of the two instruments are similar but only if refraction is properly accounted for in interferometry. The measurement thresholds of both instruments are similar. The rainbow schlieren device provides more detailed information because the detection threshold of the rainbow schlieren is an order of magnitude better than that of the interferometer.

Howes, W. L.↗

Interferometer for Observing Compressible Flow

Moving pictures show changing flow-field contours. Optical interferometer enables instantaneous visualization of compressible fluid flows. Relatively immune to vibration, unit suited to observation of flows over models in large wind tunnels. In improved point-diffraction interferometer, reference beam generated by pinhole (point) diffraction at place in object beam outside experimental volume. Object under test positioned so interior or supporting stand lies in shadows of turning mirrors.

Bacnalo, W.↗

Lens collimation and testing using a Twyman-Green interferometer with a self-pumped phase-conjugating mirror

Ordinarily Twyman-Green interferometers are employed testing optical elements. In a modification of the basic configuration, the ordinary mirror in the test arm is replaced with a self-pumped phase-conjugating mirror using a barium titanate crystal. It is shown that, with a redefinition of components, the new configuration permits retention and improvement of the optical element testing function while simultaneously serving as a sensitive test for collimation. The optical path difference resulting from the double pass in the original Twyman-Green interferometer approximately equals that of the single pass and phase conjugation in the modification.

Howes, W. L.↗

Planetary searches using optical astrometric interferometers

The detectability of planets is discussed, and observations made with an astrometric interferometer (AI) at Mount Wilson are presented. Planets are detectable as a result of their periodic perturbation of the position of a central observable star. This detection requires relative astrometric accuracies of about 3 x 10 to the -4th for Jovian planets and about 3 x 10 to the -7th arcsec for terrestrial planets. The principles governing astrometric interferometry are explained, and it is conjectured that a two-color optical AI on earth should be capable of about 0.0001 arcsec rms accuracy for stars brighter than magnitude 7-10; small one-color space systems should achieve at least 0.00001 arcsec. Owing to atmospheric turbulence, two-color systems permit correction every few milliseconds for the random wavefront tilt. A 3.4-meter baseline interferometer on Mount Wilson has demonstrated arcsec rms fluctuations of about 0.02 for 1-sec samples. Space-based optical astrometric interferometry is also discussed.

Staelin, D. H.↗

Comparison of medium frequency pulsed radar interferometer and correlation analysis winds, part 1

In principle, the interferometer analysis determines the radial velocity and direction of single scatterers provided that each has a sufficiently different Doppler frequency to permit separation by spectral analysis. In fact, scatterers will not have constant radial velocity, and their Doppler frequencies as well as their directions will be modulated by their horizontal motion. Thus, there is a tradeoff between the poorer resolution but less smeared scatterers on shorter records and the higher resolution (longer) records. Three or more non-collinear scatterers are sufficient to determine the wind. It appears that the velocity found from the combined interferometer peaks agrees well with the apparent velocity from correlation methods, but the true velocity is a factor of 2 smaller. This difference might be resolved by searching for scatters showing regular movement between adjacent records.

Meek, C. E.↗

Comparison of medium frequency pulsed radar interferometer and correlation analysis winds, part 2

In order to test whether the chosen Doppler peaks represent localized scatters in motion, as opposed to some sort of integrated composite, an attempt was made to determine the change in position of single scatterers over a series of sequential records. A four-antenna system was employed which had 1 degree of freedom in phase. Due to limitations N-S linear transmission and E-W linear reception were used. The Doppler frequency peak selection criteria were that at least two of the four power spectra should have a local peak, and that normalized phase discrepancy, should be less than 0.3. The lack of success in tracking individual scatters seems to suggest a short lifetime. If this is the case, then the present experiment is not able to resolve the difference found between the correlation analysis true velocity and the interferometer value. On the other hand, it appears that the interferometer may be of some use in tracking waves.

Meek, C. E.↗

Fiber-optic interferometer using frequency-modulated laser diodes

This paper describes an electrically passive fiber-optic interferometer which uses dual frequency-modulated laser diodes. Experimental results show that this type of interferometer can attain a displacement range of 100 micron with subnanometer resolution. This technique can serve as the basis for a number of high-precision fiber-optic sensors.

Beheim, G.↗

Observation of molecular rotational bands with a single Fabry-Perot interferometer

A method is described for using a single Fabry-Perot interferometer to study the emissions from an entire molecular rotation band, not just a single line to determine atmospheric temperature. It is shown that if the effective line spacing of the band to free spectral range is nearly a rational number, the resulting signal is highly temperature sensitive, particularly at low temperatures. It is shown that the finesse of the instrument is not extremely important but that the instrument function must be known very precisely. The method is illustrated with the O2 atmospheric band and an interferometer flown on the Dynamics Explorer 2 satellite.

Skinner, Wilbert R.↗

Atmospheric phase measurements with the Mark III stellar interferometer

The effect of atmospheric turbulence on the measurements of stellar positions performed by the Mt. Wilson phase-coherent stellar Mark III interferometer was investigated, both for the case of a simple Kolmogorov spatial spectrum and for the case of a model incorporating a finite outer scale. Measurements of phase difference at a 12-m base line obtained with the Mark III interferometer agreed well with the predictions of a Kolmogorov spatial spectrum over the frequency range 0.001-100 Hz. From these measurements, the outer scale of turbulence for propagation through the entire atmosphere was estimated to be greater than 2 km.

Colavita, M. Mark↗

Low-noise interferometer for microwave radiometry

An interferometer for precision measurements in microwave radiometry is proposed which uses two low-noise heterodyne receivers based on SIS tunnel junction mixers in the 40-50-GHz band. The antenna interference pattern has lobes which lead to positive output signals and lobes which give negative output, and the radiometer measures the difference in the power from these lobes without beam switching or instrument motion. The present system cancels instrumental signals, has a very low 1/f noise in the output, and has a zero outpus signal when viewing a uniform source. It is noted that application of the interferometer may be limited to radiometry with relatively large beams.

Timbie, P. T.↗

Radiometric calibration of IR Fourier transform spectrometers - Solution to a problem with the High-Resolution Interferometer Sounder

A calibrated Fourier transform spectrometer, known as the High-Resolution Interferometer Sounder (HIS), has been flown on the NASA U-2 research aircraft to measure the infrared emission spectrum of the earth. The primary use - atmospheric temperature and humidity sounding - requires high radiometric precision and accuracy (of the order of 0.1 and 1 C, respectively). To meet these requirements, the HIS instruments, the HIS instrument performs inflight radiometric calibration, using observations of hot and cold blackbody reference sources as the basis for two-point calibrations at each wavenumber. Initially, laboratory tests revealed a calibration problem with brightness temperature errors as large as 15 C between 600 and 900/cm. The symptom of the problem, which occurred in one of the three spectral bands of HIS, was a source-dependent phase response. Minor changes to the calibration equations completely eliminated the anomalous errors. The new analysis properly accounts for the situation in which the phase response for radiance from the instrument itself differs from that for radiance from an external source. The mechanism responsible for the dual phase response of the HIS instrument is identified as emission from the interferometer beam splitter.

Revercomb, Henry E.↗

Planned improvements to the Owens Valley frequency-agile interferometer

Three small antennas will be added to the OVRO interferometer to form a five-element solar-dedicated array. This would provide up to 7 or 10 baselines (compared to the present 1 or 3). This would be sufficient to apply microwave diagnostics to most active region and burst sources. By using frequency-synthesis it would also provide an imaging capability comparable to that of an approximately 100 baseline interferometer. Expansion of the array is discussed.

Hurford, Gordon J.↗

Using connected-element interferometer phase-delay data for Magellan navigation in Venus orbit

The pointing accuracy needed to support Magellan's Synthetic Aperture Radar mapping of Venus places stringent requirements on navigation accuracy. This need is met with a combination of two-way Doppler and narrowband delta Very Long Baseline Interferometer (delta VLBI) data, which are capable of determining the spacecraft's orbit to the required level, typically about one-kilometer position uncertainty. Differenced Doppler (two-way Doppler minus three-way Doppler) is also capable of meeting mission navigation requirements, and serves as a backup to narrowband delta VLBI. The Magellan Project specifies that the turn-around time for processing narrowband delta VLBI data must be 12 hours or less, a very difficult requirement to meet operationally. The use of phase-delay data, taken from a Connected-Element Interferometer (CEI) with a 21-km baseline, for Magellan orbit determination was investigated to determine if navigation performance comparable with narrowband delta VLBI and differenced Doppler could be achieved. CEI possesses an operational advantage over delta VLBI data in that the observables are constructed in near-real time, thus greatly reducing the turn-around time needed to process the data, relative to the off-line system used to generate delta VLBI observables. Unfortunately, the results indicate that CEI data are much less powerful than narrowband delta VLBI and differenced Doppler for orbiter navigation, although there was some marginal improvement over the navigation performance obtained when only two-way Doppler data were used.

Thurman, S. W.↗

Information content of a single pass of phase-delay data from a short baseline connected element interferometer

An analytic development of the information array obtained with a single tracking pass of phase-delay measurements made from a short baseline interferometer is presented. Phase-delay observations can be made with great precision from two antennas using a single, common distributed frequency standard, hence the name connected element. With the information array, closed-form expressions are developed for the error covariance in declination and right ascension. These equations serve as useful tools for analyzing the relative merits of candidate station locations for connected element interferometry (CEI). The navigation performance of a short baseline interferometer located at the Deep Space Network's (DSN's) Goldstone intracomplex is compared with that which is presently achievable using Very Long Baseline Interferometry (VLBI) over intercontinental baselines. The performance of an intracomplex pair of short baselines formed by three stations is also investigated, along with the use of a single baseline in conjunction with conventional two-way Doppler data. The phase-delay measurement accuracy and data rate used in the analysis are based on the expected performance of an experimental connected element system presently under construction at Goldstone. The results indicate that the VLBI system that will be used during the Galileo mission can determine the declination and right ascension of a distant spacecraft to an accuracy of 20 to 25 nrad, while the CEI triad system and the combination of CEI-Doppler system are both capable of 30 to 70 nrad performance.

Thurman, S. W.↗

Cryogenic mechanisms for scanning and interchange of the Fabry-Perot interferometers in the ISO long wavelength spectrometer

The Infrared Space Observatory (ISO) is an ESA cornerstone mission for infrared astronomy. Schedules for launch in 1993, its four scientific instruments will provide unprecedented sensitivity and spectral resolution at wavelengths which are inaccessible using ground-based techniques. One of these, the Long Wavelength Spectrometer (LWS), will operate in the 45 to 180 micron region (Emery et. al., 1985) and features two Fabry-Perot interferometers mounted on an interchange mechanism. The entire payload module of the spacecraft, comprising the 60 cm telescope and the four focal plane instruments, is maintained at 2 to 4 K by an onboard supply of liquid helium. The mechanical design and testing of the cryogenic interferometer and interchange mechanisms are described.

Davis, G. R.↗

Determination of refractive index of a simple negative, positive, or zero power lens using wedged plated interferometer

A nondestructive technique for measuring the refractive index of a negative lens using a wedged plate interferometer is described. The method can be also used for measuring the refractive index of convex or zero power lenses. Schematic diagrams are presented for the use of a wedged plate interferometer for measuring the refractive index of a concave lens and of a convex lens.

Shukla, R. P.↗

Calibration and operation of a large space-based optical interferometer

The on-orbit calibration of the optics, structure, and control systems of the CSI Focus Mission Interferometer (FMI) is described. The calibration involves the estimation and propagation of both positional and rotational parameters and the propagation of both positional and rotational parameters at the nanometer/nanoradian level. It is shown that, given a nanometer class metrology system to monitor positional changes of critical optical elements, this calibration procedure should enable the FMI to perform 50 picoradian astrometry. The same Kalman filter that implements the initializing calibration of the interferometer baselines and internal pathlengths will also participate in the astrometric measurements of stellar positions.

Laskin, R. A.↗