Nonlinear dynamics of combustor azimuthal modes: Experiments and modeling

This paper provides an experimental and theoretical investigation of azimuthal instabilities in a lean, premixed combustor. It presents data from a high Reynolds number, industrial-scale facility with multiple fuel stages that enable variation of radial and azimuthal symmetries. The combustor exhibits a variety of behaviors – including standing, spinning, mixed waves, and intermittent behaviors, as well as periodic limit cycles and quasi-periodic oscillations – depending upon varying power and azimuthal symmetry. A second key objective of this paper is to present a weakly nonlinear framework that is used to understand and interpret these results, showing the influence of eigenmode degeneracy, background noise, and azimuthal non-uniformities in mean quantities such as temperature and flame-acoustic coupling. In particular, this analysis shows the importance of the linear instability growth/damping rate and azimuthal non-uniformities in controlling the relative prominence of standing, spinning, or mixed waves at the limit cycle, as well as the preference in the spinning direction. It also shows the conditions under which single frequency or quasi-periodic oscillations are dominant, and how these are more fundamentally influenced by azimuthal non-uniformities and background noise.

42 ENGINEERING↗

In situ multi-tier auto-ignition detection applied to dual-fuel combustion simulations

Here we use an anomaly detection methodology that is centered on analyzing fourth-order joint moments (co-kurtosis), particularly focusing on its application in auto-ignition of combustion problems with large numbers of species. Unsupervised anomaly detection is challenging to generalize across problem types and domains. A recent technique, centered on analyzing information in the fourth-order joint moment co-kurtosis, has shown promise, especially for high-dimensional scientific data. In this work we present developments to the co-kurtosis based anomaly detection method needed to make it effective and scalable for large-scale distributed scientific data, such as those generated by massively parallel simulations. An in situ co-kurtosis algorithm is employed as the anomaly detection method for identifying ignition kernels in simulations of turbulent combustion. Here, we extend an existing methodology which identifies regions of the domain where anomalies are present, and add another tier of anomaly detection where the individual samples contributing to the anomaly are identified. We apply this algorithm on-the-fly to a variety of turbulent reacting flow problems and compare it to the widely used (but significantly more expensive) chemical explosive mode analysis (CEMA). We demonstrate the ability of the method to detect and identify the onset of low and high temperature ignition which can be used for computational steering, as chemical and combustion anomalies occur intermittently at spatio-temporal locations unknown a priori. Finally, we apply our lightweight in situ algorithm to an exascale high-fidelity simulation with a total of 2.4 Trillion degrees of freedom, performed using an adaptive mesh refinement solver. Furthermore, through a scalability analysis, we show that the relative computational cost of this in-situ anomaly detection algorithm compared to an iteration of the reacting flow solver is negligible.

97 MATHEMATICS AND COMPUTING↗

Development of novel dynamic machine learning-based optimization of a coal-fired power plant

The increasing fraction of intermittent renewable energy in the electrical grid is resulting in coal-fired boilers now routinely ramp up and down. The current state-of-the-art operation for such boilers is to apply steady-state, neural network-based optimization to make control decisions in real-time, and this report demonstrates the feasibility of extending this to dynamic, neural network-based optimization using a long short-term memory neural network. A simplified numerical simulation of a t-fired coal boiler and supporting equipment is used to represent a real plant subjected to both steady-state, neural network-based optimization and dynamic, neural network-based optimization. Using the same intervals and a particle swarm optimization algorithm, the dynamic optimization outperforms the steady-state optimization and realizes up to 4.58% improvement in thermal efficiency. Dynamic optimization with a long short-term memory neural network is shown to both be feasible and beneficial for operation of a coal-fired boiler under changing load.

42 ENGINEERING↗

Comprehensive assessment of deep reinforcement learning approaches for economic dispatch in nuclear-driven microgrids

As the electrical grid integrates more variable renewable energy sources such as wind and solar, the demand for distributed and flexible systems to address this increased variability becomes critical. Nuclear-driven microgrids provide a promising solution by offering stable generation to complement intermittent renewables, ensuring grid reliability and operating efficiency. This paper proposes a recurrent deep reinforcement learning framework for optimal economic dispatch in a nuclear-powered microgrid integrating renewable energy sources, small modular reactors, battery storage systems, and balance-of-plant dynamics. A three-agent control architecture is developed, where demand and renewable energy agents act as forecasters, and a reinforcement learning-based dispatch agent performs real-time energy allocation. A nonlinear programming formulation is first used to generate an optimal baseline for benchmarking. The proposed dispatch controller, based on Proximal Policy Optimization enhanced with Long Short-Term Memory networks, exploits temporal correlations in system dynamics by taking advantage of the time series used as inputs to improve policy robustness under uncertainty. Comparative analysis against established deep reinforcement learning methods, including Proximal Policy Optimization with a feedforward architecture, Soft Actor-Critic, and Twin Delayed Deep Deterministic Policy Gradient, demonstrates superior performance. Numerical results indicate that the proposed controller achieves a 0.39% cost reduction relative to the nonlinear programming benchmark and outperforms other learning-based methods by generating additional revenue of up to 0.35%. All reinforcement learning controllers compute dispatch actions in less than 0.3 s, resulting in a computational speedup of more than three orders of magnitude over the nonlinear programming baseline. The findings of this paper highlight their applicability for real-time operation and control in nuclear-integrated microgrids under volatile operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High plasticity in refractory composite fabrication by ultrasonic additive manufacturing

Refractory metal composites are desirable for use in extreme environments that require materials with high specific strengths and resilience to external environments such as that found in nuclear and aerospace. However, due to the high melting temperature of refractories, liquid state joining processes such as welding remains difficult. Ultrasonic additive manufacturing (UAM) provides a potential route for processing refractory composites because it is a solid-state (i.e., no-melting) process and allows for intermittent machining operations to be performed between welds. Further, to demonstrate refractory composite fabrication, this study utilized UAM to machine a cavity to locate and sequester a Mo foil in a Zircaloy-4 (Zry-4) baseplate and additively build over the top with Zry-4 foils, thereby embedding the Mo in Zry-4 matrix. Significant deformation of the Zry-4 microstructure was observed: this deformation caused adiabatic heating and subsequent dynamic recrystallization through the transformation from α→β and then back to α as the material cooled. Flexural testing of the Zr–Mo composite revealed no delamination or failure, but the strength was not as expected, falling lower than a cold-worked Zry-4 sample. Finite element analysis supported that some bonding must have existed between the Zry-4 and Mo. There was indeed an interdiffusion zone at the Zry-4 foil–Mo foil interface, observing a metastable body-centered cubic β-Zr lathe. It was determined that sufficient strain energy was present to encourage the nucleation of the β-Zr grain along α-Zr grains. Future work is warranted to investigate UAM for refractory composite fabrication.

36 MATERIALS SCIENCE↗

GPU-enabled extreme-scale turbulence simulations: Fourier pseudo-spectral algorithms at the exascale using OpenMP offloading

Fourier pseudo-spectral methods for nonlinear partial differential equations are of wide interest in many areas of advanced computational science, including direct numerical simulation of three-dimensional (3-D) turbulence governed by the Navier-Stokes equations in fluid dynamics. This paper presents a new capability for simulating turbulence at a new record resolution up to 35 trillion grid points, on the world's first exascale computer, Frontier, comprising AMD MI250x GPUs with HPE's Slingshot interconnect and operated by the US Department of Energy's Oak Ridge Leadership Computing Facility (OLCF). Key programming strategies designed to take maximum advantage of the machine architecture involve performing almost all computations on the GPU which has the same memory capacity as the CPU, performing all-to-all communication among sets of parallel processes directly on the GPU, and targeting GPUs efficiently using OpenMP offloading for intensive number-crunching including 1-D Fast Fourier Transforms (FFT) performed using AMD ROCm library calls. With 99% of computing power on Frontier being on the GPU, leaving the CPU idle leads to a net performance gain via avoiding the overhead of data movement between host and device except when needed for some I/O purposes. Memory footprint including the size of communication buffers for MPI_ALLTOALL is managed carefully to maximize the largest problem size possible for a given node count. Detailed performance data including separate contributions from different categories of operations to the elapsed wall time per step are reported for five grid resolutions, from 2048 3 on a single node to 32768 3 on 4096 or 8192 nodes out of 9408 on the system. Both 1D and 2D domain decompositions which divide a 3D periodic domain into slabs and pencils respectively are implemented. The present code suite (labeled by the acronym GESTS, GPUs for Extreme Scale Turbulence Simulations) achieves a figure of merit (in grid points per second) exceeding goals set in the Center for Accelerated Application Readiness (CAAR) program for Frontier. The performance attained is highly favorable in both weak scaling and strong scaling, with notable departures only for 2048 3 where communication is entirely intra-node, and for 32768 3 , where a challenge due to small message sizes does arise. Communication performance is addressed further using a lightweight test code that performs all-to-all communication in a manner matching the full turbulence simulation code. Performance at large problem sizes is affected by both small message size due to high node counts as well as dragonfly network topology features on the machine, but is consistent with official expectations of sustained performance on Frontier. Overall, although not perfect, the scalability achieved at the extreme problem size of 32768 3 (and up to 8192 nodes — which corresponds to hardware rated at just under 1 exaflop/sec of theoretical peak computational performance) is arguably better than the scalability observed using prior state-of-the-art algorithms on Frontier's predecessor machine (Summit) at OLCF. New science results for the study of intermittency in turbulence enabled by this code and its extensions are to be reported separately in the near future.

3D fast Fourier transform↗

Striving to translate shale physics across ten orders of magnitude: What have we learned?

Shales will play an important role in the successful transition of energy from fossil-based resources to renewables in the coming decades. Aside from being a significant source of low-carbon intensity fuels, like natural gas, they also serve as geologic seals of subsurface formations that may be used to isolate nuclear waste, sequester CO 2 , or store intermittent energy (e.g., solar hydrogen). Despite their importance, shales pose significant engineering and environmental challenges due to their nanoporous structure and extreme heterogeneity that spans at least ~10 orders of magnitude in spatial scale. Two challenges inhibit a system-level understanding: (1) the physics of fluid flow and phase behavior in shales are poorly understood due to the dominant molecular interactions between minerals and fluids under confinement, and (2) the apparent lack of scale separation that prevents a reliable (closed) description of the physics at any single scale of observation. In this review, we focus on the latter issue and discuss scale translation, which in its broadest sense is transforming data or simulations from one spatiotemporal scale to another. While effective scale translation is not exclusive to shales, but all geologic porous media, the need for it is especially acute in shales given their high degree of heterogeneity. Classical theories like homogenization, while indispensable, fail when scales are not separated. Other methods, like numerical upscaling, scale-translate in only one direction: small to large, but not the reverse, called downscaling. However, the confluence of advances in three areas are bringing challenging problems such as shales within reach: increased computational power and scalable algorithms; high-resolution imaging and multi-modal data acquisition; and machine learning to process massive amounts of data. While these advances equip geoscientists with a wide array of experimental and computational tools, no individual tool can probe the entire gamut of heterogeneity in shales. Their effective use, therefore, requires an ability to bridge between various data types obtained at different scales. The aim of this review is to present a coherent account of computational and experimental methods that may be used to achieve just that, i.e., to perform scale translation. We provide a broader definition of scale translation, one that transcends classical homogenization and upscaling methods, but is consistent with them and accommodates notions like downscaling and data translation. After a brief introduction to homogenization, we review hybrid methods, numerical upscaling and its recent extensions, multiscale computing, high-resolution imaging, and machine learning. We place particular emphasis on multiscale computing and propose an algorithmic framework to bridge between the pore (micro) and Darcy (macro) scales. Throughout the paper, we draw comparisons between the various methods and highlight their (often hidden) similarities, differences, benefits, and pitfalls. We finally conclude with two case studies on shales that exemplify some of the methods presented.

58 GEOSCIENCES↗

Intelligent industrial demand response to increase grid flexibility and reliability: A review

The rapid transition toward renewable energy has introduced challenges in grid stability due to the intermittency of non-dispatchable sources like solar and wind. Industrial Demand Response (IDR) offers a promising, cost-effective solution that adjusts energy consumption patterns to align with supply, increases renewable utilization, and reduces costs. This review provides an updated analysis of IDR, sorting technologies into five categories: energy storage, scheduled energy usage, operational flexibility, on-site generation, and intelligent operations. Energy storage solutions, while requiring little flexibility, often have the longest payback periods. While slightly better, on-site generation also has longer payback periods, ranging from 5 to 20 years or more. Scheduled energy usage, operational flexibility, and intelligent operations allow significant peak reduction at lower capital costs but require greater flexibility. While 15–20 % peak reduction is within the range of all five categories, scheduled energy use and on-site energy generation are shown to have reductions of up to 70–80 % in select scenarios. Combining multiple IDR strategies from these five categories maximizes both financial and operational benefits. Synergistic approaches are shown to enhance grid stability while reducing costs. As the grid evolves, IDR will enable a more flexible, renewable-powered future that will benefit industrial facilities and the broader energy system.

Demand flexibility↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solving the duck curve in a smart grid environment using a non-cooperative game theory and dynamic pricing profiles

With the intermittency that comes with electricity generation from renewables, utilizing dynamic pricing will encourage the demand-side to respond in a smart way that would minimize the electricity costs and flatten the net electricity demand curve. Determining the optimal dynamic pricing profile that would leverage distributed storage to flatten the curve is a novel idea that needs to be studied. Moreover, the economic feasibility of utilizing distributed electrical energy storage is still not given in the literature. Therefore, in this paper, a novel way of solving a citywide dynamic model using a bilevel programming algorithm is introduced. The problem is developed as a novel non-cooperative Stackelberg game that utilizes air-conditioning systems and electrical storage through the end-users to determine the optimal dynamic pricing profile. The results show that the combined effect of utilizing demand-side air-conditioning systems and distributed storage together can flatten the curve while employing the optimal dynamic pricing profile. An economic study is performed to determine the economic feasibility of 20 different cases with different battery designs and the level of solar penetration. Three metrics were used to evaluate the economic performance of each case: the levelized cost of storage, the levelized cost of energy, and the simple payback period. Most cases had levelized cost of storage values lower than 0.457 $/kWh, which is the lower bound available in the literature. Seven out of 16 cases have a simple payback period shorter than the lifetime of the system (25 years). The case with a 100 MW PV power plant and a battery storage of size 597 MWh, was found to be the most promising case with a simple payback period of 12.71 years for the photovoltaic plant and 19.86 years for the demand-side investments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗

Forecasting Solar-Thermal Systems Performance under Transient Operation Using a Data-Driven Machine Learning Approach Based on the Deep Operator Network Architecture

Modeling and prediction of the dynamic behavior of thermal systems operating under intermittent energy input and variable load requirements represent one of the greatest challenges in the development of efficient and reliable renewable-based power generation technologies. In this work, a data-driven machine learning modeling framework was developed based on a modified version of the Deep Operator Network architecture where the time coordinate in the trunk net is replaced with historical data of the predicting quantity. The modeling framework can be used to accurately predict the performance of renewable-based energy conversion technologies including wind- and solar-based power plants. This novel framework was applied on a solar-thermal system that consists of a solar collection loop using a flat plate collector, a power generation loop comprising an Organic Rankine Cycle, and a thermal energy storage tank connecting both loops. Variable solar irradiance, air temperature, and power load profiles were used by the Deep Operator Network to predict the State-of-Charge and the efficiency of the thermal system for several days. The results were compared with the State-of-Charge and efficiency functions calculated using a physics-based model. For a simple operation scenario, characterized by a clear sky solar irradiance profile and constant load, the standard deviation in the State-of-Charge prediction by Deep Operator Network is below 0.9% during a seven-day prediction time horizon. For the most realistic operation scenario that considers real solar irradiance and a rough load profile, the maximum standard deviation in the predictions for the State-of-Charge and efficiency are below 6.8% and 2.5%, respectively. A comparison between Deep Operator Network and Long Short Term Memory network was also performed. In general, both networks predict very well the State-of-Charge for different data density conditions; however, a higher accuracy, with a standard deviation below 2.0%, is obtained by the Deep Operator Network during three and half days using sparser training data of 20-minute points. The same accuracy for the State-of-Charge prediction with the Long Short Term Memory network is achieved only for 14 h. Average standard deviations for the State-of-Charge prediction of 1.1% with the Deep Operator Network and 1.5% with the Long Short Term Memory network are obtained for a four-day prediction time using a denser training data of 5-minute points.

DeepONet↗

Integration of cryogenic energy storage with renewables and power plants: Optimal strategies and cost analysis

Energy storage is critical for overcoming challenges associated with the intermittency and the variable availability of renewable sources for decarbonizing the energy sector. Cryogenic energy storage (CES) is of interest due to its high technology readiness level, no geographical limitations, and moderate round-trip efficiency. The time-varying nature of demands and renewable availability needs to be considered at the design and integration stages of energy storage. We develop a mixed-integer nonlinear program (MINLP) model to obtain the energy storage costs on a daily basis for different scenarios that typically arise over an entire year. Using this optimization-based framework, we address key decision-making questions towards energy transition: What is the energy cost when CES is integrated with renewables and power plants? How does each scenario affect the overall energy cost? How much storage is needed for complete transition to renewables? What is the optimal integration towards 100% renewable energy? What are the optimal storage designs for both renewables and fossil-based power generation with current and future energy demands? Here, we discuss different scenarios and solutions to these questions.

25 ENERGY STORAGE↗

THESEUS: A techno-economic design, integration and downselection framework for energy storage

Optimal selection of energy storage technologies is critical to ensure reliable integration of intermittent and often uncertain renewable energy in electricity grids. The consideration of a diverse set of energy storage technologies is required for a more sustainable deployment of energy storage. We present THESEUS (TecHno-Economic framework for Systematic Energy storage Utilization and downSelection), which is a comprehensive framework for the optimal selection, design and operation of energy storage systems. THESEUS includes rigorous models of major energy storage technologies at different maturity levels, such as thermal storage using phase-change materials or molten salt, cryogenic storage, mechanical storage in the form of compressed air and pumped hydro storage, chemical storage using hydrogen, and electrochemical storage in the form of lithium-ion, sodium sulfur and vanadium flow batteries. An illustrative case study on state-wide prospective energy storage shows that storage integration with fossil power plants could reduce the cost of meeting the grid energy demand by 20%, with mechanical storage as the best suited technology. Although high-temperature thermal storage has low storage efficiency, it is optimal for integration with renewable energy plants. In addition, Li-ion batteries are optimal for high ramping but low storage duration requirements. Furthermore, such insights can enable the deployment of both existing and emerging energy storage technologies to facilitate a smooth transition to a clean energy future.

25 ENERGY STORAGE↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

A data-driven model for thermodynamic properties of a steam generator under cycling operation

The varying electricity demand from coal power plants due to the intermittent nature of renewable sources leads to load-follow and on/off operations referred to as cycling. Cycling causes transients of properties such as pressure and temperature within various components of the steam generation system.These transients cause increased damage because of fatigue and creep-fatigue interactions shortening the life of components. An algorithm is developed to identify cycling operations from the gross power data. The data-driven model based on artificial neural networks (ANN) is developed using 10 years data from Coal Creek Station power plant located in North Dakota, USA to estimate properties of the steam generator components during cycling operations. Furthermore, the uniqueness of this model is the ability to predict component properties for the cycling as well as base-load operations and is reported for the first time. The ANN model estimates the component properties, for a given gross power profile and initial conditions, as they vary during cycling operations. As a representative example, the ANN estimates are presented for the superheater outlet pressure, reheater inlet temperature, and flue gas temperature at the air heater inlet. The changes in these variables as a function of the gross power over the time duration are compared with measurements to assess the predictive capability of the model. Mean square errors of 4.49E-04 for superheater outlet pressure, 1.62E-03 for reheater inlet temperature, and 4.14E-04 for flue gas temperature at the air heater inlet were observed.

01 COAL, LIGNITE, AND PEAT↗

Design and experimental testing of a 150 kWh thermal battery using thermosiphons embedded in a concrete matrix for power plant flexible operation

One of the options for achieving the global temperature limitation of 1.5 °C target, for the mitigation of global warming, is based on the better penetration of renewables into the electrical grid. This has imposed a burden to fossil fuel fired power plants since they are required to operate away from their baseload mode to compensate for the inherent intermittence of the renewable power. Integrating energy storage with fossil plants is an option to achieve their needed flexibility. A cost competitive energy storage option for the solution is based on storing sensible heat in concrete. Here, this paper reports research results and development of a thermal battery cell (TBC) capable of operating at temperatures up to 425 °C. A novel concept consisting of a concrete matrix for sensible heat storage, engineered to provide enhanced thermal and mechanical properties, and twenty-two thermosiphon elements, engineered for dual action were designed and fabricated into a single thermal energy storage (TES) module. Research for the development of the components for the TBC was performed in the laboratory. Efficient heat transfer, to/from the storage media, was demonstrated under several charging and discharging conditions with a thermal storage capacity of 150 kWh th and a rapid discharge, making the TBC suitable for fast ramping when integrated with a fossil fuel fired power plant. Efficient radial heat transfer to the concrete was observed due to the well designed spacing and location of thermosiphons in the radial direction. A minimal temperature difference of 2 °C, between the thermosiphons bottom and top was obtained, demonstrating the isothermicity of those elements. An overall end-to-end TBC energy-to-energy round trip efficiency of 70% was achieved.

25 ENERGY STORAGE↗

Nuclear—thermal energy storage configurations for industrial combined heat and power supply—conceptual and thermodynamic study with high temperature gas-cooled reactor

Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.