Assessing high fidelity multi-component models to facilitate safeguards at Gas Centrifuge Enrichment Plants

We report that the International Atomic Energy Agency (IAEA) inspectors routinely carry out environmental sampling (ES) as a verification method. Collection of environmental swipe samples at various locations in Gas Centrifuge Enrichment Facilities (GCEPs) is an important process in detecting misuse of a declared facility and possibly the existence of undeclared nuclear material. These samples are measured for isotopic composition in uranium containing particles by Thermal Ionization Mass Spectrometry (TIMS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Even though ES is highly effective in detecting the absolute value of enrichments and their deviations from the declared values, it cannot explain the cause of those changes. Several potential explanations can serve as possibilities for particles detected above or other than the declared enrichment. These include normal and non-malicious events such as the design of the enrichment cascades, unintentional failures of the machines, or overshoot during startup of a cascade. It can also be the result of deliberate misuse by the facility operators. The primary objective of this work is to understand how these factors affect the enrichments produced by a cascade and quantify anticipated multi-isotopic concentrations for each case. The following methodology is employed to determine signatures at a particular facility. 1) Utilize a new two-dimensional multi-component diffusion code to obtain centrifuge performance data and use that information to design and perform cascade analysis. Compare and contrast the results with previous 1-D radially averaged solutions from the Pancake code. 2) Design a GCEP cascade with the production goal of 19.75% 235 U for each set of machine data above. Investigate two cascade scenarios that include enrichment of natural uranium (NU) feed to 19.75% 235U in a single cascade compared to a two-step process of NU to 5% and then 5% to 19.75%. 3) Simulate the intentional vs. unintentional off-normal scenarios in the cascades to assess the differences in isotopic concentrations. A non-ideal squared-off cascade model developed at the University of Virginia is used to calculate flow rates and isotopic concentrations of the process gas. The analysis is performed using the Rome machine model operated at 600 m/s rotor speed. The upper and lower bounds of normal and abnormal enrichments in a typical facility are used in conjunction with ES results to understand the root causes of such observations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Assessment of the quality of nuclear data for stable oxygen isotopes for Intentional Forensics applications

The Intentional Forensics (IF) project seeks to design a suite of tagging materials that can be used to unobtrusively “barcode” nuclear fuel. The idea being that, if the fuel leaves institutional controls and is later recovered, the “barcode” can be used to determine the provenance of the fuel. The IF project is investigating several schemes for this “barcode” and taggants with tailored isotopic compositions are once leading concept. Recently 18 O was suggested as a potential taggant [IF2023]. This report assesses the quality of 16,17,18 O evaluations in the ENDF/B-VIII.0 library [ENDF8.0]. In a neutron-rich environment such as a nuclear reactor, we are interested in two main processes – neutron scattering and neutron absorption (or capture). For the typical neutron energies encountered in a reactor, absorption is determined exclusively by the neutron radiative capture cross section (in which a neutron is absorbed, and the residual nucleus emits one or more gamma rays). The capture cross sections are described by and can be completely determined from R-matrix parameters in the ENDF evaluations. Therefore, it is sufficient to consider the quality of the neutron resonance part of these evaluations. Neutron scattering is determined mainly by the elastic scattering cross section which is very similar for all oxygen isotopes and is essentially constant until around 100 keV. The cross section varies from 3-4 barns, depending on the isotope, and 16 O has the largest elastic cross section of all isotopes. Therefore, we expect that significant amounts of 17 O and 18 O could diminish the moderating role of oxygen in fuel. We note that, in traditional power reactor, the hydrogen in the coolant water provides the vast majority of the moderation in the reactor, so the impact of 17 O and 18 O in any taggant would be minimal. At higher energies, neutron resonances start to play a role and the R-matrix parameters determine the cross sections. Fig. 1 shows the mass region near stable oxygen isotopes. As nuclei capture neutrons, they transmute into a different isotope, one unit to the right. In particular, 16 O transmutes to 17 O, 17 O transmutes to 18 O and 18 O transmutes to 19 O. 19 O, being unstable, beta decays in 27 s to 19 F. So, even if the 18 O neutron capture data is good, the fact that it transmutes into 19 F may be problematic and needs investigation. Fig. 2 from [NuDat] shows the thermal neutron capture cross sections for all nuclei in the ENDF/B-VII.1 library [ENDF7.1]. Clearly oxygen thermal capture values are quite small compared to other nuclei. Note, there is no 18 O evaluation in the ENDF/B-VII.1 library. In any event, given that neutron capture events lower the reactor reactivity and potentially induce chemical changes in the fuel, we will focus our attention on the capture part of the neutron resonances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards Automated and High-Throughput Quantitative Sizing and Isotopic Analysis of Nanoparticles via Single Particle-ICP-TOF-MS

The work described herein assesses the ability to characterize gold nanoparticles (Au NPs) of 50 and 100 nm, as well as 60 nm silver shelled gold core nanospheres (Au/Ag NPs), for their mass, respective size, and isotopic composition in an automated and unattended fashion. Here, an innovative autosampler was employed to mix and transport the blanks, standards, and samples into a high-efficiency single particle (SP) introduction system for subsequent analysis by inductively coupled plasma–time of flight–mass spectrometry (ICP-TOF-MS). Optimized NP transport efficiency into the ICP-TOF-MS was determined to be >80%. This combination, SP-ICP-TOF-MS, allowed for high-throughput sample analysis. Specifically, 50 total samples (including blanks/standards) were analyzed over 8 h, to provide an accurate characterization of the NPs. This methodology was implemented over the course of 5 days to assess its long-term reproducibility. Impressively, the in-run and day-to-day variation of sample transport is assessed to be 3.54 and 9.52% relative standard deviation (%RSD), respectively. The determination of Au NP size and concentration was of <5% relative difference from the certified values over these time periods. Isotopic characterization of the 107 Ag/ 109 Ag particles (n = 132,630) over the course of the measurements was determined to be 1.0788 ± 0.0030 with high accuracy (0.23% relative difference) when compared to the multi-collector–ICP-MS determination.

36 MATERIALS SCIENCE↗

Position-specific carbon isotopes of Murchison amino acids elucidate extraterrestrial abiotic organic synthesis networks

The Murchison meteorite is a well-studied carbonaceous chondrite with relatively high concentrations of amino acids thought to be endogenous to the meteorite, in part because they are characterized by carbon isotope (δ 13 C) values higher than those typical of terrestrial amino acids. Past studies have proposed that extraterrestrial amino acids in the Murchison meteorite could have formed by Strecker synthesis (for α-amino acids), Michael addition (for β-amino acids), or reductive amination, but a lack of constraints have prevented confident discrimination among these possibilities, or assignment of specific formation pathways to each of several specific amino acids. Position-specific carbon isotope analysis differentiates amongst these mechanisms by relating molecular sites to isotopically distinct carbon sources and by constraining isotope effects associated with elementary chemical reactions. Prior measurements of the position-specific carbon isotopic composition of α-alanine from the Murchison CM chondrite demonstrated that alanine’s high δ 13 C VPDB value is attributable to the amine carbon (δ 13 C VPDB = +142 ± 20‰), consistent with Strecker synthesis drawing on 13 C-rich carbonyl groups in precursors (Chimiak et al., 2021). Here, we measured the δ 13 C composition of fragment ions generated by electron impact ionization of derivatized α-alanine, β-alanine, and aspartic acid from Murchison via gas chromatography-Fourier transform mass spectrometry. α-Alanine’s amine carbon yielded δ 13 C VPDB = +109 ± 21‰, which is consistent with the previously measured value and with formation from 13 C-rich precursors. β-Alanine’s amine carbon presents a lower δ 13 C VPDB = +33 ± 24‰, which supports formation from 13 C-rich precursors but potentially via a Michael addition mechanism rather than Strecker synthesis. Aspartic acid’s amine carbon has δ 13 C VPDB = -14 ± 5‰, suggesting synthesis from precursors distinct from those that generated the alanine isomers. Further, these measurements indicate that Murchison amino acids are a mixture of compounds made from different synthesis mechanisms, though some subsets likely drew on the same substrates; this conclusion highlights the complexity of extraterrestrial organic synthesis networks and the potential of emerging methods of isotope ratio analysis to elucidate the details of those networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Robust Assessment of High-Precision Plutonium Isotopic Analysis by Thermal Ionization Mass Spectrometry [Slides]

TIMS at SRNL • SRNL consolidated analytical laboratories and services into one area – loss of TIMS capability during relocation. • SRNL installed a new Thermo Scientific TRITON Plus TIMS in our Category II Nuclear Facility to re-establish the lab’s TIMS capabilities in Feb. 2024. • Allows for handling, preparation, purification, and analysis of high-level radiological materials within a single location • Pu and U isotopic composition and assay measurement qualification have been priority since installation. • Once the instrument has been qualified, this capability will support internal and external customers.

07 ISOTOPE AND RADIATION SOURCES↗

Microbial ecology and biogeochemistry of hypersaline sediments in Orca Basin

In deep ocean hypersaline basins, the combination of high salinity, unusual ionic composition and anoxic conditions represents significant challenges for microbial life. We used geochemical porewater characterization and DNA sequencing based taxonomic surveys to enable environmental and microbial characterization of anoxic hypersaline sediments and brines in the Orca Basin, the largest brine basin in the Gulf of Mexico. Full-length bacterial 16S rRNA gene clone libraries from hypersaline sediments and the overlying brine were dominated by the uncultured halophilic KB1 lineage, Deltaproteobacteria related to cultured sulfate-reducing halophilic genera, and specific lineages of heterotrophic Bacteroidetes. Archaeal clones were dominated by members of the halophilic methanogen genus Methanohalophilus, and the ammonia-oxidizing Marine Group I (MG-I) within the Thaumarchaeota. Illumina sequencing revealed higher phylum- and subphylum-level complexity, especially in lower-salinity sediments from the Orca Basin slope. Illumina and clone library surveys consistently detected MG-I Thaumarchaeota and halotolerant Deltaproteobacteria in the hypersaline anoxic sediments, but relative abundances of the KB1 lineage differed between the two sequencing methods. The stable isotopic composition of dissolved inorganic carbon and methane in porewater, and sulfate concentrations decreasing downcore indicated methanogenesis and sulfate reduction in the anoxic sediments. While anaerobic microbial processes likely occur at low rates near their maximal salinity thresholds in Orca Basin, long-term accumulation of reaction products leads to high methane concentrations and reducing conditions within the Orca Basin brine and sediments.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric CO 2 estimates for the Miocene to Pleistocene based on foraminiferal $δ^{11}$B at Ocean Drilling Program Sites 806 and 807 in the Western Equatorial Pacific

Constraints on the evolution of atmospheric CO 2 levels throughout Earth's history are foundational to our understanding of past variations in climate. Despite considerable effort, records vary in their temporal and spatial coverage and estimates of past CO 2 levels do not always converge, and therefore new records and proxies are valuable. Here we reconstruct atmospheric CO 2 values across major climate transitions over the past 16 million years using the boron isotopic composition (δ 11 B) of planktic foraminifera from 89 samples obtained from two sites in the West Pacific Warm Pool, Ocean Drilling Program (ODP) Sites 806 and 807, measured using high-precision multi-collector inductively coupled plasma mass spectrometry. We compare our results to published data from ODP Site 872, also in the Western Equatorial Pacific, that goes back to 22 million years ago. These sites are in a region that today is near equilibrium with the atmosphere and are thought to have been in equilibrium with the atmosphere for the interval studied. We show that δ 11 B data from this region are consistent with other boron-based studies. The data show evidence for elevated pCO 2 during the Middle Miocene and Early to Middle Pliocene, and reductions in pCO 2 of ~200 ppm during the Middle Miocene Climate Transition, ~250 ppm during Pliocene Glacial Intensification and ~50 ppm during the Mid-Pleistocene Climate Transition. During the Mid-Pleistocene Transition there is a minimum pCO 2 at marine isotopic stage (MIS) 30. Our results are consistent with a coupling between pCO 2 , temperature and ice sheet expansion from the Miocene to the late Quaternary.

54 ENVIRONMENTAL SCIENCES↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES↗

Paleo-Megadroughts and Abrupt Climate Changes in the Speleothem Records. Final report

This project is motivated by the speleothem isotope records in Asia, which show regional responses in the hydrologic cycle to different climate forcings. Speleothem isotopic records are typically interpreted in terms of local precipitation variations or monsoon intensity. Our study demonstrates that non-local processes also play an important role. We started this project to understand the regional difference in speleothem isotopic composition between the Last Glacial Maximum (LGM) and the present-day. The record in Southwest China showed greater depletion during the LGM compared to those in East China. Our modeling and analysis showed that speleothems record, in addition, large scale changes in atmospheric circulation and moisture transport and their subsequent impact on precipitation. We developed an algorithm to partition total precipitation according to their formation dynamics, namely into frontal and non-frontal precipitation, and showed that the two have different trends and hence different causal mechanism. We then focused our subsequent attention on circulation impacts on precipitation changes. We applied a machine learning algorithm to detect rainbands in the ERA-Interim reanalysis product, and showed that the seasonal migrations of the rainbands are tied to the seasonal migrations of the jet stream, in particular the northerlies of the jet meanders. These northerlies, in turn, are partly topographic Rossby waves excited as the upstream westerlies impinge on the Tibetan Plateau. The seasonal variations of these upstream westerlies thus contribute to the seasonal movements of the rainbands and regional precipitation changes. Our analysis of the modern precipitation isotope record further confirms the importance of jet stream changes in the isotopic variations and shows that isotope-enriched years have reduced summer seasonality, with less pronounced northward migration of the jet.

54 ENVIRONMENTAL SCIENCES↗

Lithium isotope analysis on the Neoma MS/MS MC-ICP-MS

Accurate and precise lithium isotopic composition measurements are achieved on the Neoma MS/MS after careful tuning of the prefilter lenses to allow both Li ion beams to pass through unimpeded.

07 ISOTOPE AND RADIATION SOURCES↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Chemical and isotopic evolution of flowback fluids from the Utica Gas Shale Play, Eastern Ohio USA

For this work, hydraulic fracturing flowback fluids were collected from two Utica/Point Pleasant well pads in eastern Ohio. One site was in the wet gas zone (UPPW), while the site ~50 km south consisted of four wells on the same pad in the dry gas zone (UPPS). Samples of input fluids also were collected before and during hydraulic fracturing. Flowback fluids are Na-Ca-Cl brines with total dissolved salt (TDS) concentrations that increase over several months from ~100 to 200 g/L. The slightly higher TDS of the dry gas fluids are in part due to recycled flowback used as input fluids, and in part due to lower volume of water used in hydraulic fracturing. Concentrations of most major ions (Ca 2+ , Mg 2+ , Na + , Sr2 + , Fe, Mn, Cl – , Br – ) are similar for the five wells sampled, although small but systematic changes occur in the major element ratios over time. Most notably, an increase in the Sr/Cl ratio corresponds to an increase in the 87 Sr/ 86 Sr ratio in the fluids, suggesting interactions with a more radiogenic Sr source in the subsurface. Dissolved Ba concentrations and Ra activities were different between the two sites, reflecting a high SO 4 2– fluid used at the UPPW site, and water-rock reactions occurring during hydraulic fracturing at the UPPS site. Water oxygen (δ 18 O) and hydrogen (δD) isotopes for input fluids used in the UPPW4 well and fresh water used for the UPPS wells fall on the Global Meteoric waterline (GMWL). Flowback fluids from both sites are relatively enriched in δ 18 O and δD compared to the input, but do not appear to follow a simple mixing trend, suggesting reaction and isotopic exchange with carbonates and fractionation due to imbibition in the rock. Cl isotopes, δ 37 Cl in the FP fluids varied from ~ –0.43 to +0.13‰, the largest variation was observed in the earlier stages of flowback, while in the later stages δ 37 Cl exhibited a small but systematic increase over time, suggesting diffusion control of isotopic composition. Some of the trace species measured (dissolved Fe, Mn, thiosulfate and organic acids) do not follow the same trends as the major ions, suggesting contributions from input fluids, or microbially mediated reactions are exerting control on their concentrations. Input water chemistry exerts an important control on the Sr and Ba concentrations in flowback water. High SO 4 2– in the input fluids used for hydraulically fracturing the wet gas well leads to precipitation of barite-celestite in flowback fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lignin lags, leads, or limits the decomposition of litter and soil organic carbon

Lignin’s role in litter and soil organic carbon (SOC) decomposition remains contentious. Lignin decomposition was traditionally thought to increase during midstage litter decomposition, when cellulose occlusion by lignin began to limit mass loss. Alternatively, lignin decomposition could be greatest in fresh litter as a consequence of co-metabolism, and lignin might decompose faster than bulk SOC. To test these competing hypotheses, we incubated 10 forest soils with C 4 grass litter (amended with 13 C-labeled or unlabeled lignin) over 2 yr and measured soil respiration and its isotope composition. Early lignin decomposition was greatest in 5 of 10 soils, consistent with the co-metabolism hypothesis. However, lignin decomposition peaked 6–24 months later in the other five soils, consistent with the substrate-limitation hypothesis; these soils were highly acidic. Rates of lignin, litter, and SOC decomposition tended to converge over time. Cumulative lignin decomposition was never greater than SOC decomposition; lignin decomposition was significantly lower than SOC decomposition in six soils. Net nitrogen mineralization predicted lignin decomposition ratios relative to litter and SOC. Although the onset of lignin decomposition can indeed be rapid, lignin still presents a likely bottleneck in litter and SOC decomposition, meriting a reconsideration of lignin’s role in modern decomposition paradigms.

54 ENVIRONMENTAL SCIENCES↗

Generation of Bright Soft X-ray Laser Beams (Final Report)

The project goal was to demonstrate new compact soft x-ray lasers emitting high energy ultrashort pulses at shorter wavelengths and increased repetition rates by amplification in atomic transitions in high density laser-created plasmas. To demonstrate these lasers we developed new high power solid state lasers. The project succeeded in demonstrating the shortest wavelength compact soft x-ray laser to date, 6.85 nm wavelength, and the highest repetition rate table-top soft x-ray laser, 400 Hz. We also applied these compact soft x-ray laser sources to determine the composition of materials with nanoscale resolution using a new technique that combines soft x-ray laser ablation with mass spectrometry, and we demonstrated that these lasers are capable of acquiring nanoscale resolution holograms with picosecond time resolution. The combination of an increased pumping efficiency with increased repetition rates can yield soft x-ray laser beams with an unprecedented average power on a table-top for applications demanding a high photon flux. We have demonstrated that the efficiency of plasma-based laser-pumped soft x-ray lasers can be significantly increased by detailed pulse shaping of the pump laser using a new pulse synthesizer. Results include the demonstration of 18.9 nm wavelength laser operation at a record 400 Hz repetition rate, and the extension of repetitive gain-saturated plasma-based table-top x-ray lasers to the shortest wavelength to date, 6.85 nm. Laser amplification was also observed at wavelengths as short at 5.8 nm by isolectronic scaling in Ni-like lanthanide ions. We have also conducted simulations to explore the possibility of demonstrating gain saturated atomic x-ray lasers near the carbon K-edge, in the “carbon window” for the first time. The work conducted under this program also includes the use of compact soft x-ray lasers in applications to problems of chemical interest, such as isotopic composition mapping of micron-size uranium particles with nanoscale resolution, and nanoscale resolution depth profiling analysis of CoNCN-coated electrodes for water oxidation catalysis. We also demonstrated single-shot high resolution soft x-ray Fourier transform holography over a broad 7 µm diameter field of view with ~ 5 ps temporal resolution.

74 ATOMIC AND MOLECULAR PHYSICS↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

Leaf 13 C data constrain the uncertainty of the carbon dynamics of temperate forest ecosystems

Stable carbon isotope discrimination occurred in plant biophysical and biogeochemical processes can help understand plant physiology and soil biogeochemistry with respect to carbon cycling. Here, we incorporated the photosynthetic carbon isotope discrimination into a process-based land surface model (iTEM) to test if stable carbon isotope composition (δ 13 C) can impose additional constraint on model parameters. Sequential data assimilation was implemented at six eddy covariance flux tower sites using carbon flux observations including gross primary productivity (GPP) and net ecosystem exchange (NEE) with and without considering foliar δ 13 C (δ 13 C f ) measurement constraints, respectively. Our model-data fusion showed that δ 13 C f can provide useful constraint on photosynthetic (V cmax25 , the maximum rate of carboxylation at 25°C) and stomatal (g1, the slope of stomatal function) parameters as well as the posterior carbon fluxes. When including δ 13 C f measurement, g1 spatially varies among the six sites and is significantly correlated with annual precipitation. We incorporated the statistical relationship between g1 and annual precipitation into iTEM, which is then used to quantify the regional carbon dynamic in temperate forest ecosystems of the Northern Hemisphere. Compared with the simulation only conditioned on carbon flux observations, regional carbon flux estimations performed slightly better against the FLUXCOM products and the uncertainties of modeled carbon fluxes were reduced by 27%. Our study demonstrated that δ 13 C f data constrains carbon flux uncertainties across space.