Search NASA⌕ Search

SEARCH · Search NASA

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Improving the electrostatic design of the Jefferson Lab 300 kV DC photogun

The 300 kV DC high voltage photogun at Jefferson Lab was redesigned to deliver electron beams with a much higher bunch charge and improved beam properties. The original design provided only a modest longitudinal electric field ( E z ) at the photocathode, which limited the achievable extracted bunch charge. To reach the bunch charge goal of approximately few nC with 75 ps full-width at half-maximum Gaussian laser pulse width, the existing DC high voltage photogun electrodes and anode–cathode gap were modified to increase E z at the photocathode. In addition, the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the non-symmetric nature of the inverted insulator photogun design. We present the electrostatic design of the original photogun and the modified photogun and beam dynamics simulations that predict vastly improved performance. We also quantify the impact of the photocathode recess on beam quality, where recess describes the actual location of the photocathode inside the photogun cathode electrode relative to the intended location. A photocathode unintentionally recessed/misplaced by sub-millimeter distance can significantly impact the downstream beam size.

47 OTHER INSTRUMENTATION↗

CLAS+FROST: new generation of photoproduction experiments at Jefferson Lab

A large part of the experimental program in Hall B of the Jefferson Lab is dedicated to baryon spectroscopy. Photoproduction experiments are essential part of this program. CEBAF Large Acceptance Spectrometer (CLAS) and availability of circularly and linearly polarized tagged photon beams provide unique conditions for this type of experiments. Recent addition of the Frozen Spin Target (FROST) gives a remarkable opportunity to measure double and triple polarization observables for different pseudo-scalar meson photoproduction processes. For the first time, a complete or nearly complete experiment becomes possible and will allow model independent extraction of the reaction amplitude. An overview of the experiment and its current status is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Future (transverse) spin physics at Jefferson Lab

The studies of GPDs and TMDs with polarizations at 6 GeV at Jefferson Lab have already shown great promises. The 12-GeV spin program will significantly advance our knowledge about the three-dimensional structure of the nucleon in the valence quark region, and the QCD dynamics responsible for the structure. With the possibility of a future electron ion collider with polarized beams, the next frontier of QCD will be reached. This proceeding paper will focus on future studies of TMDs using polarizations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of Nuclear Physics at Jefferson Lab

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for experimental nuclear physics. This facility is presently being upgraded, which will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gradient limiting defects in 9-cell cavities EP processed and RF tested at Jefferson Lab

Several 9-cell cavities processed by electropolishing (EP) and RF tested at Jefferson Lab are found to be quench-limited. Pass-band mode excitation measurements provide the first clue of candidate cells responsible for the limit. A second RF test with thermometers attached to the equator region of candidate cells (typically only 2 candidates) reveals a hot spot caused by excessive heating of the operational defect and hence determines its location. High resolution optical tools inspect the RF surface corresponding to the hot spot to image and document the defect. All defects in cavities quench limited < 21 MV/m are sub-mm sized irregularities near but outside of the equator EBW. In contrast, no observable irregularities are found in some other cavities that are quench-limited ~ 30 MV/m. These two types of quench limited cavities have different response to a second EP processing. In this paper, we will give a summary of the test results and attempt to catalog the observed defects. An equation for quench gradient is given.

43 PARTICLE ACCELERATORS↗

Jefferson Lab CLAS12 Superconducting Solenoid magnet Requirements and Design Evolution

As part of the Jefferson Lab 12GeV accelerator upgrade project, one of the experimental halls (Hall B) requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. In this presentation the physics requirements for the 5 T solenoid magnet, design constraints, conductor decision, and cooling choice will be discussed. The various design iterations to meet the specification will also be discussed in this presentation.

Rajput-Ghoshal, Renuka↗

Progress in Offline Software for the GlueX Experiment at Jefferson Lab

The GlueX Experiment will begin taking data next year at CEBAF at Jefferson Lab. CEBAF is being upgraded to deliver 12 GeV electrons and GlueX will receive a secondary, tagged photon beam with linear polarization in a new experimental hall, Hall D. Over the past few years the collaboration has worked preparing offline software to do event simulation, event reconstruction, and data analysis in preparation for the beginning of operations. Progress in these areas will be presented along with a description of data challenges completed to test scaling of computing infrastructure.

Ito, Mark↗

Accurate, low-energy Compton polarimetry for Hall C at Jefferson Lab

A new Compton polarimeter has recently been commissioned in Hall C at Jefferson Lab in Newport News, VA, to provide a non-invasive, continuous measurement of electron beam polarization. The new Compton polarimeter is currently measuring electron beam polarization for Qweak, an experiment with a strict error budget allowing a combined statistical and systematic error of only $\pm1\%$ for beam polarization. Using well-established techniques we are able to determine electron beam polarization by measuring the scattering asymmetry of both the backscattered photons and the scattered electrons. Although the photon and electron detectors provide somewhat independent measurements they share the common systematic of the laser polarization. I discuss the optical setup for the photon target used in the Compton polarimeter and recent efforts in reducing systematic error in determination of laser polarization.

Jones, Donald↗

Studies Of Coherent Synchrotron Radiation And Longitudinal Space Charge In The Jefferson Lab FEL Driver

The Jefferson Laboratory IR FEL Driver provides an ideal test bed for studying a variety of beam dynamical effects. Recent studies focused on characterizing the impact of coherent synchrotron radiation (CSR) with the goal of benchmarking measurements with simulation. Following measurements to characterize the beam, we quantitatively characterized energy extraction via CSR by measuring beam position at a dispersed location as a function of bunch compression. In addition to operating with the beam on the rising part of the linac RF waveform, measurements were also made while accelerating on the falling part. For each, the full compression point was moved along the backleg of the machine and the response of the beam (distribution, extracted energy) measured. Initial results of start-to-end simulations using a 1D CSR algorithm show remarkably good agreement with measurements. A subsequent experiment established lasing with the beam accelerated on the falling side of the RF waveform in conjunction with positive momentum compaction (R56) to compress the bunch. The success of this experiment motivated the design of a modified CEBAF-style arc with control of CSR and microbunching effects.

Tennant, Christopher D.↗

Proposed measurement of tagged deep inelastic scattering in Hall A of Jefferson lab

A tagged deep inelastic scattering (TDIS) experiment is planned for Hall A of Jefferson Lab, which will probe the mesonic content of the nucleon directly. Low momentum recoiling (and spectator) protons will be measured in coincidence with electrons scattered in a deep inelastic regime from hydrogen (and deuterium) targets, covering kinematics of 8 < W2 < 18 GeV2, 1 < Q2 < 3 (GeV/c)2 and 0:05 < x < 0:2. The tagging technique will help identify scattering from partons in the meson cloud and provide access to the pion structure function via the Sullivan process. The experiment will yield the first TDIS results in the valence regime, for both proton and neutron targets. We present here an overview of the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A proposed VUV oscillator-based FEL upgrade at Jefferson Lab

Advances in superconducting linac technology offer the possibility of an upgrade of the Jefferson Lab Free Electron Laser (JLab FEL) facility to an oscillator-based VUV-FEL that would produce 6 x 10{sup 12} coherent 100 eV photons per pulse at multi-MHz repetition rates in the fundamental. At present JLab operates a pair of oscillator-based continuous-wave Free Electron Lasers (FELs) as a linac-based next generation light source in the IR and UV, with sub-picosecond pulses up to 75 MHz. Harmonics upwards of 10 eV are produced and the fully coherent nature of the source results in peak and average brightness values that are several orders of magnitude higher than storage rings. The accelerator uses an energy recovered linac design for efficiency of operation. New style superconducting linac cryomodules with higher gradient, combined with a new injector and beam transport system allow the development of the FEL to higher photon energies.

43 PARTICLE ACCELERATORS↗

NaI (Tl) calorimeter calibration and simulation for Coulomb sum rule experiment in Hall-A at Jefferson Lab

A precision measurment of inclusive electron scattering cross sections is carried out at Jefferson Lab in the quasi-elastic region for 4 He, 12 C, 56 Fe and 208 Pb targets. The longitudinal (R L ) and transverse (R T ) response functions of the nucleon need to be extracted precisely in the momentum transfer range 0.55 GeV/c ≤ |q| ≤ 1.0 GeV/c. To achieve the above goal, a NaI (Tl) calorimeter is used to distinguish good electrons from background, including pions and low energy electrons rescattered from the walls of the spectrometer magnets. Due to a large set of kinematics and changes in HV settings, a number of calibrations are performed for the NaI (Tl) detector. Corrections for a few blocks of NaI (Tl) with bad or no signal are applied. The resolution of the NaI (Tl) detector after calibration reached ɤE/√E ≈ 3% at E = 1 GeV. The performance of the NaI (Tl) detector is compared with a simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of high gradient SRF R&D for ILC cavities at Jefferson Lab

We report the progress on high gradient R&D of ILC cavities at Jefferson Lab (JLab) since the Beijing workshop. Routine 9-cell cavity electropolishing (EP) processing and RF testing has been enhanced with added surface mapping and T-mapping instrumentations. 12 new 9-cell cavities (10 of them are baseline fine-grain TESLA-shape cavities: 5 built by ACCEL/Research Instruments, 4 by AES and 1 by JLab; 2 of them are alternative cavities: 1 fine-grain ICHIRO-shape cavity built by KEK/Japan industry and 1 large-grain TESLA-shape cavity built by JLab) are EP processed and tested. 76 EP cycles are accumulated, corresponding to more than 200 hours of active EP time. Field emission (FE) and quench behaviors of electropolished 9-cell cavities are studied. EP process continues to be optimized, resulting in advanced procedures and hence improved cavity performance. Several 9-cell cavities reached 35 MV/m after the first light EP processing. FE-free performance has been demonstrated in 9-cell cavities in 35-40 MV/m range. 1-cell cavity studies explore new techniques for defect removal as well as advanced integrated cavity processing. Surface studies of niobium samples electropolished together with real cavities provide new insight into the nature of field emitters. Close cooperation with the US cavity fabrication industry has been undertaking with the successful achievement of 41 MV/m for the first time in a 9-cell ILC cavity built by AES. As the size of the data set grows, it is now possible to construct gradient yield curves, from which one can see that significant progress has been made in raising the high gradient yield.

43 PARTICLE ACCELERATORS↗

The JLab Eta Factory (JEF) experiment at Jefferson Lab

The GlueX spectrometer is a large acceptance spectrometer installed in Hall~D at Jefferson Lab with good coverage for both charged and neutral particles. In particular photons in the forward direction are detected using the Forward Calorimeter, an array of lead glass blocks. The main physics program is to search for evidence for hybrid mesons. The recently-approved JLab Eta Factory (JEF) experiment extends the GlueX physics program to study rare decays of ? mesons with a particular emphasis on the ???0?? channel. In addition to probing O(p6) terms in chiral perturbation theory, this channel can be used to search for evidence for lepto-phobic dark matter. A potential extension to the Standard Model posits a dark gauge boson (B) that couples predominately with quarks and can be observed in the ???B, B??0? decay chain. The JEF program also plans to search for C-violating/P-conserving decays of the ? meson. In order to achieve the requisite resolution to observe these rare channels, this experiment calls for an upgrade to the existing GlueX Forward Calorimeter. After a brief description of the GlueX detector, I will focus on the JEF program with a particular emphasis on the B-boson search and I will discuss plans for the future.

Taylor, Simon↗

Precision Compton polarimetry for the QWeak experiment at Jefferson Lab

The Q Weak experiment, scheduled to run in 2010-2012 in Hall C at Jefferson Lab, will measure the parity-violating asymmetry in elastic electron-proton scattering at 1.1 GeV to determine the weak charge of the proton, Q{sub Weak}{sup p} = 1 - 4 sin{sup 2} {theta}{sub W}. The dominant experimental systematic uncertainty will be the knowledge of the electron beam polarization. With a new Compton polarimeter we aim to measure the beam polarization with a statistical precision of 1% in one hour and a systematic uncertainty of 1%. A low-gain Fabry-Perot cavity laser system provides the circularly polarized photons. The scattered electrons are detected in radiation-hard diamond strip detectors, and form the basis for a coincidence trigger using distributed logic boards. The photon detector uses a fast, undoped CsI crystal with simultaneous sampling and integrating read-out. Coincident events are used to cross-calibrate the photon and electron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

12 GeV Upgrade Jefferson Lab

I will discuss the program and opportunities to measure Generalized Partons Distributions (GPDs) at Jefferson Lab with the 12 GeV upgrade of the CEBAF accelerator. At the energy-doubled CEBAF the increased kinematics coverage will allow probing these new distributions functions in the entire valence quark regime. The experimental equipment planned for these measurements will be discussed as well.

Burkert, Volker↗