Search NASA⌕ Search

SEARCH · Search NASA

Results for “LEAKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Aerosol-Based Sealant for Air Ducts Technology

Aerosol-based sealant can be used to seal air duct leaks. This is done by pressurizing the ducts and injecting the spray sealant. This technology can be used to seal small (up to ½-inch diameter) and inaccessible duct leaks hidden in wall, ceiling, and floor cavities (Ternes and Hwang2001). The aerosol sealant itself is a nontoxic vinyl polymer (Kallett et al. 2000). The technology is a proprietary duct-sealing method developed jointly by the U.S. government and Aeroseal, the company that holds an exclusive license to use the technology (Ternes and Hwang 2001). Specifically, Lawrence Berkeley National Laboratory developed the aerosol-spray technology with funding from the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency, and others while Aeroseal developed the current version of the equipment and software to apply the technology in practice (Ternes and Hwang 2001).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing and Qualification of Molybdenum Subcapsule Welds for MiniFuel Experiments

This report documents the testing and qualification efforts for welding molybdenum components to support MiniFuel irradiation campaigns. Other details such as general weld parameters, weld joint geometries, and performance limits are also provided in this report. The American Welding Society’s specifications were used to select the nondestructive and destructive tests, which include: gross and fine leak testing, internal pressure proof testing, and creating metallographic mounts of welds. Leak testing and metallographic mounts provide qualitative information about the weld integrity, while the proof testing indicated pressure/usage limits of the molybdenum subcapsule. Based on the testing results provided in the is report, the capsule can be exposed to an internal pressure of at least 20.7 MPa (3000 psi). A sealed capsules is also capable of withstanding the 3.2 MPa (468 psi) external hydrostatic operating pressure of the High Flux Isotope Reactor.

42 ENGINEERING↗

Predictive Self-Healing Seals for Gas Transmission

Damaged elastomeric diaphragms within pneumatic controllers used in the oil and gas industry lead to an unintended release of methane. Self-healing microvascular materials capable of healing various types of damage have been fabricated. These microvascular materials are designed to replace currently available commercial diaphragms found in pneumatic controllers and provide a solution to reduce unintended methane leaks. This project demonstrated the ability of these materials to reduce methane release by more than 80% in lab and pilot settings. Additionally, ML approaches successfully identified leaking systems based on training using synthetic and real data.

03 NATURAL GAS↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 5.1. The most significant changes for HyRAM+ version 5.1 from HyRAM+ version 5.0 are updated default leak frequency values for propane, new default component counts for different fuel types, and an improved fuel specification view in the graphical user interface.

02 PETROLEUM↗

Capability for time-resolved diffraction for material phase in extreme conditions (Q2 FY24 Report)

After a series of development experiments, a new x-ray diffraction diagnostic called FIDDLE (Flexible Imaging Diffraction Diagnostic for Laser Experiments) has been designed, built, and fielded on four shots at NIF. Here we document the initial performance of FIDDLE fielded as the detector in the time-resolved x-ray diffraction experimental platform. Early challenges with EMP have been documented using offline testing in the Target Diagnostics Factory to identify EMP leaks. These techniques were used to guide the application of shielding to weak spots where EM radiation was able to penetrate inside the diagnostic. Application of shielding was found to be effective at reducing EMP leaks, enabling detection of x-ray diffraction on three temporally separated frames during a high pressure (~1Mbar) experiment where lead (Pb) was observed to undergo a phase transition from HCP to BCC.

36 MATERIALS SCIENCE↗

Framework for Characterizing Strain in the Vicinity of Leaky Reservoirs

The identification of leaks in the vicinity of reservoirs is critical to determining the feasibility of long-term geologic storage of CO2, methane, wastewater and other fluids. We have established a series of basic reservoir leakage scenarios and performed numerical analysis to characterize the associated pressure and strain fields created from injection into these leaky reservoir settings, as well from ambient loads, such as barometric pressure and earth tides. The end-member conceptual models evaluated include injection and ambient loads applied to: 1) a thin, horizontal layer with no leakage pathways (baseline), 2) a thin layer with a vertical conduit to the surface (e.g., a leaky fault or abandoned well) and 3) a thin layer with a conduit to an overlying aquifer. The pressure and strain fields are sensitive to the reservoir and confining unit geometry, material properties, the distribution, composition and compressibility of the pore fluid and the type of applied load (e.g., constant vs. cyclical injection, barometric pressure fluctuations, earth tides, etc.). Initial results from the numerical analyses indicate that an induced pressure change of 1 MPa in a formation at 1 km depth with a Young’s modulus of 10 GPa is sufficient to create vertical and horizontal strain signals as high as 2 με at a depth of 100 m. The signals predicted from leaky conditions compared to an intact reservoir differ by as much as 0.2 με in magnitude and evolve at different rates. We have developed instruments capable of measuring vertical and horizontal strain at a resolution of better than 5 nε and have recorded repeatable strain signals at 30 m depth in response to wastewater injection into the Avant field in Oklahoma. Based on these findings, strain signals predicted in the shallow subsurface (< 100 m) with numerical analysis are expected to be measurable, and this signal may be inverted to characterize the location and magnitude of leaks, as well as to characterize the geometry and hydromechanical properties of the formation and overlying confining units. This suggests that shallow strain measurements could be a cost effective method for characterizing and monitoring gas storage projects.

Robert, Moak↗

CCUS 2024, Interpreting the strain tensor Larry Murdoch Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring during CCUS. We have demonstrated this method by deploying strainmeters at shallow depths (30 to 40m) and then conducting injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. We have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS. Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and our objective was to evaluate opportunities for strain monitoring during characterization and monitoring for CCUS. Our approach was to deploy strainmeters at shallow depths (30 to 40m) and then conduct injection well tests in an underlying reservoir at 530m depth. The results indicate that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. In conclusion, we have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS.

Murdoch, Larry↗

Recent Developments in Sensor Technologies for Enabling the Hydrogen Economy

Efforts to create a sustainable hydrogen economy are gaining momentum as governments all over the world are investing in hydrogen production, storage, distribution, and delivery technologies to develop a hydrogen infrastructure. This involves transporting hydrogen in gaseous or liquid form or using carrier gases such as methane, ammonia, or mixtures of methane and hydrogen. Hydrogen is a colorless, odorless gas and can easily leak into the atmosphere leading to economic loss and safety concerns. Therefore, deployment of robust low-cost sensors for various scenarios involving hydrogen is of paramount importance. Here, we review some recent developments in hydrogen sensors for applications such as leak detection, safety, process monitoring in production, transport and use scenarios. The status of methane and ammonia sensors is covered due to their important role in hydrogen production and transportation using existing natural gas and ammonia infrastructure. This review further provides an overview of existing commercial hydrogen sensors and also addresses the potential for hydrogen as an interferent gas for currently used sensors. This review can help developers and users make informed decisions about how to drive hydrogen sensor technology forward and to incorporate hydrogen sensors into the various hydrogen deployment projects in the coming decade.

08 HYDROGEN↗

Risk Analysis of a Hydrogen Generation Facility near a Nuclear Power Plant

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a hydrogen production facility in close proximity to an NPP. A 100 MW, 500 MW, and 1,000 MW facility are evaluated herein. Previous analyses have evaluated preliminary designs of a hydrogen production facility in a conservative manner to determine if it is feasible to co-locate the facility within 1 km of an NPP. This analysis specifically evaluates the risk components of different hydrogen production facility designs, including the likelihood of a leak within the system and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure given adequate distance from the plant.

08 HYDROGEN↗

Risk Analysis of a 100 MW Hydrogen Generation Facility near a Nuclear Power Plant

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a 100 MW hydrogen production facility in close proximity to an NPP. Previous analyses have evaluated preliminary designs of a hydrogen production facility in a conservative manner to determine if it is feasible to co-locate the facility within 1 km of an NPP. This analysis specifically evaluates the risk components of a 100 MW hydrogen production facility design, including the likelihood of a leak within the system and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure given adequate distance from the plant.

08 HYDROGEN↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Compressor Station Differential Risk Assessment for Hydrogen and Natural Gas Blends

Blending hydrogen into existing natural gas pipelines is a current initiative for large-scale hydrogen deployment in the United States. Understanding changes in hazards and risk for fuel blends can help inform regulations. A differential risk assessment was conducted to understand how the safety profile of fires and unignited flammable plumes of leaking fuel would change based on blend composition. The area affected by harmful heat fluxes from jet fires was found to be larger for blends with more natural gas in them, while the distance affected by unignited flammable fuel concentrations was found to be larger for blends with more hydrogen in them. Component leak frequencies and ignition probabilities greatly impact both heat flux risk and the flammable plume risk. The collection of additional blend-specific industry data could help understand which assumptions are most valid to make when calculating risk.

08 HYDROGEN↗

MR13A-3183: Microbial and Geochemical Characterization of Groundwater: Implications for Underground Hydrogen Storage Leakage

Underground hydrogen storage (UHS) in geological formations is a key element of the clean energy transition as it enables the decarbonization of the transportation and industrial sectors by decoupling hydrogen production and storage. UHS has many benefits, including low cost, much wider availability, large storage capacity, well-established infrastructure, and increased safety because of geological sealing capabilities. However, the impact of hydrogen (H2) biogeochemical interactions in the presence of subsurface microorganisms is largely neglected from UHS perspectives. These interactions might affect the effectiveness of storage and can even cause H2 to leak into the shallow aquifers. Leakage of H2 into groundwater can change the geochemistry and induce several microbial-driven processes. Microorganisms, such as sulfate-reducers, are naturally abundant in groundwater and consume H2 to produce hydrogen sulfide (H2S), which can contaminate the freshwater drinking groundwater and cause damage to infrastructure. Hydrogen leakage can also trigger microbial reactions responsible for metal mobility, which can impact the water quality. However, the kinetics of these reactions and the temporal impact of hydrogen leakage in groundwater are still unknown. Therefore, a time series hydrogen-groundwater interaction experiment was conducted, and the changes in fluid chemistry and headspace gas composition will be analyzed along with DNA sequencing results to understand the extent and kinetics of biogeochemical reactions that occur if hydrogen leaks into groundwater. In the experiments, Ultra High Purity (UHP) hydrogen gas will be injected into glass vials with groundwater samples, for a designated time period. For each glass-sealed vial, 16S rRNA gene sequencing, IC, ICP-MS, and GC-TCD will be performed. The experiments provide insights into plausible impacts of hydrogen leakage into shallow drinking water aquifers.

Clark, Allison [West Virginia University (WVU)]↗

Technical Justifications for Outdoor Bulk Gaseous Hydrogen Storage Setback Distances

Setback distances define a prescribed distance between a potentially hazardous system and different types of other systems, people, buildings, or materials that may be exposed to that hazard. Riskinformed separation distances are not meant to completely eliminate risk, but rather to limit the risk to an acceptable level. A sensitivity study of risk suggested that a leak size of 3% of the pipe cross-sectional area would be a conservative but reasonable basis. Calculation of the setback distances for gaseous hydrogen was done in a deterministic manner, using a selected leak size and harm criteria for each group of exposures. Harm criteria have been updated to better reflect the exposure types under consideration, and to be consistent with setback distances for liquid hydrogen. The resulting setback distance values are primarily driven by radiative heat flux values for all exposure groups. For the typical pipe sizes, the setback distances slightly increase compared to the previous version of NFPA 2.

08 HYDROGEN↗

Quantum Enhanced Fiber Sensing for Oil and Gas Applications (Final Technical Report)

The major goal of the project was to develop a quantum sensing approach compatible with current infrastructure in the oil and gas industry that could provide a quantum enhancement, with a focus towards pipeline leak detection. The proposed approach to achieving this goal consisted of the use of quantum states of light to enhance the sensitivity of fiber optic sensors beyond the classical limit. To address the limitations of existing commercial leak detection, the project focused on the study of two technologies: distributed acoustic sensors (DAS) and fiber Bragg grating (FBG)-based sensors. The initial phase of the project centered around the identification and mitigation of dominant sources of classical noise to enable operation at the classical shot noise limit (SNL). The second phase focused on the use of quantum resources to obtain sensitivities beyond the classical SNL. The final phase sought to combine quantum noise reduction techniques with advanced dynamical classical noise cancelation approaches.

02 PETROLEUM↗

Assessing the release, transport, and retention of radioactive aerosols from hypothetical breaches in spent fuel storage canisters

Interim dry storage of spent nuclear fuel involves storing the fuel in welded stainless-steel canisters. Under certain conditions, the canisters could be subjected to environments that may promote stress corrosion cracking leading to a risk of breach and release of aerosol-sized particulate from the interior of the canister to the external environment through the crack. Research is currently under way by several laboratories to better understand the formation and propagation of stress corrosion cracks, however little work has been done to quantitatively assess the potential aerosol release. The purpose of the present work is to introduce a reliable generic numerical model for prediction of aerosol transport, deposition, and plugging in leak paths similar to stress corrosion cracks, while accounting for potential plugging from particle deposition. The model is dynamic (changing leak path geometry due to plugging) and it relies on the numerical solution of the aerosol transport equation in one dimension using finite differences. The model’s capabilities were also incorporated into a Graphical User Interface (GUI) that was developed to enhance user accessibility. Model validation efforts presented in this paper compare the model’s predictions with recent experimental data from Sandia National Laboratories (SNL) and results available in literature. We expect this model to improve the accuracy of consequence assessments and reduce the uncertainty of radiological consequence estimations in the remote event of a through-wall breach in dry cask storage systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment

Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch 4 /h and 2.9 kg Ch 4 /h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of –67% to 200%) with individual errors between –90% and 831%, which reduced to –79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

42 ENGINEERING↗