Search NASA⌕ Search

SEARCH · Search NASA

Results for “LEVEL WIDTHS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Analysis of the influence of external biasing on Texas Helimak turbulence

We analyze alterations on the electrostatic turbulence in experiments with imposed bias to control the plasma radial electric field in Texas Helimak (K. W. Gentle and H. He, Plasma Sci. Technol. 10, 284 (2008)), a toroidal plasma device with a one-dimensional equilibrium, magnetic curvature, and shear. Comparing discharges from different biased potentials, we identify, in a roughly uniform gradient region, a continuous variation from low turbulence level and narrower frequency spectra, for negative bias, to high turbulence level and broadband spectra for positive bias. Overall, we distinguish two kinds of perturbed turbulence, classified according to their intensity, spectral, statistical, and recurrence properties. When the bias is positive, the turbulence shows enhanced and broadband spectra with non Gaussian probability distribution functions having noticeable long tails (extreme events) similar to the turbulence in tokamak scrape-off layer. On the other hand, negative bias reduces the turbulence level and decreases the spectrum widths. Also for negative bias, we found large frequency widths whenever the coupling between drift waves and the sheared plasma flow is fast enough to allow the enhancement of sidebands modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PROBING SHOCK PROPERTIES WITH NONTHERMAL X-RAY FILAMENTS IN CAS A

Thin nonthermal X-ray filaments are often seen in young supernova remnants. We used data from the 1 Ms Chandra observation of Cassiopeia A to study spectral properties of some of the filaments in this remnant. For all the cases that we examined, the X-ray spectrum across the filaments hardens, at about 10% level, going outward, while observed filament widths depend only weakly on the photon energy. Using a model that includes radiative cooling, advection, and diffusion of accelerated particles behind the shock, we estimated the magnetic field, turbulence level, and shock obliquity.

79 ASTRONOMY AND ASTROPHYSICS↗

FINE-STRUCTURE Fe II* EMISSION AND RESONANT Mg II EMISSION IN z {approx} 1 STAR-FORMING GALAXIES

We present a study of the prevalence, strength, and kinematics of ultraviolet Fe II and Mg II emission lines in 212 star-forming galaxies at z {approx} 1 selected from the DEEP2 survey. We find Fe II* emission in composite spectra assembled on the basis of different galaxy properties, indicating that Fe II* emission is common at z {approx} 1. In these composites, Fe II* emission is observed at roughly the systemic velocity. At z {approx} 1, we find that the strength of Fe II* emission is most strongly modulated by dust attenuation, and is additionally correlated with redshift, star formation rate, and [O II] equivalent width, such that systems at higher redshifts with lower dust levels, lower star formation rates, and larger [O II] equivalent widths show stronger Fe II* emission. We detect Mg II emission in at least 15% of the individual spectra and we find that objects showing stronger Mg II emission have higher specific star formation rates, smaller [O II] linewidths, larger [O II] equivalent widths, lower dust attenuations, and lower stellar masses than the sample as a whole. Mg II emission strength exhibits the strongest correlation with specific star formation rate, although we find evidence that dust attenuation and stellar mass also play roles in the regulation of Mg II emission. Future integral field unit observations of the spatial extent of Fe II* and Mg II emission in galaxies with high specific star formation rates, low dust attenuations, and low stellar masses will be important for probing the morphology of circumgalactic gas.

79 ASTRONOMY AND ASTROPHYSICS↗

ESTIMATING THE DEEP SOLAR MERIDIONAL CIRCULATION USING MAGNETIC OBSERVATIONS AND A DYNAMO MODEL: A VARIATIONAL APPROACH

We show how magnetic observations of the Sun can be used in conjunction with an axisymmetric flux-transport solar dynamo model in order to estimate the large-scale meridional circulation throughout the convection zone. Our innovative approach rests on variational data assimilation, whereby the distance between predictions and observations (measured by an objective function) is iteratively minimized by means of an optimization algorithm seeking the meridional flow that best accounts for the data. The minimization is performed using a quasi-Newton technique, which requires knowledge of the sensitivity of the objective function to the meridional flow. That sensitivity is efficiently computed via the integration of the adjoint flux-transport dynamo model. Closed-loop (also known as twin) experiments using synthetic data demonstrate the validity and accuracy of this technique for a variety of meridional flow configurations, ranging from unicellular and equatorially symmetric to multicellular and equatorially asymmetric. In this well-controlled synthetic context, we perform a systematic study of the behavior of our variational approach under different observational configurations by varying their spatial density, temporal density, and noise level, as well as the width of the assimilation window. We find that the method is remarkably robust, leading in most cases to a recovery of the true meridional flow to within better than 1%. These encouraging results are a first step toward using this technique to (i) better constrain the physical processes occurring inside the Sun and (ii) better predict solar activity on decadal timescales.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistics of internal stress fluctuations in dislocated crystals and relevance to density-based dislocation dynamics models

A statistical analysis of internal stress fluctuations, defined as the difference between the local mean stress and stress on dislocations, is presented for deforming crystals with 3D discrete dislocation systems. Dislocation realizations are generated using dislocation dynamics simulations and the associated stress field is computed as a superposition of a regularized stress field of dislocation lines within the domain of the solution and a complementary stress field computed via a finite-element boundary value problem. The internal stress fluctuations of interest are defined by an ensemble of the difference between the stress on dislocation lines and the local mean field stress in the crystal. The latter is established in a piecewise fashion over small voxels in the crystal thus allowing the difference between the local average stress and stress on segments to be easily estimated. The results show that the Schmid stress (resolved shear stress) and Escaig stress fluctuations on various slip systems sampled over a random set of points follow a Cauchy (Lorentz) distribution at all strain levels, with the amplitude and width of the distribution being dependent on the strain. Finally, the implications of the Schmid and Escaig internal stress fluctuations are discussed from the points of view of dislocation cross-slip and the dislocation motion in continuum dislocation dynamics.

36 MATERIALS SCIENCE↗

Direct estimation of the density of states for fermionic systems

Simulating time evolution is one of the most natural applications of quantum computers and is thus one of the most promising prospects for achieving practical quantum advantage. Here, we develop quantum algorithms to extract thermodynamic properties by estimating the density of states (DOS), which is a central object in quantum statistical mechanics. We introduce several key innovations that significantly improve the practicality and extend the generality of previous techniques. First, our approach allows one to estimate the DOS only for a specific subspace of the full Hilbert space. This is crucial for fermionic systems, since both canonical and grand canonical ensemble thermal equilibrium properties depend on subspaces of fixed number. Second, in our approach, by time evolving very simple, random initial states, such as randomly chosen computational basis states, we can exactly recover the DOS on average. Third, due to circuit-depth limitations, we only reconstruct the DOS up to a convolution with a Gaussian window—thus all imperfections that shift the energy levels by less than the width of the convolution window will not significantly affect the estimated DOS. For these reasons, we find the approach is a promising candidate for early quantum advantage as even short-time, noisy dynamics can yield a semiquantitative reconstruction of the DOS (convolution with a broad Gaussian window), while early fault-tolerant devices will likely enable higher-resolution DOS reconstruction through longer time evolutions. We demonstrate the practicality of our approach in representative Fermi-Hubbard and spin models and indeed find that our approach is highly robust against algorithmic errors in the time evolution and against gate noise. We further demonstrate that our approach is compatible with noisy intermediate-scale quantum (NISQ) computing NISQ-friendly variational techniques, introducing and leveraging a technique for variational time evolution.

97 MATHEMATICS AND COMPUTING↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

SU-E-T-359: Measurement of Various Metrics to Determine Changes in Megavoltage Photon Beam Energy

Purpose: To examine the relationship between photon beam energy and various metrics for energy on the flattened and flattening filter free (FFF) beams generated by the Varian TrueBeam. Methods: Energy changes were accomplished by adjusting the bending magnet current ±10% from the nominal value for the 4, 6, 8, and 10 MV flattened and 6 and 10 MV FFF beams. Profiles were measured for a 30×30 cm{sup 2} field using a 2D ionization chamber array and a 3D water Scanner which was also used to measure PDDs. For flattened beams we compared several energy metrics; PDD at 10 cm depth in water (PDD(10)); the variation over the central 80% of the field (Flat); and the average of the highest reading along each diagonal divided by the CAX value, diagonal normalized flatness (FDN). For FFF beams we examined PDD(10), FDN, and the width of a chosen isodose level in a 30×30 cm{sup 2} field (W(d%)). Results: Changes in PDD(10) were nearly linear with changes in energy for both flattened and FFF beams as were changes in FDN. Changes in W(d%) were also nearly linear with energy for the FFF beams. PDD(10) was not as sensitive to changes in energy compared to the other metrics for either flattened or FFF beams. Flat was not as sensitive to changes in energy compared to FDN for flattened beams and its behavior depends on depth. FDN was the metric that had the highest sensitivity to the changes in energy for flattened beams while W(d%) was the metric that had highest sensitivity to the changes in energy for FFF beams. Conclusions: The metric FDN was found to be most sensitive to energy changes for flattened beams, while the W(d%) was most sensitive to energy changes for FFF beams.

07 ISOTOPE AND RADIATION SOURCES↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Effects of intrinsic region width in Si/Li/ p-i-n diodes

Description of certain effects related to the width of the intrinsic region produced in a silicon p-i-n diode by lithium ion drifting. It is found that for wider intrinsic regions at large forward biases there is a larger ohmic drop across the region and a correspondingly smaller current. Moreover, the recovery time decreases with increasing intrinsic region width. Conversely, the decay phase time increases with increasing intrinsic region width and with increasing current levels.

Harman, T. L.↗

Directivity and spacing for the antenna elements

The optimum design choice for the MST radar antenna was considered. The following factors are required: directivity and gain; beam width and its symmetry; sidelobe levels, near and wide angle; impedance matching; feeder network losses; polarization diversity; steerability; cost effectiveness; and maintainability. The directivity and related beam forming aspects of various antenna elements and directivity aspects when such elements are formed into an array are discussed. Array performance for important variables, in particular, the spacing of the elements is considered.

Koshy, V. K.↗

Measurement of the characteristic X ray of oxygen and other ultrasoft X rays using mercuric iodide detectors

This letter reports the detection and resolution of the characteristic X-ray of oxygen at 523 eV and other ultrasoft X-rays (photons energy less than 1 keV) using radiation detectors fabricated from the compound semi-insulator mercuric iodide (HgI2). These detectors are capable of operation at room ambient but in these experiments were slightly cooled using a Peltier element to 0 C. A pulsed light feedback preamplifier with a Peltier element cooled (to -30 deg) first stage field-effect transistor was used to amplify signals from the detector. Overall system noise level was 185 eV (full width at half-maximum) limited by the temperature of the first stage field-effect transistor. With optimal cooling of this element the characteristic X-ray of carbon at 282 eV should be measurable. These results would seem to be important in measurement of biological samples in electron column instruments.

Iwanczyk, J. S.↗

Archival research on absorption lines in violently star-forming galaxies

A computerized analysis of a starburst model is discussed. The model proposes that the absorption line equivalent width should scale with the level of star forming activity. Archival International Ultraviolet Explorer (IUE) data on IUE spectra of luminous blue galaxies were compared with previous IUE observations of extragalactic HII regions and low luminosity galaxies. The comparisons are summarized and causes for offsets are discussed.

Gallagher, J. S.↗

Transverse Mode Dynamics of VCSELs Undergoing Current Modulation

Transverse mode dynamics of a 20-micron-diameter vertical-cavity surface-emitting laser (VCSEL) undergoing gain switching by deep current modulation is studied numerically. The direct current (dc) level is set slightly below threshold and is modulated by a large alternating current (ac). The resulting optical pulse train and transverse-mode patterns are obtained numerically. The ac frequency is varied from 2.5 GHz to 10 GHz, and the ac amplitude is varied from one-half to four times that of the dc level. At high modulation frequencies, a regular pulse train is not generated unless the ac amplitude is large enough. At all modulation frequencies, the transverse spatial profile switches from single-mode to multiple-mode pattern as the ac pumping level is increased. Optical pulse widths vary in the range 5-30 ps. with the pulse width decreasing when either the frequency is increased or the ac amplitude is decreased. The numerical modeling uses an approximation form of the semiconductor Maxwell-Bloch equations. Temporal evolution of the spatial profiles of the laser (and of carrier density) is determined without any assumptions about the type or number of modes. Keywords: VCSELs, current modulation, gain switching, transverse mode dynamics, computational modeling

Goorjian, Peter M.↗

On the Methods of Determining the Radio Emission Geometry in Pulsar Magnetospheres

We present a modification of the relativistic phase shift method of determining the radio emission geometry from pulsar magnetospheres proposed by Gangadhara & Gupta (2001). Our modification provides a method of determining radio emission altitudes which does not depend on the viewing geometry and does not require polarization measurements. We suggest application of the method to the outer edges of averaged radio pulse profiles to identify magnetic field lines associated with'the edges of the pulse and, thereby, to test the geometric method based on the measurement of the pulse width at the lowest intensity level. We show that another relativistic method proposed by Blaskiewicz et al. (1991) provides upper limits for emission altitudes associated with the outer edges of pulse profiles. A comparison of these limits with the altitudes determined with the geometric method may be used to probe the importance of rotational distortions of magnetic field and refraction effects in the pulsar magnetosphere. We provide a comprehensive discussion of the assumptions used in the relativistic methods.

Dyks, J.↗

UWB dual burst transmit driver

A dual burst transmitter for ultra-wideband (UWB) communication systems generates a pair of precisely spaced RF bursts from a single trigger event. An input trigger pulse produces two oscillator trigger pulses, an initial pulse and a delayed pulse, in a dual trigger generator. The two oscillator trigger pulses drive a gated RF burst (power output) oscillator. A bias driver circuit gates the RF output oscillator on and off and sets the RF burst packet width. The bias driver also level shifts the drive signal to the level that is required for the RF output device.

47 OTHER INSTRUMENTATION↗

Properties of the -513 km/s Ejecta in the Spectrum of Eta Carinae

In the spectral region 2400-3160A of Eta Carinae, we have identified approximately 500 absorption lines each with up to twenty velocity components. The -512 kilometers per second component is truly unique as 1) the typical line width is less than 3 kilometers per second, 2) the identified lines are in Fe I, Fe II, VII and Ti II, and 3) the lines originate from lower levels up to 2000 cm-1 above the ground level. We have measured the velocity centers, full width at half maximum and equivalent widths for approximately 100 absorption lines. Initial results were very confusing as we found bore variation in central velocities than would be expected from known STIS echelle wavelength standards. Upon further review, we found that the reported wavelengths in the NIST and Kurucz databases were not sufficiently accurate. S. Johansson searched FTS laboratory measurements performed at Lund for V II and Ti II and provided much improved wavelength measures. Likewise, we find more variation in column density than expected statistically from the accuracy of the equivalent widths for lines originating from the same energy level. We are reviewing the published gf values and our measurements to improve the measured column densities. Some spectroscopy of the ejecta has already been accomplished at two different epochs. Preliminary measures of equivalent widths indicate there may be some variation with time, but we await measurements planned for July 2003 during the upcoming spectroscopic minimum of Eta Carinae. The observations were accomplished through STScI and funding was from STIS GTO resources.

Danks, A.↗

Properties of the -513 km/s Ejecta in the Spectrum of Eta Carinae

In the spectral region 2400-3160A of Eta Carinae, we have identified approximately 500 absorption lines each with up to twenty velocity components. The -512 kilometers per second component is truely unique as 1) the typical line width is less than 3 kilometers per second, 2) the identified lines are in Fe I, Fe II, V II and Ti II, and 3) the lines originate from lower levels up to 2000 cm-1 above the ground level. We have measured the velocity centers, full width at half maximum and equivalent widths for approximately 100 absorption lines. Initial results were very confusing as we found more variation in central velocities than would be expected from known STIS echelle wavelength standards. Upon further review, we found that the reporteded wavelengths in the NIST and Kurucz databases were not sufficiently accurate. S. Johansson searched FTS laboratory measurements performed at Lund for V II and Ti II and provided much improved wavelength measures. Likewise, we find more variation in column density than expected statistically from the accuracy of the equivalent widths for lines originating from the same energy level. We are reviewing the published gf values and our measurements to improve the measured column densities. Some spectroscopy of the ejecta has already been accomplished at two different epochs. Preliminary measures of equivalent widths indicate there may be some variation with time, but we await measurements planned for July 2003 during the upcoming spectroscopic minimum of Eta Carinae. These observations were accomplished through STScI and funding was from STIS GTO resources.

Danks, Anthony↗