Machine Vision for High Precision Volume Measurement Applied to Levitated Containerless Materials Processing

By combining the best practices in optical dilatometry with new numerical methods, a high-speed and high precision technique has been developed to measure volume of levitated, containerlessly processed samples with sub- pixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermo-physical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermo-ophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the sub-pixel locations of sample edges and, in turn produce high precision measurements.

Bradshaw, R. C.↗

Terrestrial Microgravity Model and Threshold Gravity Simulation sing Magnetic Levitation

What is the threshold gravity (minimum gravity level) required for the nominal functioning of the human system? What dosage is required? Do human cell lines behave differently in microgravity in response to an external stimulus? The critical need for such a gravity simulator is emphasized by recent experiments on human epithelial cells and lymphocytes on the Space Shuttle clearly showing that cell growth and function are markedly different from those observed terrestrially. Those differences are also dramatic between cells grown in space and those in Rotating Wall Vessels (RWV), or NASA bioreactor often used to simulate microgravity, indicating that although morphological growth patterns (three dimensional growth) can be successiblly simulated using RWVs, cell function performance is not reproduced - a critical difference. If cell function is dramatically affected by gravity off-loading, then cell response to stimuli such as radiation, stress, etc. can be very different from terrestrial cell lines. Yet, we have no good gravity simulator for use in study of these phenomena. This represents a profound shortcoming for countermeasures research. We postulate that we can use magnetic levitation of cells and tissue, through the use of strong magnetic fields and field gradients, as a terrestrial microgravity model to study human cells. Specific objectives of the research are: 1. To develop a tried, tested and benchmarked terrestrial microgravity model for cell culture studies; 2. Gravity threshold determination; 3. Dosage (magnitude and duration) of g-level required for nominal functioning of cells; 4. Comparisons of magnetic levitation model to other models such as RWV, hind limb suspension, etc. and 5. Cellular response to reduced gravity levels of Moon and Mars.

Ramachandran, N.↗

Terrestrial Microgravity Model and Threshold Gravity Simulation using Magnetic Levitation

What is the threshold gravity (minimum gravity level) required for the nominal functioning of the human system? What dosage is required? Do human cell lines behave differently in microgravity in response to an external stimulus? The critical need for such a gravity simulator is emphasized by recent experiments on human epithelial cells and lymphocytes on the Space Shuttle clearly showing that cell growth and function are markedly different from those observed terrestrially. Those differences are also dramatic between cells grown in space and those in Rotating Wall Vessels (RWV), or NASA bioreactor often used to simulate microgravity, indicating that although morphological growth patterns (three dimensional growth) can be successfully simulated using RWVs, cell function performance is not reproduced - a critical difference. If cell function is dramatically affected by gravity off-loading, then cell response to stimuli such as radiation, stress, etc. can be very different from terrestrial cell lines. Yet, we have no good gravity simulator for use in study of these phenomena. This represents a profound shortcoming for countermeasures research. We postulate that we can use magnetic levitation of cells and tissue, through the use of strong magnetic fields and field gradients, as a terrestrial microgravity model to study human cells. Specific objectives of the research are: 1. To develop a tried, tested and benchmarked terrestrial microgravity model for cell culture studies; 2. Gravity threshold determination; 3. Dosage (magnitude and duration) of g-level required for nominal functioning of cells; 4. Comparisons of magnetic levitation model to other models such as RWV, hind limb suspension, etc. and 5. Cellular response to reduced gravity levels of Moon and Mars. The paper will discuss experiments md modeling work to date in support of this project.

Ramachandran, N.↗

Threshold Gravity Determination and Artificial Gravity Studies Using Magnetic Levitation

What is the threshold gravity (minimum gravity level) required for the nominal functioning of the human system? What dosage is required (magnitude and duration)? Do human cell lines behave differently in microgravity in response to an external stimulus? The critical need for a variable gravity simulator is emphasized by recent experiments on human epithelial cells and lymphocytes on the Space Shuttle clearly showing that cell growth and function are markedly different from those observed terrestrially. Those differences are also dramatic between cells grown in space and those in Rotating Wall Vessels (RWV), or NASA bioreactor often used to simulate microgravity, indicating that although morphological growth patterns (three dimensional growth) can be successfully simulated using RWVs, cell function performance is not reproduced - a critical difference. If cell function is dramatically affected by gravity off-loading, then cell response to stimuli such as radiation, stress, etc. can be very different from terrestrial cell lines. Yet, we have no good gravity simulator for use in study of these phenomena. This represents a profound shortcoming for countermeasures research. We postulate that we can use magnetic levitation of cells and tissue, through the use of strong magnetic fields and field gradients, as a terrestrial microgravity model to study human cells. Specific objectives of the research are: 1. To develop a tried, tested and benchmarked terrestrial microgravity model for cell culture studies; 2. Gravity threshold determination; 3. Dosage (magnitude and duration) of g-level required for nominal functioning of cells; 4. Comparisons of magnetic levitation model to other models such as RWV, hind limb suspension, etc. and 5. Cellular response to reduced gravity levels of Moon and Mars.

Ramachandran, N.↗

Development of a 32 Inch Diameter Levitated Ducted Fan Conceptual Design

The NASA John H. Glenn Research Center has developed a revolutionary 32 in. diameter Levitated Ducted Fan (LDF) conceptual design. The objective of this work is to develop a viable non-contact propulsion system utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels, and mitigate many of the concerns and limitations encountered in conventional aircraft propulsors. The physical layout consists of a ducted fan drum rotor with blades attached at the outer diameter and supported by a stress tuner ring at the inner diameter. The rotor is contained within a stator. This concept exploits the unique physical dimensions and large available surface area to optimize a custom, integrated, electromagnetic system that provides both the levitation and propulsion functions. The rotor is driven by modulated electromagnetic fields between the rotor and the stator. When set in motion, the time varying magnetic fields interact with passive coils in the stator assembly to produce repulsive forces between the stator and the rotor providing magnetic suspension. LDF can provide significant improvements in aviation efficiency, reliability, and safety, and has potential application in ultra-efficient motors, computers, and space power systems.

Eichenberg, Dennis J.↗

Levitated Duct Fan (LDF) Aircraft Auxiliary Generator

This generator concept includes a novel stator and rotor architecture made from composite material with blades attached to the outer rotating shell of a ducted fan drum rotor, a non-contact support system between the stator and rotor using magnetic fields to provide levitation, and an integrated electromagnetic generation system. The magnetic suspension between the rotor and the stator suspends and supports the rotor within the stator housing using permanent magnets attached to the outer circumference of the drum rotor and passive levitation coils in the stator shell. The magnets are arranged in a Halbach array configuration.

Eichenberg, Dennis J.↗

Submersion Quenching of Undercooled Liquid Metals in an Electrostatic Levitator

The NASA Marshall Space Flight Center (MSFC) electrostatic levitation (ESL) laboratory has a long history of providing materials research and thermophysical property data. The laboratory has recently added a new capability, a rapid quench system. This system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals and alloys. This is the first submersion quench system inside an electrostatic levitator. The system has been tested successfully with samples of zirconium, iron-cobalt alloys, titanium-zirconium-nickel alloys, and silicon-cobalt alloys. This rapid quench system will allow materials science studies of undercooled materials and new materials development, including studies of metastable phases and transient microstructures. In this presentation, the system is described and some initial results are presented.

SanSoucie, Michael P.↗

Magnetic Levitation for Long-Life Space Mechanisms: Technology Assessment and Remaining Challenges

Spacecraft mechanisms and mechanical systems must operate reliably and without failure to enable successful, long-term space missions. Such requirements place demands upon the tribological elements, especially bearings, which are frequently difficult or impossible to satisfy. Several recent, high-profile bearing failures in coolant fluid pumps and attitude control system (ACS) momentum wheels provided the impetus to assess the state-of-the-art non-contacting magnetic levitation-based, rotor support technologies.Magnetic levitation technology continues to gain acceptance for terrestrial applications and has been spaceflight demonstrated in mechanical systems such as reaction wheels (RWs) but is not in widespread use. The specific reasons inhibiting this new technology are not readily clear but include cost, weight, performance, and perceived risk. These reasons arise from a variety of real and perceived technical limitations in areas like materials, controls, sensors, thermal management and others. This white paper seeks to determine, define, and quantify the technical hurdles and gaps that must be overcome to enable the broad adoption of non-contacting bearings for long-life space mechanisms. It is anticipated that a better understanding of this complex topic may guide resource investments and clear the path to improved performance mechanical systems for spacecraft.

Samuel A Howard↗

Silicon Partitioning Between Iron-Rich Metal and Silicate Melt: New Constraints From Aerodynamic Laser Levitation Furnace Experiments

The partitioning of light elements (e.g., Si, C, H, etc.) between silicate melts and iron metal alloys as a function of pressure and temperature is a critical constraint in defining the compositional evolution of planetary interiors. While there are a significant number of experimental studies in the literature that examine the various influences of oxygen fugacity, temperature, pressure, and composition on the metal-melt partitioning of silicon, it is difficult to disentangle the effects of each variable due to the nominally independent parameters (e.g., pressure, temperature, composition) being collinear. To better test for the independent effects of pressure, temperature, and melt composition on the partitioning of silicon between iron alloy and silicate melt, new high temperature (1800°–2500°C), rapid quench (~700°C/s) aerodynamic levitation laser-heating experiments in the Fe-Si-Mg-O (En65-Fa5-Si3-Fe27) system were conducted. This high temperature, low pressure method is ideal for these experiments because it eliminates the metal container as a sink for elements of interest to partition into, and it has a rapid quench rate that minimizes potential exsolution of silicon from the metal phase during quench cooling. Given the short run times of the levitation experiments (30–60 seconds), a time series at a lower temperature (1700°C) in a vertical gas-mixing muffle tube furnace was also conducted to assess equilibrium times of the bulk composition. All successful runs were imaged using back-scatter electron imaging and analyzed for phase composition using a JEOL 8530F field emission microprobe. These new data were added to a comprehensive and internally consistent data set created from published experiments, and subsequently modeled using parameters designed to minimize collinearity (e.g., optical basicity is used as a proxy for melt composition). High collinearity is found in the data set however between temperature and oxygen fugacity, precluding any model that contains both as nominally independent variables. The resulting model demonstrates a statistically significant effect of pressure, temperature, and melt composition on the partitioning of silicon in Fe-rich metal, which has implications for the formation of planetary cores in rocky planets and provides important constraints on potential bulk core compositions.

Metal↗

Measuring the Density, Viscosity, and Surface Tension of Molten Titanates Using Electrostatic Levitation in Microgravity

Rare earth and barium titanates are useful as ferroelectric, dielectric, and optical materials. Measurements of their thermophysical properties in the liquid state can help guide melt processing technologies for their manufacture and advance understanding of fragile liquids' behavior and glass formation. Here, we report the density, thermal expansion, viscosity, and surface tension of molten BaTiNsub>2 O 5 , BaTi 4 O 9 , and 83TiO 2 -17RE 2 O 3 (RE = La or Nd). Measurements were made using electrostatic levitation and droplet oscillation techniques in microgravity, which provide access to quiescent liquid droplets and deep supercooling of 510–815 K below the equilibrium melting points. Densities were measured over 900–2400 K. Viscosities were similar for all four compositions, increasing from ∼10 mPa s near 2100 K to ∼30 mPa s near 1750 K. Surface tensions were 450–490 dyn cm −1 for the rare earth titanates and 383–395 dyn cm−1 for the barium titanates; surface tensions of all compositions had small or negligible temperature dependence over 1700–2200 K. For solids recovered after melt quenching, x-ray microtomography revealed the fracture mechanics in crystalline products and minimal internal porosity in glass products, likely arising from entrapped gas bubbles. Internal microstructures were generally similar for products processed either in microgravity or in a terrestrial aerodynamic levitator.

Stephen K Wilke↗

Passive levitation in alternating magnetic fields

Stable levitation of an object in an alternating magnetic field can be achieved by eliminating coupling between the rotational and translational forces acting on the object. Stable levitation can also be achieved by varying the coupling between the rotational and translational forces acting on the object, while maintaining one or more of the rotational and translational forces steady in time.

Romero, Louis↗

Magnetic levitation

A magnetic levitation system is described, including a first cylinder-shaped magnet; a second cylinder-shaped magnet coaxially aligned with the first cylinder-shaped magnet; and a first cavity coaxially aligned with the first cylinder-shaped magnet; wherein the surfaces of the like-poles of the first and second cylinder-shaped magnets are parallel to each other and face each other to result in a linear magnetic field between the first and the second magnets. Methods of using a magnetic levitation system for analyzing a diamagnetic or paramagnetic sample are also described.

Ge, Shencheng↗

The effect of dust charge variation, due to ion flow and electron depletion, on dust levitation

Using a fluid model, the plasma densities, electron temperature and ion Mach number in front of a powered electrode in different plasma discharges is computed. The dust charge is computed using OML theory for Maxwellian electrons and ions distributed according to a shifted-Maxwellian. By assuming force balance between gravity and the electrostatic force, the dust levitation height is obtained. The importance of the dust charge variation is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vertical vibration and shape oscillation of acoustically levitated water drops

We present the vertical harmonic vibration of levitated water drops within ultrasound field. The restoring force to maintain such a vibration mode is provided by the resultant force of acoustic radiation force and drop gravity. Experiments reveal that the vibration frequency increases with the aspect ratio for drops with the same volume, which agrees with the theoretical prediction for those cases of nearly equiaxed drops. During the vertical vibration, the floating drops undergo the second order shape oscillation. The shape oscillation frequency is determined to be twice the vibration frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The near-field acoustic levitation of high-mass rotors

Here we demonstrate that spherical rotors with 40 mm diameter and 0-1 kg mass can be suspended more than tens of micrometers away from an ultrasonically vibrating concave surface by near-field acoustic radiation force. Their rotating speeds exceed 3000 rpm. An acoustic model has been developed to evaluate the near-field acoustic radiation force and the resonant frequencies of levitation system. This technique has potential application in developing acoustic gyroscope.

42 ENGINEERING↗