Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADING RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On the measurement of the crack tip stress field as a means of determining Delta K(sub eff) under conditions of fatigue crack closure

The optical method of caustics has been successfully extended to enable stress intensity factors as low as 1MPa square root of m to be determined accurately for central fatigue cracks in 2024-T3 aluminium alloy test panels. The feasibility of using this technique to study crack closure, and to determine the effective stress intensity factor range, Delta K(sub eff), has been investigated. Comparisons have been made between the measured values of stress intensity factor, K(sub caus), and corresponding theoretical values, K(sub theo), for a range of fatigue cracks grown under different loading conditions. The values of K(sub caus) and K(sub theo) were in good agreement at maximum stress, where the cracks are fully open, while K(sub caus) exceeded K(sub theo) at minimum stress, due to crack closure. However, the levels of crack closure and values of Delta K(sub eff) obtained could not account for the variations of crack growth rate with loading conditions. It is concluded that the values of Delta K(sub eff), based on caustic measurements in a 1/square root of r stress field well outside the plastic zone, do not fully reflect local conditions which control crack tip behavior.

Wallhead, Ian R.↗

Observations of fatigue crack growth rate and closure behavior in 7475-T731 aluminum under variable amplitude loading

Simultaneous measures of fatigue crack propagation rate and crack closure were taken from 7475-T731 aluminum alloy center cracked tensile specimens under variable amplitude loading conditions. Results indicate the presence of load interaction in a variety of repeated variable amplitude loading blocks. Load interaction results in retardation of the propagation rate for most loading blocks examined in the study. Closure did not explain observed delay behavior associated with high stress ratio and single peak overloads. Primary influences on the crack opening stress intensity level include the maximum stress intensity of the repeated loading block, the minimum stress intensity of the block, and the number of fatigue cycles between overloads of the block.

Turner, Charles C.↗

Response and adaptation of Beagle dogs to hypergravity

Eight male Beagle dogs, five months old, were centrifuged continuously for three months at progressively increasing loads. Heart rate and deep body temperature were monitored continuously by implant biotelemetry. Initially, centrifuged dogs showed transient decreases in heart rate and body temperature along with changes in their diurnal rhythm patterns. Compared with normal gravity controls, exposed dogs showed a slower growth rate and a reduced amount of body fat. Blood protein, total lipids, cholesterol, calcium, packed cell volume, red blood cell count, and hemoglobin were also decreased significantly. Absolute weights of the leg bones of centrifuged dogs were significantly greater than controls. Photon absorptiometry revealed significant density increases in selective regions of the femur and humerus of centrifuged dogs. In spite of the various changes noted, results from this and other studies affirm the view that dogs can tolerate and adapt to sustained loads as high as 2.5 g without serious impairment of their body structure and function.

Oyama, J.↗

Study of dynamic emission spectra from lubricant films in an elastohydrodynamic contact using Fourier transform spectroscopy

Infrared emission spectra were obtained through a diamond window from lubricating fluids in an operating sliding elastohydrodynamic contact and analyzed by comparison with static absorption spectra under similar pressures. Different loads, shear rates and temperatures were used. Most of the spectra exhibited polarization characteristics, indicating directional alignment of the lubricant in the EHD contact. Among the fluids studied were a "traction" fluid, an advanced ester, and their mixtures, a synthetic paraffin, a naphthenic reference fluid (N-1), both neat and containing 1 percent of p-tricresyl phosphate as an anti-wear additive, and a C-ether. Traction properties were found to be nearly proportional to mixture composition for traction fluid and ester mixtures. The anti-wear additive reduced traction and fluid temperature under low loads but increased them under higher loads, giving rise to formation of a friction polymer.

Lauer, J. L.↗

Incorporation of Mean Stress Effects into the Micromechanical Analysis of the High Strain Rate Response of Polymer Matrix Composites

The results presented here are part of an ongoing research program, to develop strain rate dependent deformation and failure models for the analysis of polymer matrix composites subject to high strain rate impact loads. A micromechanics approach is employed in this work, in which state variable constitutive equations originally developed for metals have been modified to model the deformation of the polymer matrix, and a strength of materials based micromechanics method is used to predict the effective response of the composite. In the analysis of the inelastic deformation of the polymer matrix, the definitions of the effective stress and effective inelastic strain have been modified in order to account for the effect of hydrostatic stresses, which are significant in polymers. Two representative polymers, a toughened epoxy and a brittle epoxy, are characterized through the use of data from tensile and shear tests across a variety of strain rates. Results computed by using the developed constitutive equations correlate well with data generated via experiments. The procedure used to incorporate the constitutive equations within a micromechanics method is presented, and sample calculations of the deformation response of a composite for various fiber orientations and strain rates are discussed.

Goldberg, Robert K.↗

Physiologically constrained aerocapture for manned Mars missions

Aerobraking has been proposed as a critical technology for manned missions to Mars. The variety of mission architectures currently under consideration presents aerobrake designers with an enormous range of potential entry scenarios. Two of the most important considerations in the design of an aerobrake are the required control authority (lift-to-drag ratio) and the aerothermal environment which the vehicle will encounter. Therefore, this study examined the entry corridor width and stagnation-point heating rate and load for the entire range of probable entry velocities, lift-to-drag ratios, and ballistic coefficients for capture at both Earth and Mars. To accomplish this, a peak deceleration limit for the aerocapture maneuvers had to be established. Previous studies had used a variety of load limits without adequate proof of their validity. Existing physiological and space flight data were examined, and it was concluded that a deceleration limit of 5 G was appropriate. When this load limit was applied, numerical studies showed that an aerobrake with an L/D of 0.3 could provide an entry corridor width of at least 1 degree for all Mars aerocaptures considered with entry velocities up to 9 km/s. If 10 km/s entries are required, an L/D of 0.4 to 0.5 would be necessary to maintain a corridor width of at least 1 degree. For Earth return aerocapture, a vehicle with an L/D of 0.4 to 0.5 was found to provide a corridor width of 0.7 degree or more for all entry velocities up to 14.5 km/s. Aerodynamic convective heating calculations were performed assuming a fully catalytic, 'cold' wall; radiative heating was calculated assuming that the shock layer was in thermochemical equilibrium. Heating rates were low enough for selected entries at Mars that a radiatively cooled thermal protection system might be feasible, although an ablative material would be required for most scenarios. Earth return heating rates were generally more severe than those encountered by the Apollo vehicles, and would require ablative heat shields in all cases.

Lyne, James Evans↗

Diffusion freezeout in gas-loaded heat pipes.

Experimental diffusion freezeout rates in a gas loaded heat pipe are presented and compared with predictions of an analysis and computer program published earlier. The experimental approach was to pivot a heat pipe on knife edges and use an analytical mass balance to measure the rate of mass migration within the pipe. Diffusion freezeout rates in a water heat pipe were measured as a function of the condenser sink temperature and the condenser-to-sink thermal conductance. Measured rates varied between 19 and 270 mg/hr and yielded 64 to 99 percent agreement with predicted values. These results indicated that the analysis and computer program for predicting the behavior of gas loaded heat pipes are useful tools for designing such systems.

Marcus, B. D.↗

Dynamic buckling estimates

Dynamic buckling estimates for sensitive structures subjected to finite-time loading

COMPRESSION BUCKLING↗

Nongassing nickel-cadmium battery electrodes and cells

The failure of nickel-cadmium storage batteries due to severe gassing during charging is discussed. In order to increase the life of such cells, nongassing positive and negative electrodes are used. The gassing characteristics of nickel electrodes were evaluated as a function of their loading, charge rate, and charge temperature.

Luksha, E.↗

Origin of moisture effects on crack propagation in composites

A study has been made of the origin of unexpected moisture effects on crack extension in fiberglass laminates. Water immersion has been found to greatly reduce the rate of crack growth under constant loading, while increasing the rate under cyclic loading, the latter effect being the expected one. Observations were made of the extension of the stable damage zone at the tip of precut notches in wet and dry environments. The damage zone size is postulated as a critical element in the relaxation of high stress concentrations in composites, such as those at notch or crack tips. Under constant load, moisture is shown to greatly expand the interply delamination region in the damage zone, thus reducing the local fiber stresses and increasing crack resistance. Under cyclic loading moisture has little effect on the delamination region, which is large even for dry environments, and the only effect is weakening of the material and acceleration of cracks. Severe hygrothermal conditions can so weaken the material that the crack resistance is reduced under constant loading as well.

Mandell, J. F.↗

Supersonic market and economic analyses

Advanced supersonic transport markets of the free world were projected for the period 1985 to 2004. Passenger traffic volume and airplane range and seat capacity requirements were estimated for Mach 2.2 service by international regional area market areas and by city pairs within and between these areas. Market factors and traffic factors examined include variable loads, growth rates, supersonic transport market shares, and schedule frequencies considering the different makeup of passenger traffic and individual city pairs. Direct, indirect, and total operating costs and yield levels were economically analyzed for first class and full fare economy class traffic.

Rochte, L. S.↗

Integration and software for thermal test of heat rate sensors

A minicomputer controlled radiant test facility is described which was developed and calibrated in an effort to verify analytical thermal models of instrumentation islands installed aboard the space shuttle external tank to measure thermal flight parameters during ascent. Software was provided for the facility as well as for development tests on the SRB actuator tail stock. Additional testing was conducted with the test facility to determine the temperature and heat flux rate and loads required to effect a change of color in the ET tank external paint. This requirement resulted from the review of photographs taken of the ET at separation from the orbiter which showed that 75% of the external tank paint coating had not changed color from its original white color. The paint on the remaining 25% of the tank was either brown or black, indicating that it had degraded due to heating or that the spray on form insulation had receded in these areas. The operational capability of the facility as well as the various tests which were conducted and their results are discussed.

Wojciechowski, C. J.↗

Comparison of simulator fidelity model predictions with in-simulator evaluation data

A full factorial in simulator experiment of a single axis, multiloop, compensatory pitch tracking task is described. The experiment was conducted to provide data to validate extensions to an analytic, closed loop model of a real time digital simulation facility. The results of the experiment encompassing various simulation fidelity factors, such as visual delay, digital integration algorithms, computer iteration rates, control loading bandwidths and proprioceptive cues, and g-seat kinesthetic cues, are compared with predictions obtained from the analytic model incorporating an optimal control model of the human pilot. The in-simulator results demonstrate more sensitivity to the g-seat and to the control loader conditions than were predicted by the model. However, the model predictions are generally upheld, although the predicted magnitudes of the states and of the error terms are sometimes off considerably. Of particular concern is the large sensitivity difference for one control loader condition, as well as the model/in-simulator mismatch in the magnitude of the plant states when the other states match.

Parrish, R. V.↗

Solar/Thermal Powerplant Simulation

Simulation program evaluates performances and energy costs of diverse solar/thermal powerplant configurations. Approach based on optimizing sizes of collector and storage subsystems to give minimum energy cost for specified plant rating and load factor. Methodology provides for consistent comparative evaluation of solar/thermal powerplants.

Bowyer, J. M.↗