Search NASA⌕ Search

SEARCH · Search NASA

Results for “Level Set Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Left ventricular endocardial surface detection based on real-time 3D echocardiographic data

OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.

Non-NASA Center↗

Bayesian Static Parameter Estimation for Partially Observed Diffusions via Multilevel Monte Carlo

In this article we consider static Bayesian parameter estimation for partially observed diffusions that are discretely observed. We work under the assumption that one must resort to discretizing the underlying diffusion process, for instance, using the Euler--Maruyama method. Given this assumption, we show how one can use Markov chain Monte Carlo (MCMC) and particularly particle MCMC [C. Andrieu, A. Doucet, and R. Holenstein, J. R. Stat. Soc. Ser. B Stat. Methodol., 72 (2010), 269--342] to implement a new approximation of the multilevel (ML) Monte Carlo (MC) collapsing sum identity. Our approach comprises constructing an approximate coupling of the posterior density of the joint distribution over parameter and hidden variables at two different discretization levels and then correcting by an importance sampling method. The variance of the weights are independent of the length of the observed data set. The utility of such a method is that, for a prescribed level of mean square error, the cost of this MLMC method is provably less than i.i.d. sampling from the posterior associated to the most precise discretization. However the method here comprises using only known and efficient simulation methodologies. Finally, the theoretical results are illustrated by inference of the parameters of two prototypical processes given noisy partial observations of the process: the first is an Ornstein--Uhlenbeck process and the second is a more general Langevin equation.

97 MATHEMATICS AND COMPUTING↗

Lessons and Recommendations for Board-Level Testing with Protons

Protons with sufficiently high energy, provided in a broad field covering on the order of 0.1m2 can be used to perform board-level testing for single event effects (SEE). NASA has used this approach for board-level testing over the last 20 years. Although many difficulties inherent in SEE testing are simplified when using a board-level test, including reduced cost, the method is inherently risky because of the limited value of the collected data and the potential to make critical mistakes when performing SEE testing this way, leading to data of less value. Historically, NASA’s approach to proton board-level testing has been limited to lower criticality applications. However, with users both inside and outside NASA using this method for higher levels of mission assurance, we have put together a set of lessons and recommendations to improve the value of data collected using this method. Focus areas covered include test preparation, test execution, and interpretation of results.

Guertin, Steven M.↗

Relativistic MR-MP Energy Levels for L-shell Ions of Sulfur and Argon

Calculated level energies for valence and K-vacancy states are given for the ion series S vii–S xiv and Ar ix–Ar xvi. The calculations were performed with the relativistic Multi-Reference Møller–Plesset Perturbation Theory method (MR-MP). The data set includes all the level energies with configurations $1{s}^{2}2{(s,p)}^{q}$, $1{s}^{2}2{(s,p)}^{q-1}{nl}$, $1{s}^{1}2{(s,p)}^{q+1}$, $1{s}^{1}2{(s,p)}^{q}{nl}$, $2{(s,p)}^{q+2}$, and $2{(s,p)}^{q+1}{nl}$, where 1 ≤ q ≤ 8, n ≤ 5, and l ≤ 3. We have compared our results with data from the National Institute of Standards and Technology (NIST) online database and with previous calculations. The average deviation of valence level energies ranges from 0.16 eV in Ne-like ions to 0.01 eV in Li-like ions, demonstrating that the present MR-MP valence level energies are highly accurate. In the case of K-vacancy states, the deviation is generally below 0.3 eV for Li-like S xiv and Ar xvi. The deviation for K-vacancy energies in other L-shell ions (Be-, B-, C-, N-, and O-like Ar ions) is higher but likely because the NIST-recommended values have a higher uncertainty. The data set includes many n = 4 and n = 5 valence and K-vacancy levels in L-shell ions of S and Ar that have not been previously reported. The data can be used for line identification and modeling of L-shell ions of S and Ar in astrophysical and laboratory-generated plasmas, and as energy references in the absence of more accurate laboratory calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

Anharmonic Bloch oscillations of electrons in electrically biased superlattices

The phenomenon of anharmonic Bloch oscillations (i.e., oscillations with a frequency which is a multiple of the Bloch frequency) is considered. The energy-band structure of silicon-carbide polytypes where these oscillations are observed is calculated ab initio. A one-dimensional model potential making it possible to calculate the Stark wave functions in a biased superlattice is constructed for these polytypes. The transfer matrix method is used to find the set of energy levels (the so-called Stark ladder) and calculate the electron wave functions. It is shown that both radiative transitions between neighboring Stark levels (at the Bloch frequency) and transitions in the form of jumps via several levels, accompanied by emission at frequencies that are multiples of the Bloch frequency, may occur. The calculated probabilities of transitions between Stark-ladder levels increase with increasing applied field strength.

36 MATERIALS SCIENCE↗

Judgments of eye level in light and in darkness

Subjects judged eye level in the light and in the dark by raising and lowering themselves in a dental chair until a stationary target appeared to be at the level of their eyes. This method reduced the possibility of subjects' using visible landmarks as reference points for setting eye level during lighted trials, which may have contributed to artificially low estimates of the variability of this judgment in previous studies. Chair settings were 2.5 deg higher in the dark than in the light, and variability was approximately 66 percent greater in the dark than in the light. These results are discussed in terms of possible interactions of two separate systems, one sensitive to the orientations of visible surfaces and the other sensitive to bodily and gravitational information.

Stoper, Arnold E.↗

SU-F-207-16: CT Protocols Optimization Using Model Observer

Purpose: To quantitatively evaluate the performance of different CT protocols using task-based measures of image quality. This work studies the task of size and the contrast estimation of different iodine concentration rods inserted in head- and body-sized phantoms using different imaging protocols. These protocols are designed to have the same dose level (CTDIvol) but using different X-ray tube voltage settings (kVp). Methods: Different concentrations of iodine objects inserted in a head size phantom and a body size phantom are imaged on a 64-slice commercial CT scanner. Scanning protocols with various tube voltages (80, 100, and 120 kVp) and current settings are selected, which output the same absorbed dose level (CTDIvol). Because the phantom design (size of the iodine objects, the air gap between the inserted objects and the phantom) is not ideal for a model observer study, the acquired CT images are used to generate simulation images with four different sizes and five different contracts iodine objects. For each type of the objects, 500 images (100 x 100 pixels) are generated for the observer study. The observer selected in this study is the channelized scanning linear observer which could be applied to estimate the size and the contrast. The figure of merit used is the correct estimation ratio. The mean and the variance are estimated by the shuffle method. Results: The results indicate that the protocols with 100 kVp tube voltage setting provides the best performance for iodine insert size and contrast estimation for both head and body phantom cases. Conclusion: This work presents a practical and robust quantitative approach using channelized scanning linear observer to study contrast and size estimation performance from different CT protocols. Different protocols at same CTDIvol setting could Result in different image quality performance. The relationship between the absorbed dose and the diagnostic image quality is not linear.

60 APPLIED LIFE SCIENCES↗

First model-independent Dalitz analysis of B 0 → DK* 0 , D→K$^{0}_{S}$π + π – decay

We report a measurement of the amplitude ratio r S of B 0 → D 0 K* 0 and B 0 → D 0 ¯K* 0 decays with a Dalitz analysis of D → K$^{0}_{S}$π + π – decays, for the first time using a model-independent method. We set an upper limit rS<0.87 at the 68\% confidence level, using the full data sample of 772×10 6 BB¯ pairs collected at the Υ(4S) resonance with the Belle detector at the KEKB e + e – collider. This result is obtained from observables x–= +0.4$^{+1.0+0.0}_{–0.6–0.1}$ ± 0.0, y– = –0.6$^{+0.8+0.1}_{–1.0–0.0}$ ± 0.1, x + = +0.1$^{+0.7+0.0}_{–0.4–0.1}$ ± 0.1 and y + = +0.3$^{+0.5+0.0}_{–0.8–0.1}$ ± 0.1, where x ± = r S cos(δ S ± Φ 3 ), y ± = r S sin(δ S ± Φ 3 ) and Φ 3 (δ S ) is the weak (strong) phase difference between B 0 → D 0 K* 0 and B 0 → D¯ 0 K* 0 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generalized conditional symmetries and related solutions of the Grad-Shafranov equation

The generalized conditional symmetry (GCS) method is applied to a specific case of the Grad–Shafranov (GS) equation, in cylindrical geometry assuming the existence of an axial symmetry. We investigate the conditions that yield the GS equation admitting a special class of second-order GCSs. The determining system for the unknown arbitrary functions is solved in several special cases and new exact solutions, including solitary waves, different in form and structure from the ones obtained using other nonclassical symmetry methods, are pointed out. Several plots of the level sets or flux surfaces of the new solutions as well as surfaces with vanishing flow are displayed. The obtained solutions can be useful for studying plasma equilibrium, transport phenomena, and magnetohydrodynamic stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiclass Classification Using Bayesian Multivariate Adaptive Regression Splines

We present a new Bayesian model for the problem of multiclass classification. In this model, the probabilities of class membership of a given observation are determined by the mean of a latent Gaussian distribution. The mean functions of this latent distribution consist of combinations of highly flexible basis functions of the inputs: multivariate adaptive regression splines (MARS), first developed for multiple regression. We use reversible jump Markov chain Monte Carlo to make inference on the classification model, including the number of basis functions. We compare the probabilistic classification performance of our proposed approach to existing methods on simulated and benchmark data, and compare uncertainty estimates on simulated data. Our proposed method compares favorably with existing Bayesian and frequentist multiclass classification methods in out-of-sample probabilistic classification, and uncertainty estimation of these probabilistic classifications. We examine the fit of the proposed method to a data set of hurricane storm surge levels near Delaware Bay, US, and conclude that sea level rise is a key contributor to damage delivered by storm surge.

97 MATHEMATICS AND COMPUTING↗

The Valuation of Scientific and Technical Experiments

Rational selection of scientific and technical experiments for space missions is studied. Particular emphasis is placed on the assessment of value or worth of an experiment. A specification procedure is outlined and discussed for the case of one decision maker. Experiments are viewed as multi-attributed entities, and a relevant set of attributes is proposed. Alternative methods of describing levels of the attributes are proposed and discussed. The reasonableness of certain simplifying assumptions such as preferential and utility independence is explored, and it is tentatively concluded that preferential independence applies and utility independence appears to be appropriate.

Williams, F. E.↗

Generic and robust method for automatic segmentation of PET images using an active contour model

Purpose: Although positron emission tomography (PET) images have shown potential to improve the accuracy of targeting in radiation therapy planning and assessment of response to treatment, the boundaries of tumors are not easily distinguishable from surrounding normal tissue owing to the low spatial resolution and inherent noisy characteristics of PET images. The objective of this study is to develop a generic and robust method for automatic delineation of tumor volumes using an active contour model and to evaluate its performance using phantom and clinical studies. Methods: MASAC, a method for automatic segmentation using an active contour model, incorporates the histogram fuzzy C-means clustering, and localized and textural information to constrain the active contour to detect boundaries in an accurate and robust manner. Moreover, the lattice Boltzmann method is used as an alternative approach for solving the level set equation to make it faster and suitable for parallel programming. Twenty simulated phantom studies and 16 clinical studies, including six cases of pharyngolaryngeal squamous cell carcinoma and ten cases of nonsmall cell lung cancer, were included to evaluate its performance. Besides, the proposed method was also compared with the contourlet-based active contour algorithm (CAC) and Schaefer’s thresholding method (ST). The relative volume error (RE), Dice similarity coefficient (DSC), and classification error (CE) metrics were used to analyze the results quantitatively. Results: For the simulated phantom studies (PSs), MASAC and CAC provide similar segmentations of the different lesions, while ST fails to achieve reliable results. For the clinical datasets (2 cases with connected high-uptake regions excluded) (CSs), CAC provides for the lowest mean RE (−8.38% ± 27.49%), while MASAC achieves the best mean DSC (0.71 ± 0.09) and mean CE (53.92% ± 12.65%), respectively. MASAC could reliably quantify different types of lesions assessed in this work with good accuracy, resulting in a mean RE of −13.35% ± 11.87% and −11.15% ± 23.66%, a mean DSC of 0.89 ± 0.05 and 0.71 ± 0.09, and a mean CE of 19.19% ± 7.89% and 53.92% ± 12.65%, for PSs and CSs, respectively. Conclusions: The authors’ results demonstrate that the developed novel PET segmentation algorithm is applicable to various types of lesions in the authors’ study and is capable of producing accurate and consistent target volume delineations, potentially resulting in reduced intraobserver and interobserver variabilities observed when using manual delineation and improved accuracy in treatment planning and outcome evaluation.

60 APPLIED LIFE SCIENCES↗

Accelerated Stress-Corrosion Testing

Test procedures for accelerated stress-corrosion testing of high-strength aluminum alloys faster and provide more quantitative information than traditional pass/fail tests. Method uses data from tests on specimen sets exposed to corrosive environment at several levels of applied static tensile stress for selected exposure times then subsequently tensile tested to failure. Method potentially applicable to other degrading phenomena (such as fatigue, corrosion fatigue, fretting, wear, and creep) that promote development and growth of cracklike flaws within material.

Source record↗

Effective Radius of Ice Cloud Particle Populations Derived from Aircraft Probes

The effective radius(r(sub e)) is a crucial variable in representing the radiative properties of cloud layers in general circulation models. This parameter is proportional to the condensed water content (CWC) divided by the extinction (sigma). For ice cloud layers, parameterizations for r(sub e), have been developed from aircraft in-situ measurements 1) indirectly, using data obtained from particle spectrometer probes and assumptions or observations about particle shape and mass to get the ice water content (IWC) and area to get sigma, and recently 2) from probes that measure IWC and sigma directly. This study compares [IWC/sigma] derived from the two methods using data sets acquired from comparable instruments on two aircraft, one sampling clouds at mid-levels and the other at upper-levels during the CRYSTAL-FACE field program in Florida in 2002. The sigma and IWC derived by each method are compared and evaluated in different ways for each aircraft data set. Direct measurements of sigma exceed those derived indirectly by a factor of two to two and a half. The IWC probes, relying on ice sublimation, appear to measure accurately except when the IWC is high or the particles too large to sublimate completely during the short transit time through the probe. The IWC estimated from the particle probes are accurate when direct measurements are available to provide constraints and useful information in high IWC/large particle situations. Because of the discrepancy in sigma estimates between the direct and indirect approaches, there is a factor of 2 to 3 difference in [IWC/sigma] between them. Although there are significant uncertainties involved in its use, comparisons with several independent data sources suggest that the indirect method is the more accurate of the two approaches. However, experiments are needed to resolve the source of the discrepancy in sigma.

Heymsfield, Andrew J.↗

Digital zero noise extrapolation for quantum error mitigation

Zero-noise extrapolation (ZNE) is an increasingly popular technique for mitigating errors in noisy quantum computations without using additional quantum resources. We review the fundamentals of ZNE and propose several improvements to noise scaling and extrapolation, the two key components in the technique. We introduce unitary folding and parameterized noise scaling. Furthermore, these are digital noise scaling frameworks, i.e. one can apply them using only gate-level access common to most quantum instruction sets. We also study different extrapolation methods, including a new adaptive protocol that uses a statistical inference framework. Benchmarks of our techniques show error reductions of 18X to 24X over non-mitigated circuits and demonstrate ZNE effectiveness at larger qubit numbers than have been tested previously. In addition to presenting new results, this work is a self-contained introduction to the practical use of ZNE by quantum programmers.

quantum computing↗

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aerial Scene Recognition using Efficient Sparse Representation

Advanced scene recognition systems for processing large volumes of high-resolution aerial image data are in great demand today. However, automated scene recognition remains a challenging problem. Efficient encoding and representation of spatial and structural patterns in the imagery are key in developing automated scene recognition algorithms. We describe an image representation approach that uses simple and computationally efficient sparse code computation to generate accurate features capable of producing excellent classification performance using linear SVM kernels. Our method exploits unlabeled low-level image feature measurements to learn a set of basis vectors. We project the low-level features onto the basis vectors and use simple soft threshold activation function to derive the sparse features. The proposed technique generates sparse features at a significantly lower computational cost than other methods~\cite{Yang10, newsam11}, yet it produces comparable or better classification accuracy. We apply our technique to high-resolution aerial image datasets to quantify the aerial scene classification performance. We demonstrate that the dense feature extraction and representation methods are highly effective for automatic large-facility detection on wide area high-resolution aerial imagery.

Computer Vision↗

Extending quantum probabilistic error cancellation by noise scaling

Here, we propose a general framework for quantum error mitigation that combines and generalizes two techniques: probabilistic error cancellation (PEC) and zero-noise extrapolation (ZNE). Similar to PEC, the proposed method represents ideal operations as linear combinations of noisy operations that are implementable on hardware. However, instead of assuming a fixed level of hardware noise, we extend the set of implementable operations by noise scaling. By construction, this method encompasses both PEC and ZNE as particular cases and allows us to investigate a larger set of hybrid techniques. For example, gate extrapolation can be used to implement PEC without requiring knowledge of the device’s noise model, e.g., avoiding gate-set tomography. Alternatively, probabilistic error reduction can be used to estimate expectation values at intermediate virtual noise strengths (below the hardware level), leading to partially mitigated results at a lower sampling cost. Moreover, multiple results obtained with different noise-reduction factors can be further postprocessed with ZNE to better approximate the zero-noise limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗