Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Recent advances of polarized {sup 3}He target at Jefferson Lab

Polarized {sup 3}He targets have been widely used in nuclear and particle physics experiments to study neutron structure in the spin degree of freedom, as most of the {sup 3}He spin is carried by the unpaired neutron. The Spin-Exchange Optical Pumping (SEOP) process is used in Jefferson Lab Hall A to polarize its {sup 3}He target. In recent years, both the performance and corresponding polarimetry of such a target have been greatly improved. Several experiments recently carried out in Hall A have achieved record high figure of merit using this target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TESLA's High Gradient March: Thirty years anniversary of TESLA Technology Collaboration (TTC)

In 2020, the TTC (TESLA Technology Collaboration) celebrates 30 years of collaborative efforts on SRF technologies. The first international TESLA workshop on a TeV Energy Superconducting Linear Accelerator was held at Cornell University on July 23-26, 1990. The purpose of the meeting was to work on a parameter list for a superconducting high energy physics collider in the Teravolt energy region and to explore ideas on how to increase the gradients and lower the costs for the accelerator structures. It was clear from the beginning that the needed technological progress would require a large international collaboration. This meeting was indeed the origin of a long preparation effort toward a future ILC (International Linear Collider), which eventually led to the realization of the TTF (TESLA Test Facility, since 2005 operated as the DESY user facility FLASH) and the European XFEL also at DESY, and created the conditions supporting the proposals for several large SRF-based research facilities like SNS, LCLS-II, ESS, PIP-II and SHINE, as well as a growing number of smaller facilities around the world. Highlights of this 30-year international collaboration are presented and celebrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication Technologies of the High Gradient Accelerator Structures at 100MV/M Range

A CERN-SLAC-KEK collaboration on high gradient X-band structure research has been established in order to demonstrate the feasibility of the CLIC baseline design for the main linac stably operating at more than 100 MV/m loaded accelerating gradient. Several prototype CLIC structures were successfully fabricated and high power tested. They operated at 105 MV/m with a breakdown rate that meets the CLIC linear collider specifications of < 5 x 10{sup -7}/pulse/m. This paper summarizes the fabrication technologies including the mechanical design, precision machining, chemical cleaning, diffusion bonding as well as vacuum baking and all related assembly technologies. Also, the tolerances control, tuning and RF characterization will be discussed.

43 PARTICLE ACCELERATORS↗

Measurement of Thermal Dependencies of PBG Fiber Properties

Photonic crystal fibers (PCFs) represent a class of optical fibers which have a wide spectrum of applications in the telecom and sensing industries. Currently, the Advanced Accelerator Research Department at SLAC is developing photonic bandgap particle accelerators, which are photonic crystal structures with a central defect used to accelerate electrons and achieve high longitudinal electric fields. Extremely compact and less costly than the traditional accelerators, these structures can support higher accelerating gradients and will open a new era in high energy physics as well as other fields of science. Based on direct laser acceleration in dielectric materials, the so called photonic band gap accelerators will benefit from mature laser and semiconductor industries. One of the key elements to direct laser acceleration in hollow core PCFs, is maintaining thermal and structural stability. Previous simulations demonstrate that accelerating modes are sensitive to the geometry of the defect region and the variations in the effective index. Unlike the telecom modes (for which over 95% of the energy propagates in the hollow core) most of the power of these modes is located in the glass at the periphery of the central hole which has a higher thermal constant than air ({gamma}{sub SiO{sub 2}} = 1.19 x 10{sup -6} 1/K, {gamma}{sub air} = -9 x 10{sup -7} 1/K with {gamma} = dn/dT). To fully control laser driven acceleration, we need to evaluate the thermal and structural consequences of such modes on the PCFs. We are conducting series of interferometric tests to quantify the dependencies of the HC-633-02 (NKT Photonics) propagation constant (k{sub z}) on temperature, vibration amplitude, stress and electric field strength. In this paper we will present the theoretical principles characterizing the thermal behavior of a PCF, the measurements realized for the fundamental telecom mode (TE{sub 00}), and the experimental demonstration of TM-like mode propagation in the HC-633-02 fiber.

36 MATERIALS SCIENCE↗

Spiral Structure and Differential Dust Size Distribution in the LkH(alpha) 330 Disk

Dust trapping accelerates the coagulation of dust particles, and, thus, it represents an initial step toward the formation of planetesimals. We report H-band (1.6 microns) linear polarimetric observations and 0.87 mm interferometric continuum observations toward a transitional disk around LkH(alpha) 330. As a result, a pair of spiral arms were detected in the H-band emission, and an asymmetric (potentially arm-like) structure was detected in the 0.87 mm continuum emission. We discuss the origin of the spiral arm and the asymmetric structure and suggest that a massive unseen planet is the most plausible explanation. The possibility of dust trapping and grain growth causing the asymmetric structure was also investigated through the opacity index (beta) by plotting the observed spectral energy distribution slope between 0.87 mm from our Submillimeter Array observation and1.3 mm from literature. The results imply that grains are indistinguishable from interstellar medium-like dust in the east side (beta = 2.0 +/- 0.5) but are much smaller in the west side beta = 0.7+0.5 -0.4, indicating differential dust size distribution between the two sides of the disk. Combining the results of near-infrared and submillimeter observations, we conjecture that the spiral arms exist at the upper surface and an asymmetric structure resides in the disk interior. Future observations at centimeter wavelengths and differential polarization imaging in other bands (Y-K) with extreme AO imagers are required to understand how large dust grains form and to further explore the dust distribution in the disk.

polarimetric observations↗

Design and measurement of a Cu L-edge x-ray filter for free electron laser pumped x-ray laser experiments

An inner-shell photoionized x-ray laser pumped by the Linac Coherent Light Source (LCLS) free electron laser has been proposed recently. The measurement of the on-axis 849 eV Ne K{alpha} laser and protection of the x-ray spectrometer from damage require attenuation of the 1 keV LCLS beam. An Al/Cu foil combination is well suited, serving as a low energy bandpass filter below the Cu L-edge at 933 eV. A high resolution grating spectrometer is used to measure the transmission of a candidate filter with an intense laser-produced x-ray backlighter developed at the Lawrence Livermore National Laboratory Jupiter Laser Facility Janus. The methodology and discussion of the observed fine structure above the Cu L-edge will be presented.

43 PARTICLE ACCELERATORS↗

Theoretical Design of High-Brightness Photocathodes Based on Ultrathin Surface Layers on Metals and on Nanostructures

We demonstrate by means of electronic structure calculations, how ultrathin MgO films on Ag(001) surfaces can be used to control the emittance properties of photocathodes. In addition to substantially reducing the work-function of the metal surface, the MgO layers also favorably influence the shape of the surface bands resulting in the generation of well collimated high-brightness electron beams in which the transverse momenta of the electrons are extremely small compared to the longitudinal ones. As the number of MgO surface layers varies from 0 to 3, the emitted electron beam becomes gradually brighter, reducing its transverse emittance to the extremely small value of 0.06 mm-mrad. We suggest the use of such photocathodes for the development of free-electron x-ray lasers and energy-recovery linac x-ray sources. A practical implementation and further tunability through nanophotonics means is also discussed.

36 MATERIALS SCIENCE↗

Advances in X-Band TW Accelerator Structures Operating in the 100 MV/M Regime

A CERN-SLAC-KEK collaboration on high gradient X-band accelerator structure development for CLIC has been ongoing for three years. The major outcome has been the demonstration of stable 100 MV/m gradient operation of a number of CLIC prototype structures. These structures were fabricated using the technology developed from 1994 to 2004 for the GLC/NLC linear collider initiative. One of the goals has been to refine the essential parameters and fabrication procedures needed to realize such a high gradient routinely. Another goal has been to develop structures with stronger dipole mode damping than those for GLC/NLC. The latter requires that the surface temperature rise during the pulse be higher, which may increase the breakdown rate. One structure with heavy damping has been RF processed and another is nearly finished. The breakdown rates of these structures were found to be higher by two orders of magnitude compared to those with equivalent acceleration mode parameters but without the damping features. This paper presents these results together with some of the earlier results from non-damped structures.

43 PARTICLE ACCELERATORS↗

Accelerating resonant spectroscopy simulations using multishifted biconjugate gradient

Resonant spectroscopies, which involve intermediate states with finite lifetimes, provide important insights into collective excitations in quantum materials that are otherwise inaccessible. However, theoretical understanding in this area is often limited by the numerical challenges of solving Kramers-Heisenberg-type response functions for large-scale systems. To address this, we introduce a multishifted biconjugate gradient algorithm that exploits the shared structure of Krylov subspaces across spectra with varying incident energies, effectively reducing the computational complexity to that of linear spectroscopies. Both mathematical proofs and numerical benchmarks confirm that this algorithm substantially accelerates spectral simulations, achieving constant complexity independent of the number of incident energies, while ensuring accuracy and stability. This development provides a scalable, versatile framework for simulating advanced spectroscopies in quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Total Marrow Irradiation With RapidArc Volumetric Arc Therapy

Purpose: To develop a volumetric arc therapy (VMAT)-total marrow irradiation (TMI) technique for patients with hematologic malignancies. Methods and Materials: VMAT planning was performed for 6 patients using RapidArc technology. The planning target volume consisted of all the bones in the body from the head to the mid-femur, excluding the extremities, except for the humerus, plus a 3.0-mm margin. The organs at risk included the lungs, heart, liver, kidneys, bowels, brain, eyes, and oral cavity. The VMAT-TMI technique consisted of three plans: the head and neck, the chest, and the pelvis, each with three 330{sup o} arcs. The plans were prescribed to ensure, at a minimum, 95% planning target volume dose coverage with the prescription dose (percentage of volume receiving dose of {>=}12 Gy was 95%). The treatments were delivered and verified using MapCheck and ion chamber measurements. Results: The VMAT-TMI technique reported in the present study provided comparable dose distributions with respect to the fixed gantry linear accelerator intensity-modulated TMI. RapidArc planning was less subjective and easier, and, most importantly, the delivery was more efficient. RapidArc reduced the treatment delivery time to approximately 18 min from 45 min with the fixed gantry linear accelerator intensity-modulated TMI. When the prescription dose coverage was reduced to 85% from 95% and the mandible and maxillary structures were not included in the planning target volume as reported in a tomotherapy study, a considerable organ at risk dose reduction of 4.2-51% was observed. The average median dose for the lungs and lenses was reduced to 5.6 Gy from 7.2 Gy and 2.4 Gy from 4.5 Gy, respectively. Conclusion: The RapidArc VMAT technique improved the treatment planning, dose conformality, and, most importantly, treatment delivery efficiency. The results from our study suggest that the RapidArc VMAT technology can be expected to facilitate the clinical transition of TMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit

Purpose: Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. Methods and Materials: A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210 Degree-Sign of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Results: Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited <0.2 mm peak-to-peak variation. With a 0.5-mm voxel pitch, the maximum targeting error was 0.4 mm. Images of 2 patients were analyzed offline and submillimeter agreement was confirmed with conventional frame. Conclusions: A cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytical solutions for transient and steady state beam loading in arbitrary traveling wave accelerating structures

Analytical solutions are derived for both transient and steady state gradient distributions in the traveling wave (TW) accelerating structures with arbitrary variation of parameters over the structure length. The results of the unloaded and beam loaded cases are presented. Finally, the exact analytical shape of the rf pulse waveform was found in order to apply the transient beam loading compensation scheme during the structure filling time. The obtained theoretical formulas were cross-checked by direct numerical simulations on the CLIC main linac accelerating structure and demonstrated a good agreement. The proposed methods provide a fast and reliable tool for the initial stage of the TW structure analysis.

43 PARTICLE ACCELERATORS↗

The evolution of concepts of vestibular peripheral information processing: toward the dynamic, adaptive, parallel processing macular model

In a letter to Robert Hooke, written on 5 February, 1675, Isaac Newton wrote "If I have seen further than certain other men it is by standing upon the shoulders of giants." In his context, Newton was referring to the work of Galileo and Kepler, who preceded him. However, every field has its own giants, those men and women who went before us and, often with few tools at their disposal, uncovered the facts that enabled later researchers to advance knowledge in a particular area. This review traces the history of the evolution of views from early giants in the field of vestibular research to modern concepts of vestibular organ organization and function. Emphasis will be placed on the mammalian maculae as peripheral processors of linear accelerations acting on the head. This review shows that early, correct findings were sometimes unfortunately disregarded, impeding later investigations into the structure and function of the vestibular organs. The central themes are that the macular organs are highly complex, dynamic, adaptive, distributed parallel processors of information, and that historical references can help us to understand our own place in advancing knowledge about their complicated structure and functions.

Review, Tutorial↗

Recent progress on nuclear parton distribution functions

We report current status of global analyses on nuclear parton distribution functions (NPDFs). The optimum NPDFs are determined by analyzing high-energy nuclear reaction data. Due to limited experimental measurements, antiquark modifications have large uncertainties at x > 0.2 and gluon modifications cannot be determined. A nuclear modification difference between u and d quark distributions could be an origin of the long-standing NuTeV sin{sup 2}{theta}{sub w} anomaly. There is also an issue of nuclear modification differences between the structure functions of charged-lepton and neutrino reactions. Next, nuclear clustering effects are discussed in structure functions F{sub 2}{sup A} as a possible explanation for an anomalous result in the {sup 9}Be nucleus at the Thomas Jefferson National Accelerator Facility (JLab). Last, tensor-polarized quark and antiquark distribution functions are extracted from HERMES data on the polarized structure function b{sub 1} of the deuteron, and they could be used for testing theoretical models and for proposing future experiments, for example, the one at JLab. Such measurements could open a new field of spin physics in spin-one hadrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cm solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of gravitational slip on the higher-order moments of the matter distribution

Cosmological departures from general relativity offer a possible explanation for the cosmic acceleration. To linear order, these departures (quantified by the model-independent parameter {pi}, referred to as a 'gravitational slip') amplify or suppress the growth of structure in the universe relative to what we would expect to see from a general relativistic universe lately dominated by a cosmological constant. As structures collapse and become more dense, linear perturbation theory is an inadequate descriptor of their behavior, and one must extend calculations to nonlinear order. If the effects of gravitational slip extend to these higher orders, we might expect to see a signature of {pi} in the bispectrum of galaxies distributed on the sky. We solve the equations of motion for nonlinear perturbations in the presence of gravitational slip and find that, while there is an effect on the bispectrum, it is too weak to be detected with present galaxy surveys. We also develop a formalism for incorporating scale dependence into our description of gravitational slip.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of RF Feed System for Standing-Wave Accelerator Structures

We are investigating a standing wave accelerator structure that uses a rf feed to each individual cell. This approach minimizes rf power flow and electromagnetic energy absorbed by an rf breakdown. The objective of this work is a robust high-gradient (above 100 MV/m) X-band accelerator structure.

43 PARTICLE ACCELERATORS↗