Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Dosimetric Impact of Breathing Motion in Lung Stereotactic Body Radiotherapy Treatment Using Image-Modulated Radiotherapy and Volumetric Modulated Arc Therapy

Purpose: The objective of this study was to investigate the influence of tumor motion on dose delivery in stereotactic body radiotherapy (SBRT) for lung cancer, using fixed field intensity- modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods and Materials: For each of 10 patients with stage I/II non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was carried out. The internal target volume was delineated on the maximum intensity projection CT, which was reconstructed from the 4DCT dataset. A 5-mm margin was used for generation of the planning target volume. VMAT and five-field IMRT plans were generated using Pinnacle{sup 3} SmartArc and direct machine parameter optimization, respectively. All plans were generated for an Elekta Synergy linear accelerator using 6-MV photons. Simulation was performed to study the interplay between multileaf collimator (MLC) sequences and target movement during the delivery of VMAT and IMRT. For each plan, 4D dose was calculated using deformable image registration of the 4DCT images. Target volume coverage and doses to critical structures calculated using 4D methodology were compared with those calculated using 3D methodology. Results: For all patients included in this study, the interplay effect was found to present limited impact (less than 1% of prescription) on the target dose distribution, especially for SBRT, in which fewer fractions (three fractions) are delivered. Dose to the gross tumor volume (GTV) was, on average, slightly decreased (1% of prescription) in the 4D calculation compared with the 3D calculation. The motion impact on target dose homogeneity was patient-dependent and relatively small. Conclusions: Both VMAT and IMRT plans experienced negligible interplay effects between MLC sequence and tumor motion. For the most part, the 3D doses to the GTV and critical structures provided good approximations of the 4D dose calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parallel Higher-order Finite Element Method for Accurate Field Computations in Wakefield and PIC Simulations

Over the past years, SLAC's Advanced Computations Department (ACD), under SciDAC sponsorship, has developed a suite of 3D (2D) parallel higher-order finite element (FE) codes, T3P (T2P) and Pic3P (Pic2P), aimed at accurate, large-scale simulation of wakefields and particle-field interactions in radio-frequency (RF) cavities of complex shape. The codes are built on the FE infrastructure that supports SLAC's frequency domain codes, Omega3P and S3P, to utilize conformal tetrahedral (triangular)meshes, higher-order basis functions and quadratic geometry approximation. For time integration, they adopt an unconditionally stable implicit scheme. Pic3P (Pic2P) extends T3P (T2P) to treat charged-particle dynamics self-consistently using the PIC (particle-in-cell) approach, the first such implementation on a conformal, unstructured grid using Whitney basis functions. Examples from applications to the International Linear Collider (ILC), Positron Electron Project-II (PEP-II), Linac Coherent Light Source (LCLS) and other accelerators will be presented to compare the accuracy and computational efficiency of these codes versus their counterparts using structured grids.

43 PARTICLE ACCELERATORS↗

Polarized Electrons for Experiments at Low Momentum Transfer SPIN S-DALINAC

The superconducting Darmstadt linear electron accelerator S-DALINAC will be expanded by a newly developed polarized injector concept called SPIN. The polarized beam program includes experiments to search for parity violation in photo induced fission, the investigation of the 5th structure function at low momentum transfer and break up reactions of few body systems. These experiments and an overview of the current experimental program will be covered in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

(e, e'p) reaction at true quasielastic kinematics in {sup 16}O, {sup 12}C and {sup 208}Pb at JLab

The reactions {sup 16}O(e,e'p) {sup 15}N, {sup 208}Pb(e,e'p) {sup 207}Tl and {sup 12}C(e,e'p) {sup 11}B were measured in experiments E00-102 and E06-007 performed at JLab (VA, USA) at true quasielastic kinematics (x{sub B} = 1) with constant energy (omega) and momentum (q) transferred over a wide p{sub miss} range. These experiments address several open issues in nuclear structure such as the role of relativity and of long-range correlations in the description of nuclei as well as a possible dependence of the spectroscopic factors on Q{sup 2}. Preliminary experimental results and theoretical predictions from a fully relativistic DWIA model carefully averaged over the experimental acceptances are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated EM & Thermal Simulations with Upgraded VORPAL Software

Nuclear physics accelerators are powered by microwaves which must travel in waveguides between room-temperature sources and the cryogenic accelerator structures. The ohmic heat load from the microwaves is affected by the temperature-dependent surface resistance and in turn affects the cryogenic thermal conduction problem. Integrated EM & thermal analysis of this difficult non-linear problem is now possible with the VORPAL finite-difference time-domain simulation tool. We highlight thermal benchmarking work with a complex HOM feed-through geometry, done in collaboration with researchers at the Thomas Jefferson National Accelerator Laboratory, and discuss upcoming design studies with this emerging tool. This work is part of an effort to generalize the VORPAL framework to include generalized PDE capabilities, for wider multi-physics capabilities in the accelerator, vacuum electronics, plasma processing and fusion R&D fields, and we will also discuss user interface and algorithmic upgrades which facilitate this emerging multiphysics capability.

43 PARTICLE ACCELERATORS↗

Induced Radioactivity Analysis for the NSRL Linac in China Using Monte Carlo Simulations and Gamma Spectroscopy - Paper 141

The Synchrotron Radiation Facility of the National Synchrotron Radiation Laboratory (NSRL) located in Hefei, China consists of a 200-MeV electron linear accelerator and an 800-MeV electronic storage ring. Constructed in 1989, the 200-MeV Electron linac is one of the earliest high-energy electron linear accelerators in China. The NSRL is a large-scale experiment device, having been operated more than twenty years, so it is hard to give a historical recount about the injection of NSRL Linac. Lower-energy electrons emitted from the accelerator electron gun are progressively accelerated to about 200 MeV in five acceleration tubes, and then are injected into the electron storage ring, reaching the final energy of 800 MeV. The linear accelerator is a traveling wave linear accelerator, consisting of pre-injection, four 6-m acceleration segment, some beam sensing elements, and focusing inserts. The electrons are accelerated in the acceleration tubes to 32 MeV, 74 MeV, 116 MeV, 158 MeV, respectively, and the electronic energy reaches 200 MeV at the end of the acceleration trip. A scraper is used for beam collimation and is located at the end of each acceleration tube, with a length that increases with the energy to provide sufficient collimation. The NSRL Linac was retired in 2012 due to a plan to upgrade the facility. The decommissioning produced many real challenges related to the methods to handle the large size of the device and the time required to store structural materials until the radioactivity is reduced in the waste repository. These problems should be solved as soon as possible in order for the upgrade to proceed smoothly. At present, no prior decommissioning experience existed in China on such a high-energy electron linear accelerator. Therefore, the decommission project provided an opportunity to study and evaluate the challenges, in particular, involving the induced radioactivity for the purposes of radiation protection. For a well-shielded accelerator facility, the induced radioactivity is an important source of radiation for people who perform the decommissioning. In addition, information on the level of induced radioactivity is needed for disposing of the retired accelerator materials. Therefore it is significant to predict such radioactivity level accurately. However, the induced radioactivity study for such type high-energy electron linear accelerator is very seldom. Particle accelerators that operate at energy greater than 10 MeV will produce induced radioactivity due to well-known photonuclear interactions. However, the assessment of such as induced radioactivity of large-scale installations is a time-consuming process. Experimental methods are time-consuming and require special radiation safety measures to protection the investigators. On the other hand, empirical formula cannot yield sufficiently accurate results. Therefore, Monte Carlo simulation method is the primary means to study such problems. In the decommissioning process of the NSRL Linac, the induced radioactivity assessment will be based on Monte Carlo simulation method as the main auxiliary means to expand a series of studies. (authors)

43 PARTICLE ACCELERATORS↗

Numerical Verification of the Power Transfer and Wakefield Coupling in the Clic Two-Beam Accelerator

The Compact Linear Collider (CLIC) provides a path to a multi-TeV accelerator to explore the energy frontier of High Energy Physics. Its two-beam accelerator (TBA) concept envisions complex 3D structures, which must be modeled to high accuracy so that simulation results can be directly used to prepare CAD drawings for machining. The required simulations include not only the fundamental mode properties of the accelerating structures but also the Power Extraction and Transfer Structure (PETS), as well as the coupling between the two systems. Time-domain simulations will be performed to understand pulse formation, wakefield damping, fundamental power transfer and wakefield coupling in these structures. Applying SLAC's parallel finite element code suite, these large-scale problems will be solved on some of the largest supercomputers available. The results will help to identify potential issues and provide new insights on the design, leading to further improvements on the novel two-beam accelerator scheme.

43 PARTICLE ACCELERATORS↗

Design of a high power TM01 mode launcher optimized for manufacturing by milling

Recent research on high-gradient rf acceleration found that hard metals, such as hard copper and hard copper-silver, have lower breakdown rate than soft metals. Traditional high-gradient accelerating structures are manufactured with parts joined by high-temperature brazing. The high temperature used in brazing makes the metal soft; therefore, this process cannot be used to manufacture structures out of hard metal alloys. In order to build the structure with hard metals, the components must be designed for joining without high-temperature brazing. One method is to build the accelerating structures out of two halves, and join them by using a low-temperature technique, at the symmetry plane along the beam axis. The structure has input and output rf power couplers. We use a TM01 mode launcher as a rf power coupler, which was introduced during the Next Linear Collider (NLC) work. The part of the mode launcher will be built in each half of the structure. This paper presents a novel geometry of a mode launcher, optimized for manufacturing by milling. The coupler was designed for the CERN CLIC working frequency f = 11.9942 GHz; the same geometry can be scaled to any other frequency.

36 MATERIALS SCIENCE↗

Measuring the 2{gamma} Exchange Effect in Electron-Proton Scattering at CLAS

Recent results from experiments at Jefferson Laboratory, Newport News VA, which measure the ratio of the electric to magnetic form factors of the proton, G{sub E}/G{sub M}, have forced us to reexamine the single photon exchange approximation in lepton-proton elastic scattering. Discrepancies between the ratio obtained via the time-tested Rosenbluth separation method and new polarization transfer measurements, which differ by as much as a factor of three, may be resolved by considering the effect of two photon exchange (TPE). Theoretical corrections for the TPE effect are difficult due to the large number of excited nucleon states that can contribute to the process. The TPE effect can, however, be determined directly by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, R = {sigma}(e{sup +})/{sigma}(e{sup -}), since the TPE effect changes sign with the charge of the incident particle. The CLAS TPE experiment at Jefferson Laboratory, will determine the effect of two-photon exchange in elastic lepton-proton scattering by precisely measuring the ratio of positron-proton to electron-proton elastic cross sections over a large kinematic range (0.1<{epsilon}<0.96, 0.02{<=}Q{sup 2}{<=}2.0). We will accomplish this by directing the 5.5 GeV primary electron beam, provided by the Continuous Electron Beam Accelerator Facility (CEBAF), onto a set of radiators and converters to produce simultaneous and identical beams of electron and positrons. Acceptance and efficiency concerns are minimized by only considering the ratios of the elastic cross sections and switching polarity of magnets in the beam line and the spectrometer. Guided by the results of a short 2006 test run and extensive GEANT based modeling, new shielding and beam line components were designed to maximize luminosity. The unique experimental design and challenges of the TPE experiment and the projected luminosities will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmological data analysis of f(R) gravity models

A class of well-behaved modified gravity models with long enough matter domination epoch and a late-time accelerated expansion is confronted with SNIa, CMB, SDSS, BAO and H(z) galaxy ages data, as well as current measurements of the linear growth of structure. We show that the combination of geometrical probes and growth data exploited here allows to rule out f(R) gravity models, in particular, the logarithmic of curvature model. We also apply solar system tests to the models in agreement with the cosmological data. We find that the exponential of the inverse of the curvature model satisfies all the observational tests considered and we derive the allowed range of parameters. Current data still allows for small deviations of Einstein gravity. Future, high precision growth data, in combination with expansion history data, will be able to distinguish tiny modifications of standard gravity from the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization Possibilities of Small Spin-Orbit Interaction in Strained-Superlattice Photocathodes

Strained-superlattice photocathodes based on InGaP/GaAs were investigated. The photocathode performance is found highly dependent on the superlattice parameters. The electron confinement energy in superlattice appears important. The strained-superlattice structure based on GaAsP/GaAs, with a maximum polarization as high as 90% and more than 1% quantum efficiency, is presently the prime candidate for the ILC polarized electron photocathodes. A recent systematic study shows, however, that the peak polarization seems saturated even though the heavy-hole (HH) and light-hole (LH) band splitting is increased significantly, indicating that there is a material specific spin relaxation mechanism. It is widely accepted that the D'yakonov-Perel mechanism is the dominant spin relaxation mechanism in the III-V compound superlattice structures with a low p-doping ({le} 10{sup 17} cm{sup -3}), and that the spin relaxation may be reduced by choosing a material with a smaller spin-orbit interaction. As the spin-orbit interaction in phosphides is much smaller than in arsenides, strained-superlattice structure based on InGaP/GaAs were investigated. The computer code SPECCODE developed by Subashiev and Gerchikov has been used for calculating the band structures in superlattice.

36 MATERIALS SCIENCE↗

Generation of Ramped Current Profiles in Relativistic Electron Beams Using Wakefields in Dielectric Structures

We show that temporal pulse tailoring of charged-particle beams is essential to optimize efficiency in collinear wakefield acceleration schemes. In this Letter, we demonstrate a novel phase space manipulation method that employs a beam wakefield interaction in a dielectric structure, followed by bunch compression in a permanent magnet chicane, to longitudinally tailor the pulse shape of an electron beam. This compact, passive, approach was used to generate a nearly linearly ramped current profile in a relativistic electron beam experiment carried out at the Brookhaven National Laboratory Accelerator Test Facility. Here, we report on these experimental results including beam and wakefield diagnostics and pulse profile reconstruction techniques.

43 PARTICLE ACCELERATORS↗

ACE3P Computations of Wakefield Coupling in the CLIC Two-Beam Accelerator

The Compact Linear Collider (CLIC) provides a path to a multi-TeV accelerator to explore the energy frontier of High Energy Physics. Its novel two-beam accelerator concept envisions rf power transfer to the accelerating structures from a separate high-current decelerator beam line consisting of power extraction and transfer structures (PETS). It is critical to numerically verify the fundamental and higher-order mode properties in and between the two beam lines with high accuracy and confidence. To solve these large-scale problems, SLAC's parallel finite element electromagnetic code suite ACE3P is employed. Using curvilinear conformal meshes and higher-order finite element vector basis functions, unprecedented accuracy and computational efficiency are achieved, enabling high-fidelity modeling of complex detuned structures such as the CLIC TD24 accelerating structure. In this paper, time-domain simulations of wakefield coupling effects in the combined system of PETS and the TD24 structures are presented. The results will help to identify potential issues and provide new insights on the design, leading to further improvements on the novel CLIC two-beam accelerator scheme.

43 PARTICLE ACCELERATORS↗

Generation and characterization of electron bunches with ramped current profile at the FLASH facility

We report on the successful generation of electron bunches with current prof les that have a quasi-linear dependency on the longitudinal coordinate. The technique relies on impressing nonlinear correlations in the longitudinal phase space using a linac operating at two frequencies (1.3 and 3.9 GHz) and a bunch compressor. Data taken for various accelerator settings demonstrate the versatility of the method. The produced bunches have parameters well matched to drive high-gradient accelerating field with enhanced transformer ratio in beam-driven accelerators based on sub-mm-sizes dielectric or plasma structures.

36 MATERIALS SCIENCE↗

Self-Guided Laser Wakefield Acceleration beyond 1 GeV Using Ionization-Induced Injection

The concepts of matched-beam, self-guided laser propagation and ionization-induced injection have been combined to accelerate electrons up to 1.45 GeV energy in a laser wakefield accelerator. From the spatial and spectral content of the laser light exiting the plasma, we infer that the 60 fs, 110 TW laser pulse is guided and excites a wake over the entire 1.3 cm length of the gas cell at densities below 1.5x10{sup 18} cm{sup -3}. High-energy electrons are observed only when small (3%) amounts of CO{sub 2} gas are added to the He gas. Computer simulations confirm that it is the K-shell electrons of oxygen that are ionized and injected into the wake and accelerated to beyond 1 GeV energy.

43 PARTICLE ACCELERATORS↗

RECONNECTION-POWERED LINEAR ACCELERATOR AND GAMMA-RAY FLARES IN THE CRAB NEBULA

The recent discovery of day-long gamma-ray flares in the Crab Nebula, presumed to be synchrotron emission by PeV (10{sup 15} eV) electrons in milligauss magnetic fields, presents a strong challenge to particle acceleration models. The observed photon energies exceed the upper limit ({approx}100 MeV) obtained by balancing the acceleration rate and synchrotron radiation losses under standard conditions where the electric field is smaller than the magnetic field. We argue that a linear electric accelerator, operating at magnetic reconnection sites, is able to circumvent this difficulty. Sufficiently energetic electrons have gyroradii so large that their motion is insensitive to small-scale turbulent structures in the reconnection layer and is controlled only by large-scale fields. We show that such particles are guided into the reconnection layer by the reversing magnetic field as they are accelerated by the reconnection electric field. As these electrons become confined within the current sheet, they experience a decreasing perpendicular magnetic field that may drop below the accelerating electric field. This enables them to reach higher energies before suffering radiation losses and hence to emit synchrotron radiation in excess of the 100 MeV limit, providing a natural resolution to the Crab gamma-ray flare paradox.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-BRB-03: Novel Technique to Implement GRID Therapy in a Commercial Treatment Planning System

Purpose: Due to the difficulty of creating an accurate multi-aperture block in treatment planning systems (TPS), spatially fractionated radiation therapy (GRID Therapy) is limited to clinical setups using simple monitor unit calculations. In this work, we present a novel approach to accurately model a grid block in a TPS and evaluate its dosimetric accuracy. Methods: An acrylic GRID block was fashioned such that the hole size and spacing were the same dimensions of the brass GRID block (dotDecimal) at isocenter. Holes were non-divergent and drilled 1 cm deep. CT scans (RT Lightspeed, GE Healthcare) of the block were acquired using axial slices with a thickness of 0.625 mm. These were imported into Eclipse (version 11, Varian Medical Systems) and holes were auto-contoured into structures. The GRID block was created in Eclipse by forming apertures around the hole structures using a simple three step process. Treatment plans were created in a water-equivalent phantom using 6 and 10 MV beams, delivered with a linear accelerator (Clinac iX, Varian Medical Systems) and measured using a water tank, film and a diode array. Results: Comparisons of percent depth dose curves and profiles at depths of maximum dose, 5cm, and 10cm for field sizes ranging from 5 cm{sup 2} to 25 cm{sup 2} using water and film were within 3% of their respective positions in Eclipse. GRID plans utilizing various jaw sizes and MLC blocking measured with film and a diode array showed pass rates with an average of 97% using Gamma analysis at 3%/ 3 mm and no lower than 93%. Conclusion: We have developed a simple yet accurate method of incorporating a GRID block into a commercially available TPS and demonstrated that the TPS accurately reflects the dose delivered. This will allow for real-time planning using patient scans and encourage new methods for GRID therapy. Support provided by dotDecimal, Sanford, FL.

60 APPLIED LIFE SCIENCES↗