Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Designing an effective drug combination for ER stress loading in cancer therapy using a real-time monitoring system

Excess stress caused by accumulation of misfolded proteins inside the endoplasmic reticulum (ER) lumen can cause cells to undergo apoptosis. Misfolded proteins exported from ER to cytoplasm are ubiquitinated and mostly degraded by the proteasome, but can also be destroyed by autophagy mediated by the docking proteins p62 and NBR1. When misfolded proteins accumulate beyond the capacity of these clearance systems, they are transported to the microtubule organization center to form aggresomes, which are also degraded by autophagy. Together, these phenomena suggest the existence of a coordinated intracellular network for coping with the accumulation of misfolded proteins. Thus, rational inhibition of this network system might enhance killing of cancer cells subjected to pronounced ER stress loading. Based on this rationale, we sought to establish a quantitative assay for monitoring ER stress loading. MDA-MB231 cells stably transfected with the ERAI-Venus vector exhibited a strong XBP1 splicing signal in response to ER stress. Using the IncuCyte cell imaging system, we monitored the fluorescence intensity of XBP1-Venus, normalized against cell density, as an ER stress indicator. This parameter correlated closely with other reporters of unfolded protein responses. Assessment of the XBP1-Venus signal during exposure to various drug combinations revealed that simultaneous inhibition of the proteasome, autophagy, and aggresome formation led to more effective ER stress loading and higher cytotoxicity than inhibition of only two components. Our data suggest that this monitoring system is a useful tool for designing effective drug combinations for ER stress loading in cancer therapy.

60 APPLIED LIFE SCIENCES↗

Proof Of Concept of Integrated Load Measurement in 3D Printed Structures

Currently, research on structural health monitoring systems is focused on direct integration of the system into a component or structure. The latter results in a so-called smart structure. One example of a smart structure is a component with integrated strain sensing for continuous load monitoring. Additive manufacturing, or 3D printing, now also enables such integration of functions inside components. As a proof-of-concept, the Fused Deposition Modeling (FDM) technique was used to integrate a strain sensing element inside polymer (ABS) tensile test samples. The strain sensing element consisted of a closed capillary filled with a fluid and connected to an externally mounted pressure sensor. The volumetric deformation of the integrated capillary resulted in pressure changes in the fluid. The obtained pressure measurements during tensile testing are reported in this paper and compared to state-of-the-art extensometer measurements. The sensitivity of the 3D printed pressure-based strain sensor is primarily a function of the compressibility of the capillary fluid. Air- and watertightness are of critical importance for the proper functioning of the 3D printed pressure-based strain sensor. Therefore, the best after-treatment procedure was selected on basis of a comparative analysis. The obtained pressure measurements are linear with respect to the extensometer readings, and the uncertainty on the strain measurement of a capillary filled with water (incompressible fluid) is ±3.1 µstrain, which is approximately three times less sensitive than conventional strain gauges (±1 µstrain), but 32 times more sensitive than the same sensor based on air (compressible fluid) (±101 µstrain).

42 ENGINEERING↗

Automated Load Balancing Invocation Based on Application Characteristics

Performance of applications executed on large parallel systems suffer due to load imbalance. Load balancing is required to scale such applications to large systems. However, performing load balancing incurs a cost which may not be known a priori. In addition, application characteristics may change due to its dynamic nature and the parallel system used for execution. As a result, deciding when to balance the load to obtain the best performance is challenging. Existing approaches put this burden on the users, who rely on educated guess and extrapolation techniques to decide on a reasonable load balancing period, which may not be feasible and efficient. In this paper, we propose the Meta-Balancer framework which relieves the application programmers of deciding when to balance load. By continuously monitoring the application characteristics and using a set of guiding principles, Meta-Balancer invokes load balancing on its own without any prior application knowledge. We demonstrate that Meta-Balancer improves or matches the best performance that can be obtained by fine tuning periodic load balancing. We also show that in some cases Meta-Balancer improves performance by 18% whereas periodic load balancing gives only a 1.5% benefit.

Computer Science↗

Instrumentation, control and data management for the MIST (Modular Integrated Utility System) Facility

An appendix providing the technical data required for computerized control and/or monitoring of selected MIST subsystems is presented. Specific computerized functions to be performed are as follows: (1) Control of the MIST heating load simulator and monitoring of the diesel engine generators' cooling system; (2) Control of the MIST heating load simulator and MIST heating subsystem including the heating load simulator; and (3) Control of the MIST air conditioning load simulator subsystem and the MIST air conditioning subsystem, including cold thermal storage and condenser water flows.

Celino, V. A.↗

Overload protection system for power inverter

An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

Nagano, S.↗

Acoustic emission monitoring of low velocity impact damage in graphite/epoxy laminates during tensile loading

An acoustic emission (AE) system was set up in a linear location data acquisition mode to monitor the tensile loading of eight-ply quasi-isotropic graphite/epoxy specimens containing low velocity impact damage. The impact damage was induced using an instrumented drop weight tower. During impact, specimens were supported by either an aluminum plate or a membrane configuration. Cross-sectional examinations revealed that the aluminum plate configuration resulted in primarily matrix cracking and back surface fiber failure. The membrane support resulted in only matrix cracking and delamination damage. Penetrant enhanced radiography and immersion ultrasonics were used in order to assess the amount of impact damage in each tensile specimen. During tensile loading, AE reliably detected and located the damage sites which included fiber failure. All specimens with areas of fiber breakage ultimately failed at the impact site. AE did not reliably locate damage which consisted of only delaminations and matrix cracking. Specimens with this type of damage did not ultimately fail at the impact site. In summary, AE demonstrated the ability to increase the reliability of structural proof tests; however, the successful use of this technique requires extensive baseline testing.

Parker, Bradford H.↗

Damage accumulation in closed cross-section, laminated, composite structures

The need for safe, lightweight, less expensive, and more reliable launch vehicle components is being driven by the competitiveness of the commercial launch market. The United States has lost 2/3 of the commercial lunch market to Europe. As low cost Russian and Chinese vehicles become available, the US market share could be reduced even further. This international climate is driving the Single Stage To Orbit (SSTO) program at NASA. The goal of the SSTO program is to radically reduce the cost of safe, routine transportation to and from space with a totally reusable launch vehicle designed for low-cost aircraft-like operations. Achieving this goal will require more efficient uses of materials. Composite materials can provide this program with the material and structural efficiencies needed to stay competitive in the international launch market place. In satellite systems the high specific properties, design flexibility, improved corrosion and wear resistance, increased fatigue life, and low coefficient of thermal expansion that are characteristic of composite materials can all be used to improve the overall satellite performance. Some of the satellites that may be able to take advantage of these performance characteristics are the Tethered Satellite Systems (TOSCIFER, AIRSEDS, TSS2, SEDS1, and SEDS2), AXAF, GRO, and the next generation Hubble Space Telescope. These materials can also be utilized in projects at the NASAIMSFC Space Optics Technology and System Center of Excellence. The successful implementation of composite materials requires accurate performance characterization. Materials characterization data for composite materials is typically generated using flat coupons of finite width. At the free edge of these coupons the stress state is exacerbated by the presence of stiffness and geometric discontinuities. The exacerbated stress state has been shown to dominate the damage accumulation in these materials and to have a profound affect on the material constants. Space structures typically have closed cross-sections, absent of free edges. As a result, composite material characterization data generated using finite width flat specimens does not accurately reflect the performance of the composite materials used in a closed cross-section structural configuration. Several investigators have recognized the need to develop characterization techniques for composite materials in closed cross-sectioned structures. In these investigations test methods were developed and cylindrical specimens were evaluated. The behavior of the cylindrical specimens were observed to depart from behavior typical of flat coupons. However, no attempts were made to identify and monitor the progression of damage in these cylindrical specimens during loading. The identification and monitoring of damage is fundamental to the characterization of composite materials in closed cross-section configurations. In the study reported here, a closed cross-sectioned test method was developed to monitor damage progression in 2 in. diameter cylindrical specimens and 1.5 in. finite width flat coupons subjected to quasi-static, tensile loading conditions. Damage in these specimen configurations was monitored using pulse echo ultrasonic, acoustic emission, and X-ray techniques.

Bucinell, Ronald B.↗

Apollo experience report: The development of design-loads criteria, methods, and operational procedures for prelaunch, lift-off, and midboost conditions

The prelaunch, lift-off, and midboost conditions that are important to the design of spacecraft are described. Original Apollo design concepts that were deficient in realistic and accurate analysis of spacecraft structural loads in a wind environment also are included. Important improvements in design criteria, mathematical models, wind-monitoring procedures, and loads analyses are discussed. Recommendations for future programs are presented.

Mackey, A. C.↗

Strain Gage Load Calibration of the Wing Interface Fittings for the Adaptive Compliant Trailing Edge Flap Flight Test

The safety-of-flight parameters for the Adaptive Compliant Trailing Edge (ACTE) flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. This paper discusses the strain gage load calibration testing and load equation derivation methodology for the ACTE interface fittings. Both the left and right wing flap interfaces were monitored; each contained four uniquely designed and instrumented flap interface fittings. The interface hardware design and instrumentation layout are discussed. Twenty-one applied test load cases were developed using the predicted in-flight loads. Pre-test predictions of strain gage responses were produced using finite element method models of the interface fittings. Predicted and measured test strains are presented. A load testing rig and three hydraulic jacks were used to apply combinations of shear, bending, and axial loads to the interface fittings. Hardware deflections under load were measured using photogrammetry and transducers. Due to deflections in the interface fitting hardware and test rig, finite element model techniques were used to calculate the reaction loads throughout the applied load range, taking into account the elastically-deformed geometry. The primary load equations were selected based on multiple calibration metrics. An independent set of validation cases was used to validate each derived equation. The 2-sigma residual errors for the shear loads were less than eight percent of the full-scale calibration load; the 2-sigma residual errors for the bending moment loads were less than three percent of the full-scale calibration load. The derived load equations for shear, bending, and axial loads are presented, with the calculated errors for both the calibration cases and the independent validation load cases.

Miller, Eric J.↗

LabVIEW Serial Driver Software for an Electronic Load

A LabVIEW-language computer program enables monitoring and control of a Transistor Devices, Inc., Dynaload WCL232 (or equivalent) electronic load via an RS-232 serial communication link between the electronic load and a remote personal computer. (The electronic load can operate at constant voltage, current, power consumption, or resistance.) The program generates a graphical user interface (GUI) at the computer that looks and acts like the front panel of the electronic load. Once the electronic load has been placed in remote-control mode, this program first queries the electronic load for the present values of all its operational and limit settings, and then drops into a cycle in which it reports the instantaneous voltage, current, and power values in displays that resemble those on the electronic load while monitoring the GUI images of pushbuttons for control actions by the user. By means of the pushbutton images and associated prompts, the user can perform such operations as changing limit values, the operating mode, or the set point. The benefit of this software is that it relieves the user of the need to learn one method for operating the electronic load locally and another method for operating it remotely via a personal computer.

Scullin, Vincent↗

Stray-Capacitance As a Simple Tool for Monitoring and Locating Heat Generation Demonstrated in Three Superconducting Magnets

Real-time monitoring of heat loads in cryogenic systems is critical for many applications, particularly high field magnets. In this work, we demonstrated that by monitoring changes in the capacitance of local probes consisting of thin metal strips with a porous glass fiber dielectric, boiling helium from as little as 0.1 J of deposited heat can be located by an analysis of the response speed and amplitude in nearby probes. We further implemented stray-capacitance monitoring of a magnet's metal support structures, a more global probe of the magnet volumes, in three high temperature superconducting Bi-2212 magnet types. Global structural stray-capacitance monitoring was evaluated for a single racetrack coil, a common coil dipole, and a canted cosine theta winding, showing a quench response comparable to voltage signals without inductive effects. The response of the local and global probes was compared in the single racetrack coil with well-known quench properties. Monitoring the cool-down of the common coil dipole demonstrated the added benefit of the global stray-capacitance as a liquid level monitor. This simple method of monitoring the capacitance has proven to be a versatile and robust technique for monitoring and locating heat.

43 PARTICLE ACCELERATORS↗

An Impedance-Loaded Surface Acoustic Wave Corrosion Sensor for Infrastructure Monitoring

Passive surface acoustic wave (SAW) devices are attractive candidates for continuous wireless monitoring of corrosion in large infrastructures. However, acoustic loss in the aqueous medium and limited read range usually create challenges in their widespread use for monitoring large systems such as oil and gas (O&G) pipelines, aircraft, and processing plants. This paper presents the investigation of impedance-loaded reflective delay line (IL-RDL) SAW devices for monitoring metal corrosion under O&G pipeline-relevant conditions. Specifically, we studied the effect of change in resistivity of a reflector on the backscattered signal of an RDL and investigated an optimal range through simulation. This was followed by the experimental demonstrations of real-time monitoring of Fe film corrosion in pressurized (550 psi) humid CO 2 conditions. Additionally, remote monitoring of Fe film corrosion in an acidic solution inside a 70 m carbon steel pipe was demonstrated using guided waves. This paper also suggests potential ways to improve the sensing response of IL-RDLs.

47 OTHER INSTRUMENTATION↗

Aircraft signal definition for flight safety system monitoring system

A system and method compares combinations of vehicle variable values against known combinations of potentially dangerous vehicle input signal values. Alarms and error messages are selectively generated based on such comparisons. An aircraft signal definition is provided to enable definition and monitoring of sets of aircraft input signals to customize such signals for different aircraft. The input signals are compared against known combinations of potentially dangerous values by operational software and hardware of a monitoring function. The aircraft signal definition is created using a text editor or custom application. A compiler receives the aircraft signal definition to generate a binary file that comprises the definition of all the input signals used by the monitoring function. The binary file also contains logic that specifies how the inputs are to be interpreted. The file is then loaded into the monitor function, where it is validated and used to continuously monitor the condition of the aircraft.

Gibbs, Michael↗

Insecticide Exposures on Commercial Aircraft: A Literature Review and Screening Level Assessment

The objective of this project was to provide initial estimates of the relationship between insecticide use on passenger aircraft and exposure levels present in the cabin environment. The work was initially divided into three tasks including 1) a review of insecticide application practices in commercial aircraft, 2) exploratory measurements of insecticide concentrations in treated aircraft and 3) screening level exposure modeling. Task 1 gathered information that is needed to assess the time-concentration history of insecticides in the airline cabin. The literature review focused on application practices, information about the cabin environment and existing measurements of exposure concentrations following treatment. Information from the airlines was not available for estimating insecticide application rates in the U.S. domestic fleet or for understanding how frequently equipment rotate into domestic routes following insecticide treatment. However, the World Health Organization (WHO) recommends several methods for treating aircraft with insecticide. Although there is evidence that these WHO guidelines may not always be followed, and that practices vary by airline, destination, and/or applicator company, the guidelines in combination with information related to other indoor environments provides a plausible basis for estimating insecticide loading rates on aircraft. The review also found that while measurements of exposure concentrations following simulated aerosol applications are available, measurements following residual treatment of aircraft or applications in domestic aircraft are lacking. Task 2 focused on developing an approach to monitor exposure concentrations in aircraft using a combination of active and passive sampling methods. An existing active sampling approach was intended to provide data immediately following treatment while a passive sampler was developed to provide wider coverage of the fleet over longer sampling periods. The passive sampler, based on a thin-film polymer-coated glass design, was developed specifically for deployment in the airliner ventilation system for long-term unattended monitoring of insecticide loading in the aircraft. Because access was not available for either treated aircraft or treatment records during the course of this study, the development and calibration of the passive samplers was halted prior to completion. Continued development of a field ready passive sampler for insecticides in aircraft would require collaboration with the airline industry to finalize the method for deployment and calibration conditions for the sampler. The Task 3 screening level modeling assessment used a dynamic two-box mass balance model that includes treated surfaces and air to explore the time-concentration history of insecticides in the cabin. The model was parameterized using information gathered during the literature review and run for several different insecticide use scenarios. Chemical degradation or sequestration in the surface compartment and mass transfer from the surface to the air limit the rate at which insecticides are removed from the system. This rate limiting process can result in an accumulation of insecticide in the airliner cabin following repeated applications. The extent of accumulation is a function of the overall persistence of the chemical in the system and the amount of chemical applied during each treatment.

54 ENVIRONMENTAL SCIENCES↗

Designing an autonomous environment for mission critical operation of the EUVE satellite

Since the launch of NASA's Extreme Ultraviolet Explorer (EUVE) satellite in 1992, there has only been a handful of occurrences that have warranted manual intervention in the EUVE Science Operations Center (ESOC). So, in an effort to reduce costs, the current environment is being redesigned to utilize a combination of off-the-shelf packages and recently developed artificial intelligence (AI) software to automate the monitoring of the science payload and ground systems. The successful implementation of systemic automation would allow the ESOC to evolve from a seven day/week, three shift operation, to a seven day/week one shift operation. First, it was necessary to identify all areas considered mission critical. These were defined as follows: (1) The telemetry stream must be monitored autonomously and anomalies identified. (2) Duty personnel must be automatically paged and informed of the occurrence of an anomaly. (3) The 'basic' state of the ground system must be assessed. (4) Monitors should check that the systems and processes needed to continue in a 'healthy' operational mode are working at all times. (5) Network loads should be monitored to ensure that they stay within established limits. (6) Connectivity to Goddard Space Flight Center (GSFC) systems should be monitored as well, not just for connectivity of the network itself but also for the ability to transfer files. (7) All necessary peripheral devices should be monitored. This would include the disks, routers, tape drives, printers, tape carousel, and power supplies. (8) System daemons such as the archival daemon, the Sybase server, the payload monitoring software, and any other necessary processes should be monitored to ensure that they are operational. (9) The monitoring system needs to be redundant so that the failure of a single machine will not paralyze the monitors. (10) Notification should be done by means of looking though a table of the pager numbers for current 'on call' personnel. The software should be capable of dialing out to notify, sending email, and producing error logs. (11) The system should have knowledge of when real-time passes and tape recorder dumps will occur and should know that these passes and data transmissions are successful. Once the design criteria were established, the design team split into two groups: one that addressed the tracking, commanding, and health and safety of the science payload and another group that addressed the ground systems and communications aspects of the overall system.

Abedini, Annadiana↗

Short-crack growth behaviour in an aluminum alloy: An AGARD cooperative test program

An AGARD Cooperative Test Program on the growth of short fatigue cracks was conducted to define the significance of the short-crack effect, to compare test results from various laboratories, and to evaluate an existing analytical crack-growth prediction model. The initiation and growth of short fatigue cracks (5 micrometer to 2 mm) from the surface of a semi-circular notch in 2024-T3 aluminum alloy sheet material were monitored under various load histories. The cracks initiated from inclusion particle clusters or voids on the notch surface and generally grew as surface cracks. Tests were conducted under several constant-amplitude (stress ratios of -2, -1, 0, and 0.5) and spectrum (FALSTAFF and Gaussian) loading conditions at 3 stress levels each. Short crack growth was recorded using a plastic-replica technique. Over 250 edge-notched specimens were fatigue tested and nearly 950 cracks monitored by 12 participants from 9 countries. Long crack-growth rate data for cracks greater than 2 mm in length were obtained over a wide range in rates (10 to the -8 to 10 to the -1 mm/cycle) for all constant-amplitude loading conditions. Long crack-growth rate data for the FALSTAFF and Gaussian load sequences were also obtained.

Newman, J. C., Jr.↗

Electrochemical Response of Alkaline Batteries Subject to Quasi-Static and Dynamic Loading

We report electrochemical changes were successfully monitored through the coupling of external loading, electrochemical impedance spectroscopy (EIS), and distribution of relaxation times (DRT) analysis. The development of the testing methods allows for detailed observation of changes due to mechanical loading and distinguishes responses between different cell geometries. Comparison of the force vs displacement, voltage vs displacement, and distribution of relaxation times plots to the different cell geometries display failure modes specific to geometry as well as the impact of different loading profiles. Numerical modeling confirmed the movement within individual cells and predicted locations with the most deformation based on the external loading condition applied. The results gathered from combining mechanical loading, electrochemical response, and numerical modeling, yield a viable approach to establishing an improved understanding of the effects of mechanical loading on the electrochemical response of multiple battery geometries and the methods herein may be extensible to additional battery chemistries.

25 ENERGY STORAGE↗

Carbon Nanotube Coatings as Used in Strain Sensors for Composite Tanks

The next generation of cryogenic fuel tanks, crew habitats and other components for future spacecraft will focus on the usc of lightweight carbon fiber composite materials. A critical issue in the design and optimization of such tanks and structures will bc in structural health monitoring, however, current strain sensors have limitations. In this study, a novel carbon nanotube thin film was applied to carbon fiber composites for structural monitoring. Applying a load using a 3-point bend test to simulate bowing of a tank wall, induced significant increases in the film's electrical resistance at small deflections. Upon release of the load, the resistance returned to its approximate start value and was reproducible over multiple tests. The results show that a carbon nanotube thin film has great potential for the health monitoring of composite structures.

Trigwell, Steve↗