Search NASA⌕ Search

SEARCH · Search NASA

Results for “Loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Nonsteady Load Responses of Wind Turbines to Atmospheric and Mountain-Generated Turbulence Eddies, With Impacts on the Main Bearing: A Validation Study

Previous computational and field experiments identify three characteristic time scales in the aerodynamic responses of utility-scale wind turbine loads to atmospheric boundary layer (ABL) turbulence: a 30-90 second time scale for the passage of high/low speed "streaks" through the rotor plane, the blade and rotor rotation time scales (approximately 1 to 5 seconds), and a sub-second time scale created by blade rotation through gradients within eddy coherent structure. In the current study we compare aerodynamic load responses from daytime ABL turbulence quantified with large-eddy simulation and a actuator line model of the NREL 5 MW wind turbine with analysis of field data from the NREL/GE 1.5 MW wind turbine 5 kilometers east of the Rocky Mountain Front Range in Colorado. In addition, we contrast the responses to the passage of the mountain-generated eddies embedded within the westerly winds with the ABL eddies embedded within northerly/southerly winds. These analyses are in context with the nonsteady forcing of the main bearing by the aerodynamic generation of nontorque bending moments on the main shaft. Potentially relevant to main bearing failure mechanisms, both computational and field data show that the magnitudes of turbulence-generated nontorque bending moments, that we show generate nonsteady force on the main bearing, are of order, and often larger than, torque (which underlies power). However, the temporal variations in these two responses are uncorrelated, implying that the aerodynamic mechanisms that drive power and main bearing response are fundamentally different. We find this to be the case in the field with both mountain-generated eddies (westerly winds) and ABL-generated eddies (northerly/southerly winds). Whereas the time and length scales are comparable, the mountain eddies were somewhat more energetic than the northerly/southerly ABL eddies. Interestingly, however, the fluctuations in nontorque bending moment that force the main bearing were found to be stronger when forced by the ABL eddies than the mountain eddies. The field studies validate the key results from the computational study and show even stronger response in the nontorque bending moment than in the computer simulations. In all cases, the torque and nontorque bending moments are temporally uncorrelated, torque and power are driven by time variations in rotor-averaged horizontal wind velocity and nontorque bending moments are driven by time changes in the degree of nonuniformity in the distribution of velocity over the rotor plane. Thus the results generalize the mechanisms underlying nonsteady aerodynamic forcing to classes of turbulence eddy types with strength of order or stronger than ABL eddies with transverse scale of order the wind turbine rotor. These include atmospheric turbulence eddies, topography-generated turbulence eddies and, by extension, impacts of turbine-wake-scale turbulence eddies on downstream wind turbine rotors.

17 WIND ENERGY↗

Evaluation of 304L stainless steel deformation and failure under cyclic loading

The motivation for this work came from the simulation of components subjected to impact. In these problems, repeated loading can be generated by vibrational motion between internal parts of the component or by the occurrence of multiple impacts. Graphs of tensile equivalent plastic strain $(\overline{\varepsilon}_T^\rho)$ versus time from such cases had the character shown in Fig. 1. The equivalent plastic strain grew by alternating periods of accumulation and hold. The periods of hold indicate times when $d\overline{\varepsilon}_T^\rho$ did not accumulate. This can be due to the material unloading into the elastic range, or actually plastically reverse loading with hydrostatic stress σ h < 0 as was demonstrated for an impact simulation. Similar observations were made from the simulation of a 2-degree-of-freedom mass-elastic-plastic-spring system subjected to impact.

36 MATERIALS SCIENCE↗

New Results on Communication- and Memory-Aware Load Balancing Model and Algorithms

While load balancing in distributed-memory computing has been well-studied, we present an innovative approach to this problem: a unified, reduced-order model that combines three key components to describe “work” in a distributed system: computation, communication, and memory. Our model enables an optimizer to explore complex tradeoffs in task placement, such as augmented parallelism, at the expense of data replication increasing memory usage. We propose a fully distributed, heuristic-based load balancing optimization algorithm, and demonstrate that it quickly finds close-to-optimal solutions. We formalize the complex optimization problem as a mixed-integer linear program, and compare it to our strategy. Finally, we show that when applied to an electromagnetics code, our approach obtains up to 2.3x speedups for the imbalanced execution.

97 MATHEMATICS AND COMPUTING↗

EV Charging Infrastructure Energization: An Overview of Approaches for Simplifying Processes and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure and electricity. Growth in electricity demand from EV charging, coupled with growth in other sectors like data centers and electrification of other sectors, is impacting electricity infrastructure and load service request processes after two decades of relatively flat electricity demand. While most electric vehicle charging occurs at home, enroute and depot charging for medium and heavy-duty vehicles, both using high-powered EV charging, are critical to meet electric vehicle operational needs. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have expressed distress that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Apex Study: Compensating Transient Beam Loading in the RHIC 28 MHZ

With the EIC on the way, it is important that developments and strategies are in place to deal with the very high beam currents that the machine will feature. Specifically, the EIC will collide beams of up to 2.5 A, three times the beam current in RHIC. This higher beam current will cause significant voltage transients in the cavity fields which can lead to longitudinal instabilities and beam loss. In anticipation of these negative effects, studies were carried out on the RHIC 28 MHz cavities using newly developed firmware and software to diagnose and combat beam loading. Diagnostic tools such as the bunch-by-bunch (BbyB) ADC firmware and digital network analyzer (DNA) were used to characterize the closed loop system and transient on the cavity voltage magnitude and phase. Then, a one-turn delay feedback (OTFB) and adaptive feed-forward (aFFWD) were used to minimize the transient beam loading. The studies were carried out with beam during 2 accelerator physics experiements (APEXs) using one of the 28 MHz accelerating cavities here at RHIC.

43 PARTICLE ACCELERATORS↗

ACT University Collaboration Proposal: Role of manufacturing defects on material failure under dynamic loading for developing enhanced failure models and theories (Final Report)

Research on the tensile behavior of additively manufactured 316L stainless steel coupon specimens at increasing strain rates was conducted over the past year at Penn State. Dynamic loading rates into the 1000 1/s loading rates were performed on specimens with nearly 1.32” gage lengths. Stress-strain plots show ductile and plastic behavior well beyond 12% strain with necked specimens, having smaller effective gage lengths showing up to 56% ultimate strain. Additional tests performed on compact tension specimens helped with simulation work to understand the deformation behavior. Using finite elements, it was possible to determine the feasibility of a comprehensive experimental validation study towards an improved model for AM material failure – specifically, the Bai-Wierzbicki approach which accounts for lode angle and triaxiality. A non-significant number of tests are projected for eight specific failure nodes, with additional replicates to provide strain-rate capabilities to the existing formulation. One such correction factor is explored for quasi-static, notched specimens. Finally, stress intensity factor was explored using a set of compact-tension specimens which would also provide useful validation data for any simulation work.

36 MATERIALS SCIENCE↗

2026 Large Load Literature Review and Data Sources [Slides]

The Large Load Literature Review and Data Sources reports are updated monthly, summarizing reports and data published in 2026 that focus on large loads. The 2025 literature review reviewed and categorized over 90 resources into 12 themes.

97 MATHEMATICS AND COMPUTING↗

The Effect of a Reduction in the Catalyst Loading on a Mini Passive Direct Methanol Fuel Cell

Mini passive direct methanol fuel cells (mpDMFCs) appear to be a promising alternative for powering portable devices, since they use a liquid fuel, have a fast refuelling time, have a high efficiency and have a low environmental impact. However, some issues need to be solved before their commercialization, such as methanol crossover, short lifetime and high costs. The present work studies the effect of reducing the anode and cathode catalyst loading on the performance of a mpDMFC towards a reduction in the system costs and the characterization of the system losses. The undesirable losses that affect the fuel cell performance were identified and quantified using the electrochemical impedance spectroscopy (EIS) technique. Accordingly, a novel equivalent electric circuit (EEC) was proposed, accurately reproducing the mini pDMFC. In this work, a maximum power density of 7.07 mW cm−2 was obtained, with a methanol concentration of 5 M, using 2 mg cm−2 Pt-RuB and 4 mg cm−2 PtB. The mpDMFC allowed the cell to work with high methanol concentrations and reduced anode catalyst loadings.

Moreira, C. S.↗

Subsurface hydrological controls on the short-term effects of hurricanes on nitrate–nitrogen runoff loading: a case study of Hurricane Ida using the Energy Exascale Earth System Model (E3SM) Land Model (v2.1)

When the nutrient level in the soil surpasses vegetation demand, nutrient losses due to surface runoff and subsurface leaching are the major reasons for the deterioration of water quality. The lower Mississippi River basin (LMRB) is one of the sub-basins that deliver the highest nitrogen loads to the Gulf of Mexico. Potential changes in episodic events induced by hurricanes may exacerbate water quality issue in the future. However, uncertainties in modeling the hydrologic response to hurricanes may limit the modeling of nutrient losses during such events. Using a machine learning approach, we calibrated the land component of the Energy Exascale Earth System Model (E3SM), or ELM, version 2.1, based on the water table depth (WTD) of a calibrated 3D subsurface hydrology model. While the overall performance of the calibrated ELM is satisfactory, some discrepancies in WTD remain in slope areas with low precipitation due to the missing lateral flow process in ELM. Simulations including biogeochemistry performed using ELM with and without model calibration showed important influences of soil hydrology, precipitation intensity, and runoff parameterization on the magnitude of nitrogen runoff loss and the leaching pathway. Despite such sensitivities, both ELM simulations produced reduced WTD and increased runoff and accelerated nitrate–nitrogen runoff loading during Hurricane Ida in August 2021, consistent with the observations. With observations suggesting more pronounced effects of Hurricane Ida on nitrogen runoff than the simulations, we identified factors for model improvement to provide a useful tool for studying hurricane-induced nutrient losses in the LMRB region.

54 ENVIRONMENTAL SCIENCES↗

System and method for using mechanical loading to create spatially patterned meta surfaces for optical components

The present disclosure relates to a system for producing a patterned nanostructured surface on a component from a pre-existing, nanostructured surface with a first spatial feature distribution on the component. The system makes use of a force application element configured to apply a force to the pre-existing, nanostructured surface, and a force application control subsystem. The force application control subsystem is configured to control elevational movement of the force application element along a first axis of movement into and out of contact with the pre-existing, nanostructured surface to apply a predetermined load to the pre-existing, nanostructured surface. The predetermined load is sufficient to modify the pre-existing, non-patterned nanostructured surface to create the patterned nanostructured surface.

Ray, Nathan James↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Load summary table for all sites

Summary peak load for all analyzed sites as part of study. The results are presented in 5 year increments

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lithium‐Containing Hybrid SEI Layer Enabling High Mass Loading and Anode‐Less Sodium Metal Batteries

The continuous rupturing and rebuilding of unstable solid electrolyte interphase (SEI) layer during cycling would block Na + diffusion and induce Na dendrite formation, ultimately limiting the practical application of high-energy-density sodium metal batteries. Herein, a hybrid SEI layer containing Li-species is dexterously constructed on the surface of sodium metal anode. Li-containing inorganic components (Li 3 N, LiF, and Li 2 CO 3 ) are introduced to stabilize the Na/electrolyte interface and enhance the mechanical and diffusion kinetic properties of the SEI layer, which can reduce the side reactions and gas generation, regulate Na + flux during cycling and promote rapid Na + migration for uniform dendrite-free Na deposition. As a result, the constructed Na symmetric cells achieve low overpotential and long cycle life of 5900, 1800, and 500 h at current densities of 3, 10, and 30 mA cm −2 , respectively. Furthermore, the full cells paired with the Na₃V₂(PO₄)₃ cathode demonstrate high specific capacity and excellent cycle stability, even at an ultra-high cathode loading of 39.3 mg cm −2 and a low N/P ratio (negative/positive electrode capacity ratio of 1.21).

Diffusion kinetic↗