Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Magnet Architectures and Active Radiation Shielding Study (MAARSS)

This report describes the analysis of several magnetic radiation shield architectures and the spacecraft systems associated with them, such as quench detection, thermal management, and compensation coils. This work was performed as part of the NASA Institute of Advanced Concepts (NIAC) Grant Phase II effort. Because radiation exposure during long duration space missions poses a significant risk for crewed space-flight, Advanced Magnetic Lab, Inc. (AML) and NASA are studying magnetic radiation shielding, which may generate low-mass protection. Recent technological developments in high-temperature superconducting technology suggest the possibility of such shielding. This report analyzes some of the technical difficulties involved in such a system and identifies technology areas where further investment would be warranted. Most analysis was performed on a baseline configuration (8-meter diameter coils, with 1 tesla field). However, a baseline design with an expandable coil configuration (16 meter diameter coils, 1.5 tesla field) has a significant potential to increase shielding efficiency. The magnetic forces on the magnetic shield's components are large enough to require detailed structural design. Analysis of the thermal structural response of a yttrium-barium-copper-oxide (YBCO) high-temperature, superconducting (HTS) tape in a large-scale solenoid magnet showed that structural and thermal performance improved by replacing Hastelloy® with graphene in the tape. Integrating graphene into the high-strength fiber (HSF) support structure brings even greater benefits. The energy stored in a shield system's magnetic field must be safely dissipated if a quench-type failure occurs. Analysis of quench detection by fiber-optic thermal sensing and improvement of quench characteristics using graphene showed quench is manageable. Low-temperature superconductors can quench when subjected to movement, but lab tests of coil expansion testing showed that HTS materials do not quench when subject to the movement associated with coil expansion. Compensation coils are necessary to reduce the magnetic field in the crew habitat. Analysis showed that subdividing the compensation coil into individually controlled sections allows for a robust, adjustable system. AML analyzed the forces on an approaching capsule that were a result of eddy currents in its structure induced by its motion through the magnetic field from the coils. AML also analyzed coil-to-coil forces. Thermal control to maintain the HTS material at a suitable temperature is challenging. The sunshield technology review revealed a greater possibility of thermal insulation of the coils and use of passive cooling. The availability of suitable cryocoolers was also reviewed. A parametric graph estimating mass and shielding effectiveness for strength and thickness was developed, and allows spacecraft designers to assess the tradeoffs of using a magnetic radiation shield.

Spacecraft↗

Design of JET ELM control coils for operation at 350 degrees C

A study has confirmed the feasibility of designing, fabricating and installing resonant magnetic field perturbation (RMP) coils in JET(1) with the objective of controlling edge localized modes (ELM). A system of two rows of in-vessel coils, above the machine midplane, has been chosen as it not only can investigate the physics of and achieve the empirical criteria for ELM suppression, but also permits variation of the spectra allowing for comparison with other experiments. These coils present several engineering challenges. Conditions in JET necessitate the installation of these coils via remote handling, which will impose weight, dimensional and logistical limitations. And while the encased coils are designed to be conventionally wound and bonded, they will not have the usual benefit of active cooling. Accordingly, coil temperatures are expected to reach 350 degrees C during bakeout as well as during plasma operations. These elevated temperatures are beyond the safe operating limits of conventional OFHC copper and the epoxies that bond and insulate the turns of typical coils. This has necessitated the use of an alternative copper alloy conductor C18150 (CuCrZr). More importantly, an alternative to epoxy had to be found. An R&D program was initiated to find the best available insulating and bonding material. The search included polyimides and ceramic polymers. The scope and status of this R&D program, as well as the critical engineering issues encountered to date are reviewed and discussed.

36 MATERIALS SCIENCE↗

Status of MSBS study at NAL

Two Magnetic Suspension and Balance Systems (MSBS) at the National Aerospace Laboratory (NAL) in Japan are introduced. They are the 10 cm MSBS and the 60 cm MSBS. They have 10 cm x 10 cm and 60 cm x 60 cm test sections. The control of suspending a model at the 10 cm MSBS is six degrees of freedom including the rolling moment control. The model for the rolling moment control has two pairs of small extra permanent magnets at both its ends plus a main cylindrical magnet. The rolling moment is generated by the magnetic forces acting on the extra magnets by controlled current passing through the four side coils independently. Test results show the roll angle of the model is controlled in this way. The dynamic calibration test was carried out at the MSBS in five degrees of freedom without the rolling moment control. The model is a simple cylindrical magnet magnetized along its axis. The obtained results show that the dynamic calibration with measured magnetic field intensity is much superior to that with the coil currents. The 60 cm MSBS was designed with some data obtained at the 10 cm one. It is fundamentally proportional to the 10 cm one in size and coil positions. The measured magnetic field intensity is not so strong as expected at design. It was operated first in 1993. The control is three degrees of freedom in the longitudinal direction.

Sawada, Hideo↗

Systems and methods for wireless temperature sensing

Wireless temperature sensing systems and methods include an active sensor for determining temperature parameters in harsh environments, such as in very high temperature conditions, and wireless conveyance of the detected parameters. In an example embodiment, a pyroelectric element can generate a voltage when subjected to a temperature change. A coil is electrically coupled to the pyroelectric element and configured to generate a magnetic field in response to a current induced by the voltage generated by the pyroelectric element. A pickup is electromagnetically coupled with and detects the magnetic field generated by the coil, and the pickup is configured to provide an output corresponding to the detected magnetic field.

Lin, Yirong↗

Dosimetric evaluation for exposure of patient to a z-gradient coil in magnetic resonance imaging

In magnetic resonance imaging, time-varied gradient magnetic fields may stimulate nerves and muscles by inducing electric fields and currents in patients, which may potentially cause health problems. In this paper, a realistic z-gradient coil was numerically designed and the exposure level in a 3D real human man model was calculated by using the impedance method. It was found that the z-gradient coil produces a magnetic flux density (B-field) with two regions of good homogeneity along the coil length, separated by a very weak B-field in the middle of the coil. The spatially averaged B-field is 281 times greater than that of the International Commission on Non-Ionizing Radiation Protection's (ICNIRP) reference level. The 1-cm{sup 2}-averaged induced current density in the central nervous system is 87 times greater than that of the ICNIRP's basic restriction. The maximum current density in all of the body tissues is above the nerve stimulation threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical analysis of the electrical aspects of the basic electro-impulse problem in aircraft de-icing applications

A method of modelling a system consisting of a cylindrical coil with its axis perpendicular to a metal plate of finite thickness, and a simple electrical circuit for producing a transient current in the coil, is discussed in the context of using such a system for de-icing aircraft surfaces. A transmission line model of the coil and metal plate is developed as the heart of the system model. It is shown that this transmission model is central to calculation of the coil impedance, the coil current, the magnetic fields established on the surfaces of the metal plate, and the resultant total force between the coil and the plate. FORTRAN algorithms were developed for numerical calculation of each of these quantities, and the algorithms were applied to an experimental prototype system in which these quantities had been measured. Good agreement is seen to exist between the predicted and measured results.

Henderson, Robert A.↗

Integrated Orbit and Attitude Control for a Nanosatellite with Power Constraints

HokieSat is a NASA Goddard sponsored spacecraft currently being built by students at Virginia Tech. HokieSat is part of the Ionospheric Observation Nanosatellite Formation (ION-F) project. The project involves spacecraft built by three schools: Virginia Tech (VT), Utah State University (USU), and University of Washington (UW). The three spacecraft are similar in design and will perform formation flying demonstrations, and make ionospheric measurements. HokieSat uses Pulsed Plasma Thrusters (PPTs) to maintain its position in the formation. There are two pairs of PPTs on HokieSat; their position on HokieSat's hexagonal cross-section is shown. Thrusters T(sub 2) and T(sub 3) provide translation control, and Thrusters TI and T4 can provide yaw steering. Any thruster can be fired individually. However because they share a capacitor, thrusters T(sub 1) and T(sub 2) or thrusters T(sub 3) and T(sub 4) cannot be fired simultaneously. Thrusters T(sub 2) T(sub 3) can be fired simultaneously, as well as thrusters T(sub 1) and T(sub 4). Each thruster provides an impulse-bit of 56 micronN-s and fires at a rate of 1 Hz. For translation control thrusters T2 and T3 are fired together providing an impulse-bit of 112 micronN-s. All four thrusters are positioned slightly above the center of mass, and therefore exert a torque on the spacecraft. Because there are no thrusters in the zenith-nadir directions, and the communication system requires that the spacecraft remain nadir-pointing, there is no way to thrust in the radial direction. The attitude of HokieSat is controlled by 3 orthogonal magnetic torque coils. Attitude control is achieved by forcing a current through the torque coils, which interacts with the Earth's magnetic field and creates a torque. Due to magnetic field interactions between the coils and PPTs, the two actuator systems cannot be used simultaneously, and any attitude or orbit control must be performed in a piecewise fashion. Power limitations place an additional constraint on the HokieSat control subsystem. When the spacecraft is in eclipse, the power subsystem can provide only enough power to operate vital spacecraft functions.

Berry, Matthew M.↗

Inductively coupled 30 T magnetic field platform for magnetized high-energy-density plasma studies

A pulsed high magnetic field device based on the inductively coupled coil concept [D. H. Barnak et al., Rev. Sci. Instrum. 89, 033501 (2018)] is described. The device can be used for studying magnetized high-energy-density plasma and is capable of producing a pulsed magnetic field of 30 T inside a single-turn coil with an inner diameter of 6.5 mm and a length of 6.3 mm. The magnetic field is created by discharging a high-voltage capacitor through a multi-turn solenoid, which is inductively coupled to a small single-turn coil. The solenoid electric current pulse of tens of kA and a duration of several μs is inductively transformed to hundreds of kA in the single-turn coil, thus enabling a high magnetic field. Unlike directly driven single-turn systems that require a high-current and low-inductive power supply, the inductively coupled system operates using a relatively low-current power supply with very relaxed requirements for its inductance. Finally, this arrangement significantly simplifies the design of the power supply and also makes it possible to place the power supply at a significant distance from the coil. In addition, the device is designed to contain possible wire debris, which makes it attractive for debris-sensitive applications.

47 OTHER INSTRUMENTATION↗

Optimization of passive superconductors for shaping stellarator magnetic fields

Here, we consider the problem of optimizing a set of passive superconducting coils (PSCs) with currents induced by a background magnetic field rather than power supplies. In the nuclear fusion literature, such coils have been proposed to partially produce the 3D magnetic fields for stellarators and provide passive stabilization. We perform the first optimizations of PSC arrays with respect to the orientation, shape, and location of each coil, jointly minimized with the background fields. We conclude by generating passive coil array solutions for four stellarators.

coil optimization↗

Efficient calculation of self magnetic field, self-force, and self-inductance for electromagnetic coils with rectangular cross-section

Abstract For designing high-field electromagnets, the Lorentz force on coils needs to be computed in order to design suitable support structures, and the inductance should be computed to evaluate the stored energy and dynamics. Also, the magnetic field and its variation inside the conductor is of interest for computing stress and strain, and due to superconducting quench limits. For these force, inductance, energy, and internal field calculations, the coils cannot be naively approximated as infinitesimally thin filaments due to divergences when the source and evaluation points coincide, so more computationally demanding calculations are usually required, resolving the finite cross-section of the conductors. Here, we present a new alternative method that enables the internal magnetic field vector, self-force, and self-inductance to be computed rapidly and accurately within a 1D filament model. The method is applicable to coils for which the curve center-line can have general noncircular shape, as long as the conductor width is small compared to the radius of curvature. This paper extends a previous calculation for circular-cross-section conductors (Hurwitz et al 2024 IEEE Trans. Magn. ) to consider the case of rectangular cross-section. The reduced model is derived by rigorous analysis of the singularity, regularizing the filament integrals such that they match the true high-dimensional integrals at high coil aspect ratio. The new filament model exactly recovers analytic results for a circular coil, and is shown to accurately reproduce full finite-cross-section calculations for a non-planar coil of a stellarator magnetic fusion device. Due to the efficiency of the model here, it is well suited for use inside design optimization.

Landreman, Matt (ORCID:000000027233577X)↗

Stochastic and a posteriori optimization to mitigate coil manufacturing errors in stellarator design

Abstract It was recently shown in Wechsung et al (2022 Proc. Natl Acad. Sci. USA 119 e2202084119) that there exist electromagnetic coils that generate magnetic fields, which are excellent approximations to quasi-symmetric fields and have very good particle confinement properties. Using a Gaussian process-based model for coil perturbations, we investigate the impact of manufacturing errors on the performance of these coils. We show that even fairly small errors result in noticeable performance degradation. While stochastic optimization yields minor improvements, it is not possible to mitigate these errors significantly. As an alternative to stochastic optimization, we then formulate a new optimization problem for computing optimal adjustments of the coil positions and currents without changing the shapes of the coil. These a-posteriori adjustments are able to reduce the impact of coil errors by an order of magnitude, providing a new perspective for dealing with manufacturing tolerances in stellarator design.

Physics↗

System and method for alfvenic reconnecting plasmoid plasma acceleration

According to various embodiments, a system for using magnetic reconnection to accelerate plasma is disclosed. The system includes a pair of electrodes including two concentric rings separated by an electrode gap and held at different electrostatic potential by applying a voltage to generate an inter-electrode electric field. The system further includes a plurality of magnetic coils configured to produce magnetic field lines that connect the pair of electrodes. The system additionally includes a gas injector configured to inject gas into the electrode gap, the injected gas being partially ionized by the inter-electrode electric field to generate a poloidal current that flows along open magnetic field lines across the electrode gap. A total Lorentz force causes oppositely directed magnetic field lines to be expanded around a region of the gas injector to further create an azimuthal current in the form of an axially elongated current sheet that is unstable such that the axially elongated current sheet reconnects and breaks into plasmoids.

Ebrahimi, Fatima Arezu↗

A 50 kA Superconducting Transformer for the Upcoming High-Field High-Current Testing Station at the BNL

Brookhaven national laboratory is upgrading its existing user facility to support R&D for High Energy Physics (HEP) and Fusion Energy Sciences (FES). The goal of this upgrade is to host the testing of the superconducting cables, conductors, joints and insert coils under high magnetic field (10 T), with currents up to 50 kA (present limit 20 kA) and at temperatures varying from 4 K to 40 K. To provide a current up to 50 kA to the sample, a superconducting core-less transformer is under construction. The superconducting transformer would additionally reduce the heat loss at the current leads at high currents. The SC transformer consists of two coaxial coils. The primary coil is inside the secondary coil. The primary coil consists of 3048 turns of rectangular wires (1.91 mm x 1.27 mm), wound in 24 layers. The secondary coil consists of 13 turns of the secondary cable (18.35 mm x 5.96 mm), wound in one layer. The parameters of the transformer are chosen to satisfy the space restrictions while using the available conductor. Here this paper presents the design of the 50-kA transformer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Radiation Environment Nuclear Fragment Separator Magnet

Superconducting coils wound with HTS conductor can be used in magnets located in a high radiation environment. NbTi and Nb 3 Sn superconductors must operate at 4.5 K or below where removal of heat is less efficient. The HTS conductor can carry significant current at higher temperatures where the Carnot efficiency is significantly more favorable and where the coolant heat capacity is much larger. Using the HTS conductor the magnet can be operated at 40 K. This project examines the use of HTS conductor for the Michigan State University Facility For Rare Isotope Beams (FRIB) fragment separator dipole magnet which bends the beam by 30° and is located in a high radiation region that will not be easily accessible. Two of these magnets are needed to select the chosen isotope. There are a number of technical challenges to be addressed in the design of this magnet. The separator dipole is 2 m long and subtends a large angle. The magnet should keep a constant transverse field profile along its beam reference path. Winding coils with a curved inner segment is difficult as the conductor will tend to unwind during the process. In the Phase I project two approaches to winding the conductor were examined. The first was to wind the coils with curved sections on the inner and outer segments with the inner segment wound with negative curvature. The alternate approach was to use a straight segment on the inner segment to avoid negative curvature. In Phase I coils with a limited number of turns were successfully wound and tested at 77 K for both coil configurations. The Phase II program concentrated on the design, coil winding procedures, structural analysis, prototyping and testing of an HTS curved dipole coil at 40 K with a heat load representative of the radiation environment. One of the key criteria of the design of this magnet is to avoid the use of organic materials that would degrade rapidly in radiation. The Lorentz forces expected from the coils interacting with the magnetic field are large and in order minimize the deformation of the coils, mechanical support must be provided. Since the support structure cannot be made of organic materials with minimal thermal conductivity, an optimization was explored comparing the amount of coil deformation that can be tolerated and the amount of heat leakage that can be endured. A test coil containing 500 m of HTS was constructed to be tested at the 40 K operating temperature. The anticipated heat load was simulated with heater strips to demonstrate that the heat could be removed and that the coil can operate in a stable state. The FRIB project has decided that using HTS coils for this magnet was too risky considering their time and funding constraints and has opted for a more conservative approach with conventional coils. As an outcome of this STTR project, it is likely that HTS coils operating at higher temperatures will have beneficial applications for future accelerator projects.

40 K↗

Torus CLAS12-Superconducting Magnet Quench Analysis

The JLAB Torus magnet system consists of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration. These coils are wound with SSC-36 Nb-Ti superconductor and have the peak magnetic field of 3.6 T. The first coil manufacturing based on the JLAB design began at FNAL. The large magnet system dimensions (8 m diameter and 14 MJ of stored energy) dictate the need for quench protection. Each coil is placed in an aluminum case mounted inside a cryostat and cooled by 4.6 K supercritical helium gas flowing through a copper tube attached to the coil ID. The large coil dimensions and small cryostat thickness drove the design to challenging technical solutions, suggesting that Lorentz forces due to transport currents and eddy currents during quench and various failure scenarios are analyzed. The paper covers the magnet system quench analysis using the OPERA3d Quench code.

Kashikhin, V S↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗

Electromagnetic propulsion system

An electromagnetic propulsion system comprises a plurality of stator coils wound about a first axis, a plurality of support structures, a coupler that surrounds a portion of the stator coils, and a plurality of rotor coils wound about an axis that is parallel to the first axis. The stator coils are configured to receive electric current to induce a first magnetic field. The support structures support the stator coils. The coupler includes a notch oriented so that one of the support structures can pass through the notch when the coupler moves along the stator coils. The rotor coils are attached to the coupler and are configured to receive electric current to induce a magnetic field that interacts with the first magnetic field so that a magnetic force is applied to the rotor coils, thereby propelling the coupler and the rotor coils along the stator coils.

Hartman, Seth↗