Search NASA⌕ Search

SEARCH · Search NASA

Results for “MISR (Multi-angle Imaging SpectroRadiometer)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

222 records · Page 13

Moderate resolution imaging spectroradiometer (MODIS) and observations of the land surface

The moderate resolution imaging spectroradiometer (MODIS) is a NASA facility instrument that is being designed for flight on the Earth Observing System (EOS) series of missions. It is designed to measure biophysical states and dynamics of the land, atmosphere, and ocean. Plans are required for use of other instruments that will be accompanying MODIS on the EOS missions, such as the High-Resolution Imaging Spectrometer (HIRIS) and the Multi-angle Imaging Spectro-Radiometer (MISR). The HIRIS instrument, a spectrometer operating in the visible to shortwave infrared parts of the spectrum, would be employed in combination with the MODIS to understand the impact of sampling the spectrum and the effects of land cover mixtures within the MODIS pixel. The MISR will help in understanding the effects of anisotropy in reflected solar radiation. Both instruments will work in combination with MODIS to better quantify the effects of the atmosphere on observations of surface properties.

Salomonson, V. V.↗

The application of support vector machines to analysis of global satellite data sets from MlSR

The Multi-angle Imaging Spectro Radiometer (MISR) is one of a suite of five instruments onboard NASA's Terra EOS satellite, launched in December 1999. Typical satellite imagers view the earth from a single direction, but MISR's cameras image the earth simultaneously from nine different directions in four spectral bands. In this way, MISR provides unique multiangle information about solar radiation scattered from clouds, aerosols and other terrestrial surfaces. One of the primary goals of the MISR mission is to improve our understanding of how clouds and aerosols affect the earth's global energy balance.

support vector machines↗

Dust aerosol retrieval results from MISR (multi-angle imaging spectro-radiometer)

Satellite measurements provide important tools for understanding the effect of mineral dust aerosols on past and present climate and climate predictions. Multi-angle instruments such as Multi-angle Imaging Spectro- Radiometer (MISR) provide independent constraints on aerosol properties based on their sensitivity to the shape of aerosol scattering phase functions. The current MISR operational retrieval algorithm (version 16 and higher) was modified by incorporating new non-spherical dust models that account for naturally occurring dust shapes and compositions. We present selected examples of MISR version 16 retrievals over AERONET sunphotometer land and ocean sites during the passage of dust fronts. Our analysis shows that during such events MISR retrieves Angstrom exponents characteristic of large particles, having little spectral variation in extinction over the MISR wavelength range (442, 550, 672 and 866 nm channels), as expected. The retrieved fraction of non-spherical particles is also very high. This quantity is not retrieved by satellite instruments having only nadir-viewing cameras. Our comparison of current (version 16) MISR-retrieved aerosol optical thickness (AOT) with AERONET instantaneous AOT shows better coverage and stronger correlations than when making identical comparisons with previous AOT retrievals (version 15). The MISR algorithm successful mixtures include a non-spherical dust component with high frequency in retrievals over dark water and slightly lower frequency over land. Selection frequencies of non-spherical dust models also decrease in dusty regions affected by pollution.

Multiangle Imaging Spectroradiometer (MISR)↗

MISR CMVs and Multiangular Views of Tropical Cyclone Inner-Core Dynamics

Multi-camera stereo imaging of cloud features from the MISR (Multiangle Imaging SpectroRadiometer) instrument on NASA's Terra satellite provides accurate and precise measurements of cloud top heights (CTH) and cloud motion vector (CMV) winds. MISR observes each cloudy scene from nine viewing angles (Nadir, +/-26(sup o), +/-46(sup o), +/-60(sup o), +/-70(sup o)) with approximatel 275-m pixel resolution. This paper provides an update on MISR CMV and CTH algorithm improvements, and explores a high-resolution retrieval of tangential winds inside the eyewall of tropical cyclones (TC). The MISR CMV and CTH retrievals from the updated algorithm are significantly improved in terms of spatial coverage and systematic errors. A new product, the 1.1-km cross-track wind, provides high accuracy and precision in measuring convective outflows. Preliminary results obtained from the 1.1-km tangential wind retrieval inside the TC eyewall show that the inner-core rotation is often faster near the eyewall, and this faster rotation appears to be related linearly to cyclone intensity.

hurricanes↗

Analysis of Fine-Mode Aerosol Retrieval Capabilities by Different Passive Remote Sensing Instrument Designs

Remote sensing of aerosol optical properties is difficult, but multi-angle, multi-spectral, polarimetric instruments have the potential to retrieve sufficient information about aerosols that they can be used to improve global climate models. However, the complexity of these instruments means that it is difficult to intuitively understand the relationship between instrument design and retrieval success. We apply a Bayesian statistical technique that relates instrument characteristics to the information contained in an observation. Using realistic simulations of fine size mode dominated spherical aerosols, we investigate three instrument designs. Two of these represent instruments currently in orbit: the Multiangle Imaging SpectroRadiometer (MISR) and the POLarization and Directionality of the Earths Reflectances (POLDER). The third is the Aerosol Polarimetry Sensor (APS), which failed to reach orbit during recent launch, but represents a viable design for future instruments. The results show fundamental differences between the three, and offer suggestions for future instrument design and the optimal retrieval strategy for current instruments. Generally, our results agree with previous validation efforts of POLDER and airborne prototypes of APS, but show that the MISR aerosol optical thickness uncertainty characterization is possibly underestimated.

Knobelspiesse, Kirk↗