Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Continuous magnetic flux pump

A method and means for altering the intensity of a magnetic field by transposing flux from one location to the location desired fro the magnetic field are examined. The device described includes a pair of communicating cavities formed in a block of superconducting material, is dimensioned to be insertable into one of the cavities and to substantially fill the cavity. Magnetic flux is first trapped in the cavities by establishing a magnetic field while the superconducting material is above the critical temperature at which it goes superconducting. Thereafter, the temperature of the material is reduced below the critical value, and then the exciting magnetic field may be removed. By varying the ratios of the areas of the two cavities, it is possible to produce a field having much greater flux density in the second, smaller cavity, into which the flux transposed.

Hildebrandt, A. F.↗

Magnetic-Field-Tunable Superconducting Rectifier

Superconducting electronic components have been developed that provide current rectification that is tunable by design and with an externally applied magnetic field to the circuit component. The superconducting material used in the device is relatively free of pinning sites with its critical current determined by a geometric energy barrier to vortex entry. The ability of the vortices to move freely inside the device means this innovation does not suffer from magnetic hysteresis effects changing the state of the superconductor. The invention requires a superconductor geometry with opposite edges along the direction of current flow. In order for the critical current asymmetry effect to occur, the device must have different vortex nucleation conditions at opposite edges. Alternative embodiments producing the necessary conditions include edges being held at different temperatures, at different local magnetic fields, with different current-injection geometries, and structural differences between opposite edges causing changes in the size of the geometric energy barrier. An edge fabricated with indentations of the order of the coherence length will significantly lower the geometric energy barrier to vortex entry, meaning vortex passage across the device at lower currents causing resistive dissipation. The existing prototype is a two-terminal device consisting of a thin-film su - perconducting strip operating at a temperature below its superconducting transition temperature (Tc). Opposite ends of the strip are connected to electrical leads made of a higher Tc superconductor. The thin-film lithographic process provides an easy means to alter edge-structures, current-injection geo - metries, and magnetic-field conditions at the edges. The edge-field conditions can be altered by using local field(s) generated from dedicated higher Tc leads or even using the device s own higher Tc superconducting leads.

Sadleir, John E.↗

The Annular Suspension and Pointing (ASP) system for space experiments and predicted pointing accuracies

An annular suspension and pointing system consisting of pointing assemblies for coarse and vernier pointing is described. The first assembly is attached to a carrier spacecraft (e.g., the space shuttle) and consists of an azimuth gimbal and an elevation gimbal which provide 'coarse' pointing. The second or vernier pointing assembly is made up of magnetic actuators of suspension and fine pointing, roll motor segments, and an instrument or experiment mounting plate around which is attached a continuous annular rim similar to that used in the annular momentum control device. The rim provides appropriate magnetic circuits for the actuators and the roll motor segments for any instrument roll position. The results of a study to determine the pointing accuracy of the system in the presence of crew motion disturbances are presented. Typical 3 sigma worst-case errors are found to be of the order of 0.001 arc-second.

Anderson, W. W.↗

An inertial fusion propulsion scheme for solar system exploration

The paper analyzes a novel fusion scheme that combines the favorable aspects of both inertial and magnetic confinement approaches as a propulsion device for potential application in solar system exploration. An appropriate set of equations for the plasma dynamics and the magnetic nozzle is used to assess the system's propulsive capability by applying the results to a round trip mission to Mars. It is found that such a device would allow a massive vehicle to make the journey in less than five months. It is shown that catalyzed deuterium-deuterium fuel results in a somewhat poorer propulsion performance than deuterium-tritium though at a significantly lower neutron production. The velocity increment generated by this system and the corresponding trip time are in excellent agreement with the predictions of Irving and Blum (1959).

Kammash, Terry↗

Digital magnetic temperature transducer.

A new digital magnetic temperature transducer is reported. The device utilizes the discontinuous behavior of the initial permeability with temperature at the Curie temperature of some magnetic materials. Since the Curie temperature is determined by the chemical and crystallographic composition of the particular material only, the transducer requires no calibration and has extremely high stability and reproducibility with time. The output of the transducer is inherently digital and, therefore, is directly compatible with the digital information processing and control without A/D conversion. The temperature-sensing portion of the transducer consists only of magnetic cores and wire and, therefore, has extremely high reliability, is shock and radiation insensitive, small, and virtually indestructible.

Tchernev, D. I.↗

Magneto-optic garnet and liquid crystal optical switches

Magnetic stripe domain and liquid crystal devices are being developed and evaluated as fiber optic switches that can be utilized for nonblocking type nxm optical matrix switches in networking and optical processing. Liquid crystal switches are characterized by very low insertion loss and crosstalk, while stripe domain switches commutate in less than one microsecond. Both switches operate on multimode, randomly polarized fiber light with potentially large values for (n,m). The applications of these magnetic stripe domain and liquid crystal devices are discussed.

Krawczak, J. A.↗

On a photon-counting array using the Fairchild CCD-201

The evaluation of certain performance parameters of the Fairchild CCD 201 and the proposed method of operation of an electron bombarded charge coupled device are described. Work in progress on the evaluation of the parameters relevant to remote, low noise operation is reported. These tests have been conducted using light input. The video data from the CCD are amplified, digitized, stored in a minicomputer memory, and then recorded on magnetic tape for analyzing. The device will be used in an array of sensors in the aperture plane of a telescope to discriminate between photoelectron events, and in the focal plane operating at single photoelectron sensitivity at a minimum of blooming and lag.

Currie, D. G.↗

Device for measuring electric fields

Measurement of low-intensity electric fields in space and in presence of weak magnetic fields is accomplished by utilizing a device which permits determination of the extent a beam of cesium ions is deflected by an electric field.

Levine, S. H.↗

Phase-Controlled Magnetic Mirror for Wavefront Correction

Typically, light interacts with matter via the electric field and interaction with weakly bound electrons. In a magnetic mirror, a patterned nanowire is fabricated over a metallic layer with a dielectric layer in between. Oscillation of the electrons in the nanowires in response to the magnetic field of incident photons causes a re-emission of photons and operation as a "magnetic mirror." By controlling the index of refraction in the dielectric layer using a local applied voltage, the phase of the emitted radiation can be controlled. This allows electrical modification of the reflected wavefront, resulting in a deformable mirror that can be used for wavefront control. Certain applications require wavefront quality in the few-nanometer regime, which is a major challenge for optical fabrication and alignment of mirrors or lenses. The use of a deformable magnetic mirror allows for a device with no moving parts that can modify the phase of incident light over many spatial scales, potentially with higher resolution than current approaches. Current deformable mirrors modify the incident wavefront by using nano-actuation of a substrate to physically bend the mirror to a desired shape. The purpose of the innovation is to modify the incident wavefront for the purpose of correction of fabrication and alignment-induced wavefront errors at the system level. The advanced degree of precision required for some applications such as gravity wave detection (LISA - Laser Interferometer Space Antenna) or planet finding (FKSI - Fourier-Kelvin Stellar Interferometer) requires wavefront control at the limits of the current state of the art. All the steps required to fabricate a magnetic mirror have been demonstrated. The modification is to apply a bias voltage to the dielectric layer so as to change the index of refraction and modify the phase of the reflected radiation. Light is reflected off the device and collected by a phase-sensing interferometer. The interferometer determines the initial wavefront of the device and fore optics. A wavefront correction is calculated, and voltage profile for each nanowire strip is determined. The voltage is applied, modifying the local index of refraction of the dielectric under the nanowire strip. This modifies the phase of the reflected light to allow wavefront correction.

Hagopian, John↗

Passive chevron replicator

There is described a passive replicator device to be used in magnetic bubble domain systems. The replicator is passive, i.e., does not require an active element such as a current source or the like, and both propagates and replicates bubble domains. In a preferred embodiment, the replicator uses chevron type elements arranged in an appropriate pattern so as to interact with a pair of propagation paths wherein bubble domains are propagated. A bubble in one propagation path is routinely transferred therealong and, concurrently, replicated by the instant device into another propagation path. A plurality of elements arranged in juxtaposition to the chevrons assists in controlling the propagation of the bubbles through the respective propagation paths and, at the appropriate time, provides a cutting action wherein a bubble which is elongated between the chevrons of the two propagation paths is split into two separate bubbles.

Oeffinger, Thomas R.↗

Magnetic-Field-Assisted Terahertz Quantum Cascade Laser Operating up to 225 K

Advances in semiconductor bandgap engineering have resulted in the recent development of the terahertz quantum cascade laser1. These compact optoelectronic devices now operate in the frequency range 1.2-5 THz, although cryogenic cooling is still required2.3. Further progress towards the realization of devices operating at higher temperatures and emitting at longer wavelengths (sub-terahertz quantum cascade lasers) is difficult because it requires maintaining a population inversion between closely spaced electronic sub-bands (1 THz approx. equals 4 meV). Here, we demonstrate a magnetic-field-assisted quantum cascade laser based on the resonant-phonon design. By applying appropriate electrical bias and strong magnetic fields above 16 T, it is possible to achieve laser emission from a single device over a wide range of frequencies (0.68-3.33 THz). Owing to the suppression of inter-landau-level non-radiative scattering, the device shows magnetic field assisted laser action at 1 THz at temperatures up to 215 K, and 3 THz lasing up to 225 K.

Wade, A.↗

Investigation of storage system designs and techniques for optimizing energy conservation in integrated utility systems. Volume 3: (Assessment of technical and cost characteristics of candidate IUS energy storage devices)

Six energy storage technologies (inertial, superconducting magnetic, electrochemical, chemical, compressed air, and thermal) were assessed and evaluated for specific applicability to the IUS. To provide a perspective for the individual storage technologies, a brief outline of the general nature of energy storage and its significance to the user is presented.

Source record↗

Compact Translating-Head Magnetic Memories

Stationary magnetic media stores information at densities up to 6.5 Gb/cm(Sup 2). High-density memory devices combine features of advanced rotating-disk magnetic recording and playback systems with compact two-axis high-acceleration linear actuators. New devices weigh less, occupy less space, and consume less power than disk and tape recorders.

Katti, Romney R.↗

The 11th Aerospace Mechanisms Symposium

Mechanical devices and drives developed for aerospace applications are described. Satellite flywheels, magnetic bearings, a missile umbilical system, a cartridge firing device, and an oiler for satellite bearing lubrication are among the topics discussed.

Source record↗

Double-focusing mass spectrometer

Device uses lighter, easily alined, magnet assembly to provide field required to interact with ion beam. It has no separate duct; instead, evacuated duct is formed by pole pieces which support vacuum pump. Magnetic gap and magnet assembly are reduced from 4.64 to 2.54 mm and from 2.4 to 1.5 kg, respectively.

Giffin, C. E.↗

Three-Axis Superconducting Gravity Gradiometer

Gravity gradients measured even on accelerating platforms. Three-axis superconducting gravity gradiometer based on flux quantization and Meissner effect in superconductors and employs superconducting quantum interference device as amplifier. Incorporates several magnetically levitated proof masses. Gradiometer design integrates accelerometers for operation in differential mode. Principal use in commercial instruments for measurement of Earth-gravity gradients in geo-physical surveying and exploration for oil.

Paik, Ho Jung↗

Physical origin of the frequency shifts in cesium beam frequency standards: Related environmental sensitivity

When observed in a cesium beam frequency standard, the hyperfine transition frequency of the atoms differs slightly from the invariant transition frequency of the unperturbed atoms at rest. The various physical and technical origins of the frequency offsets are stated. They relate to fundamental physical effects, to the method of probing the atomic resonance and to the frequency control of the slaved oscillator. The variation of the frequency offsets under a change of the value of the internal operating characteristics is considered. The sensitivity to a change of the magnetic induction, the microwave power, and the temperature is given. A comparison is made of the sensitivity of cesium beam frequency standards of the commercially available type, making use of magnetic state selection, and of devices under study, in which the state preparation and detection is accomplished optically. The pathways between the external stimuli and the physical origin of the frequency offsets are specified.

Audoin, Claude↗