Composition and structure of Mars' upper atmosphere - Results from the neutral mass spectrometers on Viking 1 and 2

The upper atmospheric mass spectrometers flown on Viking 1 and 2 are described, and results obtained for the composition and structure of Mars' upper atmosphere are summarized. Carbon dioxide is the major constituent of the atmosphere at all heights below 180 km. The thermal structure of the upper atmosphere is complex and variable with average temperatures below 200 K for both Viking 1 and 2. The atmosphere is mixed to heights in excess of 120 km. The isotopic composition of carbon and oxygen in the Martian atmosphere is similar to that in the terrestrial atmosphere: N-15 is enriched in Mars' atmosphere by a factor of 1.62 + or - 0.16.

Nier, A. O.↗

Thermal ion temperatures from the retarding ion mass spectrometer on DE 1

Data from the retarding ion mass spectrometer (RIMS) on Dynamics Explorer 1 are analyzed by means of a thin sheath model to determine ion temperatures. A number of characteristic features of ion temperatures in and near the plasmasphere are presented. Typical H(+) temperatures in the plasmasphere are found to be 4000 K to 6000 K on the morningside and 2000 K to 4000 K on the eveningside, increasing with L throughout. In the plasma trough, typical temperatures observed are a few times 10,000 K. In the outer plasmasphere, multiple temperature components are frequently observed. H(+) and He(+) ions are found to be very close to thermal equilibrium with each other in all but perhaps the outer part of the plasmasphere. Within the plasmasphere, temperature profiles observed by DE 1/RIMS rarely show small-scale variation. During geomagnetically active times, high-altitude temperatures between L = 2 and 3 appear to be depressed over quiet time values, to the extent that they may be cooler than temperatures at low altitudes along approximately the same field line.

Comfort, R. H.↗

Neutral mass spectrometer measurements in the shuttle bay environment

A neutral mass spectrometer, flown as part of the Induced Environment Contamination Monitor (IECM), is briefly described. Results from STS-2, -3, -4, and Spacelab 1 are qualitatively summarized. The gases observed were, for the most part, those with molecular weights below 45 amu with sources attributable to instrument background, shuttle-induced environment, and the ambient atmosphere. The most abundant gases were H2O, N2, and He. Heavier gases consisted primarily of fluorocarbons.

Miller, E.↗

Miniature quadrupole mass spectrometer array

The present invention provides a minature quadrupole mass spectrometer array for the separation of ions, comprising a first pair of parallel, planar, nonmagnetic conducting rods each having an axis of symmetry, a second pair of planar, nonmagnetic conducting rods each having an axis of symmetry parallel to said first pair of rods and disposed such that a line perpendicular to each of said first axes of symmetry and a line perpendicular to each of said second axes of symmetry bisect each other and form a generally 90 degree angle. A nonconductive top positioning plate is positioned generally perpendicular to the first and second pairs of rods and has an aperture for ion entrance along an axis equidistant from each axis of symmetry of each of the parallel rods, a nonconductive bottom positioning plate is generally parallel to the top positioning plate and has an aperture for ion exit centered on an axis equidistant from each axis of symmetry of each of the parallel rods, means for maintaining a direct current voltage between the first and second pairs of rods, and means for applying a radio frequency voltage to the first and second pairs of rods.

Chutjian, Ara↗

Miniature quadrupole mass spectrometer array

The present invention provides a minature quadrupole mass spectrometer array for the separation of ions, comprising a first pair of parallel, planar, nonmagnetic conducting rods each having an axis of symmetry, a second pair of planar, nonmagnetic conducting rods each having an axis of symmetry parallel to said first pair of rods and disposed such that a line perpendicular to each of said first axes of symmetry and a line perpendicular to each of said second axes of symmetry bisect each other and form a generally 90 degree angle. A nonconductive top positioning plate is positioned generally perpendicular to the first and second pairs of rods and has an aperture for ion entrance along an axis equidistant from each axis of symmetry of each of the parallel rods, a nonconductive bottom positioning plate is generally parallel to the top positioning plate and has an aperture for ion exit centered on an axis equidistant from each axis of symmetry of each of the parallel rods, means for maintaining a direct current voltage between the first and second pairs of rods, and means for applying a radio frequency voltage to the first and second pairs of rods.

Chutjian, Ara↗

The Composition of Titan's Lower Atmosphere and Simple Surface Volatiles as Measured by the Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer Experiment

The Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer (GCMS) determined the composition of the Titan atmosphere from ~140km altitude to the surface. After landing, it returned composition data of gases evaporated from the surface. Height profiles of molecular nitrogen (N2), methane (CH4) and molecular hydrogen (H2) were determined. Traces were detected on the surface of evaporating methane, ethane (C2H6), acetylene (C2H2), cyanogen (C2N2) and carbon dioxide (CO2). The methane data showed evidence that methane precipitation occurred recently. The methane mole fraction was (1.48+/-0.09) x 10(exp -2) in the lower stratosphere (139.8 km to 75.5 km) and (5.65+/-0.18) x 10(exp -2) near the surface (6.7 km to the surface). The molecular hydrogen mole fraction was (1.01+/-0.16) x 10(exp -3) in the atmosphere and (9.90+/-0.17) x 10(exp -4) on the surface. Isotope ratios were 167.7+/-0.6 for N-14/N-15 in molecular nitrogen, 91.1+/-1.4 for C-12/C-13 in methane and (1.35+/-0.30) x 10(exp -4) for D/H in molecular hydrogen. The mole fractions of Ar-36 and radiogenic Ar-40 are (2.1+/-0.8) x 10(exp -7) and (3.39 +/-0.12) x 10(exp -5) respectively. Ne-22 has been tentatively identified at a mole fraction of (2.8+/-2.1) x 10(exp -7) Krypton and xenon were below the detection threshold of 1 x 10(exp -8) mole fraction. Science data were not retrieved from the gas chromatograph subsystem as the abundance of the organic trace gases in the atmosphere and on the ground did not reach the detection threshold. Results previously published from the GCMS experiment are superseded by this publication.

Niemann, H. B.↗

AE and DE mass spectrometer observations relevant to the shuttle glow

Recent work suggested that NO2 may be responsible for the observed continuum glow near surfaces of the space shuttle. The observations of atomic nitrogen (N) are reported at shuttle altitudes using mass spectrometers, giving special attention to the surface reactions of N relevant to the production of NO2 on spacecraft surfaces. Data from two semi-open sources mass spectrometers, the OSS instruments on the Atmosphere Explorer-C and -D satellites, and the closed source Neutral Atmospheric Composition Spectrometer (NACS) on the Dynamic Explorer-2 satellite are presented to show the similar behavior of NO in each case and the contrasting behavior of NO2. Although signals of NO and NO2 are highly dependent on surface temperature and surface composition, it appears that direct exposure of ion source surfaces to rammed gas is a necessary condition for the production of large amounts of NO2. Evidence that elevated surface temperatures can significantly reduce the production of NO2, likely by causing more rapid desorption of NO from these surfaces, is presented.

Engebretson, M. J.↗

Plasma Wakes from the Baffle Scanning Mechanism on a LEO Mass Spectrometer

The Modular Spectrometer for Atmosphere and Ionosphere Characterization (MoSAIC) is a Quadrupole Mass Spectrometer (QMS) which will fly on NASA's Geospace Dynamics Constellation (GDC) mission in low Earth orbit (LEO), providing measurements of neutral and ionized gas density, temperature, composition, and wind/drift. MoSAIC includes a Baffle Scanning Mechanism (BSM) which periodically sweeps in front of the QMS aperture, enabling determination of the ion temperature and cross-track velocity. Accurate knowledge of the plasma wake formed by the BSM is critical for accurate determination of these quantities. We conduct particle-in-cell (PIC) simulations modeling the interactions between the baffle and plasma across the full range of ion densities, temperatures, and flow speeds GDC is expected to encounter. We discuss the wake physics and present an empirical model which can be implemented in the MoSAIC data analysis process to determine the relevant ion quantities.

mass spectrometer↗

Comparative performance of double-focus and quadrupole mass spectrometers

Light-weight flight type double focus and quadruple mass spectrometer models were compared. Data cover size, weight, and power sensitivity required to achieve same resolution sensitivity at given mass number. Comparison was made using mathematical relationships. Analysis was confined to equal ion source area sensitivity variations not more than 40% over mass range.

Wilson, S. K.↗

The Retarding Ion Mass Spectrometer on Dynamics Explorer-A

The thermal component of the magnetospheric plasma plays a key role in magnetosphere-ionosphere coupling processes, acting as a strong influence on ionospheric structure at low altitudes and as a source and modifier of the hotter plasma population at high altitudes. The Retarding Ion Mass Spectrometer (RIMS) instrument on Dynamics Explorer-A is designed to measure this important thermal plasma component. Using a combination of retarding potential analysis and magnetic ion mass spectrometer techniques, the RIMS instrument will measure the bulk plasma parameters of ion density (0.1 to 1,000,000 ions/cu cm), temperature (0-45 eV), and bulk flow (greater than 0.5 km/sec) in the inner plasmasphere and ionosphere, and the specific ion pitch angle and energy spectral characteristics in the outer plasmasphere and plasma trough for a mass range of 1-32 amu. The energy and mass spectral step sequences, as well as the multiplexing of the resultant data, can be tailored to accomplish a variety of thermal ion measurements throughout the inner magnetosphere.

Chappell, C. R.↗

High sensitivity pulse-counting mass spectrometer system for noble gas analysis

A pulse-counting mass spectrometer is described which is comprised of a new ion source of cylindrical geometry, with exceptional optical properties (the Baur source), a dual focal plane externally adjustable collector slits, and a 17-stage Allen-type electron multiplier, all housed in a metal 21 cm radius, 90 deg magnetic sector flight tube. Mass discrimination of the instrument is less than 1 per mil per mass unit; the optical transmission is more than 90%; the source sensitivity (Faraday collection) is 4 ma/torr at 250 micron emission; and the abundance sensitivity is 30,000.

Hohenberg, C. M.↗

Gas densities near 230 km from orbital drag and mass spectrometer measurements - A comparison

Perigee density data near 230 km for the Aeros satellite are analyzed for more than 1000 orbits. A comparison method for such data was developed which is based on the observed rate of change of orbital period as compared with the orbital decay computed from mass-spectrometer data obtained at discrete positions along the orbit. In general, the method confirms the good agreement of the average ratio of in-situ and orbit-drag-inferred perigee densities. In the case of Aeros, absolute densities measured by the NATE mass spectrometer are confirmed.

Roemar, M.↗