Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗

Backaction-evading receivers with magnetomechanical and electromechanical sensors

Today's mechanical sensors are capable of detecting extremely weak perturbations while operating near the standard quantum limit. However, further improvements can be made in both sensitivity and bandwidth when we reduce the noise originating from the process of measurement itself—the quantum-mechanical backaction of measurement—and go below this ‘standard’ limit, possibly approaching the Heisenberg limit. One of the ways to eliminate this noise is by measuring a quantum nondemolition variable such as the momentum in a free-particle system. Here, we propose and characterize theoretical models for direct velocity measurement that utilize traditional electric and magnetic transducer designs to generate a signal while enabling this backaction evasion. We consider the general readout of this signal via electric or magnetic field sensing by creating toy models analogous to the standard optomechanical position-sensing problem, thereby facilitating the assessment of measurement-added noise. Using simple models that characterize a wide range of transducers, we find that the choice of readout scheme—voltage or current—for each mechanical detector configuration implies access to either the position or velocity of the mechanical subsystem. This in turn suggests a path forward for key fundamental physics experiments such as the direct detection of dark matter particles. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Towards optimal sensor placement for inverse problems in spaces of measures

The objective of this work is to quantify the reconstruction error in sparse inverse problems with measures and stochastic noise, motivated by optimal sensor placement. To be useful in this context, the error quantities must be explicit in the sensor configuration and robust with respect to the source, yet relatively easy to compute in practice, compared to a direct evaluation of the error by a large number of samples. In particular, we consider the identification of a measure consisting of an unknown linear combination of point sources from a finite number of measurements contaminated by Gaussian noise. The statistical framework for recovery relies on two main ingredients: first, a convex but non-smooth variational Tikhonov point estimator over the space of Radon measures and, second, a suitable mean-squared error based on its Hellinger–Kantorovich distance to the ground truth. To quantify the error, we employ a non-degenerate source condition as well as careful linearization arguments to derive a computable upper bound. This leads to asymptotically sharp error estimates in expectation that are explicit in the sensor configuration. Thus they can be used to estimate the expected reconstruction error for a given sensor configuration and guide the placement of sensors in sparse inverse problems.

97 MATHEMATICS AND COMPUTING↗

How Many Elements Matter?

Some studies of stars' multielement abundance distributions suggest at least 5–7 significant dimensions, but others show that many elemental abundances can be predicted to high accuracy from [Fe/H] and [Mg/Fe] (or [Fe/H] and age) alone. We show that both propositions can be, and are, simultaneously true. We adopt a machine-learning technique known as normalizing flow to reconstruct the probability distribution of Milky Way disk stars in the space of 15 elemental abundances measured by APOGEE. Conditioning on T eff and $\mathrm{log}\,g$ minimizes the differential systematics. After further conditioning on [Fe/H] and [Mg/Fe], the residual scatter for most abundances is σ [X/H] ≲ 0.02 dex, consistent with APOGEE's reported statistical uncertainties of ~0.01–0.015 dex and intrinsic scatter of 0.01–0.02 dex. Despite the small scatter, residual abundances display clear correlations between elements, which we show are too large to be explained by measurement uncertainties or by the finite sampling noise. We must condition on at least seven elements to reduce the correlations to a level consistent with the observational uncertainties. Our results demonstrate that cross-element correlations are a much more sensitive probe of a hidden structure than dispersion, and they can be measured precisely in a large sample even if the star-by-star measurement noise is comparable to the intrinsic scatter. We conclude that many elements have an independent story to tell, even for the mundane disk stars and elements produced by the core-collapse and Type Ia supernovae. The only way to learn these lessons is to measure the abundances directly, and not merely infer them.

79 ASTRONOMY AND ASTROPHYSICS↗

A beamline for ultrafast extreme ultraviolet magneto-optical spectroscopy in reflection near the shot noise limit

High harmonic generation (HHG) makes it possible to measure spin and charge dynamics in materials on femtosecond to attosecond timescales. However, the extreme nonlinear nature of the high harmonic process means that intensity fluctuations can limit measurement sensitivity. Here we present a noise-canceled, tabletop high harmonic beamline for time-resolved reflection mode spectroscopy of magnetic materials. We use a reference spectrometer to independently normalize the intensity fluctuations of each harmonic order and eliminate long term drift, allowing us to make spectroscopic measurements near the shot noise limit. Here, these improvements allow us to significantly reduce the integration time required for high signal-to-noise (SNR) measurements of element-specific spin dynamics. Looking forward, improvements in the HHG flux, optical coatings, and grating design can further reduce the acquisition time for high SNR measurements by 1–2 orders of magnitude, enabling dramatically improved sensitivity to spin, charge, and phonon dynamics in magnetic materials.

47 OTHER INSTRUMENTATION↗

Noise-aware optimization in nominally identical manufacturing and measuring systems for high-throughput parallel workflows

Device-to-device variability in experimental noise critically impacts reproducibility, especially in automated, high-throughput systems like additive manufacturing farms. While manageable in small labs, such variability can escalate into serious risks at larger scales, such as architectural 3D printing, where noise may cause structural or economic failures. This contribution presents a noise-aware decision-making algorithm that quantifies and models device-specific noise profiles to manage variability adaptively. It uses distributional analysis and pairwise divergence metrics with clustering to choose between single-device and robust multi-device Bayesian optimization strategies. Unlike conventional methods that assume homogeneous devices or enforce generic robustness, the proposed framework explicitly determines whether shared optimization across devices is appropriate based on the degree of inter-device noise heterogeneity. This enables improved performance, reproducibility, and efficiency. An experimental case study involving three nominally identical 3D printers (same brand, model, and close serial numbers) demonstrates reduced redundancy, lower resource usage, and improved reliability, along with improved convergence stability and solution quality through the selection of the appropriate optimization strategy based on the degree of inter-device noise heterogeneity. Overall, this framework establishes a general approach for precision- and resource-aware optimization in scalable, automated experimental platforms, demonstrated here on a representative multi-device 3D printing case study.

Schenk, Christina↗

Characterization of Noise in CMOS Ring Oscillators at Cryogenic Temperatures

Allan deviation provides a means to characterize the time-dependence of noise in oscillators and potentially identify the source characteristics. Measurements on a 130 nm, 7-stage ring oscillator show that the Allan deviation declines from 300 K to 150 K as expected, but surprisingly increases from 150 K to 11 K. At low temperatures, the measured Allan deviation can be well fit using a few random telegraph noise (RTN) sources over the range of a few kilohertz to a few gigahertz. Further, the RTN characteristics evolve to reveal an enhanced role in low-frequency noise at lower temperatures.

47 OTHER INSTRUMENTATION↗

Testing the ΛCDM Cosmological Model with Forthcoming Measurements of the Cosmic Microwave Background with SPT-3G

We forecast constraints on cosmological parameters enabled by three surveys conducted with SPT-3G, the third-generation camera on the South Pole Telescope. The surveys cover separate regions of 1500, 2650, and 6000 deg$^{2}$ to different depths, in total observing 25% of the sky. These regions will be measured to white noise levels of roughly 2.5, 9, and 12μK-armin, respectively, in cosmic microwave background (CMB) temperature units at 150 GHz by the end of 2024. The survey also includes measurements at 95 and 220 GHz, which have noise levels a factor of ∼1.2 and 3.5 times higher than 150 GHz, respectively, with each band having a polarization noise level ∼2times higher than the temperature noise. We use a novel approach to obtain the covariance matrices for jointly and optimally estimated gravitational lensing potential band powers and unlensed CMB temperature and polarization band powers. We demonstrate the ability to test the ΛCDM model via the consistency of cosmological parameters constrained independently from SPT-3G and Planck data, and consider the improvement in constraints on ΛCDM extension parameters from a joint analysis of SPT-3G and Planck data. The ΛCDM cosmological parameters are typically constrained with uncertainties up to ∼2 times smaller with SPT-3G data, compared to Planck, with the two data sets measuring significantly different angular scales and polarization levels, providing additional tests of the standard cosmological model.

79 ASTRONOMY AND ASTROPHYSICS↗

Universal monitored dynamics in multimode bosonic systems

We propose a route to study monitored many-body dynamics in multimode bosonic systems using circuit quantum electrodynamics. In this experimental setting, we construct several bosonic models comprising brickwork circuits built from beam-splitter gates, local parity measurements, and optional on-site Hubbard interactions, and diagnose their monitored dynamics via ancilla purification and a learnability-based probe. Under parity measurements, generic gate sets exhibit behavior that is largely consistent with a conventional measurement-induced phase transition, while a special class of beam-splitter circuits shows an apparent critical-like high-measurement regime in which purification times scale linearly with system size. We show that for realistic noise, gate, and measurement rates, these signatures are observable with near-term circuit QED hardware.

Patel, Shivam [Rutgers U., Piscataway]↗

Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G

SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150-mm-diameter detector wafers, containing a total of similar to 16,000transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-laboratory characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.

Al-Mn↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shot noise sets the limit of quantification in electrochemical measurements

Detection of single molecules, particles, and rapid redox events is a challenge of electrochemical investigations and requires either an amplification strategy or significant averaging for the electrochemical current to exceed the noise level. We consider the minimum number of electrons required to reach the limit of quantification in these electrochemical measurements. A survey of the literature indicates that the state-of-the-art limit in current detection for different types of measurements (e.g. voltammetry, single-molecule redox cycling, ion channel recordings of single molecules, metal nanoparticle collision, and phase nucleation) is independent of the nature of the measurement and increases linearly with reciprocal response time, Δt -1 , over ~5 orders of magnitude (from ~10 to ~10 6 s -1 ). This paper demonstrates that the practical limit of quantification requires cumulative measurement of ~2100 electrons during Δt and is determined by statistics of counting electrons, that is, the shot noise in the current.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Infrasound Wind Noise Reduction Systems for Use in Temporary Deployments

Infrasound, or low frequency sound 20 Hz, is produced by a variety of natural and anthropogenic sources. Wind also generates signals within this frequency band and serves as a persistent source of infrasonic noise. Infrasound sensors measure pressure fluctuations, which scale with the ambient density and velocity fluctuations of ground winds. Here we compare four different wind noise reduction systems, or "filters", and make recommendations for their use in temporary infrasound deployments. Our results show that there are two filters that are especially effective at reducing wind noise: (1) a Hyperion high frequency (HF) shroud with a 1 m diameter metal mesh dome placed on top and (2) a Hyperion Four Port Garden Hose shroud with 4 Miracle-Gro Soaker System garden hoses. We also find that placing a 5-gallon bucket over the HF wind shroud should not be done as it provides a negligible decrease in noise up to ~ 1 Hz and then an increase in noise. We conclude that it is up to the researcher to determine which of the other filters is best for their needs based on location and expense. We anticipate this study will be used as a resource for future deployments when a wind noise reduction method is necessary but only needed for a limited time period.

58 GEOSCIENCES↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Piezoelectric property of PZT nanofibers characterized by resonant piezo-force microscopy

Nano-piezoelectric materials have drawn tremendous research interest. However, characterization of their piezoelectric properties, especially measuring the piezoelectric strain coefficients, remains a challenge. Normally, researchers use an AFM-based method to directly measure nano-materials’ piezoelectric strain coefficients. But, the extremely small piezoelectric deformation, the influence from the parasitic electrostatic force, and the environmental noise make the measurement results questionable. In this paper, a resonant piezo-force microscopy method was used to accurately measure the piezoelectric deformation from 1D piezoelectric nanofibers. During the experiment, the AFM tip was brought into contact with the piezoelectric sample and set to work at close to its first resonant frequency. A lock-in amplifier was used to pick up the sample’s deformation signal at the testing frequency. By using this technique, the piezoelectric strain constant d 33 of the Lead Zirconate Titanate (PZT) nanofiber with a diameter of 76 nm was measured. The result showed that d 33 of this PZT nanofiber was around 387 pm/V. Meanwhile, by tracking the piezoelectric deformation phase image, domain structures inside PZT nanofibers were identified.

36 MATERIALS SCIENCE↗

Low two-level-system noise in hydrogenated amorphous silicon

At sub-Kelvin temperatures, two-level systems (TLSs) present in amorphous dielectrics source a permittivity noise, degrading the performance of a wide range of devices using superconductive resonators such as qubits or kinetic inductance detectors. We report here on measurements of TLS noise in hydrogenated amorphous silicon (a-Si:H) films deposited by plasma-enhanced chemical vapor deposition in superconductive lumped element resonators using parallel-plate capacitors. In conclusion, the TLS noise results presented in this article for two recipes of a-Si:H improve on the best results achieved in the literature by a factor >5 for a-Si:H and other amorphous dielectrics and are comparable to those observed for resonators deposited on crystalline dielectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗