Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Nanomechanical testing of freestanding polymer films: in situ tensile testing and Tg measurement

Abstract A method for small-scale testing and imaging of freestanding, microtomed polymer films using a push-to-pull device is presented. Central to this method was the development of a sample preparation technique which utilized solvents at cryogenic temperatures to transfer and deposit delicate thin films onto the microfabricated push-to-pull devices. The preparation of focused ion beam (FIB)-milled tensile specimens enabled quantitative in situ TEM tensile testing, but artifacts associated with ion and electron beam irradiation motivated the development of a FIB-free specimen preparation method. The FIB-free method was enabled by the design and fabrication of oversized strain-locking push-to-pull devices. An adaptation for push-to-pull devices to be compatible with an instrumented nanoindenter expanded the testing capabilities to include in situ heating. These innovations provided quantitative mechanical testing, postmortem TEM imaging, and the ability to measure the glass transition temperature, via dynamic mechanical analysis, of freestanding polymer films. Results for each of these mentioned characterization methods are presented and discussed in terms of polymer nanomechanics. Graphic Abstract

36 MATERIALS SCIENCE↗

Satellite Metallicity Enhancement I: Suppressed Star Formation, Stellar Mass Loss, and Enriched Inflow of DESI and EAGLE Galaxies around Massive Clusters

Environmental effects are a primary driver of elevated gas-phase metallicities in galaxies around massive clusters, but the underlying physical mechanisms for this satellite metallicity enhancement (SME) are still unclear. Using the Dark Energy Spectroscopic Instrument (DESI) Data Release 1, we present the first measurement of the average SME as a function of projected cluster-centric distance. The resulting profile reveals three distinct regimes: a steep decline from the cluster center, a plateau near the cluster boundary, and an extended downturn across several cluster radii. Remarkably, the complex shape and amplitude of this observed SME profile are successfully reproduced in the EAGLE cosmological simulation. Drawing insights from EAGLE, we develop a novel satellite chemical evolution model to decompose the observed SME into physical contributions from suppressed star formation, stellar mass loss, and enriched gas inflow. Our analysis shows that continuous accretion of enriched intracluster medium dominates the SME plateau within the cluster virial radius, while mass loss and quenching jointly drive the rapid metallicity decline in the cluster core. Our method disentangles the impacts of three environmental processes on galactic chemical enrichment in the cosmic web, providing a powerful framework for understanding cluster galaxy evolution with current and future spectroscopic surveys.

Lin, Yuanye [Shanghai Jiao Tong U.; Shanghai Jiaot↗

Characterization of Intrinsic Fiber Optic Temperature Sensors by In-core and Furnace Testing

Increased research and development in nuclear technology has raised the demand for novel sensors and instrumentation to meet data objectives, and survive in different conditions and environments, beyond conventional light water reactor (LWR) environments. Expediting the deployment of advanced nuclear technologies by developing, demonstrating, and qualifying advanced reactor fuel forms necessitates a deeper understanding of how irradiation affects fuels and materials' performance. To achieve a more comprehensive understanding of fuels and materials performance, researchers require more specialized experiments and measurements. The demand for innovative sensors to support nuclear fuel development arises from the complexity of materials' behavior under irradiation and the challenges of deploying instrumentation in Material Test Reactors (MTRs) for irradiation tests. Additionally, measurements of material properties require integrated measurement systems to characterize thermal properties, mechanical properties, chemistry, and microstructure [1]. Among the potential measurement techniques, optical fiber-based sensors have been identified as potential sensors to measure different physical phenomena such as temperature, strain, pressure, and fluid level. Optical fiber sensors have the capability to provide multi-sensing and multiplexing instrumentation, allowing the measurement of different physical parameters within a single sensor configuration, and transmitting data collected at multiple locations through a single fiber. They offer immunity to electromagnetic interference, electrical passivity, compatibility with various sensing methodologies, and cost-effectiveness. Beyond their widespread use in telecommunications, silica fiber-based instruments are utilized in industrial applications, even at temperatures reaching 300?400°C, such as distributed temperature sensing in oil and gas recovery. The Department of Energy (DOE) is interested in using fiber optics to support fuel cycle development [2]. Fiber optics are an excellent candidate for harsh environment sensing, including sensing at very high temperatures (1900oC for sapphire optical fibers). Distributed fiber optic sensing has been deployed in other harsh environments like coal gasification plants [3]. Distributed strain sensing, which operates similarly to distributed temperature sensing, has been deployed to monitor underground mines and fibers have been imbedded in soil to monitor sink-hole development [4][5]. The application of fiber optic sensors to advanced reactor development is a promising area of research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Strain Gauge Coatings on Water Intrusion in Submerged Composite Coupon Testing

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand their combined effects, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Strain measurements are critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions is not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure (SGF), strains, and SGF modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The coatings did not have significant effects on composite fatigue life or strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Fabrication and Testing of Two Passively Actuated Creep-Fatigue Surveillance Test Articles

This report describes the fabrication, testing, and analysis of two families of passively-actuated creep-fatigue test articles. These test articles induce cyclic mechanical load in a test section actuated solely through a mismatch in the thermal expansion coefficient of two materials and driven by a change in the specimen temperature. Test articles of this type could provide material degradation data for a materials surveillance program in future operating molten salt reactors, where variations in the reactor temperature caused by normal or upset cycles would provide the temperature change in the sample. The purpose of the current experimental campaign is to demonstrate the feasibility of fabricating realistically-sized test articles, test the articles under repeated thermal cycling to assess their robustness, particularly the reliability of the bimetallic welds, and collect strain data from instrumented samples to validate the methods used to size the test articles to match key features of the mechanical response of operating reactor components. The thermal cycling tests are ongoing but the test data to date suggests the current test article design is viable, robust, and can be successfully designed to match a target mechanical response. Finally, the report describes preliminary work on welding refractory alloys to 316H stainless steel. Replacing the test article driver material, currently Alloy 617, with a refractory would increase the coefficient of thermal expansion mismatch and support further miniaturization of the test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Low cost and massively parallel force spectroscopy with fluid loading on a chip

Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.

42 ENGINEERING↗

Tipiracil binds to uridine site and inhibits Nsp15 endoribonuclease NendoU from SARS-CoV-2

SARS-CoV-2 Nsp15 is a uridine-specific endoribonuclease with C-terminal catalytic domain belonging to the EndoU family that is highly conserved in coronaviruses. As endoribonuclease activity seems to be responsible for the interference with the innate immune response, Nsp15 emerges as an attractive target for therapeutic intervention. Here we report the first structures with bound nucleotides and show how the enzyme specifically recognizes uridine moiety. In addition to a uridine site we present evidence for a second base binding site that can accommodate any base. The structure with a transition state analog, uridine vanadate, confirms interactions key to catalytic mechanisms. In the presence of manganese ions, the enzyme cleaves unpaired RNAs. This acquired knowledge was instrumental in identifying Tipiracil, an FDA approved drug that is used in the treatment of colorectal cancer, as a potential anti-COVID-19 drug. Using crystallography, biochemical, and whole-cell assays, we demonstrate that Tipiracil inhibits SARS-CoV-2 Nsp15 by interacting with the uridine binding pocket in the enzyme’s active site. Our findings provide new insights for the development of uracil scaffold-based drugs.

59 BASIC BIOLOGICAL SCIENCES↗

High efficiency radio frequency antennas for amplifier free quantum sensing applications

Radio frequency (RF) signals are frequently used in emerging quantum applications due to their spin state manipulation capability. Efficient coupling of RF signals into a particular quantum system requires the utilization of carefully designed and fabricated antennas. Nitrogen vacancy (NV) defects in diamond are commonly utilized platforms in quantum sensing experiments with the optically detected magnetic resonance (ODMR) method, where an RF antenna is an essential element. We report on the design and fabrication of high efficiency coplanar RF antennas for quantum sensing applications. Single and double ring coplanar RF antennas were designed with -37 dB experimental return loss at 2.87 GHz, the zero-field splitting frequency of the negatively charged NV defect in diamond. The efficiency of both antennas was demonstrated in magnetic field sensing experiments with NV color centers in diamond. In conclusion, an RF amplifier was not needed, and the 0 dB output of a standard RF signal generator was adequate to run the ODMR experiments due to the high efficiency of the RF antennas.

47 OTHER INSTRUMENTATION↗

Dynamics of iodine geminate recombination in supercritical xenon solvent: Caging effect

Understanding the dynamics of chemical reactions in solutions is vital, as their rates and kinetics are significantly affected by the solvent environment. Supercritical solvents offer extensive applications in chemical reactions by enabling the manipulation of the solution environment. Here, in this study, we investigate the geminate recombination of iodine in a supercritical xenon solvent by using ReaxFF-based molecular dynamics simulations. Our findings reveal that the highest iodine recombination rate occurs near supercritical conditions, while lower-pressure conditions lead to reduced collision rates and unstable recombination, and higher-pressure conditions hinder iodine diffusion, resulting in a lower recombination rate. Our analysis shows that the xenon local density at the time of recombination is at least 2.5 times higher than the global density, confirming the presence of xenon clusters surrounding the Iodine atoms. This observation is further supported by coordination number analysis, which confirms an elevated xenon local density during recombination. In addition, the correlation between the total energy of xenon atoms within a cluster and recombined iodine atoms underscores the kinetic energy transfer process, validating the occurrence of geminate recombination. The excess kinetic energy from the recombining iodine atoms is transferred to the surrounding xenon atoms. Our examination of geminate recombination demonstrates that iodine atoms confined within xenon clusters—whether through manual insertion of atoms or the fast dissociation of an iodine molecule within xenon clusters—are more likely to recombine as primary geminate recombination. However, extending the iodine molecule dissociation time allows iodine atoms to diffuse out of the cluster, and the recombination to shift toward secondary geminate recombination.

Cage effect↗

Modeling betatron radiation using particle-in-cell codes for plasma wakefield accelerator diagnostics

The analysis of plasma wakefield acceleration experimental measurements, particularly in the characterization of photons emitted through the betatron radiation mechanism, requires the development of accurate numerical models. These computational models are crucial for supporting modern instrumentation designed to measure the single-shot, double-differential angular-energy radiation spectra resulting from interactions between beams and plasmas. Motivated by the needs of such applications, this paper presents detailed numerical models of betatron radiation generated in beam-plasma acceleration experiments. These models are based on the integration of the Liénard-Wiechert (LW) potentials, applied to computed particle trajectories. The particle trajectories are generated using three distinct methods: first, by tracking particles through idealized fields in the blowout regime of PWFA; second, by obtaining trajectories using the fast quasistatic particle-in-cell (PIC) code quickpic; and third, obtaining trajectories from the fully self-consistent PIC code osiris. To ensure the accuracy and reliability of these models, the paper includes various benchmark tests using analytical expressions, as well as employing the PIC code epoch, which takes an alternative approach by using a Monte Carlo quantum electrodynamics (QED)-based radiation model. Additionally, the paper presents simulations of the expected experimental betatron radiation spectra, taking into account parameters relevant to PWFA and plasma photocathode experiments at the SLAC FACET-II facility.

Yadav, M. [University of California, Los Angeles, ↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Laser cooling of atoms at narrow optical transitions in fields with a polarisation gradient

The efficiency of the polarisation mechanisms of laser cooling of atoms is analysed using narrow optical transitions for which the recoil energy is greater than or comparable to the natural line width. By the example of atoms with the J{sub g} = 1 → J{sub e} = 2 optical transition (J{sub g} and J{sub e} are the total angular momenta of the ground and excited states) in the resonant light fields of σ{sub +} – σ{sub –} and lin⊥lin configurations, the analysis of the minimum achievable energies of laser-cooled atoms is performed. It is shown that the polarisation mechanisms of laser cooling under conditions of a significant influence of recoil effects become less efficient and do not lead to average kinetic energies of an ensemble of atoms below the Doppler limit. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous observations of the blazar PKS 2155-304 from ultra-violet to TeV energies

Here we report the results of the first ever contemporaneous multi-wavelength observation campaign on the BL Lac object PKS 2155−304 involving Swift , NuSTAR , Fermi -LAT, and H.E.S.S. The use of these instruments allows us to cover a broad energy range, which is important for disentangling the different radiative mechanisms. The source, observed from June 2013 to October 2013, was found in a low flux state with respect to previous observations but exhibited highly significant flux variability in the X-rays. The high-energy end of the synchrotron spectrum can be traced up to 40 keV without significant contamination by high-energy emission. A one-zone synchrotron self-Compton model was used to reproduce the broadband flux of the source for all the observations presented here but failed for previous observations made in April 2013. A lepto-hadronic solution was then explored to explain these earlier observational results.

79 ASTRONOMY AND ASTROPHYSICS↗

2022 Prentice Award Lecture: Advancing Retinal Imaging and Visual Function in Patient Management and Disease Mechanisms

Patient-based research plays a key role in probing basic visual mechanisms. Less-well recognized is the role of patient-based retinal imaging and visual function studies in elucidating disease mechanisms, which are accelerated by advances in imaging and function techniques and are most powerful when combined with the results from histology and animal models. A patient's visual complaints can be one key to patient management, but human data are also key to understanding disease mechanisms. Unfortunately, pathological changes can be difficult to detect. Before advanced retinal imaging, the measurement of visual function indicated the presence of pathological changes that were undetectable with existing clinical examination. Over the past few decades, advances in retinal imaging have increasingly revealed the unseen. This has led to great strides in the management of many diseases, particularly diabetic retinopathy and macular edema, and age-related macular degeneration. It is likely widely accepted that patient-based research, as in clinical trials, led to such positive outcomes. Both visual function measures and advanced retinal imaging have clearly demonstrated differences among retinal diseases. Contrary to initial thinking, sight-threatening damage in diabetes occurs to the outer retina and not only to the inner retina. This has been clearly indicated in patient results but has only gradually entered the clinical classifications and understanding of disease etiology. There is strikingly different pathophysiology for age-related macular degeneration compared with photoreceptor and retinal pigment epithelial genetic defects, yet research models and even some treatments confuse these. It is important to recognize the role that patient-based research plays in probing basic visual mechanisms and elucidating disease mechanisms, combining these findings with the concepts from histology and animal models. Thus, this article combines sample instrumentation from my laboratory and progress in the fields of retinal imaging and visual function.

60 APPLIED LIFE SCIENCES↗