Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microcalorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

Fine Optimization of TES Design for the X-IFU Instrument on ATHENA

The X-ray Integral Field Unit (X-IFU) instrument on the Advanced Telescope for High ENergy Astrophysics (ATHENA) is baselined to have 3168 transition-edge sensor (TES) microcalorimeter pixels. These pixels will be DC biased and readout using time division multiplexing. We recently reported a demonstration of the required pixel and readout performance in 252 pixels from a 1 kilo-pixel array (e.g. 2.16 eV resolution for 6.9 keV X-rays). Having achieved the required performance, the 50um square TES design in this demonstration array is considered the baseline pixel design for X-IFU. However, by making small adjustments to the TES design, we may be able to make small but consequential improvements to the instrument performance, while staying within the many constraints of the X-IFU requirements. In this presentation, we will show results from newly fabricated devices with subtle changes from the baseline TES design to further optimize the performance for X-IFU. We will discuss optimizing the TES sheet resistance, normal metal features, X-ray absorber attachment points, TES aspect ratio, and heat capacity. These minor design changes can have significant effects on thermo-electric time constants, thermal fluctuation noise, resistive transition shape and uniformity, and non-linearity of X-ray event pulses. In addition, full characterization of these new TES designs allows greater understanding of the relevant physics within the TES and gives routes for further optimization.

Nick Wakeham↗

The Athena/X-IFU, from Detector Development to Scientific Feasibility Studies via Simulations

The investigation of the physical hot and energetic phenomena in the Universe will further improve our understanding of the assembly of the largest structures and massive halos of galaxies, and of the role of black holes in shaping the Universe as we see it. Spatially resolved X-ray high-resolution spectroscopy will be a crucial tool to achieve these scientific goals. The X-IFU instrument onboard the Athena observatory will provide us with these capabilities through the use of arrays of Transition edge microcalorimeters detectors. These superconducting devices will deliver the required exquisite spectral resolution needed to achieve the core science objectives, such as the characterization of turbulence and bulk motions in the hot gaseous atmospheres of groups and clusters of galaxies in order to unveil the process of large scale structures assembly. I will present the Transition Edge Sensors principle, the status of the instrumental development for the X-IFU instrument, and discuss their performance in view of the scientific objectives of the Athena mission. I will further present the case of a feasibility study and optimisation of the observing strategy for the characterization of the internal dynamics of the intra-cluster medium, through the use of mock simulations of observations with the X-IFU instrument.

Sophie Beaumont↗

Finding and Fixing a Small Low Temperature Leak - A Case Study on XRISM/Resolve

The Resolve instrument on the X-Ray Imaging and Spectroscopy Mission (XRISM) uses an Adiabatic Demagnetization Refrigerator (ADR) to cool extremely sensitive x-ray microcalorimeters to 50 mK. A 40-liter superfluid helium dewar and a 4.5 K Joule Thomson (JT)/Stirling cryocooler serve as heat sinks for the ADR and staged cooling for the dewar. The superfluid helium lifetime is required to last at least 3 years on orbit with margin. The superfluid helium dewar developed a small leak (~5e-7 Pa m^3/s) at low temperature which compromised the dewar vacuum in two days of ground testing. It turns out that this leak disappears completely at room temperature (<5e-13 Pa m^3/s). This presentation describes the lengthy process of characterizing, isolating, and ultimately, repairing this leak.

Michael DiPirro↗

Development of an End-to-end Demonstration Readout Chain for Athena/X-IFU

The X-ray Integral Field Unit(X-IFU) of the Athena observatory, scheduled for launch in the mid2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved with a 2kilo-pixel array of transition-edge sensor (TES) microcalorimeters. The complete detection chain is under development by a large international collaboration. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench uses a two-stage ADR cryostat from Entropy GmbH, a 1024-pixelarray, and will initially be operated using a warm electronics chain from NIST and NASA Goddard Space Flight Center. We describe the complete system being installed in the cryostat and the current results obtained with these electronics. We also review the status of the integration of the digital readout electronics (DRE)prototype into the demonstration chain and the plan for integrating and testing the complete X-IFU readout chain.

S Beaumont↗

Refinement of Transition-Edge Sensor Dimensions for the X-ray Integral Field Unit on ATHENA

At NASA Goddard Space Flight Center, we have previously demonstrated a kilo-pixel array of transition-edge sensor (TES) microcalorimeters capable of meeting the energy resolution requirements of the future X-ray Integral Field Unit (X-IFU) instrument that is being developed for the Advanced Telescope for High ENergy Astrophysics (ATHENA) observatory satellite. The TES design in this array was a square device with side length of 50 μm. Here, we describe studies of TES designs with small variations of the dimensions, exploring lengths, parallel to the current direction, ranging from 75μm to 50μm and widths, perpendicular to the current direction, ranging from 50μm to 15 μm. We describe how these changes impact transition properties, thermal conductance and magnetic field sensitivity. In particular, we show that using a TES with a length of 50μm and width of 30μm may be a promising route to reduce the maximum time-derivative of the TES current in an X-ray pulse and reduce the sensitivity of the TES to magnetic field.

N A Wakeham↗

Effect of Space Radiation on TES Detectors Performance

The Athena mission and its X-IFU instrument (X-ray Integral Field Unit) will be positioned at the Sun-Earth Lagrangian point L1, where it will be subject to solar wind (low flux plasma of 95% protons and 5% alpha particles) with energy below 0.1 MeV, and to galactic cosmic rays and solar flares (energetic protons, alpha particles, and electrons) with energies up to hundreds of MeV for protons and the GeV for heavier ions. Some of these particles will go through the satellite and hit the focal plane assembly and hence the detectors. These detectors will be TES (Transition-edge sensor) microcalorimeters, flown for the first time in such an environment. In order to ensure the performance of this type of detectors throughout the duration of such mission, it is critical to study the impact of the radiation on their behavior. Indeed, although a lot of reference material exist for semiconductor detectors such as CCDs, little is currently known about the impact of radiation on TES detectors. These energetic events could cause local heating or damage to the detectors and affect their performance. In this work, we describe how we designed a test campaign to assess the impact of L1 radiation on TES detectors for Athena/X-IFU-like missions and present the results of the tests. Analyses includes assessing changes in the pulse shapes and energy resolution of the detectors measured at 55 mK after several radiation dose steps performed at 4 K.

Sophie Beaumont↗

Long Term Performance Stability of TES Detectors

We are developing superconducting transition-edge sensor (TES) microcalorimeter arrays for a variety of applications such as ground-based laboratory astrophysics experiments and next generation space-based X-ray missions. These detectors can provide X-ray spectral information with an unprecedent resolution of ~2 eV at 6 keV and have been selected for the X-ray Integral Field Unit (X-IFU) instrument of ESA’s large flagship mission Athena. To maintain detector performance over the lifetime of the mission, it is important to understand whether environmental conditions that the detector may be exposed to will affect its properties over time. This “aging” begins right after the array leaves the fabrication environment, with potential exposure to humidity, oxygen, or elevated temperatures which may affect the detector performance. In a few prior arrays we have observed increased fall times in the pulse shape and/or the introduction of anomalous low energy tails on the X-ray spectrum. This is thought to be an indication of “aging” on chips exposed to such conditions, causing e.g. changes in the absorber properties. In this contribution, we report on a systematic characterization of TES properties, before and after exposing the chip to various controlled temperature and humidity levels and assess the changes in the measured transition and pulse shapes, energy resolution, and spectral redistribution.

S Beaumont↗

Line Emission Mapper Probing Physics of Cosmic Ecosystems

The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe’s structure formation. It will also provide transformative new observing capabilities for every area of astrophysics, and to heliophysics and planetary physics as well. LEM’s main goal is a comprehensive look at the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. These processes are best studied in X-rays; as emphasized by the 2020 Decadal Survey, emission-line mapping is the pressing need in this area. LEM will use a large microcalorimeter array/IFU (that builds on Athena XIFU technology developments), covering a 30 × 300 field with 1000 angular resolution, to map the soft Xray line emission from objects that constitute galactic ecosystems. These include supernova remnants, star-forming regions, superbubbles, galactic outflows (such as the Fermi/eROSITA bubbles in the Milky Way and their analogs in other galaxies), the Circumgalactic Medium in the Milky Way and other galaxies, and the Intergalactic Medium at the outskirts and beyond the confines of galaxies and clusters. LEM’s 1–2 eV spectral resolution in the 0.2–2 keV band will make it possible to disentangle the faintest emission lines in those objects from the bright Milky Way foreground, providing groundbreaking measurements of the physics of these plasmas, from temperatures, densities, chemical composition to gas dynamics. While the mission is optimized to provide critical observations that will push our understanding of galaxy formation, LEM will provide transformative capability for all classes of astrophysical objects, from the Earth’s magnetosphere, planets and comets to the interstellar medium and X-ray binaries in nearby galaxies, AGN, and cooling gas in galaxy clusters. In addition to pointed observations, LEM will perform a shallow all-sky survey that will dramatically expand the discovery space.

Ralph Kraft↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

On-Orbit Performance of the Adiabatic Demagnetization Refrigerator on XRISM

The X-ray Imaging and Spectroscopy Mission (XRISM) observatory was launched on Sep 7, 2023 from Tanegashima Space Center in Japan. Resolve, one its two instruments, performs high-resolution spectroscopy in the soft x-ray band (0.2-13 keV) using a 6x6 microcalorimeter array. The array cooled to 50 mK by a 3-stage ADR, which is linked to both a liquid helium dewar (at <1.2 K) and a Joule-Thomson (JT) cryocooler operating at <4.5 K. While liquid helium is present, two of the ADR stages provide detector cooling at 50 mK and auxiliary cooling to 0.5 K to intercept some parasitic heat loads, while rejecting waste heat to the helium. Once the helium is exhausted, Resolve enters a cryogen-free mode in which all three ADR stages are operated to provide detector cooling at 50 mK and to continuously cool the helium tank to 1.4 K. In this mode, waste heat is rejected to the JT cryocooler. Cryogen-free operation can be sustained as long as the JT and other cryocoolers remain fully operational. At launch, the helium tank contained approximately 35.6 liters of liquid. Within a few days, the helium cooled below 1.15 K, with an estimated 35.0 liters remaining. With an expected time average heat load of 0.68 mW, the helium lifetime was projected to exceed 4 years, but measurements of He volume on orbit suggest a significantly longer lifetime. Details of the ADR’s design and performance are presented.

x-ray astromony↗

Measuring the Liquid Helium Volume on XRISM and Predicting the Liquid Lifetime

The XRISM/Resolve instrument uses an adiabatic demagnetization refrigerator (ADR) to cool microcalorimeters to 50 mK. The cryogenic system to support the ADR consists of a liquid helium dewar and 5 cryocoolers that provide a semi-redundant system. Operation of the ADR requires either a liquid helium heat sink at 1.2 K or 4.5 K heat sink provided by a multi-stage cryocooler system. The 5 cryocoolers also provide thermal protection to the liquid helium dewar. To calculate the expected lifetime of the liquid helium system, the liquid helium volume was measured before launch and several techniques were employed to determine on-orbit boil off rate.

Michael Dipirro↗

Qualification of A Transition Edge Sensor Based Anti-Coincidence Detector for A Probe Class Mission

The Line Emission Mapper (or LEM) is an X-ray probe class mission aimed to study the physics of galaxy formation, with a large field-of-view, high-resolution transition-edge sensor (TES) microcalorimeter. Because of the diffuse and faint nature of LEM’s targets, a high-fidelity anticoincidence detector (anti-co) is essential to reduce instrument background below the level of sky background. Lying directly behind the LEM sensor, the anti-co will detect ~3 counts per second per square centimeter from background galactic cosmic rays and the secondary particles they induce to detect and flag any events that could be confused with a science photon in the 0.3-2 keV signal band of LEM. Our design spans an active region 4-cm in diameter. It consists of 12 quasiparticle-trap-assisted electrothermal-feedback (QET) channels, each with 100 parallel TESes with common bias lines. The TES is a narrow strip of Mo/Au bilayer. We present fabrication processes that maintain the transition temperature (T c ) in Mo/Au bilayer structures across the active region. We further present a new design based on a a-Si/W TES layer that has previously achieved reasonable uniformity in lab testing.

x-ray↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of less than 4x10(exp -18) W/(Hz)0.5(exp 0.5). Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

radiation - blocking filters↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV. The properties that make the SXS a powerful x-ray spectrometer also make it sensitive to the entire electromagnetic band. If characterized as a bolometer, it would have a noise equivalent power (NEP) of < 4x10(exp -18) W/(Hz)0.5. Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. These needs are addressed by a series of five thin-film radiation blocking filters that block long-wavelength radiation while minimizing x-ray attenuation. The SXS aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three warmer filters also were equipped with thermometers and heaters for decontamination.

microcalorimeter↗