Search NASA⌕ Search

SEARCH · Search NASA

Results for “Missing data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Accurate geometries for “Mountain pass” regions of the Ramachandran plot using quantum chemical calculations

Unusual local arrangements of protein in Ramachandran space are not well represented by standard geometry tools used in either protein structure refinement using simple harmonic geometry restraints or in protein simulations using molecular mechanics force fields. In contrast, quantum chemical computations using small poly-peptide molecular models can predict accurate geometries for any well-defined backbone Ramachandran orientation. Additionally, for conformations along transition regions-$\phi$ from -60 to 60°-a very good agreement with representative high-resolution experimental X-ray (≤1.5 Å) protein structures is obtained for both backbone C -1 -N-C α angle and the nonbonded O -1 …C distance, while "standard geometry" leads to the "clashing" of O…C atoms and Amber FF99SB predicts distances too large by about 0.15 Å. These results confirm that quantum chemistry computations add valuable support for detailed analysis of local structural arrangements in proteins, providing improved or missing data for less understood high-energy or unusual regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linkage map construction using limited parental genotypic information

Abstract Genetic linkage maps based on single nucleotide polymorphisms (SNPs) represent an essential tool for a variety of genomic analyses. Today, next-generation sequencing (NGS) enables rapid genotyping of different mapping populations based on thousands of SNPs and the construction of highly saturated linkage maps. Nevertheless, missing data in the genotyping of the parental lines creates a bottleneck that determines the number of SNPs that can be used for the linkage map. As a proof of concept, a highly saturated genetic linkage map was constructed using the imputed genotypic data of a recombinant inbred line (RIL) population and the limited genotypic information of its parental lines. Two ABH genotype files were created from a pseudo-parental genotypic data set that includes all the SNPs present in the RIL population. In the first ABH file pseudo-parental 1 was considered parental A, while in the second pseudo-parental 1 was considered parental B. These two duplicate ABH genotype files were merged by chromosome and subjected to linkage map analysis. Since the ABH data were duplicated, two mirrored linkage groups were generated per chromosome. The correct linkage map was identified and selected based on the partial genotypic data of the parental lines. This strategy was effective for constructing a highly saturated linkage map of 33,421 SNPs based on the genotyping of 205 RILs and a limited number of 100 SNPs present in the parental lines. This strategy enables the use of all the NGS SNP data obtained from a low-coverage sequencing experiment in the mapping population.

59 BASIC BIOLOGICAL SCIENCES↗

Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D{sub 1} increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D{sub 5} dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes in a Multi-institutional Cohort of Patients Treated With Intraoperative Radiation Therapy for Advanced or Recurrent Renal Cell Carcinoma

Purpose/Objective(s): This study aimed to analyze outcomes in a multi-institutional cohort of patients with advanced or recurrent renal cell carcinoma (RCC) who were treated with intraoperative radiation therapy (IORT). Methods and Materials: Between 1985 and 2010, 98 patients received IORT for advanced or locally recurrent RCC at 9 institutions. The median follow-up time for surviving patients was 3.5 years. Overall survival (OS), disease-specific survival (DSS), and disease-free survival (DFS) were estimated with the Kaplan-Meier method. Chained imputation accounted for missing data, and multivariate Cox hazards regression tested significance. Results: IORT was delivered during nephrectomy for advanced disease (28%) or during resection of locally recurrent RCC in the renal fossa (72%). Sixty-nine percent of the patients were male, and the median age was 58 years. At the time of primary resection, the T stages were as follows: 17% T1, 12% T2, 55% T3, and 16% T4. Eighty-seven percent of the patients had a visibly complete resection of tumor. Preoperative or postoperative external beam radiation therapy was administered to 27% and 35% of patients, respectively. The 5-year OS was 37% for advanced disease and 55% for locally recurrent disease. The respective 5-year DSS was 41% and 60%. The respective 5-year DFS was 39% and 52%. Initial nodal involvement (hazard ratio [HR] 2.9-3.6, P<.01), presence of sarcomatoid features (HR 3.7-6.9, P<.05), and higher IORT dose (HR 1.3, P<.001) were statistically significantly associated with decreased survival. Adjuvant systemic therapy was associated with decreased DSS (HR 2.4, P=.03). For locally recurrent tumors, positive margin status (HR 2.6, P=.01) was associated with decreased OS. Conclusions: We report the largest known cohort of patients with RCC managed by IORT and have identified several factors associated with survival. The outcomes for patients receiving IORT in the setting of local recurrence compare favorably to similar cohorts treated by local resection alone suggesting the potential for improved DFS with IORT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nomogram for Predicting the Risk of Locoregional Recurrence in Patients Treated With Accelerated Partial-Breast Irradiation

Purpose: To develop a nomogram taking into account clinicopathologic features to predict locoregional recurrence (LRR) in patients treated with accelerated partial-breast irradiation (APBI) for early-stage breast cancer. Methods and Materials: A total of 2000 breasts (1990 women) were treated with APBI at William Beaumont Hospital (n=551) or on the American Society of Breast Surgeons MammoSite Registry Trial (n=1449). Techniques included multiplanar interstitial catheters (n=98), balloon-based brachytherapy (n=1689), and 3-dimensional conformal radiation therapy (n=213). Clinicopathologic variables were gathered prospectively. A nomogram was formulated utilizing the Cox proportional hazards regression model to predict for LRR. This was validated by generating a bias-corrected index and cross-validated with a concordance index. Results: Median follow-up was 5.5 years (range, 0.9-18.3 years). Of the 2000 cases, 435 were excluded because of missing data. Univariate analysis found that age <50 years, pre-/perimenopausal status, close/positive margins, estrogen receptor negativity, and high grade were associated with a higher frequency of LRR. These 5 independent covariates were used to create adjusted estimates, weighting each on a scale of 0-100. The total score is identified on a points scale to obtain the probability of an LRR over the study period. The model demonstrated good concordance for predicting LRR, with a concordance index of 0.641. Conclusions: The formulation of a practical, easy-to-use nomogram for calculating the risk of LRR in patients undergoing APBI will help guide the appropriate selection of patients for off-protocol utilization of APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Patient Reporting of Symptomatic Adverse Events via the Patient-Reported Outcomes Version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE) in a Chemoradiotherapy Cooperative Group Multicenter Clinical Trial

Purpose: To assess the feasibility of measuring symptomatic adverse events (AEs) in a multicenter clinical trial using the National Cancer Institute's Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE). Methods and Materials: Patients enrolled in NRG Oncology's RTOG 1012 (Prophylactic Manuka Honey for Reduction of Chemoradiation Induced Esophagitis-Related Pain during Treatment of Lung Cancer) were asked to self-report 53 PRO-CTCAE items representing 30 symptomatic AEs at 6 time points (baseline; weekly ×4 during treatment; 12 weeks after treatment). Reporting was conducted via wireless tablet computers in clinic waiting areas. Compliance was defined as the proportion of visits when an expected PRO-CTCAE assessment was completed. Results: Among 226 study sites participating in RTOG 1012, 100% completed 35-minute PRO-CTCAE training for clinical research associates (CRAs); 80 sites enrolled patients, of which 34 (43%) required tablet computers to be provided. All 152 patients in RTOG 1012 agreed to self-report using the PRO-CTCAE (median age 66 years; 47% female; 84% white). Median time for CRAs to learn the system was 60 minutes (range, 30-240 minutes), and median time for CRAs to teach a patient to self-report was 10 minutes (range, 2-60 minutes). Compliance was high, particularly during active treatment, when patients self-reported at 86% of expected time points, although compliance was lower after treatment (72%). Common reasons for noncompliance were institutional errors, such as forgetting to provide computers to participants; patients missing clinic visits; Internet connectivity; and patients feeling “too sick.” Conclusions: Most patients enrolled in a multicenter chemoradiotherapy trial were willing and able to self-report symptomatic AEs at visits using tablet computers. Minimal effort was required by local site staff to support this system. The observed causes of missing data may be obviated by allowing patients to self-report electronically between visits, and by using central compliance monitoring. These approaches are being incorporated into ongoing studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal sensor placement for reconstructing wind pressure field around buildings using compressed sensing

Deciding how to optimally deploy sensors in a large, complex, and spatially extended structure is critical to ensure that the surface pressure field is accurately captured for subsequent analysis and design. In some cases, reconstruction of missing data is required in downstream tasks such as the development of digital twins. Here, this paper presents a data-driven sparse sensor selection algorithm, aiming to provide the most information contents for reconstructing aerodynamic characteristics of wind pressures over tall building structures parsimoniously. The algorithm first fits a set of basis functions to the training data, then applies a computationally efficient QR algorithm that ranks existing pressure sensors in order of importance based on the state reconstruction to this tailored basis. The findings of this study show that the proposed algorithm successfully re- constructs the aerodynamic characteristics of tall buildings from sparse measurement locations, generating stable and optimal solutions across a range of conditions. As a result, this study serves as a promising first step toward leveraging the success of data-driven and machine learning algorithms to supplement traditional genetic algorithms currently used in wind engineering.

42 ENGINEERING↗

Prediction of Transition-State Energies of Hydrodeoxygenation Reactions on Transition-Metal Surfaces Based on Machine Learning

Computational catalyst discovery involves identification of a meaningful model and suitable descriptors that determine the catalyst properties. We study the impact of combining various descriptors (e.g., reaction energies, metal descriptors, and bond counts) for modeling transition-state energies (TS) based on a database of adsorption and TS energies across transition-metal surfaces for the decarboxylation and decarbonylation of propionic acid, a chemistry characteristic for biomass conversion. Results of different machine learning models for more than 1572 descriptor combinations suggest that there is no statistically significant difference between linear and nonlinear models when using the right combination of reactant energies, metal descriptors, and bond counts. However, linear models are inferior when not including bond count and metal descriptors. In conclusion, when there are missing data for reaction steps on all metals, conventional linear scaling is inferior to linear and nonlinear models with proper choice of descriptors that are surprisingly robust.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into Prismatic Loop Formation in Irradiated Fe–Cr Alloys from Hypothesis-Driven Active Learning and Causal Analysis

Neutron and electron irradiation experimental studies conducted on body-centered cubic Fe and Fe–Cr alloys have established two prismatic dislocation loop populations, which have Burgers vectors of either a/2$\langle$111$\rangle$ or a$\langle$100$\rangle$. Here, the loop formation depends on factors such as dose (D), dose rate (D rt ), temperature (T), chromium content (Cr%), and other alloying elements. Hence, it is important to understand how irradiation-induced dislocation loops evolve conditional upon the loop characteristics, such as loop density (DD), average loop size d̅, and irradiation parameters (D, D rt , T, and irradiation type), which is still an active area of research. To understand these complex structure–property relationships, machine learning (ML) is employed in a three-step approach. This includes imputing missing data with a k-nearest neighbor, generating functionalized features, and assessing feature importance with random forest classification and regression. Physics-based features are incorporated in a hypothesis-driven active learning scheme to overcome data unavailability challenges. Insights obtained from ML models (i) to categorize dislocation loop types, show the highest correlation with d̅; (ii) Log(DD), obtained through mathematical formulations involving D, Cr%, d̅, and T (e.g., Log(DD) ~ D + exp(-Cr%) + 1/d̅ and log(DD) ~ D + exp(-Cr%) + 1/T). Hypothesis-driven active learning is able to predict Log(DD) in which the experimental date is not known. Causal models verify cause–effect relationships for dislocation loop classification and irradiation factors in FeCr alloys.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Chemical Approach for Calculating Stability Constants of Mercury Complexes

Stability constants are central to the multi-scale modeling of the thermodynamic speciation, cycling, and transport of mercury (Hg) and other contaminants in aquatic environments. However, for Hg, experimental values for many relevant complexes are not available, and for others can span ranges in excess of 10 log units. The missing data and large uncertainties mean there are significant knowledge gaps in predictions of thermodynamic speciation. As an alternative to experimental measurements, thermodynamic quantities can be calculated with quantum chemical methods. Among these, density functional theory (DFT) with a polarizable continuum solvent combines accuracy with practicability. In this paper, we present an accurate and quick approach in which we use DFT with continuum solvation to calculate stability constants of Hg complexes with inorganic and low molecular-weight organic ligands in aqueous solution. Specifically, we use the M06/[SDD]6-31+G(d,p) level of theory in combination with a modified version of the SMD solvent model in which the solute radii are re-optimized with a scaled solvent-accessible surface (sSAS) approach. For the set of 37 Hg complexes used for optimization, which contain environmentally relevant functional groups and have reliable experimental stability constants, we obtain a mean unsigned error of 1.4 log units. Testing the method on an independent set of 12 Hg complexes reproduces the experimental stability constants to a mean unsigned error of 1.6 log units. Finally, this approach is a substantial step toward generally applicable rapid stability constant derivation for a wide range of Hg complexes, including those present in dissolved organic matter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of TMT Labeling Efficiency in Large-Scale Quantitative Proteomics: The Critical Effect of Sample pH

Isobaric labeling via tandem mass tag (TMT) reagents enables sample multiplexing prior to LC–MS/MS, facilitating high-throughput large-scale quantitative proteomics. Consistent and efficient labeling reactions are essential to achieve robust quantification; therefore, embedded in our clinical proteomic protocol is a quality control (QC) sample that contains a small aliquot from each sample within a TMT set, referred to as “Mixing QC.” This Mixing QC enables the detection of TMT labeling issues by LC–MS/MS before combining the full samples to allow for salvaging of poor TMT labeling reactions. While TMT labeling is a valuable tool, factors leading to poor reactions are not fully studied. We observed that relabeling does not necessarily rescue TMT reactions and that peptide samples sometimes remained acidic after resuspending in 50 mM HEPES buffer (pH 8.5), which coincided with low labeling efficiency (LE) and relatively low median reporter ion intensities (MRIIs). To obtain a more resilient TMT labeling procedure, we investigated LE, reporter ion missingness, the ratio of mean TMT set MRII to individual channel MRII, and the distribution of log 2 reporter ion ratios of Mixing QC samples. We discovered that sample pH is a critical factor in LE, and increasing the buffer concentration in poorly labeled samples before relabeling resulted in the successful rescue of TMT labeling reactions. Moreover, resuspending peptides in 500 mM HEPES buffer for TMT labeling resulted in consistently higher LE and lower missing data. By better controlling the sample pH for labeling and implementing multiple methods for assessing labeling quality before combining samples, we demonstrate that robust TMT labeling for large-scale quantitative studies is achievable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fused x-ray and fast neutron CT reconstruction for imaging large and dense objects

Megavolt x-ray computed tomography (CT) is a powerful tool for three-dimensional characterization. However, its utility is limited for large objects composed of high-atomic number (Z) materials, where x rays fail to penetrate. Information from fast neutron CT (FNCT) can complement x-ray CT reconstructions since fast neutrons can more readily penetrate high-Z objects. In this work, we demonstrate a method for combining FNCT and x-ray CT data to create a single reconstruction, more accurate than could be achieved with either x rays or fast neutrons alone. The algorithm was tested on an exemplar comprising multiple concentric, nested cylinders of different materials. Simulated and empirical x-ray CT data were acquired for the exemplar using a 9 MV bremsstrahlung spectrum. Additional simulated and empirical FNCT data were acquired using an accelerator based fast neutron source. The FNCT data were used to synthesize x-ray CT data and augment the x-ray CT data missing due to lack of penetration. This approach mitigates artifacts that would otherwise negatively affect the accuracy and resolution of a single-modality reconstructed volume.

47 OTHER INSTRUMENTATION↗

Bayesian inference of anisotropic 2D small-angle scattering from sparse measurement

Here, we present a Bayesian inference framework for reconstructing anisotropic two-dimensional small-angle scattering (2D SAS) patterns from sparse, noisy, or partially missing data. The method combines a symmetry-aware angular basis with radial Gaussian process priors to enable accurate, training-free interpolation and denoising. Computational benchmarks demonstrate reliable recovery of both isotropic and high-order anisotropic features under severe data reduction. Experimental validations on stretched polymers, sheared wormlike micelles, and carbon fibers show improved fidelity and resolution compared to raw measurements, achieving comparable accuracy with up to 50-fold fewer detected neutrons. This approach enables quantitative structural analysis under low-flux, time-limited, or single-shot conditions, extending the applicability of 2D SAS techniques to compact neutron sources and mechanically driven soft matter systems undergoing transient structural changes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Stability analysis of WEST L-mode discharges with improved confinement from boron powder injection

WEST L-mode plasmas with dominant electron heating and no core torque source have observed improvements in confinement during boron (B) powder injection. These results are reminiscent of previous powder injection experiments on other devices and gaseous impurity seeding experiments on WEST. During powder injection, the stored energy increased up to 25% due to enhanced ion and electron heat and particle confinement. The improvements in confinement were not indicative of an L-H transition. To identify the dominant mechanisms and the causality chain behind these improvements in confinement, we employ interpretative modeling using METIS, predictive integrated modeling using a high-fidelity plasma simulator (HFPS), and stand-alone gyrokinetic simulations using quasi-linear gyrokinetic code. Interpretative modeling with METIS allowed for the estimation of missing data while maintaining good overall consistency with experiment. These results provided the initial conditions for fully predictive flux driven simulations using the HFPS. From these simulations, quasi-linear gyrokinetic analysis was performed at ρ = 0.5 and ρ = 0.65. Collisionality was found to be a strong candidate for the turbulence suppression mechanism at ρ = 0.5, while a combination of collisionality and the T e /T i ratio was found to be the likely mechanism at ρ = 0.65. The results additionally suggested that increased Z eff (through main ion dilution) could play a role in the improved confinement, but this could not be confirmed due to a lack of experimental measurements. The modeling framework established here can now be used to evaluate and exploit a variety of future powder injection experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Weighted FFT estimators for 1D and 3D correlations of the Lyman- α forest

Correlations in the Lyman-α (Lyα) forest, both as a function of line of sight separation (1D) and 3D separation, provide a unique window to the distribution of matter at redshifts not accessible by current galaxy surveys. While optimal quadratic estimators have been used to measure 1D correlations, they are computationally expensive and difficult to extend to 3D analyses. On the other hand, estimators based on the Fast Fourier Transform (FFT) are significantly faster, but are affected by missing data in the spectra (masked pixels) and so far have not used pixel weights to reduce the uncertainties in the measurement. In this publication we describe how to compute the window matrix that enables forward-modelling the impact of masked pixels and weights on the FFT-based estimators. Here, we use Gaussian and hydrodynamical simulations with artificially masked pixels to validate the method on the measurement of 1D correlations. Finally, we show that the formalism can be extended to model the impact on 3D correlations, in particular on the cross-spectrum, the correlation of 1D Fourier modes as a function of transverse separation. This work will enable more precise clustering measurements with the Lyα forest dataset recently collected by the Dark Energy Spectroscopic Instrument (DESI).

Lokken, Martine [Univ. Autonoma de Barcelona (Spai↗

Overcoming sparse datasets with multi-task learning as applied to high entropy alloys

Abstract The design of novel High Entropy Alloys for use in high-temperature applications is an area of active interest due to their potential to provide exceptional properties compared to conventional alloys. Since the increased popularity of machine learning, an important cog in the design process has been training surrogate models on alloy properties. However, these Single-Task models are trained on individual mechanical properties and do not take advantage of the relatedness between properties. Multi-Task models can capture the interdependencies between tasks, leading to potentially more accurate predictions for all tasks. In this paper, we investigate if Multi-Task models can show improvement over Single-Task models when used for predicting the mechanical properties of these alloys. To ensure fair evaluation between the models, we apply L 0 regularization and skip connections to the models, which allows them to adjust the number of model parameters and depth for optimal performance. We find that the Multi-Task models can leverage task relationships to perform better than Single-Task models, especially for high amounts of missing data in the tasks. Furthermore, adding simple auxiliary targets can boost Multi-Task performance even further despite not being effective as input descriptors to single-task models themselves. We anticipate that the proposed strategies can achieve more accurate predictions and consequently enable better design capabilities for such data-constrained domains without incurring much additional computational cost.

Debnath, Arindam (ORCID:0000000194274499)↗

Pharmacoepidemiology, Machine Learning and COVID-19: An intent-to-treat analysis of hydroxychloroquine, with or without azithromycin, and COVID-19 outcomes amongst hospitalized US Veterans

Hydroxychloroquine (HCQ) was proposed as an early therapy for coronavirus disease 2019 (COVID-19) after in vitro studies indicated possible benefit. Previous in vivo observational studies have presented conflicting results, though recent randomized clinical trials have reported no benefit from HCQ amongst hospitalized COVID-19 patients. In this work, we examined the effects of HCQ alone, and in combination with azithromycin, in a hospitalized COVID-19 positive, United States (US) Veteran population using a propensity score adjusted survival analysis with imputation of missing data. From March 1, 2020 through April 30, 2020, 64,055 US Veterans were tested for COVID-19 based on Veteran Affairs Healthcare Administration electronic health record data. Of the 7,193 positive cases, 2,809 were hospitalized, and 657 individuals were prescribed HCQ within the first 48-hours of hospitalization for the treatment of COVID-19. There was no apparent benefit associated with HCQ receipt, alone or in combination with azithromycin, and an increased risk of intubation when used in combination with azithromycin [Hazard Ratio (95% Confidence Interval): 1.55 (1.07, 2.24)]. In conclusion, we assessed the effectiveness of HCQ with or without azithromycin in treating patients hospitalized with COVID-19 using a national sample of the US Veteran population. Using rigorous study design and analytic methods to reduce confounding and bias, we found no evidence of a survival benefit from the administration of HCQ.

60 APPLIED LIFE SCIENCES↗

A phantom for testing of 4D-CT for radiotherapy of small lesions

Purpose: The use of time-resolved four-dimensional computed tomography (4D-CT) in radiotherapy requires strict quality assurance to ensure the accuracy of motion management protocols. The aim of this work was to design and test a phantom capable of large amplitude motion for use in 4D-CT, with particular interest in small lesions typical for stereotactic body radiotherapy. Methods: The phantom of 'see-saw' design is light weight, capable of including various sample materials and compatible with several surrogate marker signal acquisition systems. It is constructed of polymethylmethacrylate (Perspex) and its movement is controlled via a dc motor and drive wheel. It was tested using two CT scanners with different 4D acquisition methods: the Philips Brilliance Big Bore CT (helical scan, pressure belt) and a General Electric Discovery STE PET/CT (axial scan, infrared marker). Amplitudes ranging from 1.5 to 6.0 cm and frequencies of up to 40 cycles per minute were used to study the effect of motion on image quality. Maximum intensity projections (MIPs), as well as average intensity projections (AIPs) of moving objects were investigated and their quality dependence on the number of phase reconstruction bins assessed. Results: CT number discrepancies between moving and stationary objects were found to have no systematic dependence on amplitude, frequency, or specific interphase variability. MIP-delineated amplitudes of motion were found to match physical phantom amplitudes to within 2 mm for all motion scenarios tested. Objects undergoing large amplitude motions (>3.0 cm) were shown to cause artefacts in MIP and AIP projections when ten phase bins were assigned. This problem can be mitigated by increasing the number of phase bins in a 4D-CT scan. Conclusions: The phantom was found to be a suitable tool for evaluating the image quality of 4D-CT motion management technology, as well as providing a quality assurance tool for intercenter/intervendor testing of commercial 4D-CT systems. When imaging objects with large amplitudes, the completeness criterion described here indicates the number of phase bins required to prevent missing data in MIPs and AIPs. This is most relevant for small lesions undergoing large motions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗