Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Development of ARCHER towards clinical use: modeling and simulation of Varian Linac for radiation therapy dose calculations - 25449

Monte Carlo particle transport methods are well recognized as the most accurate approach to dose calculations for radiation therapy treatment planning. However, the lengthy calculation time has prevented Monte Carlo methods from being applied to dose calculations in the planning of radiation therapy. Recently, the emerging parallel computing hardware accelerators, such as general-purpose Graphics Processing Unit (GPU), have significantly boosted the performance of Monte Carlo codes. The accuracy of a clinical dose engine depends greatly on the accuracy of source term modeling and the methodology of dose calculations. Hence, in this study, an efficient and accurate source model of the Varian TrueBeam{sup R} Linac is developed and integrated with a fast photon-electron transport module of the recently developed high-performance Monte Carlo code, ARCHER. The validity of the source model and the particle transport physics are verified with established dose calculation codes such as EGSnrc and validated with experimental measurements. To demonstrate the capability of the platform in clinical applications, three clinical treatment plans (the lung, breast, and prostate) are simulated and analyzed. From the perspective of performance, the entire simulation of each clinical plan, starting from the source modeling to the end of particle transport within the patient phantom, can be finished in less than one minute using a single Titan X GPU card with 1% statistical error. In comparison, the same cases take the EGSnrc code hundreds of CPU hours to finish. The results suggest that this new version of ARCHER code has been successfully developed and tested as a clinically deployable dose engine for external photon beam IMRT plans in the clinical setting. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Molten Salt Reactor Experiment Simulation using Shift/Griffin

The Department of Energy (DOE)’s NEAMS focuses its efforts on the development of advanced modeling and simulation (M&S) tools for light-water reactors (LWRs) and non–LWRs (i.e., molten salt reactors, high-temperature gas reactors, microreactors, and fast reactors). In the previous fiscal year, the Multiphysics Applications Driver Technical Area funded molten salt reactor (MSR) M&S at Oak Ridge National Laboratory (ORNL) to generate multigroup macroscopic cross sections with Shift for a MSRE 2D lattice model in Griffin. In addition, Shift’s capability to calculate gamma dose rates from activated components in the primary exchangers in a molten salt breeder reactor was also demonstrated. In fiscal year 2023, ORNL generated multigroup macroscopic cross sections using Shift for a 3D MSRE core model. MSRE depletion calculations using Griffin were also demonstrated in this fiscal year. For the depletion calculation, one-group microscopic cross sections for the 3D MSRE core were generated using Shift, and the decay transmutation library from ORIGEN was converted to an ISOXML file, which is required as input in Griffin. Several Monte Carlo codes, such as OpenMC and Serpent, were also used to benchmark and supplement multigroup cross sections generated by Shift. Multigroup libraries were generated with 8 and 20 group structures, and the study found the 8-group structure to be more accurate when comparing Griffin results to continuous energy (CE) Monte Carlo results. The average flux from CE Shift calculations is up to ~6% higher than the CE Serpent calculations because of different values applied for the energy released per fission (κ values). The average flux in the fuel salt calculated by Griffin using cross sections generated with Shift agrees well with the reference CE Shift solution; the same is valid for the corresponding Serpent results. The maximum relative error is ~6% and ~2% compared to the CE Shift and Serpent reference solutions, respectively. Meanwhile, the average flux calculated by Griffin in the graphite moderator shows a higher difference in the thermal range when compared to both reference Monte Carlo solutions; this result suggests a need for improvement in cross section generation for the graphite moderator in the thermal range in both Monte Carlo codes. Griffin depletion calculations using cross sections from Shift and Serpent were performed and compared against ORIGEN calculations, and the nuclide densities calculated by Griffin were found to be generally in agreement with those of ORIGEN. Because a different approach was taken to calculate the energy released per fission ( κ values) in Shift and Serpent, a difference in nuclide densities from differences in the average flux was observed between Griffin using Serpent and Shift cross sections. Griffin calculations with Shift cross sections produced higher average flux in the salt than with Serpent cross sections, leading to higher consumption of 235 U and higher production of 135 Xe. For time-dependent depletion calculations, cross sections were generated with Serpent, and Griffin’s results using these cross sections were compared to CE Serpent depletion results, demonstrating good agreement. The average difference in keff between Serpent and Griffin as a function of burnup is about 155 pcm. Similarly, good agreement with small differences up to ~0.5% was also noticed in the nuclide density of 235 U and 135 Xe. More details regarding the methodologies invoked to generate the cross section to make code-to-code comparisons are discussed further in this report. User feedback on Griffin and Shift capabilities that will enhance these calculations is provided in this report for future consideration. The work performed this fiscal year can be extended further for multiphysics coupling of Griffin-Pronghorn/SAM with Mole to study precursor flow and salt chemistry.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES↗

Data Testing for ENDF/B-VII.1beta2

Calculations have been performed for 390 critical assemblies from the International Handbook of Evaluated Criticality Safety Benchmark Experiments using the beta2 release of ENDF/B-VII.1. The results are compared to previous results for ENDF/B-VII. Cases that changed between the two versions are highlighted, and the results are discussed. The Cross Section Evaluation Working Group (CSEWG) is working on a new release of the ENDF/B-VII library of evaluated nuclear data, and the 'beta2' set of files was recently made available by the National Nuclear Data Center (NNDC). A set of about 850 input files for the MCNP Monte Carlo code to run critical assemblies from the International Handbook of Evaluated Criticality Safety Benchmark Experiments was available from our previous data testing work for ENDF/B-VII.0. We have now run 390 of those cases using data based on the beta2 files, and those results will be presented below. The ENDF files were downloaded from the NNDC to a Mac workstation. They were then processed using NJOY10 into ACE format files for use in the MCNP Monte Carlo code. The processing was limited to materials needed for the data testing work at this point. The existing MCNP input decks were used. No checking was done to see if any of the benchmarks had been updated since the ENDF/B-VII testing was finished. Most runs used 50 million histories in order to get Monte Carlo statistical uncertainties down the 0.01% range.

Atomic and Nuclear Physics↗

Simulating Scintillator Light Collection Using Measured Optical Reflectance

To accurately predict the light collection from a scintillating crystal through Monte Carlo simulations, it is crucial to know the angular distribution from the surface reflectance. Current Monte Carlo codes allow the user to set the optical reflectance to a linear combination of backscatter spike, specular spike, specular lobe, and Lambertian reflections. However, not all light distributions can be expressed in this way. In addition, the user seldom has the detailed knowledge about the surfaces that is required for accurate modeling. We have previously measured the angular distributions within BGO crystals and now incorporate these data as look-up-tables (LUTs) into modified Geant4 and GATE Monte Carlo codes. The modified codes allow the user to specify the surface treatment (ground, etched, or polished), the attached reflector (Lumirror(R), Teflon(R), ESR film, Tyvek(R), or TiO paint), and the bonding type (air-coupled or glued). Each LUT consists of measured angular distributions with 4o by 5o resolution in theta and phi, respectively, for incidence angles from 0? to 90? degrees, in 1o-steps. We compared the new codes to the original codes by running simulations with a 3 x 10 x 30 mm3 BGO crystal coupled to a PMT. The simulations were then compared to measurements. Light output was measured by counting the photons detected by the PMT with the 3 x 10, 3 x 30, or 10 x 30 mm2 side coupled to the PMT, respectively. Our new code shows better agreement with the measured data than the current Geant4 code. The new code can also simulate reflector materials that are not pure specular or Lambertian reflectors, as was previously required. Our code is also more user friendly, as no detailed knowledge about the surfaces or light distributions is required from the user.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A broadband gamma-ray spectrometry using novel unfolding algorithms for characterization of laser wakefield-generated betatron radiation

We present a high-flux, broadband gamma-ray spectrometry capable of characterizing the betatron radiation spectrum over the photon energy range from 10 keV to 20 MeV with respect to the peak photon energy, spectral bandwidth, and unique discrimination from background radiations, using a differential filtering spectrometer and the unfolding procedure based on the Monte Carlo code GEANT4. These properties are experimentally verified by measuring betatron radiation from a cm-scale laser wakefield accelerator (LWFA) driven by a 1-PW laser, using a differential filtering spectrometer consisting of a 15-filter and image plate stack. The gamma-ray spectra were derived by unfolding the photostimulated luminescence (PSL) values recorded on the image plates, using the spectrometer response matrix modeled with the Monte Carlo code GEANT4. The accuracy of unfolded betatron radiation spectra was assessed by unfolding the test PSL data simulated with GEANT4, showing an ambiguity of less than 20% and clear discrimination from the background radiation with less than 10%. The spectral analysis of betatron radiation from laser wakefield-accelerated electron beams with energies up to 3 GeV revealed radiation spectra characterized by synchrotron radiation with the critical photon energy up to 7 MeV. The gamma-ray spectrometer and unfolding method presented here facilitate an in-depth understanding of betatron radiation from LWFA process and a novel radiation source of high-quality photon beams in the MeV regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Markov chain Monte Carlo study on dark matter property related to the cosmic e{sup {+-}}excesses

In this paper we develop a Markov chain Monte Carlo code to study the dark matter properties in frameworks to interpret the recent observations of cosmic ray electron/positron excesses. We assume that the dark matter particles couple dominantly to leptons and consider two cases, annihilating or decaying into lepton pairs, respectively. The constraint on the central density profile from the H.E.S.S. observation of diffuse {gamma} rays around the Galactic center is also included in the Markov chain Monte Carlo code self-consistently. In the numerical study, we have considered two cases of the background: fixed e{sup +}e{sup -} background and the relaxed one. Two data sets of electrons/positrons, i.e. PAMELA+ATIC (Data set I) and PAMELA+Fermi-LAT+H.E.S.S. (Data set II), are fitted independently, considering the current inconsistence between the observational data. We find that for Data set I, dark matter with m{sub {chi}{approx_equal}0}.70 TeV for annihilation (or 1.4 TeV for decay) and a non-negligible branching ratio to e{sup +}e{sup -} channel is favored; while for Data set II, m{sub {chi}{approx_equal}2}.2 TeV for annihilation (or 4.5 TeV for decay) and the combination of {mu}{sup +{mu}-} and {tau}{sup +{tau}-} final states can best fit the data. We also show that the background of electrons and positrons actually will significantly affect the branching ratios. The H.E.S.S. observation of {gamma} rays in the Galactic center ridge puts a strong constraint on the central density profile of the dark matter halo for the annihilation dark matter scenario. In this case the Navarro-Frenk-White profile, which is regarded as the typical predication from the cold dark matter scenario, is excluded with a high significance (>3{sigma}). For the decaying dark matter scenario, the constraint is much weaker.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial steady-state core simulation capability or thermal and pool-type molten salt reactors, coupling reactor physics, thermal-hydraulics, and evolving chemistry

This report presents the development and validation of an initial steady-state multiphysics capability for molten salt reactors (MSRs) under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in Fiscal Year 2025. The framework integrates neutronics, thermal-hydraulics, species transport, and thermochemistry to capture the coupled dynamics of liquid-fueled systems. Implementation and testing were performed on two representative designs: the Molten Salt Reactor Experiment (MSRE), a thermal-spectrum, channeled-flow reactor, and the Lotus Molten Salt Reactor (L-MSR), a fast-spectrum, pool-type reactor. The modeling suite employs Griffin for reactor physics and depletion, Pronghorn and SAM for thermal-hydraulics, Thermochimica for chemistry, and Saline for thermophysical properties, with benchmarking and validation carried out against historical MSRE data, experimental flow-loop measurements, and reference depletion calculations from Monte Carlo codes. The framework demonstrated the ability to reproduce key reactor behaviors including temperature feedback, reactivity losses, delayed neutron precursor transport, xenon poisoning, and redox potential evolution. The results confirm the feasibility and accuracy of the coupled models in predicting steady-state and selected transient MSR behaviors. This latter ones are used in this report as a proxy indicating that the steady-state models from which the transient starts are accurate. For MSRE, validation showed good agreement with pump start-up and natural circulation tests, while for the L-MSR, benchmarking confirmed hydraulic calibration and consistency of neutronics–thermal coupling. The tools also provided new insights into species transport, noble metal deposition, and salt solidification dynamics. On the Xenon transport front, the code is validated against the steady state Xenon poisoining measurement and showed good agreement with the experimental value. Identified areas for future work include advanced void transport modeling, three-dimensional simulations, improved alloy corrosion models, and tighter integration with high-fidelity Monte Carlo codes. These developments provide a foundation for high-fidelity MSR simulations that can support reactor design optimization, safety assessments, and long-term operational strategies.

42 - ENGINEERING↗

VARIANCE ESTIMATION IN DOMAIN DECOMPOSED MONTE CARLO EIGENVALUE CALCULATIONS

The number of tallies performed in a given Monte Carlo calculation is limited in most modern Monte Carlo codes by the amount of memory that can be allocated on a single processor. By using domain decomposition, the calculation is now limited by the total amount of memory available on all processors, allowing for significantly more tallies to be performed. However, decomposing the problem geometry introduces significant issues with the way tally statistics are conventionally calculated. In order to deal with the issue of calculating tally variances in domain decomposed environments for the Shift hybrid Monte Carlo code, this paper presents an alternative approach for reactor scenarios in which an assumption is made that once a particle leaves a domain, it does not reenter the domain. Particles that reenter the domain are instead treated as separate independent histories. This assumption introduces a bias that inevitably leads to under-prediction of the calculated variances for tallies within a few mean free paths of the domain boundaries. However, through the use of different decomposition strategies, primarily overlapping domains, the negative effects of such an assumption can be significantly reduced to within reasonable levels.

42 ENGINEERING↗

On-the-Fly Treatment of Temperature Dependent Cross Sections in the Unresolved Resonance Regions in RMC Code

Monte Carlo method can provide high fidelity neutronics analysis of different nuclear reactors, owing to its advantages of the flexible geometry modeling and the use of continuous-energy nuclear cross sections. It can also be coupled with thermal-hydraulics codes to consider the feedback. For thermal reactors such as PWR and HTGR, two main temperature effects should be considered. The first is the effect of thermal motion of target nuclei in resolved resonance energy regions, which is known as Doppler effect. The second is the thermal scattering and bound effect in thermal energy regions. The traditional approach of pre-generated cross sections has difficulty in memory footprint for detailed temperature modelling in multi-physics calculations. Recently, on-the-fly (OTF) technique has been proposed in order to reduce the memory consumption for both resolved resonance energy and thermal energy. For fast reactors calculations, the temperature dependence of cross sections in the unresolved resonance energy regions is also important. However, less attention was paid to the unresolved resonance regions compared with resolved resonance energy and thermal energy. In this paper, the on-the-fly temperature treatment of cross sections in unresolved resonance regions was proposed and developed in RMC codes. The results show that the on-the-fly treatment has high efficiency and satisfactory fidelity. The on-the-fly treatment of unresolved resonance region was also combined with the target motion sampling (TMS) method for resolved resonance energy. The formats of libraries were changed, in which the probability tables were separated from the cross sections. Then the interpolation of probability table was performed on-the-fly during the transport routine. The results show that the on-the-fly treatment has high efficiency and satisfactory fidelity. The on-the-fly treatment of unresolved resonance region was also combined with the target motion sampling (TMS) method for resolved resonance energy, showing that TMS method is effective and accurate for cross sections treatment in resolved resonance energy regions. The memory saving of the on-the-fly treatment is also considerable. For the high-fidelity 'transport-burnup-thermal-hydraulics' coupling calculation, the memory requirement is 60 Mb. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Variance Reduction Techniques in RMC Burnup and Thermal-Hydraulic Coupled Calculation

In reactor analog simulation, the Monte Carlo method has relatively high fidelity since it can reduce calculation errors resulting from using approximation methods by describing complex geometry and neutron energy spectra. The Monte Carlo method is, in essence, a stochastic simulation of the neutron transport process, and statistical uncertainty of all the computed results must be provided. In large-scale reactor computation, this method can accurately estimate integral quantities such as the effective multiplication factor (K{sub eff}), and it can limit the uncertainty within an acceptable range via reasonably selecting simulation particles. Nevertheless, it faces great challenges in estimating local quantities like neutron flux and fission power, with uncertainty of estimators beyond acceptance. To decrease the uncertainty of local quantities by increasing simulation particles may cost much time and reduce efficiency. The main reasons are as follows. Firstly, the scale of reactors is so large that common pressurized water reactors have tens of thousands of lattice cells; secondly, uneven distribution of neutron flux and fission power causes uneven distribution of uncertainty. Smith K. puts forward the 95/95 principle to estimate whether uncertainty calculated with Monte Carlo Code satisfies the requirement. According to the principle, with a confidence level of 95%, statistical errors of power density in more than 95% of the regions should be less than 1%. To meet the requirement of the principle, the uniform fission site (UFS) method is raised currently. UFS aims at redistributing fission sources to uniformize the fission source sampling, which can make statistical variance distribution more uniform. This method, which is easy to use, will not obviously increase computation time. Many studies show that UFS has a good variance reduction effect in Monte Carlo criticality calculation, but less attention is paid to its performance in burnup calculation and thermal-hydraulic coupled calculation. Uncertainty arising from the Monte Carlo method has a large impact on burnup calculation and thermal-hydraulic coupled calculation. Variance propagates between burnup steps and between iterative steps of coupled calculation, which causes asymmetry of results of the physical symmetrical regions and instability of coupled iterative convergence errors. To further verify the effect of UFS, this study uses it in the RMC (the Reactor Monte Carlo code) burnup calculation module and the neutronics/thermohydraulics coupled calculation module, and conducts two-dimensional pressurized water reactor burnup calculation and BEAVRS benchmark thermalhydraulic coupled calculation. In this way, it verifies the improvement effect of UFS on variance propagation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Monte Carlo Simulation with High Order Polynomial Expansions

The functional expansion technique (FET) was recently developed for Monte Carlo simulation. The basic idea of the FET is to expand a Monte Carlo tally in terms of a high order expansion, the coefficients of which can be estimated via the usual random walk process in a conventional Monte Carlo code. If the expansion basis is chosen carefully, the lowest order coefficient is simply the conventional histogram tally, corresponding to a flat mode. This research project studied the applicability of using the FET to estimate the fission source, from which fission sites can be sampled for the next generation. The idea is that individual fission sites contribute to expansion modes that may span the geometry being considered, possibly increasing the communication across a loosely coupled system and thereby improving convergence over the conventional fission bank approach used in most production Monte Carlo codes. The project examined a number of basis functions, including global Legendre polynomials as well as “local” piecewise polynomials such as finite element hat functions and higher order versions. The global FET showed an improvement in convergence over the conventional fission bank approach. The local FET methods showed some advantages versus global polynomials in handling geometries with discontinuous material properties. The conventional finite element hat functions had the disadvantage that the expansion coefficients could not be estimated directly but had to be obtained by solving a linear system whose matrix elements were estimated. An alternative fission matrix-based response matrix algorithm was formulated. Studies were made of two alternative applications of the FET, one based on the kernel density estimator and one based on Arnoldi’s method of minimized iterations. Preliminary results for both methods indicate improvements in fission source convergence. These developments indicate that the FET has promise for speeding up Monte Carlo fission source convergence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Light emission efficiency and imaging performance of Gd{sub 2}O{sub 2}S:Eu powder scintillator under x-ray radiography conditions

Purpose: To evaluate Gd{sub 2}O{sub 2}S:Eu powder phosphor as a radiographic image receptor and to compare it to phosphors often used in radiography. Gd{sub 2}O{sub 2}S:Eu is nonhygroscopic, emitting red light with decay time close to that of Gd{sub 2}O{sub 2}S:Tb. Methods: The light intensity emitted per unit of x-ray exposure rate (absolute luminescence efficiency) was measured for laboratory prepared screens with coating thicknesses of 33.1, 46.4, 63.1, 78.3, and 139.8 mg/cm{sup 2} and tube voltages ranging from 50 to 140 kVp. Parameters related to image quality such as the modulation transfer function (MTF) and the detective quantum efficiency (DQE) were also experimentally examined. In addition, a previously validated Monte Carlo code was used to estimate intrinsic x-ray absorption and optical properties, as well as the MTF and the Swank factor (I) of the Gd{sub 2}O{sub 2}S:Eu scintillators. Results: Gd{sub 2}O{sub 2}S:Eu light intensity was found higher than that of single CsI:Tl crystal for tube voltages up to 100 kVp. The MTF and the DQE were found to be comparable with those of Gd{sub 2}O{sub 2}S:Tb and CsI:Tl screens. MTF estimated by the Monte Carlo code was found very close to the experimental MTF values. Gd{sub 2}O{sub 2}S:Eu showed peak emission in the wavelength range 620-630 nm. Its emission spectrum was excellently matched to various optical detectors (photodiodes, photocathodes, CCDs, and CMOS) employed in flat panel detectors. Conclusions: Gd{sub 2}O{sub 2}S:Eu is an efficient phosphor potentially well suited to radiography and especially to some digital detectors sensitive to red light.

36 MATERIALS SCIENCE↗

HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR brachytherapy planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Real-time capable modeling of neutral beam injection on NSTX-U using neural networks

A new model of heating, current drive, torque and other effects of neutral beam injection on NSTX-U that uses neural networks has been developed. The model has been trained and tested on the results of the Monte Carlo code NUBEAM for the database of experimental discharges taken during the first operational campaign of NSTX-U. By projecting flux surface quantities onto empirically derived basis functions, the model is able to efficiently and accurately reproduce the behavior of both scalars, like the total neutron rate and shine through, and profiles, like beam current drive and heating. The model has been tested on the NSTX-U real-time computer, demonstrating a rapid execution time orders of magnitude faster than the Monte Carlo code that is well suited for the iterative calculations needed to interpret experimental results, optimization during scenario development activities, and real-time plasma control applications. Simulation results of a proposed design for a nonlinear observer that embeds the neural network calculations to estimate the poloidal flux profile evolution, as well as effective charge and fast ion diffusivity, are presented.

Neural networks↗

SU-F-T-12: Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy

Purpose: The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. Methods: The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The XCOM photon cross-section library was used. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. Results: The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range. Conclusion: The dose rate constant is consistent with the results of Granero et al. and Selvam and Bhola within 1%. Dose rate data are compared to GEANT4 and DORZnrc Monte Carlo code. However, the radial dose function is different by up to 10% for the points that are notably near the source on the transversal axis because of the high-energy photons from 60Co, which causes an electronic disequilibrium at the interface between the source capsule and the liquid water for distances up to 1 cm.

60 APPLIED LIFE SCIENCES↗